首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Effect of masker level on overshoot   总被引:5,自引:0,他引:5  
Overshoot refers to the phenomenon where signal detectability improves for a short-duration signal as the onset of that signal is delayed relative to the onset of a longer duration masker. A popular explanation for overshoot is that it reflects short-term adaptation in auditory-nerve fibers. In this study, overshoot was measured for a 10-ms, 4-kHz signal masked by a broadband noise. In the first experiment, masker duration was 400 ms and signal onset delay was 1 or 195 ms; masker spectrum level ranged from - 10-50 dB SPL. Overshoot was negligible at the lowest masker levels, grew to about 10-15 dB at the moderate masker levels, but declined and approached 0 dB at the highest masker levels. In the second experiment, the masker duration was reduced to 100 ms, and the signal was presented with a delay of 1 or 70 ms; masker spectrum level was 10, 30, or 50 dB SPL. Overshoot was about 10 dB for the two lower masker levels, but about 0 dB at the highest masker level. The results from the second experiment suggest that the decline in overshoot at high masker levels is probably not due to auditory fatigue. It is suggested, instead, that the decline may be attributable to the neural response at high levels being dominated by those auditory-nerve fibers that do not exhibit short-term adaptation (i.e., those with low spontaneous rates and high thresholds).  相似文献   

2.
Release from masking caused by envelope fluctuations   总被引:1,自引:0,他引:1  
This paper examines how short-term energy fluctuations in a masker affect the thresholds for tones at frequencies above those of the masker. Two equally intense tones at 1060 and 1075 Hz produce up to 25 dB less masking than does a 1075-Hz tone set to the overall level of the two-tone complex. At wider frequency separations, two-tone complexes also produce less masking than the pure tone. These results indicate that envelope fluctuations in a masker, whose spectrum is confined to a single critical band, may result in release from masking. The release from masking probably is related to the comodulation masking release reported by Hall et al. [J. Acoust. Soc. Am. 76, 50-56 (1984b)] for modulated-noise maskers with bandwidths greater than one critical band. Further measurements with maskers, whose intensity level in the critical band around 1 kHz was 90 dB SPL, show similar masking by a pure tone and a 625- to 1075-Hz bandpass noise, but less masking by narrow-band noises. These results are inconsistent with a simple frequency selective energy-detector model and indicate that the auditory system can use periods of low masker energy as brief as a few ms to enhance detection of a tone. The results also imply that the upward spread of excitation is best represented by masking patterns for noises with bandwidths of several critical bands.  相似文献   

3.
These experiments examine how comodulation masking release (CMR) varies with masker bandwidth, modulator bandwidth, and signal duration. In experiment 1, thresholds were measured for a 400-ms, 2000-Hz signal masked by continuous noise varying in bandwidth from 50-3200 Hz in 1-oct steps. In one condition, using random noise maskers, thresholds increased with increasing bandwidth up to 400 Hz and then remained approximately constant. In another set of conditions, the masker was multiplied (amplitude modulated) by a low-pass noise (bandwidth varied from 12.5-400 Hz in 1-oct steps). This produced correlated envelope fluctuations across frequency. Thresholds were generally lower than for random noise maskers with the same bandwidth. For maskers less than one critical band wide, the release from masking was largest (about 5 dB) for maskers with low rates of modulation (12.5-Hz-wide low-pass modulator). It is argued that this release from masking is not a "true" CMR but results from a within-channel cue. For broadband maskers (greater than 400 Hz), the release from masking increased with increasing masker bandwidth and decreasing modulator bandwidth, reaching an asymptote of 12 dB for a masker bandwidth of 800 Hz and a modulator bandwidth of 50 Hz. Most of this release from masking can be attributed to a CMR. In experiment 2, the modulator bandwidth was fixed at 12.5 Hz and the signal duration was varied. For masker bandwidths greater than 400 Hz, the CMR decreased from 12 to 5 dB as the signal duration was decreased from 400 to 25 ms.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

