首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Two independent methods for the determination of diclofenac were simultaneously implemented in an automated analytical system, based on the concept of sequential injection analysis, providing real-time assessment of results quality. The potentiometric detection was carried out with an ion-selective electrode based on a cyclodextrin while for the fluorimetric determination the sample was previously subject to in-line irradiation with UV light. The potentiometric and photochemical-fluorimetric determinations exhibited linear working ranges of 5×10−6 to 1×10−2 and 1×10−6 to 1×10−4 mol dm−3, respectively. Relative standard errors of 0.5% for the potentiometric determination and 0.6% for the photochemical-fluorimetric determination were obtained after 10 consecutive injections of a 5×10−5 mol dm−3 diclofenac standard solution. The sampling rate was about 32 samples h−1. Both methods were applied in the analysis of pharmaceutical formulations. The quality of results obtained was evaluated by comparison to the reference method, with no statistically significant differences for a 95% confidence level.  相似文献   

2.
Ohura H  Imato T  Yamasaki S 《Talanta》1999,49(5):1383-1015
A rapid potentiometric flow injection technique for the simultaneous determination of oxychlorine species such as ClO3–ClO2 and ClO3–HClO has been developed, using both a redox electrode detector and a Fe(III)–Fe(II) potential buffer solution containing chloride. The analytical method is based on the detection of a large transient potential change of the redox electrode due to chlorine generated via the reaction of the oxychlorine species with chloride in the potential buffer solution. The sensitivities to HClO and ClO2 obtained by the transient potential change were enhanced 700–800-fold over that using an equilibrium potential. The detection limit of the present method for HClO and ClO2 is as low as 5×10−8 M with use of a 5×10−4 M Fe(III)–1×10−3 M Fe(II) buffer containing 0.3 M KCl and 0.5 M H2SO4. On the other hand, sensitivity to ClO3 was low when a potential buffer solution containing 0.5 M H2SO4 was used, but could be increased largely by increasing the acidity of the potential buffer. The detection limit for ClO3 was 2×10−6 M with the use of a 5×10−4 M Fe(III)–1×10−3 M Fe(II) buffer containing 0.3 M KCl and 9 M H2SO4. By utilizing the difference in reactivity of oxychlorine species with chloride in the potential buffer, a simultaneous determination method for a mixed solution of ClO3–ClO2 or ClO3–HClO was designed to detect, in a timely manner, a transient potential change with the use of two streams of potential buffers which contain different concentrations of sulfuric acid. Analytical concentration ranges of oxychlorine species were 2×10−5–2×10−4 M for ClO3, and 1×10−6–1×10−5 M for HClO and ClO2. The reproducibility of the present method was in the range 1.5–2.3%. The reaction mechanism for the transient potential change used in the present method is also discussed, based on the results of batchwise experiments. The simultaneous determination method was applied to the determination of oxychlorine species in a tap water sample, and was found to provide an analytical result for HClO, which was in good agreement with that obtained by the o-tolidine method and to provide a good recovery for ClO3 added to the sample.  相似文献   

3.
Khodari M  Abou Krisha MM  Fandy R 《Talanta》1994,41(12):2179-2182
The utility of carbon paste modified with 2,3-dicyano 1,4-naphthoquinone (CYNQ) for the voltammetric determination of Ag(I) is demonstrated. The method is based on the formation of Ag(I) complex with CYNQ by accumulation from the aqueous solution to the electrode surface without an applied potential. Using the medium exchange technique, the electrode was transferred to another media followed by linear-scan voltammetric measurements. The reduction peak of the Ag(I)-CYNQ complex was observed at +0.22 V (vs. SCE). The silver response is studied with respect to paste composition, pH of the measurement solution, reproducibility, interference and other variables. A detection limit of 5 × 10−8M was obtained and the calibration curve was linear over the range 1 × 10−6−8 × 10−5M.  相似文献   

4.
van Staden JF  Stefan RI 《Talanta》1999,49(5):1472-1022
An on-line automated system for the simultaneous flow injection determination of calcium and fluoride in natural and borehole water with conventional calcium-selective and fluoride-selective membrane electrodes as sensors in series is described. Samples (30 μl) are injected into a TISAB II (pH=5.50) carrier solution as an ionic strength adjustment buffer. The sample-buffer zone formed is first channeled to a fluoride-selective membrane electrode and then via the calcium-selective membrane electrode to the reference electrodes. The system is suitable for the simultaneous on-site monitoring of calcium (linear range 10−5–10−2 mol l−1 detection limit 1.94×10−6 mol l−1 recovery 99.22%, RSD<0.5%) and fluoride (linear range 10−5–10−2 mol l−1 detection limit 4.83×10−6 mol l−1 recovery 98.63%, RSD=0.3%) at a sampling rate of 60 samples h−1.  相似文献   

