首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 250 毫秒
1.
The kinetics of formation and dissociation reactions of [Ru(CN)5L]3– with a series of heterocyclic ligands were studied in aqueous media. In this presence of an excess of heterocycle, the observed second order rate constants were calculated from the kobs versus [ligand] plot at =0.100m NaClO4. Activation parameters for the formation reactions (H=28±7kJmol–1 and S=140±35JK–1mol–1) are comparable for all systems, indicating a common mechanism. The kinetics of exchange of coordinated heterocycles for 1,3,5-triazine yielded a rate saturation typical of a limiting dissociative mechanism. Activation parameters of the limiting first order specific rate of dissociation reactions were H=85±7kJmol–1 and S=18±4JK–1mol–1. Equilibrium constants were calculated from the second order rates of formation and pseudo-first order rates of dissociation reaction.  相似文献   

2.
This study aims to investigate the distribution of Na, K, Rb and Cs in human brains (5 individuals, 12 brain parts, mean age: 75 years). Distribution of the trace metals between lipid fraction and brain tissue was investigated in solvent extraction experiments. Determinations were carried out by instrumental neutron activation analysis. The present results show a rather non-homogeneous distribution for Na and a relatively uniform distribution for K, Rb and Cs. The mean concentrations found are 7440µgNag–1 dry weight, 12800µgKg–1, 14µgRbg–1 and 50ngCsg–1. A highly significant positive correlation was found between Rb and Cs. Solvent extraction experiments showed that 19% of Rb and 26% of Cs of the total content is located in lipid fraction.  相似文献   

3.
A microcolumn on-line preconcentration and separation system was developed for the flame atomic absorption spectrometric (FAAS) determination of trace levels of gold and palladium. The analytes were selectively adsorbed onto the microcolumn packed with 2-mercaptothiazole immobilized silica gel (MBTSG) in an acidity range of 0.1 to 6.0M HCl at a sampling flow rate of 4.0mLmin–1. The analytes adsorbed could be desorbed by a thiourea solution with a flow rate of 2.0mLmin–1. Most of the common coexisting metal ions at a concentration of 25.0mgmL–1 and anions at a concentration of 50.0mgmL–1 did not interfere with the preconcentration and determination of Au and Pd. The limits of detection (LOD), defined as three times the standard deviation of the blank (3), of Au and Pd are 10ngmL–1 and 26ngmL–1, respectively, with a preconcentration time of 60s. The relative standard deviation (RSD) is about 2.0% for 0.20µgmL–1 Au and 0.30µgmL–1 Pd. With a sample loading time of 30min, 6.7ngmL–1 Au and 10ngmL–1 Pd can be preconcentrated quantitatively. A geological sample, an anode slime and a secondary nickel alloy were successfully determined with the proposed method, and the results obtained showed good agreement with the certified values.Received December 23, 2002; accepted May 14, 2003 Published online August 8, 2003  相似文献   

4.
A novel chromogenic reagent, 2-(2-sulfo-4-acetylphenylazo)-7-(2,4,6-trichlorophenylazo)-1,8-dihydroxynaphthalene-3,6-disulfonic acid 1, was prepared by diazo coupling of 4-acetylaniline-2-sulfonic acid and 2,4,6-trichloroaniline to chromotropic acid through –N=N– groups. Based on this reagent, a simple, sensitive and selective spectrophotometric method was developed for the determination of lead. In 0.20M phosphoric acid medium, lead reacts with 1 to form a 1:2 blue complex with an absorption maximum of 654nm. Beers law is obeyed in the range of 0–0.6mgL–1 of lead. The apparent molar absorptivity is 1.25×105Lmol–1cm–1. The detection limit and quantification limit were found to be 0.63µgL–1 and 2.1µgL–1, respectively. The relative standard deviation for eleven replicate measurements was of 2.6%. The interference of foreign ions was also investigated. All the other foreign ions studied did not interfere with lead determination except for Ca(II) and Ba(II). The interference caused by Ca(II) and Ba(II) can be eliminated by prior extraction of lead with potassium iodide-methylisobutylketone (KI-MIBK). The proposed method was applied to the determination of lead in certified samples with satisfactory results.  相似文献   