4.
The purpose of this report is to present new data that provide a novel perspective on temporal masking, different from that found in the classical auditory literature on this topic. Specifically, measurement conditions are presented that minimize rather than maximize temporal spread of masking for a gated (200-ms) narrow-band (405-Hz-wide) noise masker logarithmically centered at 2500 Hz. Masked detection thresholds were measured for brief sinusoids in a two-interval, forced-choice (21FC) task. Detection was measured at each of 43 temporal positions within the signal observation interval for the sinusoidal signal presented either preceding, during, or following the gating of the masker, which was centered temporally within each 500-ms observation interval. Results are presented for three listeners; first, for detection of a 1900-Hz signal across a range of masker component levels (0-70 dB SPL) and, second, for masked detection as a function of signal frequency (fs = 500-5000 Hz) for a fixed masker component level (40 dB SPL). For signals presented off-frequency from the masker, and at low-to-moderate masker levels, the resulting temporal masking functions are characterized by sharp temporal edges. The sharpness of the edges is accentuated by complex patterns of temporal overshoot and undershoot, corresponding with diminished and enhanced detection, respectively, at both masker onset and offset. This information about the onset and offset timing of the gated masker is faithfully represented in the temporal masking functions over the full decade range of signal frequencies (except for fs=2500 Hz presented at the center frequency of the masker). The precise representation of the timing information is remarkable considering that the temporal envelope characteristics of the gated masker are evident in the remote masking response at least two octaves below the frequencies of the masker at a cochlear place where little or no masker activity would be expected. This general enhancement of the temporal edges of the masking response is reminiscent of spectral edge enhancement by lateral suppression/inhibition.  相似文献   

5.
Thresholds for the detection of harmonic complex tones in noise were measured as a function of masker level. The rms level of the masker ranged from 40 to 70 dB SPL in 10-dB steps. The tones had a fundamental frequency (F0) of 62.5 or 250 Hz, and components were added in either cosine or random phase. The complex tones and the noise were bandpass filtered into the same frequency region, from the tenth harmonic up to 5 kHz. In a different condition, the roles of masker and signal were reversed, keeping all other parameters the same; subjects had to detect the noise in the presence of a harmonic tone masker. In both conditions, the masker was either gated synchronously with the 700-ms signal, or it started 400 ms before and stopped 200 ms after the signal. The results showed a large asymmetry in the effectiveness of masking between the tones and noise. Even though signal and masker had the same bandwidth, the noise was a more effective masker than the complex tone. The degree of asymmetry depended on F0, component phase, and the level of the masker. The maximum difference between masked thresholds for tone and noise was about 28 dB; this occurred when the F0 was 62.5 Hz, the components were in cosine phase, and the masker level was 70 dB SPL. In most conditions, the growth-of-masking functions had slopes close to 1 (on a dB versus dB scale). However, for the cosine-phase tone masker with an F0 of 62.5 Hz, a 10-dB increase in masker level led to an increase in masked threshold of the noise of only 3.7 dB, on average. We suggest that the results for this condition are strongly affected by the active mechanism in the cochlea.  相似文献   