5.
Cai CX  Xue KH 《Talanta》1998,47(5):4188-1119
A stable electroactive thin film of poly(toluidine blue o) (PTOB) has been deposited on the surface of a glassy carbon electrode by cyclic voltammetry from an aqueous solution containing toluidine blue o (TOB). Cyclic voltammograms of PTOB indicate the presence of two redox couples and the formal potential shifts linearly in the negative direction with increasing solution pH with a slope of 58 and 54 mV per pH unit for couple I and couple II, respectively. The PTOB modified glassy carbon electrode shows electrocatalytic activity toward NADH oxidation in phosphate buffer solution (pH 7.0), with an overpotential ca. 470 mV lower than that of the bare electrode. The catalytic rate constant of the modified glassy carbon electrode for the oxidation of NADH is determined by cyclic voltammetry and rotating disk electrode measurements. The experimental results indicate that the electrode can be used as a detector for NADH determination with a linear range of 5.0×10−6 to 2.0×10−3 mol l−1 and the detection limits of (5.0±0.3)×10−7 mol l−1 at optimal conditions.  相似文献   

6.
By designing a novel flow-through electrolytic cell (FEC), bromine was produced near to the surface of the platinum electrode by electrochemical oxidation of acidic KBr. The fast and weak chemiluminescence signal produced by the chemical reaction of the electrogenerated bromine with H2O2 was greatly enhanced by tetracyclines Based on these observations, a new, sensitive and simple electrogenerated chemiluminescence (ECL) method for the determination of tetracyclines was developed. Under the optimum experimental conditions, the calibration graphs are linear over the range 3.0×10−8 to 5.0×10−5 g ml−1 for tetracycline, 2.0×10−7 to 2.4×10−5 g ml−1 for oxytetracycline and 1.0×10−7 to 5.0×10−5 g ml−1 for chlortetracycline. The limits of detection (S/N=3) are 1.0×10−8 g ml−1 for tetracycline, 7.0×10−8 g ml−1 for oxytetracycline and 1.5×10−7 g ml−1 for chlortetracycline. For the determination 5.0×10−7 g ml−1 tetracycline, the relative standard deviation was <5%. The proposed method was used to determine tetracyclines in pharmaceutical formulations.  相似文献   

7.
Plasticized poly(vinyl chloride) (PVC) membranes of different compositions were tested for use in the construction of potentiometric flow detectors for triiodide. A membrane with a 2:1 (w/w) 2-nitrophenyl octyl ether to PVC ratio was selected. The influence of thiosulphate in the carrier solution composition and of the flow-injection variables on the determination of triiodide was studied. In the selected conditions, a linear relationship between peak height and log[I3] was obtained between 5 × 10−6 and 1 × 10−4 mol l−1 triiodide. Peak height relative standard deviations for 2 × 10−5 and 1 × 10−4 mol l−1 triiodide were ±0.4 and ±1.8%, respectively, and sampling frequency was 80 samples per hour. The method proposed was applied satisfactorily to the iodometric determination of different chlorine-containing disinfectants, among them trichloroisocyanuric acid and dichloroisocyanurate in several types of commercial sample.  相似文献   

8.
Xu J  Wang Y  Xian Y  Jin L  Tanaka K 《Talanta》2003,60(6):1123-1130
A multiwall carbon nanotubes (MWNTs) film modified electrode was prepared and used as an amperometric sensor for the simultaneous determination of oxidizable amino acids including cysteine, tryptophane and tyrosine. The electrochemical behaviors of these amino acids at this modified electrode were studied by cyclic voltammetry (CV). The results indicated that the MWNTs chemically modified electrode (CME) exhibited efficient electrocatalytic activity towards the oxidation of these amino acids with relatively high sensitivity, stability and long-life. Following separation by ion chromatography (IC) with 2.0×10−3 mol l−1 citric acid buffer solution (pH 6.5) as eluent, cysteine, tryptophane and tyrosine could be determined by the MWNTs CME successfully. Under the optimal conditions, the detection limits were 7.0×10−7 mol l−1 for cysteine, 2.0×10−7 mol l−1 for tryptophane and 3.5×10−7 mol l−1 for tyrosine at the signal-to-noise of 3, respectively. The method was applied successfully to the determination of these substances in plasma.  相似文献   

