首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Jin Y  Manabe T 《Electrophoresis》2005,26(6):1019-1028
A simple and fast method of protein extraction from Coomassie Brilliant Blue (CBB)-stained polyacrylamide gels suited for molecular mass measurement of proteins by matrix-assisted laser desorption/ionization-time of flight-mass spectrometry (MALDI-TOF-MS) is reported. Proteins in CBB-stained gel pieces were extracted by a 10-min soaking in 0.1 M NaOH at 25 degrees C. The recovery of this one-step extraction method was 34-73% for proteins <67 kDa. CBB adduction to proteins during mass spectrometric analysis was avoided by a destaining step before the alkaline extraction. The molecular mass values of the extracted proteins coincided with those of purified proteins within +/-0.01-0.10% deviation for all the proteins <36 kDa. Because of the high extraction recovery, mass measurement was possible for the proteins extracted from CBB-stained gels with loaded protein quantities as little as 34 ng for cytochrome c, alpha-lactalbumin, myoglobin, beta-lactoglobulin, trypsinogen, and carbonic anhydrase (12.4-29.0 kDa), 340 ng for glyceraldehyde-3-phosphate dehydrogenase (35.6 kDa) and albumin (66.3 kDa). This method provides a highly efficient approach to utilize CBB-stained one- or two-dimensional gels for whole protein analysis using MALDI-TOF-MS.  相似文献   

2.
Different search programs were compared to judge their particular efficiency in protein identification. We established a human blood platelet protein map and identified tyrosine-phosphorylated proteins. The cytosolic fraction of human blood platelets was separated by two-dimensional polyacrylamide gel electrophoresis (2-D PAGE) and phosphorylated proteins were detected by Western blotting using anti-phosphotyrosine antibodies. Visualized protein spots were excised, digested with trypsin and analyzed by matrix assisted laser desorption/ionization-time of flight-mass spectrometry (MALDI-TOF-MS). The obtained mass fingerprint data sets have been analyzed using ProFound, MS-Fit and Mascot. For those protein spots with no significant search results MALDI post source decay (PSD) spectra have been acquired on the same sample. For automatic interpretation of these fragment ion spectra, the SEQUEST and Mascot algorithm were applied. Another approach for the identification of phosphorylated proteins is immunoprecipitation using an anti-phosphotyrosine antibody. A method for immunoprecipitation of tyrosine-phosphorylated peptides was optimized.  相似文献   

3.
A prototype matrix-assisted laser desorption/ionization quadrupole time-of-flight (MALDI-TOF) tandem mass spectrometer was used to sequence a series of phosphotyrosine-, phosphothreonine- and phosphoserine-containing peptides. The high mass resolution and mass accuracy of the instrument allowed the localization of one, three or four phosphorylated amino acid residues in phosphopeptides up to 3.1 kDa. Tandem mass spectra of two different phosphotyrosine peptides permitted amino acid sequence determination and localization of one and three phosphorylation sites, respectively. The phosphotyrosine immonium ion at m/z 216.04 was observed in these MALDI low-energy CID tandem mass spectra. Elimination of phosphate groups was evident from the triphosphorylated peptide but not from the monophosphorylated species. The main fragmentation pathway for the synthetic phosphothreonine-containing peptide and for phosphoserine-containing peptides derived from beta-casein and ovalbumin was the beta-elimination of phosphoric acid with concomitant conversion of phosphoserine to dehydroalanine and phosphothreonine to 2-aminodehydrobutyric acid. Peptide fragment ions of the b- and y-type allowed, in all cases, the localization of phosphorylation sites. Ion signals corresponding to (b-17), (b-18) and (y-17) fragment ions were also observed. The abundant neutral loss of phosphoric acid (-98 Da) is useful for femtomole level detection of phosphoserine-peptides in crude peptide mixtures generated by gel in situ digestion of phosphoproteins.  相似文献   