6.
The influence of the degree of envelope modulation and periodicity on the loudness and effectiveness of sounds as forward maskers was investigated. In the first experiment, listeners matched the loudness of complex tones and noise. The tones had a fundamental frequency (F0) of 62.5 or 250 Hz and were filtered into a frequency range from the 10th harmonic to 5000 Hz. The Gaussian noise was filtered in the same way. The components of the complex tones were added either in cosine phase (CPH), giving a large crest factor, or in random phase (RPH), giving a smaller crest factor. For each F0, subjects matched the loudness between all possible stimulus pairs. Six different levels of the fixed stimulus were used, ranging from about 30 dB SPL to about 80 dB SPL in 10-dB steps. Results showed that, at a given overall level, the CPH and the RPH tones were louder than the noise, and that the CPH tone was louder than the RPH tone. The difference in loudness was larger at medium than at low levels and was only slightly reduced by the addition of a noise intended to mask combination tones. The differences in loudness were slightly smaller for the higher than for the lower F0. In the second experiment, the stimuli with the lower F0s were used as forward maskers of a 20-ms sinusoid, presented at various frequencies within the spectral range of the maskers. Results showed that the CPH tone was the least effective forward masker, even though it was the loudest. The differences in effectiveness as forward maskers depended on masker level and signal frequency; in order to produce equal masking, the level of the CPH tone had to be up to 35 dB above that of the RPH tone and the noise. The implications of these results for models of loudness are discussed and a model is presented based on neural activity patterns in the auditory nerve; this predicts the general pattern of loudness matches. It is suggested that the effects observed in the experiments may have been influenced by two factors: cochlear compression and suppression.  相似文献   

7.
Detection thresholds for a tone in an unfamiliar tonal pattern can be greatly elevated under conditions of masker uncertainty [Neff and Green, Percept. Psychophys. 41, 409-415 (1987); Oh and Lutfi, J. Acoust. Soc. Am. 101, 3148 (1997)]. The present experiment was undertaken to determine whether harmonicity of masker tones can reduce the detrimental effect of masker uncertainty. Inharmonic maskers were comprised of m=2-49 frequency components selected at random on each presentation within 100-10000 Hz, excluding frequencies between 920-1080. Harmonic maskers were comprised of frequency components selected at random within this same range, but constrained to have a fundamental frequency of 200 Hz. For inharmonic maskers the signal was a 1000-Hz tone. For harmonic-maskers the signal was a tone whose frequency was either harmonically (1000 Hz) or inharmonically (1047 Hz) related to the masker. In all conditions the amount of masking was greatest for m = 20-40 components. At this point, harmonic maskers with harmonic signal produced an average of 9-12 dB less masking than inharmonic maskers. Harmonic maskers with inharmonic signal produced an average of 16-20 dB less masking.  相似文献   

8.
Psychometric functions (PFs) for forward-masked tones were obtained for conditions in which signal level was varied to estimate threshold at several masker levels (variable-signal condition), and in which masker level was varied to estimate threshold at several signal levels (variable-masker condition). The changes in PF slope across combinations of masker frequency, masker level, and signal delay were explored in three experiments. In experiment 1, a 2-kHz, 10-ms tone was masked by a 50, 70 or 90 dB SPL, 20-ms on-frequency forward masker, with signal delays of 2, 20, or 40 ms, in a variable-signal condition. PF slopes decreased in conditions where signal threshold was high. In experiments 2 and 3, the signal was a 4-kHz, 10-ms tone, and the masker was either a 4- or 2.4-kHz, 200-ms tone. In experiment 2, on-frequency maskers were presented at 30 to 90 dB SPL in 10-dB steps and off-frequency maskers were presented at 60 to 90 dB SPL in 10-dB steps, with signal delays of 0, 10, or 30 ms, in a variable-signal condition. PF slopes decreased as signal level increased, and this trend was similar for on- and off-frequency maskers. In experiment 3, variable-masker conditions with on- and off-frequency maskers and 0-ms signal delay were presented. In general, the results were consistent with the hypothesis that peripheral nonlinearity is reflected in the PF slopes. The data also indicate that masker level plays a role independent of signal level, an effect that could be accounted for by assuming greater internal noise at higher stimulus levels.  相似文献   