9.
A chemically modified electrode is constructed based on the multi-walled carbon nanotubes (MWNTs)/4-aminobenzeresulfonic acid (4-ABSA) film-coated glassy carbon electrode. The electrocatalytic oxidation of tyrosine (Tyr) is investigated on the surface of the MWNTs/4-ABSA-modified electrode using cyclic voltammetry (CV) and differential pulse voltammetry (DPV). The prepared modified electrode shows voltammetric responses with high sensitivity and selectivity for Tyr in optimal conditions, which makes it very suitable for sub-micromolar detection of Tyr. A sensitive oxidation peak at +0.64 V is employed to determine Tyr. Good linear relationship between the oxidation peak current and the Tyr concentration in the range of 1 × 10−7 to 5 × 10−5 mol/L is obtained in phosphate buffer solution with pH 7.0. By use of modified electrode, the voltammetric detection limit for Tyr in DPV measurements is 8 × 10−8 mol/L (S/N = 3). Good sensitivity, selectivity and stability of the low-cost modified electrode make it very suitable for the determination of trace amounts of Tyr in pharmaceutical and clinical preparations.  相似文献   

10.
Zeng B  Yang Y  Ding X  Zhao F 《Talanta》2003,61(6):819-827
A novel method for the determination of perphenazine has been developed. The method is based on the accumulation of perphenazine at a gold electrode modified with decanethiol (DEC) self-assembled monolayer (SAM) and its oxidation at about 0.6 V (vs. saturated calomel electrode (SCE)). Because some coexistent electroactives were blocked and perphenazine was selectively accumulated by the SAM, the electrode exhibited good selectivity and sensitivity. Various conditions were optimized for practical application. Under the selected conditions (i.e. 0.05 M pH 10 sodium borate buffer, accumulation time: 120 s, accumulation potential: −0.4 V, scan rate: 100 mV s−1), the anodic stripping peak current was linear to perphenazine concentration in the ranges of 6×10−9–5×l0−7 and 5×10−7–5×10−6 M with correlation coefficients of 0.998 and 0.995, respectively. For a 1.0×10−6 M perphenazine solution, the relative standard deviation of peak height was 2.3% (n=8). This method was applied to the determination of perphenazine in some drugs and the recovery was 92–101%. In addition, it was found that in the presence of perphenazine, the SAM structure changed a little and more needle holes appeared. However, the SAM could recover the original form when perphenazine and its redox product were removed from the monolayer by repeatedly cycling the electrode in a blank solution for a minute. The modified electrode was characterized by alternating current impedance and electrochemical probe.  相似文献   

11.
The cathodic adsorptive electrochemical behavior of guanine in the presence of some metal ions at the static mercury drop electrode was investigated. A 1.0×10−3 mol l−1 NaOH or a 2.0×10−2 mol l−1 Hepes buffer at pH 8.0 solutions were used as supporting electrolytes. The reduction peak potential for guanine was found to be around −0.15 V, which is very close to the mercury reduction wave. A new peak appears at −0.60 V in the presence of copper or at −1.05 V in the presence of zinc. A square wave voltammetric procedure for electroanalytical determination of guanine in 2.0×10−2 mol l−1 Hepes buffer at pH 8.0 containing 1.6×10−5 mol l−1of copper ions, was developed. An accumulation potential of −0.15 V during 270 s for the prior adsorption of guanine at the electrode surface was used. The response of the system was found to be linear in the range of guanine concentration from 6.62×10−8 to 1.32×10−7 mol l−1 and the detection limit was 7.0×10−9 mol l−1. The influence of DNA bases such as adenine, cytosine and thymine was also examined. Cyclic voltammetry was used to characterize the interfacial and redox mechanism.  相似文献   

12.
The electrochemical behaviour of carminomycin at carbon-paste, glassy-carbon and composite carbon—polymer electrodes has been compared. Three electroactive sites on the molecule have been identified. Two sites are involved in the oxidation processes, the first corresponding to the hydroquinone structure in the C-6/C-11 positions, the second attributed to the C-4 phenolic function. Applying a negative-going scan allows reduction of the quinone moiety in the C-5/C-12 positions. Both the quinone and hydroquinone functions exhibit quasi-reversible electrochemical reactions in acidic medium, becoming irreversible in alkaline solution. Adsorption phenomena accompany both the oxidation and reduction processes, primarily in neutral and alkaline media. The adsorption can be decreased by using the composite electrode, which is less sensitive to surface phenomena. This working electrode is proposed as the most suitable for the determination of carminomycin at pH 1. A linear calibration plot can be obtained over the range 1 × 10−6-1 × 10−4M, with a limit of detection of 6 × 10−8M.  相似文献   