4.
A fast protocol for prototyping hydrophobic disposable poly(alkyl methacrylate-co-methyl methacrylate) copolymer sample support arrays for matrix-assisted laser desorption/ionization-mass spectrometry (MALDI-MS) of proteins by atmospheric molding is introduced. The sample support arrays were replicated by molding prepolymer alkyl methacrylate solutions into sandwich molds containing a micromachined silicon master, an aluminum spacer, and glass cover plates, followed by UV-initiated in situ polymerization under atmospheric pressure. The fabrication procedure enables a simultaneous fabrication/modification of single-use polymer arrays by a targeted selection of functional groups of the copolymerized monomers during molding. The one-step modification during the fabrication is demonstrated for enhanced protein adsorption to the modified materials by introduction of hydrophobic butyl-, dodecyl-, and octadecyl groups to the polymer backbone without a need for additional surface coating or derivatization. The MALDI-MS performance of the new polymer chips was tested for spectral measurements of bovine pancreas insulin, horse heart myoglobin, and bovine serum albumin. The protein adsorption to the new hydrophobic copolymer chips was studied for bovine pancreas trypsinogen; the sample desalting parameters, such as time and volume, were optimized for myoglobin as model proteins. A significant signal increase was achieved after efficient desalting of an insect Delta11-desaturase membrane protein fragment from a complex elution buffer (100 mM phosphate, 10 mM tris(hydroxyethyl)aminomethane, 0.5 M NaCl, and 10 mM ethylenediamine tetraacetic acid) on the poly(butyl methacrylate-co-methyl methacrylate) copolymer chip (monomer ratio 8:2 v/v) by simply washing the target zones. The new chips offer reduced sample manipulation and device fabrication times as well as simple operation.  相似文献   

5.
The overall history and recent advances in surface enhanced laser desorption/ionization-time of flight-mass spectrometry (SELDI-TOF-MS) technology is reviewed herein. Fundamentals of SELDI-TOF analysis are presented while drawing comparisons with other laser-based mass spectrometry techniques. The application of SELDI-TOF-MS to functional genomics and biomarker discovery is discussed and exemplified by elucidating a biomarker candidate for prostatic carcinoma. Finally, a short discussion regarding future SELDI requirements and developments is supplied.  相似文献   

6.
A novel combination of methods, two-dimensional liquid-phase electrophoresis (2D-LPE) and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS), have been used for the analysis of intact brain-specific proteins in cerebrospinal fluid (CSF). 2D-LPE is especially useful for isolating proteins present in low concentrations in complex biological samples. The proteins are separated in the first dimension by liquid-phase isoelectric focusing (IEF) in the Rotofor cell and in the second dimension by sodium dodecyl sulphate polyacrylamide gel electrophoresis (SDS-PAGE) in the Preparative cell. The removal of SDS by chloroform/methanol/water, followed by sample preparation with the addition of n-octylglucoside, easily interfaced 2D-LPE with MALDI-TOFMS for analysis of intact proteins. Further characterization by proteolytic digestion is also demonstrated. The knowledge of both the molecular weights of the protein and of the proteolytic fragments obtained by peptide mapping increases specificity for protein identification by searching in protein sequence databases. Two brain-specific proteins in human CSF, cystatin C and transthyretin, were isolated in sufficient quantity for determination of the mass of the whole proteins and their tryptic digest by MALDI-TOFMS. This approach simplified the interface between electrophoresis and MALDI-TOFMS.  相似文献   

7.
Xu S  Pan C  Hu L  Zhang Y  Guo Z  Li X  Zou H 《Electrophoresis》2004,25(21-22):3669-3676
Desorption/ionization on silicon mass spectrometry (DIOS-MS) is a matrix-free technique that allows for the direct desorption/ionization of low-molecular-weight compounds with little or no fragmentation of analytes. This technique has a relatively high tolerance for contaminants commonly found in biological samples. DIOS-MS has been applied to determine the activity of immobilized enzymes on the porous silicon surface. Enzyme activities were also monitored with the addition of a competitive inhibitor in the substrate solution. It is demonstrated that this method can be applied to the screening of enzyme inhibitors. Furthermore, a method for peptide mapping analysis by in situ digestion of proteins on the porous silicon surface modified by trypsin, combined with matrix-assisted laser desorption/ionization-time of flight-MS has been developed.  相似文献   

8.
The objective of this work was to develop a sample preparation procedure for determination of the carbohydrate profiles in commercial juice samples by three principally different analytical methods: capillary electrophoresis (CE) with indirect detection, high-performance liquid chromatography (HPLC), and matrix-assisted laser desorption/ionization-time of flight-mass spectrometry (MALDI-TOF-MS). The preparation and purification of juice samples prior to analysis is described. The method using Carrez reagents was found to be an efficient preparation tool for all three methods. The addition of Carrez reagents to the samples for mass analysis improved the quality of the mass spectra of oligosaccharides. The amounts of glucose, fructose, and sucrose as major carbohydrates in fruit juices measured by CE using a simple instrument are in good agreement with the HPLC values and the data declared by the producers of the juices. The results from both methods are critically evaluated and their impact for studies of authenticity is discussed. The decrease of sucrose amount during the storage of samples was explained by acid hydrolysis of this disaccharide.  相似文献   

