首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Glass cells play an important role in polarized 3He neutron spin filters. To evaluate the scattering and absorption contribution from glass cells during neutron scattering experiments, we measured small-angle scattering and neutron transmission in GE180 and other glasses. The small-angle neutron scattering measurements revealed that the glasses used for 3He spin filters have acceptably lower scattering: (Q)/=4-7×10−4 cm−1 at Q=0.03-0.12 Å−1. The transmission measurement was performed at J-PARC. Neutron transmission of about 92% through empty GE180 cells was observed over a wide wavelength range 0.014-7.0 Å. To pursue the possibility of being a structural influence on 3He spin relaxation in GE180 glass cells, we performed precise X-ray diffraction measurement using synchrotron radiation at SPring-8. From these measurements, a structural difference was observed among GE180 glasses with different thermal treatments.  相似文献   

2.
Polarized 3He neutron spin filters can operate over a wide neutron energy range and provide a large angular acceptance. A compact 3He neutron spin filter system has been developed for the Multi-Axis Crystal Spectrometer at the National Institute of Standards and Technology (NIST) Center for Neutron Research. Sealed 3He cells, polarized by spin-exchange optical pumping, are used as polarizer and analyzer. The polarization of the neutrons incident on the sample is inverted by flipping the polarization of the 3He gas in the polarizer, with only a small effect on the analyzer cells. The cell fabrication process, 3He spin flipper, and the holding magnetic field are discussed and we present the results of a first on-linetest.  相似文献   

3.
We measured the neutron beam polarization of the BL05/NOP (Neutron Optics and Physics) beamline at J-PARC with an accuracy of less than 10−3 using polarized 3He gas as a neutron spin analyzer. Precise polarimetry of the neutron beam is necessary to understand the beamline optics as well as for the asymmetry measurements of the neutron beta decay, which are planned in this beamline.  相似文献   

4.
Dynamic nuclear polarization and dissolution of a 13C-labeled substrate enables the dynamic imaging of cellular metabolism. Spectroscopic information is typically acquired, making the acquisition of dynamic volumetric data a challenge. To enable rapid volumetric imaging, a spectral-spatial excitation pulse was designed to excite a single line of the carbon spectrum. With only a single resonance present in the signal, an echo-planar readout trajectory could be used to resolve spatial information, giving full volume coverage of 32 × 32 × 16 voxels every 3.5 s. This high frame rate was used to measure the different lactate dynamics in different tissues in a normal rat model and a mouse model of prostate cancer.  相似文献   

5.
Polarized 3He spin-filters are currently employed on a wide range of neutron instruments at the ILL, primarily for diffraction, reflectometry and fundamental physics. A wide range of recent and ongoing improvements are enabling the implementation of this technique for wide-angle polarization analysis for inelastic measurements. These include
• Progress in metastability-exchange optical pumping (MEOP), resulting in on-beam polarization levels of up to 80%.
• 1st generation “Pastis-1” coils for rotating the neutron polarization at the sample position, allowing for “XYZ” polarization analysis.
• 2nd generation “Pastis-2” coils with no blind angles in the equatorial plane.
• Spin-filter cells with glued silicon windows, allowing for wide-angle “banana” cells with very low background scattering.
• Polarization-preserving capillaries for transferring polarized 3He gas into the cell without manual access.
The development of capillary transfer also allows for a completely new way of working with 3He spin-filters: connecting the cells on the instruments directly to the MEOP filling station several tens of meters away and allowing for quasi-continuous operation.  相似文献   

6.
Absolute frequency stabilization of an extended-cavity diode laser at 0.94 μm is reported. The diode laser was frequency locked against rovibrational absorption lines of water vapour by using the frequency modulation spectroscopy technique. The stabilized oscillator shows a short-term frequency stability level of 40 kHz for integration times of 1 s and a long-term frequency drift lower than 10 MHz for observation times longer than 103 s. The frequency-stabilized oscillator system is mounted on a compact breadboard (75 cm×50 cm) and constitutes the seed laser system for the injection of a high-energy DIAL laser transmitter operating in the 0.94-μm spectral region.  相似文献   

