首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Azaspiracids are neurotoxins produced by marine algae that have been detected in harvested mussels since 1995. They pose a significant threat to human health through the consumption of contaminated shellfish, and negatively impact the economy of areas where shellfish are harvested and processed. Regulatory agencies are beginning to advocate instrumental assays over traditional mouse bioassay methods. The development and validation of an assay method for AZA 1, the predominant azaspiracid toxin, and the production of a calibration standard and reference material will therefore be vital for quality control in monitoring laboratories worldwide. This report demonstrates a rapid and reproducible liquid chromatography/mass spectrometry (LC/MS) method for separation of all twelve known azaspiracids. Using a triple-quadrupole mass spectrometer, ultra-high sensitivity was obtained at the low-femtogram level injected on-column. At the same time, a linear response of three orders of magnitude was observed. We compared the results with those measured on an ion-trap mass spectrometer. The triple-quadrupole instrument was more sensitive, reliable and reproducible than the ion-trap instrument. The detection limit obtained on the ion-trap mass spectrometer was ten times higher than that obtained on the triple quadrupole. During the study, a new azaspiracid analog (AZA 7c) was discovered.  相似文献   

2.
Collision-induced dissociation (CID) mass spectra were generated for azaspiracids using electrospray ionisation (ESI), and hydrogen/deuterium (H/D) exchange was used to ascertain the number and type of replaceable hydrogens in the three predominant azaspiracid toxins. H/D exchange was conveniently achieved using deuterated solvents for liquid chromatography (LC). Using ion-trap mass spectrometry, multiple-stage CID experiments (MS(n)) on the protonated and fully exchanged ions were performed to decipher characteristic fragmentation pathways. The precursor and product ions from azaspiracids lost up to five water molecules from different regions during MS(n) experiments and it was possible to distinguish between the water losses from different molecular regions. These studies confirmed that the first water-loss ion in the spectra of azaspiracids resulted from dehydration at the vicinal diol at C20-C21. Five MS dissociation pathways were identified that resulted from fragmentation of the carbon skeleton of azaspiracids producing nitrogen-containing ions. Two pathways, involving cleavage of the E-ring and C27-C28, gave ions that were found in all azaspiracids. Three pathways, A-ring, C-ring and C19-C20 cleavages, were useful for distinguishing between azaspiracid analogues. The same product ions from backbone fragmentation were also observed using hybrid quadrupole time-of-flight mass spectrometry (QqTOFMS). The fragmentation of the A-ring was the most facile and was exploited in the development of LC/MS(n) methods for the analysis of azaspiracids.  相似文献   

3.
The biotoxins, azaspiracids (AZAs), from marine phytoplankton accumulate in shellfish and affect human health by causing severe gastrointestinal disturbance, diarrhea, nausea and vomiting. Specific and sensitive methods have been developed and validated for the determination of the most commonly occurring azaspiracid analogs. An LTQ Orbitrap mass spectrometer is a hybrid instrument that combines linear ion trap (LIT) mass spectrometry (MS) with high‐resolution Fourier transform (FT) MS and this was exploited to perform simultaneous ultra‐high‐resolution full‐scan MS analysis and collision‐induced dissociation (CID) tandem mass spectrometry (MS/MS). Using the highest mass resolution setting (100 000 FWHM) in full‐scan mode, the methodology was validated for the determination of six AZAs in mussel (Mytilus galloprovincialis) tissue extracts. Ultra‐high mass resolution, together with a narrow mass tolerance window of ±2 mDa, dramatically improved detection sensitivity. In addition to employing chromatographic resolution to distinguish between the isomeric azaspiracid analogs, AZA1/AZA6 and AZA4/AZA5, higher energy collisionally induced dissociation (HCD) fragmentation on selected precursor ions were performed in parallel with full‐scan FTMS. Using HCD MS/MS, most precursor and product ion masses were determined within 1 ppm of the theoretical m/z values throughout the mass spectral range and this enhanced the reliability of analyte identity. For the analysis of mussels (M. galloprovincialis), the method limit of quantitation (LOQ) was 0.010 µg/g using full‐scan FTMS and this was comparable with the LOQ (0.007 µg/g) using CID MS/MS. The repeatability data were; intra‐day RSD% (1.8–4.4%; n = 6) and inter‐day RSD% (4.7–8.6%; n = 3). Application of these methods to the analysis of mussels (M. edulis) that were naturally contaminated with azaspiracids, using high‐resolution full‐scan Orbitrap MS and low‐resolution CID MS/MS, produced equivalent quantitative data. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