9.
The present study sought to clarify the role of non-simultaneous masking in the binaural masking level difference for maskers that fluctuate in level. In the first experiment the signal was a brief 500-Hz tone, and the masker was a bandpass noise (100-2000 Hz), with the initial and final 200-ms bursts presented at 40-dB spectrum level and the inter-burst gap presented at 20-dB spectrum level. Temporal windows were fitted to thresholds measured for a range of gap durations and signal positions within the gap. In the second experiment, individual differences in out of phase (NoSπ) thresholds were compared for a brief signal in a gapped bandpass masker, a brief signal in a steady bandpass masker, and a long signal in a narrowband (50-Hz-wide) noise masker. The third experiment measured brief tone detection thresholds in forward, simultaneous, and backward masking conditions for a 50- and for a 1900-Hz-wide noise masker centered on the 500-Hz signal frequency. Results are consistent with comparable temporal resolution in the in phase (NoSo) and NoSπ conditions and no effect of temporal resolution on individual observers' ability to utilize binaural cues in narrowband noise. The large masking release observed for a narrowband noise masker may be due to binaural masking release from non-simultaneous, informational masking.  相似文献   

10.
The present investigation assessed the simultaneous and temporal masking produced by computer-generated synthetic vowels. The durations (100 and 200 ms) of each of four vowel-like maskers were employed. The masker was presented at 70 dB SPL. The probe signals were three filtered noise bursts whose spectral distributions corresponded to regions of high spectral energy in three English stop consonants. Quiet and masked thresholds were determined using the method of adjustment. Data are reported for two experienced listeners who participated in all the listening conditions. The results were generally in accord with the results of masking experiments using nonspeech signals in that both the frequency specificity of masking and temporal masking effects were demonstrated.  相似文献   

11.
In forward masking, performance may be affected by confusion, that is, by the difficulty of discriminating a suprathreshold signal from the preceding masker. This study investigated confusion effects for forward maskers composed of repeated bursts of a 100-Hz sinusoid followed by sinusoidal signals; such "pulsing" maskers produce confusion when the properties of the signal are identical to those of an individual masker "pulse." The level, frequency, and duration of the signal relative to an individual masker pulse, as well as offset-onset delay, were varied to determine the minimum change necessary to eliminate confusion. For maskers composed of 20-ms pulses, confusion was eliminated by changes in signal level of 5 dB or changes in signal frequency of 30 to 40 Hz. For maskers composed of 10-, 20-, or 40-ms pulses, confusion was eliminated by signal delays of 8 to 16 ms or by signal durations less than half or greater than twice the masker-pulse duration. Results with adaptive procedures designed to measure confusion-free or confusion-determined thresholds suggest that confusion effects can be minimized or avoided by extensive listener training with a procedure in which the signal and masker are not presented at similar intensities.  相似文献   

12.
Fastl and Bechly [J. Acoust. Soc. Am. 74, 754-757 (1983)] reported that the threshold of a brief 900-Hz signal simultaneously masked by a band of noise. 100 Hz wide, centered at 1000 Hz, was reduced by approximately 8 dB by the addition of an 1150-Hz tone having a level of 20 dB above that of the narrow-band masker. They concluded that this decrease in threshold was a demonstration of suppression in simultaneous masking. Here it is argued that Fastl and Bechly's results simply reflect the poorer detectability of signals masked by higher-frequency fluctuating maskers (their narrow-band masker) than by relatively flat-envelope maskers (their composite narrow-band plus tonal masker). The results of three experiments support the masker-envelope explanation. In the first experiment, as in the report of Fastl and Bechly, the masker centered at 1000 Hz (M1) was a narrow-band noise and the masker centered at 1150 Hz (M2) was a tone. Fastl and Bechly's result was replicated. However, thresholds obtained when M1 was presented alone (the M1-only condition) were more affected by the starting level of the signal within each adaptive track than were thresholds obtained when M1 and M2 were presented together (the M1+M2 condition). This result paralleled a previous report that starting level influenced performance more with fluctuating than with flat-envelope maskers. For the four of seven subjects wh showed learning, there was also more improvement in the M1-only than in the M1 + M2 condition. In the second experiment, M1 was a tone and M2 was a narrow-band noise.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