5.
Thallium in natural water samples was determined by electrothermal atomic absorption spectrometry after 1000-fold enrichment by mini solid-phase extraction from a 100-mL sample solution. A Tl-pyrrolidine-1-carbodithioate complex formed in a sample solution of pH 1.6 was extracted on fine particles of a cellulose nitrate resin dispersed in the sample solution. The cellulose nitrate resin was then collected on a membrane filter (25mmø) by filtration under suction using a glass funnel with an effective filtration area of 0.64cm2. As a result, a circular thin layer of the resin phase with a diameter of 9mm was obtained. Then the resin phase was carved out by an acrylate resin puncher with a 10-mmø hole to put it into a sample cup containing 100µL of 10mM HNO3 containing 0.5mM NaCl. The resin phase was suspended in the solution by ultrasonication. 1000-fold enrichment was thus attained within 15min, and the suspension was delivered to electrothermal atomic absorption spectrometry. The linear calibration graph was obtained in the range of 0–4ng of Tl in 100mL of a sample solution. The detection limit obtained by 3 method was 0.19ng. The proposed method was applied to the determination of Tl in natural water samples. The results showed the concentration of Tl in seawater was 12.1±1.8pgmL–1 for the calibration graph method and 12.6±1.4pgmL–1 for the standard addition method. A snowmelt sample contained 20.7±1.0pgmL–1 of Tl.  相似文献   

6.
The interaction of indophenol blue (IPB) with proteins in aqueous solution has been studied by optical absorption and Rayleigh light scattering (RLS) spectroscopy. At pH 3.8, the weak RLS of IPB is enhanced by proteins. Based on this phenomenon, a novel method for the determination of proteins at nanogram levels using the RLS technique is developed. The method is simple, practical and sensitive. The linear range is 0.25–20.9µgmL–1 for BSA, and 0.25–17.6µgmL–1 for HSA. The detection limits (S/N=3) are 23ngmL–1 for BSA and 22ngmL–1 for HAS. The results for the determination of proteins in human serum samples are very close to those obtained by an established clinical method. There is very little interference from amino acids, metal ions or other coexisting compounds.  相似文献   

7.
A simple and novel electrogenerated chemiluminescence (ECL) method for the determination of sulfite has been developed based on the energy transfer ECL process. It was found that a weak ECL signal of sulfite was electrochemically generated on a platinum electrode in neutral aqueous solution. The signal was strongly enhanced by rhodamine B as an energy receptor and further enhanced by the neutral surfactant Tween 80. In 0.10M phosphate buffer solution (pH=7.5) containing 2.0×10–6gmL–1 rhodamine B and 0.4% (v/v) Tween 80, the ECL response to the concentration of sulfite at a potential of 0.82V was linear over a range of 1.0×10–7gmL–1 to 8.0×10–6gmL–1, and the detection limit was 5×10–8gmL–1. The relative standard deviation (n=11, 1.0×10–6gmL–1) was 3.8%. The proposed method has been successfully applied to the determination of sulfite in pharmaceutical injections and white sugar samples.  相似文献   

8.
Summary. Steady state quenching studies of curcumin, 1,7-bis(4-hydroxy-3-methoxyphenyl)-1,6-heptadiene-3,5-dione, fluorescence by hydrogen peroxide were conducted in acetonitrile solution. A quenching rate constant, kq, of 1.05×1010M–1·s–1 was obtained with a short fluorescence lifetime of 347ps. The reaction rate constant, which is within the diffusion-limited regime, is activation-controlled. The rate constant of deactivation of the thermally excited curcumin was 1.2 orders of magnitude more nonradiative (2.67×109s–1) than radiative (2.16×108s–1). The reaction was exothermic with a G° of –1.97eV and solvent reorganization energy of 1.37eV. These values indicate that the electron transfer reaction is solvent-mediated with electron transfer rate constant, kET, of 2.16×1010s–1.  相似文献   

9.
Osmocene (and decamethylosmocene) is characterized by a lowest-energy ligand field triplet which occurs at max=372nm (374nm) in absorption and 567nm (572nm) in emission. This orange–yellow phosphorescence is rather intense at 77K but is also visible at r.t.  相似文献   

10.
A medium power radiofrequency capacitively coupled plasma (275W, 27.12MHz) with low argon consumption (0.5Lmin–1) was investigated to be used for the determination of aluminium in water samples pneumatically nebulised by atomic emission spectrometry. The plasma torch was operated in two geometric configurations, coaxial and coaxial-annular with single (SRTr.f.CCP) or double ring electrodes (DRTr.f.CCP), respectively. The optimum experimental parameters (observation height, Ar flow rate, distance between ring electrodes, matrix interference of Na+ and Ca2+ and anion nature) for Al 396.152nm emission were established. Under optimum operating conditions of the DRTr.f.CCP torch (6cm distance between annular electrodes), a detection limit of 70ngmL–1 aluminium was found. Both operating parameters and several figures of merit of the investigated plasmas were compared to those of microwave plasmas and inductively coupled plasma used in atomic emission spectrometry. The method was used to control the quality of drinking and industrial water. Samples were mineralised with 2mL of 1+1 HNO3 and 10mL of 1+1 HCl. In the range of 0.15–3.5mgL–1 Al3+ the relative standard deviation varied between 3.7 and 8.6% (n=3). For two certified drinking water samples containing 0.206 and 0.218mgL–1 Al3+ the recovery (n=5) was 97.6±6.8% and 98.6±7.3%, respectively.  相似文献   