7.
To address the problem of the shortage of neutron detectors used in radiation portal monitors(RPMs),caused by the ~3He supply crisis, research on a cadmium-based capture-gated fast neutron detector is presented in this paper. The detector is composed of many 1 cm × 1 cm × 20 cm plastic scintillator cuboids covered by 0.1 mm thick film of cadmium. The detector uses cadmium to absorb thermal neutrons and produce capture γ-rays to indicate the detection of neutrons, and uses plastic scintillator to moderate neutrons and register γ-rays. This design removes the volume competing relationship in traditional ~3He counter-based fast neutron detectors, which hinders enhancement of the neutron detection efficiency. Detection efficiency of 21.66% ± 1.22% has been achieved with a 40.4 cm × 40.4cm × 20 cm overall detector volume. This detector can measure both neutrons and γ-rays simultaneously. A small detector(20.2 cm × 20.2 cm × 20 cm) demonstrated a 3.3 % false alarm rate for a ~(252)Cf source with a neutron yield of 1841 n/s from 50 cm away within 15 s measurement time. It also demonstrated a very low(0.06%) false alarm rate for a 3.21 × 10~5 Bq ~(137)Cs source. This detector offers a potential single-detector replacement for both neutron and the γ-ray detectors in RPM systems.  相似文献   

8.
This article reports the accumulation effect of the 3He originating from tritium β decay; 3He created in solid remains in it, while one in liquid diffuses and goes out to the vapor gas. We observed this effect through the neutron detection from muon catalyzed fusion phenomenon (μCF), and gave it qualitative understanding, by which the muon transfer rate from (dμ) and (tμ) to helium was derived. This revised version was published online in August 2006 with corrections to the Cover Date.  相似文献   

9.
At the NIST Center for Neutron Research (NCNR), we have applied 3He neutron spin filters (NSFs) to the instruments where 3He NSFs are advantageous, such as thermal triple-axis spectrometry, small-angle neutron scattering, and diffuse reflectometry. We present the status of our development and application of this method, including polarized gas production by spin-exchange optical pumping, magnetostatic cavities for storage of the polarized gas on the beam line, and nuclear magnetic resonance (NMR)-based, on-line monitoring and reversal of the 3He polarization. We present the status of developing user-friendly interfaces incorporated into the instrument software to handle these 3He neutron spin filters while taking data and performing data analysis. Finally we discuss the status of development of a polarization capability on the multi-axis crystal spectrometer, which requires polarization analysis over a 220° angular range.  相似文献   

10.
R. Jimenez  A. Rivera  A. Varez  J. Sanz   《Solid State Ionics》2009,180(26-27):1362-1371
The dependence of Li mobility on structure and composition of Li0.5 − xNaxLa0.5TiO3 perovskites (0 ≤ x ≤  0.5) has been investigated by means of neutron diffraction, nuclear magnetic resonance and impedance spectroscopy. At 300 K, all samples display a rhombohedral superstructure (R-3c S.G.), where octahedra are out of phase tilted along [111] direction of the ideal cubic cell. The elimination of the octahedral tilting is responsible for the rhombohedral–cubic transformation, detected near 1000 K. In these perovskites, La and Na cations are randomly distributed in A sites, but Li ions are fourfold coordinated at unit cell faces of the cubic perovskite. Lithium conductivity, σ300 K, decreases with the sodium content, decreasing from values typical of fast ionic conductors, 10− 3 S/cm, to those of good insulators, 10− 10 S/cm, when the interconnectivity between vacant A sites is lost (x > 0.3). In samples with x < 0.3, dc conductivity displays a non-Arrhenius behaviour, decreasing activation energy from ~ 0.37 to 0.25 eV when the sample is heated between 77 and 500 K. The temperature dependence of BLi factors shows the existence of two regimes for Li motion. Below 373 K, Li ions remain partially located near square oxygen windows that connect contiguous A sites, but above 400 K, extended Li motions become dominant. The additional decrease of activation energy from 0.25 to 0.16 eV (low-temperature 7Li NMR value), should require the full elimination of octahedral tilting which is only produced above 1000 °C.  相似文献   