4.
The rapid desorption electrospray ionisation (DESI) of some small molecules and their fragmentation using a triple-quadrupole and a hybrid quadrupole time-of-flight mass spectrometer (Q-ToF) have been investigated. Various scanning modes have been employed using the triple-quadrupole instrument to elucidate fragmentation pathways for the product ions observed in the collision-induced dissociation (CID) spectra. Together with accurate mass tandem mass spectrometry (MS/MS) measurements performed on the hybrid Q-ToF mass spectrometer, unequivocal product ion identification and fragmentation pathways were determined for deprotonated metoclopramide and protonated aspirin, caffeine and nicotine. Ion structures and fragmentation pathway mechanisms have been proposed and compared with previously published data. The necessity for elevated resolution for the differentiation of isobaric ions are discussed.  相似文献   

5.
Characterisation of phospholipids was achieved using collision-induced dissociation (CID) with an ion-trap mass spectrometer. The product ions were compared with those obtained with a triple quadrupole mass spectrometer. In the negative ion mode the product ions were mainly sn-1 and sn-2 lyso-phospholipids with neutral loss of ketene in combination with neutral loss of the polar head group. Less abundant product ions were sn-1 and sn-2 carboxylate anions. CID using a triple quadrupole mass spectrometer, however, gave primarily the sn-1 and sn-2 carboxylate anions together with lyso-phosphatidic acid with neutral loss of water. For the ion trap a charge-remote-type mechanism is proposed for formation of the lyso-phospholipid product ions by loss of alpha-hydrogen on the fatty acid moiety, electron rearrangement and neutral loss of ketene. A second mechanism involves nucleophilic attack of the phosphate oxygen on the sn-1 and sn-2 glycerol backbone to form carboxylate anions with neutral loss of cyclo lyso-phospholipids. CID (MS(3) and MS(4)) of the lyso-phospholipids using the ion-trap gave the same carboxylate anions as those obtained with a triple quadrupole instrument where multiple collisions in the collision cell are expected to occur. The data demonstrate that phospholipid species determination can be performed by using LC/MS(n) with an ion-trap mass spectrometer with detection of the lyso-phospholipid anions. The ion-trap showed no loss in sensitivity in full scan MS(n) compared to multiple reaction monitoring data acquisition. In combination with on-line liquid chromatography this feature makes the ion-trap useful in the scanning modes for rapid screening of low concentrations of phospholipid species in biological samples as recently described (Uran S, Larsen A, Jacobsen PB, Skotland T. J. Chromatogr. B 2001; 758: 265).  相似文献   