11.
A new method for the simultaneous determination of heavy metal ions in Chinese herbal medicine by microwave digestion and reversed-phase high-performance liquid chromatography (RP-HPLC) has been developed. The Chinese herbal medicine samples were digested by microwave digestion. Lead, cadmium, mercury, nickel, copper, zinc, and tin ions in the digested samples were pre-column derivatized with tetra-(4-chlorophenyl)-porphyrin (T4-CPP) to form the colored chelates which were then enriched by solid phase extraction with C18 cartridge and eluted from the cartridge with tetrahydrofuran (THF). The chelates were separated on a Waters Xterra RP18 column by gradient elution with methanol (containing 0.05molL–1 pyrrolidine-acetic acid buffer salt, pH=10.0) and THF (containing 0.05molL–1 pyrrolidine-acetic acid buffer salt, pH=10.0) as mobile phase at a flow rate of 0.5mLmin–1 and detected with a photodiode array detector in the range of 350–600nm. In the original samples the detection limits of lead, cadmium, mercury, nickel, copper, zinc and tin are 4ngL–1, 3ngL–1, 6ngL–1, 5ngL–1, 2ngL–1, 6ngL–1, and 4ngL–1, respectively. This method was applied to the determination of lead, cadmium, mercury, nickel, copper, zinc and tin in Chinese herbal medicine samples with good results.  相似文献   

12.
The fabrication and electrochemical characteristics of a penicillamine (PCA) self-assembled monolayer modified gold electrode were investigated. The self-assembled electrode shows obvious electrocatalytic activity for the oxidation of epinephrine (EP). In phosphate buffer (pH 7.73), a sensitive oxidation peak was observed at 0.190V with the PCA modified Au electrode. The peak current is proportional to the concentration of EP in the range of 2.0×10–56.0×10–4molL–1 and 5.0×10–6 2.0×10–4molL–1 for cyclic voltammetry (CV) and differential pulse voltammetry (DPV) with the detection limits of 1.8×10–7 and 1.3×10–7molL–1, respectively. The possible reaction mechanism is also discussed. The PCA self-assembled monolayer modified gold electrode is highly stable and can be applied to the determination of EP in practical injection samples. Application is simple, rapid and produces accurate results.  相似文献   

13.
A simple commercial graphite pencil electrode (GPE) was utilized for monitoring caffeine using the square-wave anodic stripping voltammetry (SWASV) method. This method was applied to determine the caffeine levels in several tea samples, which yielded a relative error of 1% in the concentrations. Caffeine was deposited at 0.0V (vs. Ag/AgCl), then reduced at +1.40V to strip it on the GPE. Optimal experimental conditions for the analysis were found to be as follows: pH value of 9 for the medium; deposition potential of 0.0V; deposition time of 120s; SW frequency of 25Hz; SW amplitude of 45mV, and step potential of 6mV. Given these optimum conditions, a linear range was observed within the concentration of 0500mgL–1. At caffeine concentrations of 50.0, 250.0, and 500.0mgL–1, the relative standard deviations in measured concentrations (n=12) were 0.19, 0.09, and 0.11%, respectively. The detection limit was found to be 9.2mgL–1, which is comparable with the result obtained using a carbon paste electrode, equivalent to 8.2mgL–1.  相似文献   

14.
A sensitive and fast analytical method using purge-and-trap on-line coupling with gas chromatography was developed for the determination of trace volatile sulfur compounds including dimethyl sulfide (DMS), ethyl-methyl sulfide (EMS), and dimethyl disulfide (DMDS) in beverage and coffee samples. The analytes were purged for 12min from the sample by high purity nitrogen at a flow rate of 35KPa and preconcentrated in the cooled fused-silica capillary trap at –75°C. The NaCl content in the samples was maintained at 10%. The volatile sulfur compounds were separated with an Agilent-6890 gas chromatograph by a suitable temperature program and detected by means of a flame photometric detector (FPD). The detection limits were 80ngL–1 for DMS, 80ngL–1 for EMS, and 100ngL–1 for DMDS, respectively. This method was successfully applied to the determination of volatile sulfur compounds in different beverage and coffee samples.  相似文献   