11.
Effects of fast neutron irradiation and post-annealing on magnetic properties of Rb3C60 were studied through the dc magnetization measurement. Rb3C60 powder samples were prepared in an evacuated quartz glass tube, and the temperature and the magnetic field dependences of dc magnetization were measured before and after irradiation and after post-annealing. The neutron fluences were 1.0, 1.8 and 3.3 × 1016 n/cm2, and the post-annealing was made at a temperature of 473 K for 3 h. Magnetic hysteresis of the samples irradiated at the fluence of 1.8 and 3.3 × 1016 n/cm2 disappeared, and the hysteresis curves hardly changed at the fluence of 1.0 × 1016 n/cm2. As for the post-annealing effect, the hysteresis curves of the sample irradiated at the fluence of 1.8 × 1016 n/cm2 were completely recovered after annealing, while those of the other samples, which had a magnetic background before irradiation, were not recovered. In this study, it was found that the loss of superconductivity in Rb3C60 powder is observed when the neutron irradiation fluence exceeds 1.0 × 1016 n/cm2, and the lost superconductivity is completely recovered by the post-annealing at 473 K for 3 h.  相似文献   

12.
In recent years, polarized 3He gas has increasingly been used as neutron polarizers and polarization analyzers. Two of the leading methods to polarize the 3He gas are the spin-exchange optical pumping (SEOP) method and the meta-stable exchange optical pumping (MEOP) method. At present, the SEOP setup is comparatively compact due to the fact that it does not require the sophisticated compressor system used in the MEOP method. The temperature and the laser power available determine the speed, at which the SEOP method polarizes the 3He gas. For the quantity of gas typically used in neutron scattering work, this speed is independent of the quantity of the gas required, whereas the polarizing time using the MEOP method is proportional to the quantity of gas required. Currently, using the SEOP method to polarize several bar-liters of 3He to 70% polarization would require 20−40 h. This is an order of magnitude longer than the MEOP method for the same quantity of gas and polarization. It would therefore be advantageous to speed up the SEOP process. In this article, we analyze the requirements for temperature, laser power, and the type of alkali used in order to shorten the time required to polarize 3He gas using the SEOP method.  相似文献   

13.
The unstable nucleus5He emission has never been included in the widely used statistical model codes as the evaluation tool and interpretation experimental data. The calculated threshold energies of5He emission from light nuclei to heavy nuclei indicate that in most cases the compound nucleus induced by incident neutron would emit5He rather than3He. Since5He is unstable and can be separated into n+α spontaneously, so neutron is produced in5He emission process. The formulation of the double-differential cross section of the neutron from the two-body breakup process of emitted5He is established. Because of the strong recoil effect, the energy balance is strictly taken into account to meet the needs in nuclear engineering. Further improvement of the statistical model calculation codes on this respect is proposed. It is expected that the correlative measurement will be available to account the outgoing neutron and alpha particle simultaneously and to test and verify the existence of5He emission.  相似文献   

14.
We describe here a method of performing adiabatic fast passage (AFP) spin flipping of polarized 3He used as a neutron spin filter (NSF) to polarize neutron beams. By reversing the spin states of the 3He nuclei the polarization of a neutron beam can be efficiently reversed allowing for the transmission of a neutron beam polarized in either spin state. Using an amplitude modulated frequency sweep lasting 500 ms we can spin flip a polarized 3He neutron spin filter with only 1.8×10−5 loss in 3He polarization. The small magnetic fields (10-15 G) used to house neutron spin filters mean the 3He resonant frequencies are low enough to be generated using a computer with a digital I/O card. The versatility of this systems allows AFP to be performed on any beamline or in any laboratory using 3He neutron spin filters and polarization losses can be minimised by adjusting sweep parameters.  相似文献   