6.
Structure analyses of underivatized neutral lacto oligosaccharides are systematically performed by ultraviolet matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (UV-MALDI TOF MS) and UV-MALDI ion-trap time-of-flight mass spectrometry (ion-trap/TOF MS) acquired in negative-ion mode. Interestingly, their fragmentation significantly differ each other. In postsource decay (PSD) in UV-MALDI TOF MS, cross-ring cleavage at the reducing terminal predominates. On the other hand, glycosyl bond cleavage (C-type fragmentation) takes place preferentially in collision induced dissociation (CID) in UV-MALDI ion-trap/TOF MS. The cross-ring cleavage in PSD similar to that in in-source decay occurs via a prompt reaction path characteristic of the UV-MALDI process itself. The product ion spectra of UV-MALDI ion-trap/TOF MS are similar to the electrospray ionization (ESI) ion-trap or quadrupole/TOF CID product ion spectra. During ion-trap/TOF MS experiments, the deprotonated molecular ions survive for several tens of milliseconds after CID event because the high internal energy chlorinated precursor ions are cooled by collisional cooling in the ion trap. The results obtained suggest that the PSD from the chlorinated precursor ion in UV-MALDI TOF MS might proceed as a two-step reaction; in the first, a high internal energy deprotonated molecular ion is generated as a reaction intermediate during the flight in the drift tube, and in the second, the rapid decomposition from the deprotonated molecular ion takes place.  相似文献   

7.
Fragmentation studies using both an ion-trap mass analyzer and a hybrid quadrupole time-of-flight (Q-TOF) mass spectrometer were performed in order to establish the fragmentation pathways of organic molecules. A general strategy combining MSn data (n = 1-4) in an ion-trap analyzer with tandem mass spectrometry and in-source collision-induced dissociation tandem mass spectrometry (CID MS/MS) in a Q-TOF instrument was applied. The MSn data were used to propose a tentative fragmentation pathway following genealogical relationships. When several assignments were possible, MS/MS and in-source CID MS/MS (Q-TOF) allowed the elemental compositions of the fragments to be confirmed. Quaternary ammonium herbicides (quats) were used as test compounds and their fragmentation pathways were established. The elemental composition of the fragments was confirmed using the TOF analyzer with relative errors <0.0023 Da. Some fragments previously reported in the literature were reassigned taking advantage of the high mass resolution and accuracy of the Q-TOF instrument, which made it possible to solve losses where nitrogen was involved.  相似文献   

8.
Azaspiracid poisoning (AZP) is a new human toxic syndrome that is caused by the consumption of shellfish that have been feeding on harmful marine microalgae. A liquid chromatography–mass spectrometry (LC–MS) method has been developed for the determination of the three most prevalent toxins, azaspiracid (AZA1), 8-methylazaspiracid (AZA2) and 22-demethylazaspiracid (AZA3) as well as the isomeric hydroxylated analogues, AZA4 and AZA5. Separation of five azaspiracids was achieved on a C18 column (Luna-2, 150×2 mm, 5 μm) with isocratic elution using acetonitrile–water containing trifluoroacetic acid and ammonium acetate as eluent modifiers. Using an electrospray ionisation (ESI) source with an ion-trap mass spectrometer, the spectra showed the protonated molecules, [M+H]+, with most major product ions due to the sequential loss of two water molecules. A characteristic fragmentation pathway that was observed in each azaspiracid was due to the cleavage of the A-ring at C9–C10 for each toxin. It was possible to select unique ion combinations to distinguish between the isomeric azaspiracids, AZA4 and AZA5. Highly sensitive LC–MS3 analytical methods were compared and the detection limits were 5–40 pg on-column. Linear calibrations were obtained for AZA1 in shellfish in the range 0.05–1.00 μg/ml (r2=0.9974) and good reproducibility was observed with a relative standard deviation (%RSD) of 1.8 for 0.9 μg AZA1/ml (n=5). The %RSD values for the minor toxins, AZA4 and AZA5, using LC–MS3 (A-ring fragmentation) were 12.3 and 8.1 (0.02 μg/ml; n=7), respectively. The selectivity of toxin determination was enhanced using LC–MS–MS with high energy WideBand activation.  相似文献   

