 共查询到20条相似文献,搜索用时 46 毫秒
1.
在自主研制的动态核极化(Dynamic Nuclear Polarization,DNP)分子影像装置的基础上,提出了一种集DNP和电子顺磁共振(Electron Paramagnetic Resonance,EPR)于一体的多功能谱仪,并对其中的关键部件之一--微波桥进行了设计.微波桥的引入,实现了DNP微波发射机的集成化,以及在DNP谱仪基础上的EPR功能扩展.通过结构设计、电路仿真及系统测试,完成了高频谱纯度、高动态范围的微波发射机以及低噪声系数的微波检测系统的设计与制作.并通过DNP增强实验以及连续波EPR实验对微波桥的性能进行了验证.  相似文献   

2.
We present a Q-band spectrometer which was built recently at the Institute of Physical Chemistry of the University of Stuttgart. It allows us to perform the field-sweep electron spin echo (ESE), pulsed electron–nuclear double resonance (ENDOR), relaxation and electron spin echo envelope modulation experiments both at room and low (down to 1.5 K) temperatures. The spectrometer consists of an electromagnet, digital field controller, pulsed microwave bridge, probehead, cryostat, radio frequency unit, pulse programmer and data acquisition electronics. The Q-band microwave bridge with 10.8 W output power is based on a two-stage IMPATT-diode pulse amplifier. The commercial Varian electromagnet system is controlled by a 24-bit home-built digital controller. The external devices are interfaced to the two PCs via GPIB and LAN. The spectrometer control software was developed in Visual C++. It consists of two programs running synchronously on the control PCs. The spectrometer is equipped with a cylindrical TE011 cavity constructed both for ESE and for pulsed ENDOR. The cavity fits into a liquid He cryostat thus allowing low-temperature experiments. An 8-bit data acquisition digitizer is used to collect the echo signals, and the PBESR-PRO-400 digital word generator orchestrates the pulse experiments and sets pulse sequences of the microwave bridge. The spectrometer performance is demonstrated on nitrogen impurities in a polycrystalline synthetic diamond, on silver clusters supported on NaA zeolite and electron-irradiated tooth enamel. Authors' address: Igor Tkach, Institute of Physical Chemistry, University of Stuttgart, Pfaffenwaldring 55, 70569 Stuttgart, Germany  相似文献   

3.
Overmodulation of electron paramagnetic resonance (EPR) lines is routinely used in EPR oximetry in order to increase the signal-to-noise ratio and thus to improve the accuracy with which the line width of a spin probe can be measured. For a known probe type, the line width is easily translated into the oxygen partial pressure. A standard EPR spectrometer uses the analog phase-sensitive detection (PSD) to demodulate the EPR signal. PSD imposes the restriction that only one spectrum is measured at a time, which is normally the first-harmonic EPR line. Information about EPR signals centered at the other harmonics of the modulation frequency is irreversibly destroyed by PSD. The question is raised whether this information can be utilized for EPR oximetry, for overmodulation enhances the second- and the other harmonic spectra, so that they approach the first-harmonic spectrum in intensity. To find an answer, numerical simulation and experimental measurements have been conducted. The experiment required modification of the detection scheme, so that all EPR-related information in the overmodulated signal is preserved. This permits measuring of the multiharmonic EPR spectrum, which when fitted to a set of the corresponding theoretical lines produces more accurate results in comparison with the standard overmodulation method.  相似文献   

4.
Reasons for unsatisfactory operation of the superheterodyne spectrometers at increased microwave power are considered. Recommendations for designing the superheterodyne microwave bridge of the EPR spectrometer working at the microwave power of about hundreds of milliwatt are given. These recommendations allow one to develop the spectrometer comparable to those with modulation of resonant conditions concerning reliability, stability and simplicity of operation. The experimental prototype of the coherent microwave bridge of the X-band superheterodyne EPR spectrometer with the intermediate frequency of 100 MHz is described. The microwave circuit of the bridge is assembled using microstrip hybrid integrated circuits and requires no adjustment in operation. The microwave Gunn-diode generators with the electronic tuning stabilized by dielectric resonators are used. The dynamic range of 54 dB at the maximum power of 40 mW is reached. As the microwave power increases up to the maximum value, no tendency to the degration of sensitivity equal to 5·10?11 W at the 40 MHz band is noticed.  相似文献   