9.
Metal labelling of peptides and proteins using high-affinity metal-chelating compounds has found widespread applications in the medical and bioanalytical fields. In the present study we investigated the analysis of peptides derivatized either with cysteine- or amino group-directed metal-bound DOTA (1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid) chelators in matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS). The metal complexes of DOTA were shown to be stable under MALDI-MS conditions. The introduction of the metal label led in a number of cases to significantly increased signal-to-noise (S/N) values and thus improved sensitivity of the labelled peptides compared to their unlabelled counterparts, especially for multiply labelled peptides. The presence of the labels did alter the tandem mass spectrometric (MS/MS) behaviour, namely the formation of sequence specific a-, b- and y-ion series, in dependence of the position of the label within the peptide sequence. For cysteine-derivatized peptides several label-specific reporter ions and characteristic immonium ions could be identified. Amino-directed labelling led only to the formation of characteristic immonium ions in ε-amino groups of lysine, whereas N-terminal labelling in some cases led to the formation of a(1)- and b(1)-ions. The results clearly show that MALDI-MS is suitable for the analysis of metal-labelled peptides, which was also confirmed in liquid chromatography (LC)/MALDI-based identification of proteins in a model protein mixture labelled with Cys-reactive DOTA. Here, in comparison to a run with alkylated cysteines, more than 50% more cysteine-containing peptides were identified.  相似文献   

10.
Apolipoprotein E (apoE) was isolated from human cerebrospinal fluid (CSF) from control individuals and patients with Alzheimer's disease (AD). The purification was performed with preparative two-dimensional electrophoresis (2-DE), involving liquid-phase isoelectric focusing (IEF) in the Rotofor cell in combination with sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE) and electroelution in the Mini Whole Gel Eluter. ApoE was characterized by matrix-assisted laser desorption/ionization-time of flight-mass spectrometry (MALDI-TOF-MS) analysis of tryptic digests. The known change of Cys to Arg in position 112 of the apoE4 isoform was identified. This was detected in CSF from AD patients, reflecting the increased frequency of the apoE4 allele in this population. This peptide was not detected in CSF samples from healty control individuals. The use of this rapid electrophoretic separation in proteomic studies of CSF proteins provides single proteins, such as apoE, of high purity in yields sufficient for characterization by MALDI-TOF-MS. Characterization of proteins and their modifications (amino acid substitutions, glycosylation or phosphorylation) in CSF will be a useful tool in the investigation of the pathophysiology of brain disorders such as AD.  相似文献   

11.
Direct tandem mass spectrometric (MS/MS) analysis of small, singly charged protein ions by tandem time-of-flight mass spectrometry (TOFMS) is demonstrated for proteins up to a molecular mass of 12 kDa. The MALDI-generated singly charged precursor ions predominantly yield product ions resulting from metastable fragmentation at aspartyl and prolyl residues. Additional series of C-terminal sequence ions provide in some cases sufficient information for protein identification. The amount of sample required to obtain good quality spectra is in the high femtomolar to low picomolar range. Within this range, MALDI-MS/MS using TOF/TOF trade mark ion optics now provides the opportunity for direct protein identification and partial characterization without prior enzymatic hydrolysis.  相似文献   

12.
Digests from ten gel bands containing low abundance proteins were analyzed by both matrix-assisted laser desorption/ionization ion trap (MALDI-IT) and matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry (MS) methods. MALDI-TOF techniques were able to identify only one protein from all 10 gel bands, while MALDI-IT identified eight proteins from the same 10 bands. The ability to perform MS/MS experiments with a MALDI-IT instrument leads to protein identifications based on both peptide molecular mass and sequence information, and is much less prone to errors and uncertainties introduced by peptide fingerprinting methodologies in which protein identification is based on peptide molecular masses alone.  相似文献   

13.
Cerebrospinal fluid (CSF) is in close proximity to the brain and changes in the protein composition of CSF may be indicative of altered brain protein expression in neurodegenerative disorders. Analysis of brain-specific proteins in CSF is complicated by the fact that most CSF proteins are derived from the plasma and tend to obscure less abundant proteins. By adopting a prefractionation step prior to two-dimensional gel electrophoresis (2-DE), less abundant proteins are enriched and can be detected in complex proteomes such as CSF. We have developed a method in which liquid-phase isoelectric focusing (IEF) is used to prefractionate individual CSF samples; selected IEF fractions are then analysed on SYPRO-Ruby-stained 2-D gels, with final protein identification by matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry (MALDI-TOFMS). To optimise the focusing of the protein spots on the 2-D gel, the ampholyte concentration in liquid-phase IEF was minimised and the focusing time in the first dimension was increased. When comparing 2-D gels from individual prefractionated and unfractionated CSF samples it is evident that individual protein spots are larger and contain more protein after prefractionation of CSF. Generally, more protein spots were also detected in the 2-D gels from prefractionated CSF compared with direct 2-DE separations of CSF. Several proteins, including cystatin C, IgM-kappa, hemopexin, acetyl-coenzyme A carboxylase-alpha, and alpha-1-acid glycoprotein, were identified in prefractionated CSF but not in unfractionated CSF. Low abundant forms of posttranslationally modified proteins, e.g. alpha-1-acid glycoprotein and alpha-2-HS glycoprotein, can be enriched, thus better resolved and detected on the 2-D gel. Liquid-phase IEF, as a prefractionation step prior to 2-DE, reduce sample complexity, facilitate detection of less abundant protein components, increases the protein loads and the protein amount in each gel spot for MALDI-MS analysis.  相似文献   