9.
Fully-protected C-terminal free peptides can be conveniently analyzed by high-resolution electrospray tandem mass spectrometry (ESI-MS/MS) in a quadrupole quadrupole time-of-flight tandem hybrid mass spectrometer, operated in the negative (-) ionizaionization mode. The unusual choice of negative ions in mass spectrometry applications to peptide analysis was needed to obtain exhaustive sequence and structural data. The low-energy collision-induced dissociation (CID) experiments provided, in fact, tandem mass spectra displaying highly diagnostic fragments with a good signal-to-noise ratio. The method is applied to segments of porcine calcitonin (Cal), Cal (1016, 1), Cal (1724, 2) and Cal (2528, 3) whose [M H]- deprotonated molecular ions provided low-energy CID mass spectra which allow the evaluation either of the primary structure of the peptide and of the location of the side-chain protective groups. ESI (+) MS can be conveniently used, in the high resolution mode, to achieve precise information on the elemental composition of the examined peptides.  相似文献   

10.
Azaspiracid (AZA1), a recently discovered marine toxin, is responsible for the new human toxic syndrome, azaspiracid poisoning (AZP), which is caused by the consumption of contaminated shellfish. A new, sensitive liquid chromatography/mass spectrometry (LC/MS) method has been developed for the determination of AZA1 and its analogues, 8-methylazaspiracid (AZA2) and 22-demethylazaspiracid (AZA3). Separation of these toxins was achieved using reversed-phase LC and coupled, via an electrospray ionisation (ESI) source, to an ion-trap mass spectrometer. Spectra showed the protonated molecules, [M + H]+, and their major product ions, due to the sequential loss of two water molecules, [M + H - H2O]+, [M + H - 2H2O]+, in addition to fragment ions that are characteristic of these cyclic polyethers. A highly specific and sensitive LC/MS(3) analytical method was developed and, using shellfish extracts containing AZA1, the detection limit (S/N = 3) was 4 pg on-column, corresponding to 0.8 ng/mL. Using the protocol presented here, this is equivalent to 0.37 ng/g shellfish tissue and good linear calibrations were obtained for AZA1 in shellfish extracts (average r2 = 0.9988). Good reproducibility was achieved with % RSD values (N = 5) ranging from 1.5% (0.75 microg/mL) to 4.2% (0.05 microg/mL). An efficient procedure for the extraction of toxins from shellfish aided the development of a rapid protocol for the determination of the three predominant azaspiracids.  相似文献   

11.
Electrospray ionization quadrupole time-of-flight (ESI-QqToF) mass spectra of naltrindole hydrochloride 1, naltriben mesylate 2, and naltrexone hydrochloride 3, a common series of morphine opiate receptor antagonists, were recorded using different declustering potentials. Low-energy collision-induced dissociation (CID) MS/MS experiments established the fragmentation routes of these compounds. In addition, re-confirmation of the various established fragmentation routes was effected by conducting a series of ESI-CID-QqTof-MS/MS experiments using non-conventional quasi MS(n) (up to MS8) product ion scans, which were initiated by CID in the atmospheric pressure/vacuum interface using a higher declustering potential. Precursor ion scan analyses were also performed with a conventional quadrupole-hexapole-quadrupole tandem mass spectrometer and allowed the confirmation of the genesis of some diagnostic ions.  相似文献   

12.
Azaspiracids have been identified as the cause of a new toxic syndrome called azaspiracid poisoning (AZP) that has led to incidents of human intoxications throughout Europe following the consumption of mussels. Although five AZP toxins have been structurally elucidated to-date, azaspiracid (AZA1), 8-methylazaspiracid (AZA2) and 22-demethylazaspiracid (AZA3) are the predominant toxins. Separation of the three main AZP toxins was achieved using reversed-phase liquid chromatography (LC) and coupled to an electrospray ionisation source of an ion-trap mass spectrometer. Five reversed-phase (C18) and three diol solid-phase extraction (SPE) cartridges were compared for their efficacy in the cleanup of shellfish matrix. The comparison was based on the optimum recoveries of AZA1, AZA2 and AZA3 from extracts of mussel tissues. LC-electrospray MS3 analysis was used to quantify the AZP toxins in wash and eluate fractions in the SPE studies. Good recovery and reproducibility data were obtained for one diol SPE cartridge and two C18 SPE cartridge types.  相似文献   