5.
万谦  邹曦露 《波谱学杂志》1992,9(2):205-208
描述了一种延长EPR波谱仪中速调管使用寿命的方法.根据这种方法,只要正确地调谐微波桥的工作状态和适当地调整功率电平器的功率校正电平.即使对于已经严重老化的速调管仍然可以继续使用一段时间,维持仪器的正常运行.  相似文献   

6.
A spectrometer specifically designed for systematic studies of the spin dynamics underlying Dynamic Nuclear Polarization (DNP) in solids at low temperatures is described. The spectrometer functions as a fully operational NMR spectrometer (144 MHz) and pulse EPR spectrometer (95 GHz) with a microwave (MW) power of up to 300 mW at the sample position, generating a MW B(1) field as high as 800 KHz. The combined NMR/EPR probe comprises of an open-structure horn-reflector configuration that functions as a low Q EPR cavity and an RF coil that can accommodate a 30-50 μl sample tube. The performance of the spectrometer is demonstrated through some basic pulsed EPR experiments, such as echo-detected EPR, saturation recovery and nutation measurements, that enable quantification of the actual intensity of MW irradiation at the position of the sample. In addition, DNP enhanced NMR signals of samples containing TEMPO and trityl are followed as a function of the MW frequency. Buildup curves of the nuclear polarization are recorded as a function of the microwave irradiation time period at different temperatures and for different MW powers.  相似文献   

7.
An electron paramagnetic resonance (EPR) spectrometer is described which allows for continuous-wave and pulsed EPR experiments at 275 GHz (wavelength 1.1 mm). The related magnetic field of 9.9 T for g approximately 2 is supplied by a superconducting solenoid. The microwave bridge employs quasi-optical as well as conventional waveguide components. A cylindrical, single-mode cavity provides a high filling factor and a high sensitivity for EPR detection. Even with the available microwave power of 1 mW incident at the cavity a high microwave magnetic field B1 is obtained of about 0.1 mT which permits pi/2-pulses as short as 100 ns. The performance of the spectrometer is illustrated with the help of spectra taken with several samples.  相似文献   

8.
The Mark II W-band (94 GHz) EPR spectrometer with a low-noise millimeter-wave amplifier is described. The microwave bridge is of a high-sensitivity homodyne design. Signal-to-noise ratios were measured for a number of detectors with and without the low-noise amplifier. The signal-to-noise ratio was determined not only by the type of detector but also how well it was matched. Without a microwave preamplifier, a hot-electron bolometer provides the best signal-to-noise ratio. Addition of a low-noise microwave preamplifier to the CW homodyne bridge gives a 10 dB improvement in the noise figure of the receiver at a modulation frequency of 100 kHz. A greater improvement in the signal-to-noise ratio is seen at low modulation frequencies (1–10 kHz), making the low-noise amplifier useful for systems with large linewidths. This allows larger modulation amplitudes to be used without causing significant cavity heating or microphonics. The W-band spectrometer is capable of rapid sweeps from 0 to 7 T, as well as narrower (0.1 T) high-resolution sweeps. It is suitable for a wide variety of samples including liquids and samples cooled to sub-liquid-helium temperatures.  相似文献   

9.
The design and performance of the first commercial 94 GHz continuous-wave (CW-)/Fourier transform (FT-) EPR and ENDOR spectrometer are described. The spectrometer design is based on a heterodyne microwave bridge using an X-band intermediate frequency (IF), a hybrid magnet system, a variable-temperature, top-loading TeraFlex probehead with a TE011 cavity as well as the ELEXSYS-line digital electronics and the Xepr software package. The W-band bridge can be driven by a CW- or pulse-IF unit and delivers a microwave power of 5 mW at 94 GHz. In pulse mode the power is sufficient for a π/2 pulse of 100 ns at a resonatorQ-value of 3000. The magnet system consists of a 6 T split-coil superconducting magnet and a water-cooled room-temperature coil. The main coil can be swept over the full range from 0 to 6 T. The room-temperature coil has a 800 G sweep range around the persistent field of the main magnet. The ENDOR probe features a tuned circuit for1H nuclei allowing an RF π-pulse of 8 μs with a 200 W amplifier. A broad-band setup is used for other nuclei. The E680 FT-EPR system utilizes the PatternJet pulse programmer and the SpecJet high-speed transient signal averager. The concerted action of these two devices results in a pulse EPR sensitivity equal or higher than in CW-EPR. Selected examples indicating the performance of the 94 GHz CW/FT-EPR and ENDOR systems are shown.  相似文献   