13.
Chen GN  Zhang L  Lin RE  Yang ZC  Duan JP  Chen HQ  Hibbert DB 《Talanta》2000,50(6):1275-1281
The electrogenerated chemiluminescent (ECL) behavior of hemin at a platinum electrode in the alkaline solution has been investigated in detail. Under the optimum conditions the linear response range of hemin is 1.0×10−5–1.0×10−8 g ml−1, the detection limit was 1.0×10−8 g ml−1, and the relative standard derivation for 1×10−7 g ml−1 hemin was 2.8%. It has been also found that hemin would catalyze the ECL of lucigenin at a platinum electrode in a neutral solution in the presence of hydrogen peroxide, the catalytic ECL intensity was linear with the concentration of hemin in the range of 1.0×10−14–1.0×10−10 g ml−1. IgG labeled with hemin was used to examine the ECL catalytic activity of hemin after conjugating to protein, and the results showed that hemin retained ECL catalytic activity when conjugated to protein.  相似文献   

14.
A graphite–Teflon–tyrosinase composite biosensor for the determination of benzoic acid in foodstuffs is reported. The biosensor functioning is based on the inhibition effect of benzoic acid on the biocatalytic activity of the enzyme in a reversed micelle working medium formed with ethyl acetate as the continuous phase, a 0.05 mol l−1 phosphate buffer solution of pH 7.4 (5%) as the aqueous dispersed phase, and 0.10 mol l−1 dioctyl sulfosuccinate (AOT) as the emulsifying agent. A potential value of −0.10 V, and a constant enzyme-substrate (phenol) concentration of 2.0×10−4 mol l−1 were selected to carry out the amperometric inhibition measurements. The tyrosinase inhibition process by benzoic acid is reversible and of the competitive type, with an apparent inhibition constant of 0.016 mmol l−1. The composite bioelectrodes allow the regeneration of the electrode surface by polishing and exhibit long-term operation and stability. A limit of detection of 9.0×10−7 mol l−1 benzoic acid was obtained. An interference study from other substances which can be found in foodstuffs together with benzoic acid was performed. Taking advantage of the capabilities of reversed micelles as universal solubilization media, the composite tyrosinase electrode was used for the determination of benzoic acid in two different kind of samples: mayonnaise sauce, which is a highly hydrophobic matrix, and Cola soft drinks, a hydrophilic matrix for which practically no sample treatment is necessary.  相似文献   

15.
Masadome T  Sonoda R  Asano Y 《Talanta》2000,52(6):1123-1130
A potentiometric flow injection determination method for iodide ion in a photographic developing solution was proposed by utilizing a flow-through type iodide ion-selective electrode detector. The sensing membrane of the electrode was Ag2S–AgI membrane. The response of the electrode detector as a peak-shape signal was obtained for injected iodide ion in a photographic developing solution. A linear relationship in the subnernstian zone was found to exist between peak height and the concentration of the iodide ion in a photographic developing solution in a concentration range from 0 to 6.0×10−5 mol l−1. The relative standard deviation for ten injections of 2×10−5 mol l−1 iodide ion in a photographic developing solution was 0.96% and the sampling rate was approximately 12–13 samples h−1. The iodide ion could be determined under coexisting of an organic reducing reagent and inorganic electrolytes of high concentration in a photographic developing solution sample solution by the present method.  相似文献   

16.
Zhang N  Zhang X  Zhao Y 《Talanta》2004,62(5):1041-1045
The behavior of the ciprofloxacin (CPFX) complex with copper, Cu(II)L2, at a mercury electrode has been investigated in borax–boric acid buffer. The adsorption phenomena were observed by linear sweep voltammetry. The mechanism of the electrode reaction was found to be reduction of Cu(II)L2 adsorbed on the surface of the electrode by an irreversible charge transfer to metal amalgam, Cu(0)(Hg). In the presence of DNA, the formation of the electrochemically non-active complexes Cu(II)L2–DNA results in the decrease of the equilibrium concentration of Cu(II)L2 and its peak current. Under the optimum conditions, the decrease of the peak current is proportional to DNA concentration. The linear ranges are 6.67×10−8 to 1.20×10−5 g ml−1 for calf thymus DNA (ctDNA), 3.30×10−8 to 2.33×10−6 g ml−1 for fish sperm DNA (fsDNA) and 1.0×10−8 to 1.2×10−6 g ml−1 for yeast RNA. The detection limits are 5.00×10−9, 3.00×10−9 and 2.50×10−9 g ml−1, respectively. This method exhibits good recovery and high sensitivity.  相似文献   