13.
The overshoot effect can be reduced by temporary hearing loss induced by aspirin or exposure to intense sound. The present study simulated a hearing loss at 4.0 kHz via pure-tone forward masking and examined the effect of the simulation on threshold for a 10-ms, 4.0-kHz signal presented 1 ms after the onset of a 400-ms, broadband noise masker whose spectrum level was 20 dB SPL. Masker frequency was 3.6, 4.0, or 4.2 kHz, and masker level was 80 dB SPL. Subject-dependent delays were determined such that 10 or 20 dB of masking at 4.0 kHz was produced. In general, the pure-tone forward masker did not reduce the simultaneous-masked threshold, suggesting that elevating threshold with a pure-tone forward masker does not sufficiently simulate the effect of a temporary hearing loss on overshoot.  相似文献   

14.
15.
Simultaneous masking of a 20-ms, 1-kHz signal was investigated using 50-ms gated and continuous sinusoidal maskers with frequencies below, at, and above 1 kHz. Gated maskers can produce considerably (5-20 dB) more masking than continuous maskers, and this difference does not appear to result from the spread of energy produced by gating either the masker or the signal. For masker frequencies below the signal frequency, this difference in masking is primarily due to the detection of the cubic difference tone in the continuous condition. For masker frequencies at and above the signal frequency, the difference appears to be an important property of masking. Implications of this frequency-dependent effect for measures of frequency selectivity are discussed.  相似文献   

16.
The effective internal level of a 1-kHz tone at 50 dB SPL was estimated by measuring the forward masking produced on a 10-ms signal tone of the same frequency. Noise containing a spectral notch was then added to the masker tone, and its influence on the effective level of the tone was measured with a variety of noise levels, notch widths, and notch shapes. In experiment 1, the masker tone was centered in the spectral notch, itself centered in a 2-kHz band of noise. As the spectrum level in the noise passbands increased from 6 dB/Hz to 36 dB/Hz, signal threshold decreased, indicating a decrease in masking by the masker tone. This "unmasking" effect of the noise was attributed to suppression of the masker tone by the components in the noise. Unmasking was greatest with the narrowest spectral notch (250 Hz), and decreased to zero as the notch widened to 1500 Hz. Compared to its level when presented alone, the effective internal level of the masker tone could be reduced by up to 30 dB (250-Hz notch, 36 dB/Hz). The relative suppressive strength of individual noise components was estimated in experiment 2, in which the 1-kHz masker tone was located at one edge of a spectral notch, rather than in the center. Noise spectrum level was fixed at 16 dB/Hz. As notch width decreased to zero, on either the high-frequency or low-frequency side of the masker tone, its effective internal level was again reduced by approximately 30 dB. In a tentative analysis, the first derivative of the smoothed threshold function was taken, to provide an estimate of the relative contributions to suppression at 1 kHz of noise components between 250 and 1740 Hz.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

17.
Overshoot was measured in both ears of four subjects with normal hearing and in five subjects with permanent, sensorineural hearing loss (two with a unilateral loss). The masker was a 400-ms broadband noise presented at a spectrum level of 20, 30, or 40 dB SPL. The signal was a 10-ms sinusoid presented 1 or 195 ms after the onset of the masker. Signal frequency was 1.0 or 4.0 kHz, which placed the signal in a region of normal (1.0 kHz) or impaired (4.0 kHz) absolute sensitivity for the impaired ears. For the normal-hearing subjects, the effects of signal frequency and masker level were similar to those published previously. In particular, overshoot was larger at 4.0 than at 1.0 kHz, and overshoot at 4.0 kHz tended to decrease with increasing masker level. At 4.0 kHz, overshoot values were significantly larger in the normal ears: Maximum values ranged from about 7-26 dB in the normal ears, but were always less than 5 dB in the impaired ears. The smaller overshoot values resulted from the fact that thresholds in the short-delay condition were considerably better in the hearing-impaired subjects than in the normal-hearing subjects. At 1.0 kHz, overshoot values for the two groups of subjects more or less overlapped. The results suggest that permanent, sensorineural hearing loss disrupts the mechanisms responsible for a large overshoot effect.  相似文献   