10.
A computer-controlled X-band time domain electron paramagnetic resonance (EPR) spectrometer, with a time resolution of the order of 0.5μsec, has been constructed with many of the crucial microwave components designed and fabricated by the Microwave Engineering Group of TIFR. The spectrometer operates either in a microwave power pulsed mode for determination of spin-lattice relaxation times by the saturation recovery technique or in the kinetic mode for determination of the time dependence of EPR signal after laser excitation. It has an automatic frequency control, an automatic phase control and, most importantly, a field-frequency lock which ensures good stability of the EPR line positions enabling signal averaging for extended periods. The constructional details of the spectrometer and its performance in both the modes are described here by reporting results on certain typical systems.  相似文献   

11.
A new setup for longitudinal detection (LOD) of EPR signals based on a commercial pulse EPR spectrometer equipped with an ENDOR probehead is presented. The design is suited for pulse LOD EPR and amplitude-modulated cw LOD EPR experiments. The sensitivity is substantially increased compared with earlier designs. Two new pulse schemes that take full advantage of the special properties of the setup are invented. In transient-nutation longitudinally detected EPR (TN-LOD EPR), the nutation of magnetization during a microwave pulse is used to measure the EPR signal. In pulse-train excited longitudinally detected EPR (PT-LOD EPR), a train of microwave pulses that periodically inverts the magnetization is applied. First experimental results on radicals and metal complexes at room temperature are presented.  相似文献   

12.
Microwave absorption studies have been carried out on MgB2 superconductor using a standard X-band EPR spectrometer. The modulated low-field microwave absorption signals recorded for polycrystalline (grain size ∼ 10 μm) samples suggested the absence of weak-link character. The field dependent direct microwave absorption has been found to obey a ✓H dependence with two different slopes, which indicated a transition from strongly pinned lattice to flux flow regime.  相似文献   

13.
A digital EPR spectrometer was constructed by replacing the traditional bridge with an arbitrary waveform generator (AWG) to produce excitation patterns and a high-speed digitizer for direct detection of the spin system response at the carrier frequency. Digital down-conversion produced baseband signals in quadrature with very precise orthogonality. Real-time resonator tuning was performed by monitoring the Fourier transforms of signals reflected from the resonator during frequency sweeps generated by the AWG. The capabilities of the system were demonstrated by rapid magnetic field scans at 256 MHz carrier frequency, and FID and spin echo experiments at 1 and 10 GHz carrier frequencies. For the rapid scan experiments the leakage through a cross-loop resonator was compensated by adjusting the amplitude and phase of a sinusoid at the carrier frequency that was generated with another AWG channel.  相似文献   

14.
核磁共振谱仪技术中的高速数据采集   总被引:4,自引:2,他引:2  
采用Burr-Brown 公司的10MHz、12Bit A/D采样器件设计了一块基于PC总线的高速A/D采集卡,给出了核磁共振实验结果,并讨论了高速ADC在谱仪简化设计中的应用.  相似文献   

15.
V. F. Tarasov 《JETP Letters》1998,68(5):394-399
A resonance change in microwave absorption in zero magnetic field, which is not due to magnetic-field dependence of the energy levels of the spin systems, is observed for a number of non-Kramers paramagnetic ions (Cr2+, Ni2+, Fe2+) in synthetic forsterite. It is shown that these signals could be due to narrowing of the homogeneous spin packet of an inhomogeneously broadened EPR line in zero magnetic field. Pis’ma Zh. éksp. Teor. Fiz. 68, No. 5, 370–375 (10 September 1998)  相似文献   

16.
A quadrature digital receiver and associated signal estimation procedure are reported for L-band electron paramagnetic resonance (EPR) spectroscopy. The approach provides simultaneous acquisition and joint processing of multiple harmonics in both in-phase and out-of-phase channels. The digital receiver, based on a high-speed dual-channel analog-to-digital converter, allows direct digital down-conversion with heterodyne processing using digital capture of the microwave reference signal. Thus, the receiver avoids noise and nonlinearity associated with analog mixers. Also, the architecture allows for low-Q anti-alias filtering and does not require the sampling frequency to be time-locked to the microwave reference. A noise model applicable for arbitrary contributions of oscillator phase noise is presented, and a corresponding maximum-likelihood estimator of unknown parameters is also reported. The signal processing is applicable for Lorentzian lineshape under nonsaturating conditions. The estimation is carried out using a convergent iterative algorithm capable of jointly processing the in-phase and out-of-phase data in the presence of phase noise and unknown microwave phase. Cramér-Rao bound analysis and simulation results demonstrate a significant reduction in linewidth estimation error using quadrature detection, for both low and high values of phase noise. EPR spectroscopic data are also reported for illustration.  相似文献   