17.
Zareh MM  Ghoneim AK  Abd El-Aziz MH 《Talanta》2001,54(6):1049-1057
The lipophilic ammonium salt of 1-pyrrolidine dicarbodithioic acid (PCDT)[I] was introduced as a selective ionophore for a sensitive Pb-ion selective electrode. Also, the effect of immobilization of 18-crown-6 (CW), into the above membrane, on the electrode performance was discussed. The slope of the PCDT-based [I] electrode was (26–30 mV decade−1), while it was (29-30 mV decade−1) for (PCDT+CW)-based [II] electrode according to the doping time. The linear concentration ranges were (1×10−6–1×10−1 M) and (5×10−5–1×10−1 M) for electrode types [I] and [II] after one-day doping. The working pH ranges were (5.0–10.0) and (7.0–10.0) for electrode types [I] and [II], respectively. Most of the common cations were tested for the evaluation of the electrode selectivity with correlation to the ionic radii of the tested cations. Among them only Na+, Ag+ and Fe3+ were the real interference. Application of using the electrode for the determination of lead in lubrication oil samples was performed with RSD (0.86–1.03%). The obtained results were compared to those of an atomic absorption spectrophotometric method.  相似文献   

18.
Pei J  Li XY 《Talanta》2000,51(6):2379-1115
A thin film of mixed-valent CuPtCl6 is deposited on a glassy carbon electrode by continuous cyclic scanning in a solution containing 3×10−3 M CuCl2+3×10−3 M K2PtCl6+1 M KCl in the potential range from 700 to −800 mV. The cyclic voltammetry is used to study the electrochemical behaviors of nitrite on CuPtCl6/GC modified electrode and the electrode displays a good catalytic activity toward the oxidation of nitrite. The effects of the film thickness, pH, the electrode stability and precision have been evaluated. Experiments in flow-injection analysis are performed to characterize the electrode as an amperometric sensor for the detection of nitrite. The modified electrode shows a wide dynamic range, quite a low detection limit and short response time. The linear relationship between the flow-injection peak currents and the concentrations of nitrite is at a range of 1×10−7–2×10−3 M with a detection limit of 5×10−8 M.  相似文献   

19.
Wang Z  Zhang H  Zhou S  Dong W 《Talanta》2001,53(6):1133-1138
A novel method is described for determination of metoclopramide (MCP) by second-derivative adsorptive anodic stripping voltammetry with a nafion-modified electrode. The stripping peak current is proportional to the concentration of MCP over the range 1.2×10−9–4.6×10−7 M. The detection limit is 8.0×10−11 M with 4-min accumulation. The method has been successfully applied to the determination of MCP in human serum.  相似文献   

20.
Huang F  Jin G  Liu Y  Kong J 《Talanta》2008,74(5):1435-1441
Phenylephrine (i.e. PHE) and chlorprothixene (i.e. CPT), two effective and important antipsychotic drugs with low redox activity, were found generating an irreversible anodic peak at about +0.89 V (vs. SCE) and +1.04 V in 0.05 M HAc–NaAc (pH 5.0) or NH2CH2COOH–HCl (pH 2.4) buffer solution at poly(4-aminobenzene sulfonic acid) modified glassy carbon electrode (i.e. poly(4-ABSA)/GC), respectively. Sensitive and quantitative measurement for them based on the anodic peaks was established under the optimum conditions. The anodic peak current was linear to PHE and CPT concentrations from 1 × 10−7 to 1.5 × 10−5 M and 2 × 10−6 to 4.5 × 10−5 M, the detection limits obtained were 1 × 10−8 and 1 × 10−7 M, separately. The modified electrode exhibited some excellent characteristics including easy regeneration, high stability, good reproducibility and selectivity. The method proposed was successfully applied to the determination of PHE and CPT in drug injections or tablets and proved to be reliable compared with ultraviolet spectrophotometry. The modified electrode was characterized by electrochemical methods.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号