13.
Details of the optimization of the collision-induced dissociation (CID) process, using a collision cell on a matrix-assisted laser desorption/ionization (MALDI) time-of-flight (TOF) mass spectrometer, are described using poly(ethylene glycol) 1000 (PEG 1000) as a model analyte. The effects of collision gas identity (helium, air, and argon), as well as collision gas pressure, on the resulting MS/MS data were investigated. With PEG 1000, helium was found to give the best results with respect to signal-to-noise (S/N) ratio. The optimum pressure for each gas was found to be in the range where the precursor ion signal was attenuated to approximately 30-50% for helium and 40-60% for argon. The effect of cation choice (Li, Na, and K) on the CID of PEG was also studied. CID spectra were produced for each, but PEG cationized with lithium was found to produce the spectra with the highest S/N ratio. The MALDI-TOF CID spectra that were generated for PEG were compared with the high-energy and low-energy MS/MS spectra obtained from a sector mass spectrometer and from a triple quadrupole mass spectrometer, respectively. The results observed for PEG confirm that CID on a MALDI-TOF mass spectrometer is a high-energy MS/MS technique.  相似文献   

14.
15.
A novel group of toxins, the spirolides, has been investigated by several mass spectrometric (MS) methods to enable structure elucidation and metabolite identification. These macrocyclic compounds, produced by the dinoflagellate Alexandrium ostenfeldii, are a new class of marine phycotoxin with characteristic spiro-linked tricyclic ether and imine moieties. A crude phytoplankton extract has been shown to contain known spirolides and several unknown compounds, present at low yet significant levels. This study has focused on mass spectrometric characterization of the main component of this extract, 13-desmethyl spirolide C. Collision-induced dissociation (CID) spectra were collected on triple-quadrupole and quadrupole linear ion-trap instruments. High-resolution Fourier-transform ion cyclotron resonance MS data revealed the accurate masses of the protonated molecule and the product ions formed by infrared multiphoton dissociation. A fragmentation scheme for this toxin has been proposed to explain the formation of the collision-induced fragments. Charge-remote fragmentations dominate the CID spectra, because there is only one predominantly basic site in this molecule, and prove to be structurally informative. Extensive MS characterization of 13-desmethyl spirolide C will undoubtedly be useful in the characterization of known and unknown spirolides and other related compounds.  相似文献   

16.
A matrix-assisted laser desorption/ionization (MALDI) source has been coupled to a tandem quadrupole/time-of-flight (QqTOF) mass spectrometer by means of a collisional damping interface. Mass resolving power of about 10,000 (FWHM) and accuracy in the range of 10 ppm are observed in both single-MS mode and MS/MS mode. Sub-femtomole sensitivity is obtained in single-MS mode, and a few femtomoles in MS/MS mode. Both peptide mass mapping and collision-induced dissociation (CID) analysis of tryptic peptides can be performed from the same MALDI target. Rapid spectral acquisition (a few seconds per spectrum) can be achieved in both modes, so high throughput protein identification is possible. Some information about fragmentation patterns was obtained from a study of the CID spectra of singly charged peptides from a tryptic digest of E. coli citrate synthase. Reasonably successful automatic sequence prediction (>90%) is possible from the CID spectra of singly charged peptides using the SCIEX Predict Sequence routine. Ion production at pressures near 1 Torr (rather than in vacuum) is found to give reduced metastable fragmentation, particularly for higher mass molecular ions. Copyright 2000 John Wiley & Sons, Ltd.  相似文献   