17.
This paper investigates basic characteristics of the electron paramagnetic resonance (EPR) signal obtained from spectrometers employing reflection resonators. General equations are presented which reveal the phase and amplitude dependence on instrumental parameters of both components of the continuous wave (CW) EPR signal (absorption and dispersion). New phase vector diagrams derived from these general equations are presented for the analysis of the EPR response. The dependence of the phase and absolute value of the CW EPR signal on the local oscillator (LO) phase and on resonator offset and coupling is presented and analyzed. The EPR spectrometer tuning procedures for both balanced and unbalanced heterodyne receivers are analyzed in detail using the new phase diagrams. Extraneous signals at the RF input of the microwave receiver (resulting from circulator leakage and reflections in the resonator transmission line) have been taken into account and analyzed. It is shown that a final tuning condition that corresponds to an extremum of the receiver output as a function of the resonator frequency is necessary and sufficient for the acquisition of pure absorption signal. This condition is universal: it applies to all spectrometer configurations in all frequency ranges. High Frequency EPR spectrometer (130 GHz) data are used to generate experimental phase diagrams that illustrate the theoretical concepts presented in the paper. Conditions are presented under which the absorption signal can be measured with complete suppression of the dispersion, independent of the mutual frequency offset between the microwave source and the EPR sample resonator. Equations describing the approximate relationship between changes of the resonator properties (Q-factor and frequency) and paramagnetic susceptibility are derived and analyzed.  相似文献   

18.
Stochastic excitation with a full-width-half-maximum bandwidth of 250 MHz was used to perform Fourier-transform (FT) high-field/high-frequency electron paramagnetic resonance (EPR) at 3.4T/95 GHz (W-band). Thereby, the required microwave peak power is reduced by a factor of tau(p)/T1 as compared to equivalent pulsed FT EPR in which the spin system with spin-lattice relaxation time T1 is excited by a single microwave pulse of length tau(p). Stochastic EPR is particularly interesting under high-field/high-frequency conditions, because the limited output power of mm microwave sources, amplifiers, and mixers makes pulse FT EPR in that frequency domain impossible, at least for the near future. On the other hand, FT spectroscopy offers several advantages compared to field-swept magnetic resonance methods, as is demonstrated by its success in NMR and X-band EPR. In this paper we describe a novel stochastic W-band microwave bridge including a bimodal induction mode transmission resonator that serves for decoupling the microwave excitation and signal detection. We report first EPR measurements and discuss experimental difficulties as well as achieved sensitivity. Moreover, we discuss future improvements and the possibility for an application of stochastic W-band FT EPR to transient signals such as those of photoexcited radical pairs in photosynthetic reaction centers.  相似文献   

19.
Direct detection of free induction decays and electron spin echoes, and the recording of echo-detected EPR spectra and electron spin echo envelope modulation patterns at a microwave frequency of 2.5 GHz is demonstrated. This corresponds to the measurement of the transverse magnetization in the laboratory frame, rather than in the rotating frame as usually done by down-converting the signal (homodyne detection). An oscilloscope with a 6-GHz analog bandwidth, a sampling rate of 20 GigaSamples per second, and a trigger frequency of 5 GHz for the edge trigger and 750 MHz for the advanced trigger, is used in these experiments. For signal averaging a 3-GHz microwave clock divider has been developed to synchronize the oscilloscope with the frequency of the EPR signal. Moreover, direct detection of continuous wave EPR signals at 2.5 GHz is described.  相似文献   

20.
Bragg cut-off for plane of polycrystalline beryllium of various lengths of 300 and 116 K has been measured with an energy resolution of 5 μeV. The natural width of the cut-off is 12.5±1.5 μeV, independent of temperature and length of beryllium and also of physical characteristics and certain metallurgical treatments of the powder. Such blocks of beryllium would be suitable for designing a ΔT-window spectrometer with resolution ⩾20 μeV. Bragg cut-offs corresponding to (0002) and planes of beryllium have been separated for the first time. These can also be used for producing additional energy windows in a ΔT-window spectrometer, thus increasing its efficiency. Paper entitled ‘ΔT-window spectrometer’ will appear in the November issue of Pramana.  相似文献   