18.
The purpose of this investigation was to examine two stimulus parameters that were reasoned to be of importance to comodulation masking release (CMR). The first was the degree of fluctuation, or depth of modulation, in the masker bands, and the second was the temporal position of the signal with respect to the modulations of the masker. The investigation began by demonstrating the efficacy of sinusoidally amplitude-modulated (SAM) tonal complex maskers in eliciting CMR. "Nine-band" maskers, 650 ms in duration, were constructed by adding together nine SAM tones spaced at 100-Hz intervals from 300 to 1100 Hz. The rate of modulation for each SAM tone was 10 Hz, and the depth of modulation was 100%. Using such maskers, it was shown that when the on-frequency SAM tone had a modulation depth of 100%, the threshold for a 250-ms, 700-Hz tone improved monotonically as the modulation depths of the flanking SAM tones increased from 0% to 100%. When the on-frequency SAM tone had a modulation depth of 63%, some listeners performed optimally when the flanking SAM tones also exhibited a modulation depth of 63%, whereas others performed best when the flankers had modulation depths of 100%. With regard to signal position, a typical CMR effect was observed when the signal, consisting of a train of three 50-ms, 700-Hz tone bursts, was placed in the dips of the on-frequency masker. However, when the signal was placed at the peaks of the envelope, an increase in masking was observed for a comodulated masker.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

19.
Thresholds were measured for detection of an increment in level of a 60-dB SPL target tone at 1 kHz, either in quiet or in the presence of maskers at 0.5 and 2 kHz. Interval-by-interval level rove applied independently to remote masker tones substantially elevated thresholds compared to intensity discrimination in quiet, an effect on the order of 10+dB [10 log(DeltaII)]. Asynchronous onset and stimulus envelope mismatches across frequency reduced but did not eliminate masking. A preinterval cue to signal frequency had no effect, but cuing masker frequency reduced thresholds, whether or not masker level was also cued. About 1 to 2 dB of threshold elevation in these conditions can be attributed to energetic masking. Decreasing the overall presentation level and increasing masker separation essentially eliminates energetic masking; under these conditions masker level rove elevates thresholds by approximately 7 dB when the target and masker tones are gated synchronously. This masking persists even when the flanking masker tones are presented contralateral to the target. Results suggest that observers tend to listen synthetically, even in conditions when this strategy reduces sensitivity to the intensity increment.  相似文献   

20.
A series of experiments evaluated the effects of broadband noise (ipsilateral) on wave V of the brainstem auditory evoked response (BAER) elicited by tone bursts or clicks in the presence of high-pass masking noise. Experiment 1 used 1000- and 4000-Hz, 60-dB nHL tone bursts in the presence of broadband noise. With increasing noise level, wave V latency shift was greater for the 1000-Hz tone bursts, while amplitude decrements were similar for both tone-burst frequencies. Experiment 2 varied high-pass masker cutoff frequency and the level of subtotal masking in the presence of 50-dB nHL clicks. The effects of subtotal masking on wave V (increase in latency and decrease in amplitude) increased with increasing derived-band frequency. Experiment 3 covaried high-pass masker cutoff frequency and subtotal masking level for 1000- and 4000-Hz tone-burst stimuli. The effect of subtotal masking on wave V latency was reduced for both tone-burst frequencies when the response-generating region of the cochlear partition was limited by high-pass maskers. The results of these three experiments suggest that most of the wave V latency shift associated with increasing levels of broadband noise is mediated by a place mechanism when the stimulus is a moderate intensity (60 dB nHL), low-frequency (1000 Hz) tone burst. However, the interpretation of the latency shifts produced by broadband noise for 4000-Hz tone-burst stimuli is made more complex by multiple technical factors discussed herein.  相似文献   