14.
Derivatization of tryptic peptides using an Ettan CAF matrix-assisted laser desorption/ionization (MALDI) sequencing kit in combination with MALDI-post source decay (PSD) is a fast, accurate and convenient way to obtain de novo or confirmative peptide sequencing data. CAF (chemically assisted fragmentation) is based on solid-phase derivatization using a new class of water stable sulfonation agents, which strongly improves PSD analysis and simplifies the interpretation of acquired spectra. The derivatization is performed on solid supports, ZipTip(microC18, limiting the maximum peptide amount to 5 microg. By performing the derivatization in solution enabled the labeling of tryptic peptides derived from 100 microg of protein. To increase the number of peptides that could be sequenced, derivatized peptides were purified using multidimensional liquid chromatography (MDLC) prior to MALDI sequencing. Following the first dimension strong cation exchange (SCX) chromatography step, modified peptides were separated using reversed-phase chromatography (RPC). During the SCX clean up step, positively charged peptides are retained on the column while properly CAF-derivatized peptides (uncharged) are not. A moderately complex tryptic digest, prepared from six different proteins of equimolar amounts, was CAF-derivatized and purified by MDLC. Fractions from the second dimension nano RPC step were automatically sampled and on-line dispensed to MALDI sample plates and analyzed using MALDI mass spectrometry fragmentation techniques. All proteins in the derivatized protein mixture digest were readily identified using MALDI-PSD or MALDI tandem mass spectrometry (MS/MS). More than 40 peptides were unambiguously sequenced, representing a seven-fold increase in the number of sequenced peptides in comparison to when the CAF-derivatized protein mix digest was analyzed directly (no MDLC-separation) using MALDI-PSD. In conclusion, MDLC purification of CAF-derivatized peptides significantly increases the success rate for de novo and confirmative sequencing using various MALDI fragmentation techniques. This new approach is not only applicable to single protein digests but also to more complex digests and could, thus, be an alternative to electrospray ionization MS/MS for peptide sequencing.  相似文献   

15.
Staphylococcal enterotoxin A (SEA) is an exotoxin excreted mainly by Staphylococcus aureus and nowadays is the most prevalent compound in staphylococcal food poisoning worldwide. SEA is highly heat-resistant, and usual cooking times and temperatures are unlikely to completely inactivate it. A procedure for extraction of this toxin based on protein precipitation with a mixture of dichloromethane and acidified water was used before SDS-PAGE separation of soluble proteins. Finally, bands of interest were excised from the gel and in-gel enzymatic digestion was done. SEA from pasteurized milk was detected with matrix-assisted laser-desorption/ionization-time of flight (MALDI-TOF) mass spectrometry. Nineteen peptides (range 800-2400 Da) were identified as products of trypsin cleavage of the SEA standard with a score of 204 and 73% coverage of the protein sequence, whereas thirteen peptides were revealed for SEA extracted from milk with a score of 148 and 58% sequence coverage obtained. This procedure has been applied successfully for identification of SEA in milk.  相似文献   

16.
Jin Y  Manabe T 《Electrophoresis》2005,26(14):2823-2834
A method to analyze human plasma proteins without fractionation, directly applying a plasma-matrix mixture on the target plate of a matrix-assisted laser desorption/ionization-time of flight-mass spectrometer (MALDI-TOF-MS), has been described. Peaks of ionized plasma proteins could not be detected applying a mixture of an undiluted plasma sample and a matrix solution, but they appeared when the plasma was diluted before mixing with the matrix. Tenfold diluted plasma provided well-resolved protein peaks in the m/z range from 4000 to 30,000. The addition of a simple post-crystallization washing procedure performed on the target plate further improved the quality of mass spectra. We numbered 58 peaks in the range of 4-160 kDa and 32 out of which were assigned to the plasma protein species which have been reported. Especially high sensitivity and resolution were obtained in the region < 30 kDa, where multiple isoforms of apolipoprotein A-I, apolipoprotein A-II, apolipoprotein C-I, apolipoprotein C-II, apolipoprotein C-III, and transthyretin could be assigned. Various post-translational modifications are involved in the isoforms, e.g., proteolytic cleavage, glycosylation and chemical modifications. This method will become complementary with the present electrophoretic techniques, especially for the analysis of low-molecular-mass proteins.  相似文献   