15.
A neutron calibration field using 241Am–Li sources and a moderator was designed to simulate the neutron fields found outside a reactor. The moderating assembly selected for the design calculation consists of a cube of graphite blocks with dimensions of 50 cm by 50 cm by 50 cm, in which the 241Am–Li sources are placed. Monte Carlo calculations revealed the optimal depth of the source to be 15 cm. This moderated neutron source can be used to provide a test field that has a large number of intermediate energy neutrons with a small portion of MeV component.  相似文献   

16.
This paper reports the spectral properties and energy levels of Cr3+:Sc2(MoO4)3 crystal. The crystal field strength Dq, Racah parameter B and C were calculated to be 1408 cm−1, 608 cm−1 and 3054 cm−1, respectively. The absorption cross sections σα of 4A24T1 and 4A24T2 transitions were 3.74×10−19 cm2 at 499 nm and 3.21×10−19 cm2 at 710 nm, respectively. The emission cross section σe was 375×10−20 cm2 at 880 nm. Cr3+:Sc2(MoO4)3 crystal has a broad emission band with a broad FWHM of 176 nm (2179 cm−1). Therefore, Cr3+:Sc2(MoO4)3 crystal may be regarded as a potential tunable laser gain medium.  相似文献   

17.
A low background thermal neutron flux detection system has been designed to measure the ambient thermal neutron flux of the second phase of the China Jinping Underground Laboratory(CJPL-Ⅱ),right after completion of the rock bolting work.A ~3He proportional counter tube combined with an identical ~4He proportional counter tube was employed as the thermal neutron detector,which has been optimised in energy resolution,wall effect and radioactivity of construction materials for low background performance.The readout electronics were specially designed for long-term stable operation and easy maintenance in an underground laboratory under construction.The system was installed in Lab Hall No.3 of CJPL-Ⅱ and accumulated data for about 80 days.The ambient thermal neutron flux was determined under the assumption that the neutron field is fully thermalized,uniform and isotropic at the measurement position.  相似文献   

18.
This paper is devoted to the third part of the analysis of the very weak absorption spectrum of the 18O3 isotopologue of ozone recorded by CW-Cavity Ring Down Spectroscopy between 5930 and 6900 cm−1. In the two first parts [A. Campargue, A. Liu, S. Kassi, D. Romanini, M.-R. De Backer-Barilly, A. Barbe, E. Starikova, S.A. Tashkun, Vl.G. Tyuterev, J. Mol. Spectrosc. (2009), doi: 10.1016/j.jms.2009.02.012 and E. Starikova, M.-R. De Backer-Barilly, A. Barbe, Vl.G. Tyuterev, A. Campargue, A.W.Liu, S. Kassi, J. Mol. Spectrosc. (2009) doi: 10.1016/j.jms.2009.03.013], the effective operators approach was used to model the spectrum in the 6200–6400 and 5930–6080 cm−1 regions, respectively. The analysis of the whole investigated region is completed by the present investigation of the 6490–6900 cm−1 upper range. Three sets of interacting states have been treated separately. The first one falls in the 6490–6700 cm−1 region, where 1555 rovibrational transitions were assigned to three A-type bands: 3ν2 + 5ν3, 5ν1 + ν2 + ν3 and 2ν1 + 3ν2 + 3ν3 and one B-type band: ν1 + 3ν2 + 4ν3. The corresponding line positions were reproduced with an rms deviation of 18.4 × 10−3 cm−1 by using an effective Hamiltonian (EH) model involving eight vibrational states coupled by resonance interactions. In the highest spectral region – 6700–6900 cm−1 – 389 and 183 transitions have been assigned to the ν1 + 2ν2 + 5ν3 and 4ν1 + 3ν2 + ν3 A-type bands, respectively. These very weak bands correspond to the most excited upper vibrational states observed so far in ozone. The line positions of the ν1 + 2ν2 + 5ν3 band were reproduced with an rms deviation of 7.3 × 10−3 cm−1 by using an EH involving the {(054), (026), (125)} interacting states. The coupling of the (431) upper state with the (502) dark state was needed to account for the observed line positions of the 4ν1 + 3ν2 + ν3 band (rms = 5.7 × 10−3 cm−1).The dipole transition moment parameters were determined for the different observed bands. The obtained set of parameters and the experimentally determined energy levels were used to generate a complete line list provided as Supplementary Materials.The results of the analyses of the whole 5930–6900 cm−1 spectral region were gathered and used for a comparison of the band centres to their calculated values. The agreement achieved for both 18O3 and 16O3 (average difference on the order of 1 cm−1) indicates that the used potential energy surface provides accurate predictions up to a vibrational excitation approaching 80% of the dissociation energy. The comparison of the 18O3 and 16O3 band intensities is also discussed, opening a field of questions concerning the variation of the dipole moments and resonance intensity borrowing by isotopic substitution.  相似文献   