17.
Searchable libraries of MS/MS spectra, obtained using liquid chromatography/tandem mass spectrometry (LC/MS/MS) with data-dependent scan mode switching on both quadrupole ion trap and triple-quadrupole mass spectrometers in conjunction with electrospray ionization, are presented. The effects on library search scores of changing the parameters for producing collision-induced dissociation (CID) on both instrument types are systematically evaluated. These observations serve as a basis for determining a universal set of conditions for building MS/MS libraries. A group of 19 closely related steroids was used. The ability to obtain library-searchable spectra at low concentrations is demonstrated for the analysis of a sample of progesterone spiked with hydroxyprogesterone impurities at 0.1 and 0.01%.  相似文献   

18.
Fixed-energy sequential tandem mass spectrometry (MS(n)) capabilities offered by quadrupole ion trap instruments have been explored in a systematic study of six isomers of Gal-Fucalpha-OBenzyl disaccharides. Under collision-induced dissociation (CID), sodiated molecular species generated in the positive-ion electrospray ionization mode yield simple and predictable mass spectra. Information on interglycosidic linkages and configurations can be deduced from the relative intensities of the selected diagnostic fragments arising from the glycosidic bond cleavages and corroborated by the fragments arising from cross-ring cleavages. As the CID patterns are not dependent on the number of prior tandem mass spectrometric steps, structures can be unambiguously assigned by matching the spectra with a library. The rules governing the fragmentation behavior of this class of oligosaccharides were tested for a representative isomeric disaccharide, Glcbeta1,3Fucalpha-OAllyl. The findings establish a basis for using MS(n) with a quadrupole ion trap instrument to elucidate structures of hexose-fucose subunits from more complicated oligosaccharides. Energy-resolved mass spectra were also acquired by CID tandem triple-quadrupole mass spectrometry. The breakdown behavior of the molecular ions revealed patterns which could differentiate stereoisomers of Gal-Fuc disaccharides over a range of collision energy from 20 to 50 eV.  相似文献   

19.
LC-MS-MS is becoming a very important tool for the on-line identification of natural products in crude plant extracts. For an efficient use of this technique in the dereplication of natural products, a careful study of the parameters used to generate informative MS-MS spectra is needed. In this paper, the collision-induced dissociation (CID) MS-MS spectra of ubiquitous C-glycosidic flavonoids have been systematically studied using hybrid quadrupole time-of-flight and ion-trap (IT) mass analysers under various CID energy conditions. Efficient differentiation of flavonoid C-glycoside isomers was possible, based on the comparison of CID-MS-MS spectra of particular C-glycoside unit fragments. Striking differences between 6-C and 8-C flavonoid glycosides were especially observed in the product ion spectra of their 0.2X+ fragments ([M+H-120]+). Some guidelines for the on-line characterisation of C-glycosidic flavonoids by LC-MS-MS or LC-multiple-stage MS are given.  相似文献   

20.
Comparative MS/MS studies of singly and doubly charged electrospray ionization (ESI) and matrix-assisted laser desorption/ionization (MALDI) precursor peptide ions are described. The spectra from these experiments have been evaluated with particular emphasis on the data quality for subsequent data processing and protein/amino acid sequence identification. It is shown that, once peptide ions are formed by ESI or MALDI, their charge state, as well as the collision energy, is the main parameter determining the quality of collision-induced dissociation (CID) MS/MS fragmentation spectra of a given peptide. CID-MS/MS spectra of singly charged peptides obtained on a hybrid quadrupole orthogonal time-of-flight mass spectrometer resemble very closely spectra obtained by matrix-assisted laser desorption/ionization post-source decay time-of-flight mass spectrometry (MALDI-PSD-TOFMS). On the other hand, comparison of CID-MS/MS spectra of either singly or doubly charged ion species shows no dependence on whether ions have been formed by ESI or MALDI. This observation confirms that, at the time of precursor ion selection, further mass analysis is effectively decoupled from the desorption/ionization event. Since MALDI ions are predominantly formed as singly charged species and ESI ions as doubly charged, the associated difference in the spectral quality of MS/MS spectra as described here imposes direct consequences on data processing, database searching using ion fragmentation data, and de novo sequencing when ionization techniques are changed.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号