17.
NESP (novel erythropoiesis-stimulating protein) is a recently approved hyperglycosylated analogue of human erythropoietin (EPO) with a long-lasting effect. In this work, the capillary electrophoresis (CE) methodology proposed by the European Pharmacopoeia for the separation of EPO glycoforms has been modified for the separation of NESP glycoforms. Optimization of pH of the separation electrolyte has been fundamental in order to achieve baseline resolution of seven peaks corresponding to NESP glycoforms. Intact NESP has also been characterized by matrix-assisted laser desorption/ionization-time of flight-mass spectrometry (MALDI-TOF-MS). An accurate approximation to an average molecular mass of the NESP molecule has been obtained, taking into account the strong influence of laser intensity upon the MALDI-TOF mass spectra found.  相似文献   

18.
Vitellogenin (VTG) is a protein produced by the liver of oviparous animals in response to circulating estrogens. In the plasma of males and immature females, VTG is undetectable. VTG has been used as a biomarker for exposure to endocrine disruptors in many species. In the present study, characterization of intact Atlantic salmon VTG was effected using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI ToF MS). Tryptic digest peptides were analyzed by MALDI ToF MS to obtain a peptide mass fingerprint. De novo sequencing of the tryptic peptides used low-energy collisionally-induced dissociation (CID) in an electrospray ionization quadrupole-ToF orthogonal hybrid mass spectrometer (ESI Q-ToF MS/MS). The interpretation of the product-ion spectra obtained from the ESI Q-ToF MS/MS was done by Lutefisk, a computer-based software algorithm. The molecular mass of the intact protein was found to be 187335 Da. A total of 14 tryptic peptides were sequenced and compared with the complete rainbow trout VTG and the partial Atlantic salmon VTG sequences found in the Swiss-Prot database. De novo sequencing by CID MS/MS of 11 Atlantic salmon tryptic digest peptides with selected precursor ions at m/z 788.24, 700.20, 794.75, 834.31, 889.28, 819.79, 865.27, 843.81, 572.20, 573.66 and 561.68 showed high homology with the known sequence of rainbow trout VTG. The last two precursor peptide ions, found at m/z 573.66 and m/z 561.68, also specifically matched the known portion of the Atlantic salmon VTG sequence. Finally, three tryptic precursor peptide ions found at m/z 795.18, 893.28 and 791.05, provided product-ion spectra, which were exclusive to the unsequenced portion of the Atlantic salmon VTG.  相似文献   

19.
The identification of isoforms is one of the great challenges in proteomics due to the large number of identical amino acids preventing their separations by two-dimensional electrophoresis. Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) has become a rapid and sensitive tool in proteomics, notably with the new instrumental improvements. In this study, we used several acquisition modes of MALDI-TOFMS to identify isoforms of porcine glutathiones S-transferase. The use of multiple proteases coupled to the different acquisition modes of MALDI-TOFMS (linear, reflectron, post-source decay (PSD) and in-source decay, positive and negative modes) allowed the identification of two sequences. Moreover, a third sequence is pointed out from a PSD study of a tryptic ion revealing the modification of the amino acid tyrosine 146 to phenylalanine.  相似文献   

20.
The nematode Caenorhabditis elegans (C. elegans) is the first animal whose whole 97 Mb genome sequence, encoding ca. 19000 open reading frames (ORF's), has been essentially determined. We tried to establish a 2-DE map of the nematode proteome by means of two-dimensional polyacrylamide gel electrophoresis (2-D PAGE). A soluble protein fraction of mixed stages of the worm, wild-type strain N2, was applied to 2-D PAGE. After Coomassie Brilliant Blue (CBB) staining, 1200 spots were detected and 140 major spots were excised from the gel and subjected to in-gel digestion with Achromobacter protease I (lysyl endopeptidase). Resulting peptides were analyzed by matrix assisted laser desorption/ionization-time of flight-mass spectrometry (MALDI-TOF-MS) followed by peptide mass fingerprinting for protein identification. With this approach we have obtained a two-dimensional electrophoresis (2-DE) protein map in which 69 spots were localized as landmarks for comparison of expression profiles to elucidate the basis of various biological events.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号