19.
The effect of indium-tin oxide (ITO) surface treatment on hole injection of devices with molybdenum oxide (MoO3) as a buffer layer on ITO was studied. The Ohmic contact is formed at the metal/organic interface due to high work function of MoO3. Hence, the current is due to space charge limited when ITO is positively biased. The hole mobility of N, N′-bis-(1-napthyl)-N, N′-diphenyl-1, 1′biphenyl-4, 4′-diamine (NPB) at various thicknesses (100–400 nm) has been estimated by using space-charge-limited current measurements. The hole mobility of NPB, 1.09×10−5 cm2/V s at 100 nm is smaller than the value of 1.52×10−4 cm2/V s at 400 nm at 0.8 MV/cm, which is caused by the interfacial trap states restricted by the surface interaction. The mobility is hardly changed with NPB thickness for the effect of interfacial trap states on mobility which can be negligible when the thickness is more than 300 nm.  相似文献   

20.
Proton NMR resonances of the endogenous metabolites creatine and phosphocreatine ((P)Cr), taurine (Tau), and carnosine (Cs, β-alanyl-l-histidine) were studied with regard to residual dipolar couplings and molecular mobility. We present an analysis of the direct 1H–1H interaction that provides information on motional reorientation of subgroups in these molecules in vivo. For this purpose, localized 1H NMR experiments were performed on m. gastrocnemius of healthy volunteers using a 1.5-T clinical whole-body MR scanner. We evaluated the observable dipolar coupling strength SD0 (S = order parameter) of the (P)Cr-methyl triplet and the Tau-methylene doublet by means of the apparent line splitting. These were compared to the dipolar coupling strength of the (P)Cr-methylene doublet. In contrast to the aliphatic protons of (P)Cr and Tau, the aromatic H2 (δ = 8 ppm) and H4 (δ = 7 ppm) protons of the imidazole ring of Cs exhibit second-order spectra at 1.5 T. This effect is the consequence of incomplete transition from Zeeman to Paschen-Back regime and allows a determination of SD0 from H2 and H4 of Cs as an alternative to evaluating the multiplet splitting which can be measured directly in high-resolution 1H NMR spectra. Experimental data showed striking differences in the mobility of the metabolites when the dipolar coupling constant D0 (calculated with the internuclear distance known from molecular geometry in the case of complete absence of molecular dynamics and motion) is used for comparison. The aliphatic signals involve very small order parameters S ≈ (1.4 − 3) × 10−4 indicating rapid reorientation of the corresponding subgroups in these metabolites. In contrast, analysis of the Cs resonances yielded S ≈ (113 − 137) × 10−4. Thus, the immobilization of the Cs imidazole ring owing to an anisotropic cellular substructure in human m. gastrocnemius is much more effective than for (P)Cr and Tau subgroups. Furthermore, 1H NMR experiments on aqueous model solutions of histidine and N-acetyl-l-aspartate (NAA) enabled the assignment of an additional signal component at δ = 8 ppm of Cs in vivo to the amide group at the peptide bond. The visibility of this proton could result from hydrogen bonding which would agree with the anticipated stronger motional restriction of Cs. Referring to the observation that all dipolar-coupled multiplets resolved in localized in vivo 1H NMR spectra of human m. gastrocnemius collapse simultaneously when the fibre structure is tilted towards the magic angle (θ ≈ 55°), a common model for molecular confinement in muscle tissue is proposed on the basis of an interaction of the studied metabolites with myocellular membrane phospholipids.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号