15.
The thermal stability of the cellulose synthase complex of Acetobacter xylinum has been analyzed in terms of enzyme activity loss as well as detection of its two major components (83kDa and 93kDa polypeptides) in polyacrylamide gels under different electrophoretic sample treatment conditions. The cellulose synthase complex intrinsically is a thermally unstable enzyme and quickly loses its in vitro activity beyond 35°C. The 83 kDa polypeptide has been found to be more labile than the 93 kDa polypeptide. When boiled in lithium dodecyl sulfate (LDS) buffer, the 83 kDa polypeptide is destroyed through peptide hydrolysis while the 93 kDa polypeptide remains uncleaved. The 83 kDa polypeptide is destroyed in LDS buffer at elevated temperatures beyond 55°C. When boiled in the absence of LDS buffer, the 83 kDa polypeptide is completely aggregated, while the 93 kDa polypeptide is only partially aggregated. In the absence of LDS buffer, the complete thermal aggregation of the 83 kDa polypeptide occurs at elevated temperatures beyond 85°C. The aggregation process has been quantitatively analyzed by a newlyintroduced quantitative index, Td (the temperature at which half the quantity of 83kDa polypeptide disappears due to aggregation). The Td determined for the 83kDa polypeptide in the productentrapped fraction is 48°C.  相似文献   

16.
A new method of SS-RTP for the determination of trace silver has been established. This method is based on the fact that Ag+, when activated by ,-bipyridyl (bipy) in a media of HAc–NaAc (pH=4.9), can catalyze the reaction of Rhodamine B (RhoB) oxidized by K2S2O8, thus causing the Solid Substrate Room-Temperature Phosphorescence (SS-RTP) of RhoB to be quenched. The activating efficiency of bipy is 6.7 times higher than that of o-phenanthroline (phen). The reduction of the phosphorescence intensity (Ip) of RhoB is directly proportional to the concentration of Ag+ ions in the range of 1.6016.0agspot–1 (0.40µLspot–1). The regression equation of the working curve can be expressed as Ip=18.78+5.100mAg+ (agspot–1) (r=0.9994, n=6), the detection limit is 0.28agspot–1. This rapid, accurate and sensitive method has been successfully applied to the determination of trace silver in tea and human hair samples, and the results agree well with the Atomic Absorption Spectroscopy (AAS) method. The mechanism of the catalyzing reaction is also discussed.  相似文献   

17.
A new approach, based on non-aqueous capillary electrophoresis separation and indirect photometric detection, was established for the determination of the transition metal ions Pb2+, Zn2+ and Cd2+. Under optimized conditions, the method produced baseline separation of these three metal ions. The linear range and detection limits were 1050µM, 1.9µM for Cd2+; 1050µM, 2.1µM for Zn2+; and 20100µM, 3.8µM for Pb2+, respectively.  相似文献   

18.
A single-wall carbon nanotubes (SWNT) film coated glassy carbon electrode (GCE) was fabricated for the direct determination of 4-nitrophenol (4-NP). The electrochemical behaviors of 4-NP at the SWNT-film coated GCE were examined. In 0.1M phosphate buffer with a pH of 5.0, 4-NP yields a very sensitive and well-defined reduction peak at the SWNT-modified GCE. It is found that the SWNT film exhibits obvious electrocatalytic activity towards the reduction of 4-NP since it not only increases the reduction peak current but also lowers the reduction overpotential. Based on this, an electrochemical method was proposed for the direct determination of 4-NP. The reduction peak current varies linearly with the concentration of 4-NP ranging from 1×10–8 to 5×10–6M, and the detection limit is 2.5×10–9M after 3min of open-circuit accumulation. The relative standard deviation at 2×10–7M 4-NP was about 6% (n=10), suggesting excellent reproducibility. This new method was successfully employed to determine 4-NP in several lake water samples.  相似文献   

19.
The statistical characteristics of the intracavity laser spectrometer are investigated by analysis of cesium in aqueous solutions. The error distribution of measurements is normal. The relative standard deviation of the analysis in the middle of the dynamic range is equal to 9.7%. The intracavity spectral analysis was carried out at low contents of cesium, manganese and terbium in aqueous solutions. The limits of detection are: 5 gl-1 (Cs), 20 gl-1 (Mn) and 1000 gl-1 (Tb). Owing to the high spectral resolution of the spectrometer used the hyperfine structure of the thallium absorption line (535.05 nm) was recorded.  相似文献   

20.
A method of determining iodine in the vacuum ultraviolet region by inductively coupled plasma optical emission spectrometry in enriched Chlorella is established and evaluated. Alga Chlorella samples enriched with iodine were solubilized with tetramethylammonium hydroxide. The iodine content was quantified by inductively coupled plasma optical emission spectrometry using the 182.980nm emission line of iodine to avoid the spectral interference from phosphorus which occurs in Chlorella at the 178.218nm emission line of iodine. The methods accuracy was confirmed by a modified Sandell and Kolthoff spectrophotometric method (As3+, Ce4+ and brucine) after alkaline ashing, and the agreement between the methods was about 96%. The limit of detection in real samples was 3mgkg–1 for enriched Chlorella, and the iodine content in the samples varied between 100 and 1300mgkg–1.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号