1.
The present study investigated the comparisons of the heat transfer and pressure drop of the microchannel and minichannel heat exchangers, both numerically and experimentally. The results obtained from this study indicated that the heat transfer rate obtained from microchannel heat exchanger was higher than those obtained from the minichannel heat exchangers; however, the pressure drops obtained from the microchannel heat exchanger were also higher than those obtained from the minichannel heat exchangers. As a result, the microchannel heat exchanger should be selected for the systems where high heat transfer rates are needed. In addition, at the same average velocity of water in the channels used in this study, the effectiveness obtained from the microchannel heat exchanger was 1.2–1.53 times of that obtained from the minichannel heat exchanger. Furthermore, the results obtained from the experiments were in good agreement with those obtained from the design theory and the numerical analyses.  相似文献   

2.
3.
Two-phase flow in horizontal pipe was analyzed with simplified models for annular and stratified flow. The velocity profiles for the liquid and gas phase were described with the Prandtl mixing length. From this analysis, the frictional pressure drop was calculated with the modified Baker map for flow pattern transition. The intermediate region, i.e. wavy flow, was interpolated between annular and stratified flow. Comparison of this analysis with existing experimental data of refrigerants showed good agreement.  相似文献   

4.
The heat transfer, pressure drop and flow patterns during flow boiling of R407C in a horizontal microfin tube have been investigated. The microfin tube is made of copper with a total fin number of 55 and a helix angle of 15°. The fin height is 0.24 mm and the inner tube diameter at fin root is 8.95 mm. The test tube is 1 m long. It is heated electrically. The experiments have been performed at saturation temperatures between −30°C and +10°C. The mass flux was varied between 25 and 300 kg/m2/s, the heat flux from 20,000 W/m2 down to 1,000 W/m2. The vapour quality was kept constant at 0.1, 0.3, 0.5, 0.7 at the inlet and 0.8, 1.0 at the outlet, respectively. The measured heat transfer coefficient is compared with the correlations of Cavallini et al., Shah as well as Zhang et al. Cavallini’s correlation contains seven experimental constants. After fitting these constants to our measured values, the correlation achieves good agreement. The measured pressure drop is compared to the correlations of Pierre, Kuo and Wang as well as Müller-Steinhagen and Heck. The best agreement is achieved with the correlation of Kuo and Wang. Almost all values are calculated within an accuracy of ±30%. The flow regimes were observed. It is shown, that changes in the flow regime affect the heat transfer coefficient significantly.  相似文献   

5.
The problem of unsteady oscillatory flow and heat transfer of two viscous immiscible fluids through a horizontal channel with isothermal permeable walls has been considered. The partial differential equations governing the flow and heat transfer are solved analytically using two-term harmonic and non-harmonic functions in both fluid regions of the channel. Effects of physical parameters such as viscosity ratio, conductivity ratio, Prandtl number and frequency parameter on the velocity and temperature fields are shown graphically. It is observed that the velocity and temperature decrease as the viscosity ratio increases, while they increase with increases in frequency parameter. The effect of increasing the thermal conductivity ratio also suppresses the temperature in both fluid regions. The effect of periodic frequency on the flow is depicted in tabular form. It is predicted that both the velocity and temperature profiles decrease as the periodic frequency increases.  相似文献   

6.
Experiments with refrigerant two-phase flow in a horizontal pipe have been performed and data on flow pattern, void fraction and pressure drop have been obtained. Refrigerants used were R12 and R22, and the range of saturation pressure was from 5.7 to 19.6 bar.In this paper, the experimental equipment and procedure are described in detail, and the data are both tabulated and presented graphically.  相似文献   

7.
This paper presents the experimental results of condensation heat transfer coefficients of hydrocarbon (HC) refrigerants R-290 and R-600a, hydrochlorofluorocarbon (HCFC) refrigerant R-22, and hydrofluorocarbon (HFC) refrigerant R-134a in a horizontal double-pipe heat exchanger having pipe inner diameters of 10.07, 7.73, 6.54, and 5.80 mm. The condensation process experiments were conducted at mass flux of 35.5–210.4 kg/ms and condensation temperature of 40°C. The main results were summarized as follows: The average condensation heat transfer coefficients of R-290 and R-600a were higher than those of R-22 and R-134a. The pressure drops of the four refrigerants were in the order of R-600a > R-290 > R-134a > R-22. The pressure drops of R-600a, R-290, R-134a, and R-22 were approximately 6–15, 9.8–12.5, 4.3–6.7, and 2.1–4.6% higher, respectively, in the 10.7 mm diameter tubes compared to the 5.80 mm diameter tubes. Comparing the condensation heat transfer coefficients of our experimental results with those of other correlations, our experimental data in all the test tubes coincided best with that of Haraguchi et al.  相似文献   

8.
Counter-current flow pattern transition and pressure drop are modeled. Emphasis is placed on the understanding of the transition mechanisms from a mechanistic point of view.

Unlike the case of co-current flow, in counter-current flow, the situations of “no solution” as well as “multiple solutions” for the flow pattern and pressure drop exist. These possibilities are discussed and criteria for the actual flow pattern that will take place are suggested.

Some of the results are supported by data (from the literature), others are somewhat tentative suggesting future experimental verification is needed.  相似文献   


9.
A separated flow model has been developed that is applicable to vertical annular two-phase flow in the purely convective heat transfer regime. Conservation of mass, momentum, and energy are used to solve for the liquid film thickness, pressure drop, and heat transfer coefficient. Closure relationships are specified for the interfacial friction factor, liquid film eddy-viscosity, turbulent Prandtl number, and entrainment rate. Although separated flow models have been reported previously, their use has been limited, because they were tested over a limited range of flow and thermal conditions. The unique feature of this model is that it has been tested and calibrated against a vast array of two-phase pressure drop and heat transfer data, which include upflow, downflow, and microgravity flow conditions. The agreements between the measured and predicted pressure drops and heat transfer coefficients are, on average, better or comparable to the most reliable empirical correlations. This separated flow model is demonstrated to be a reliable and practical predictive tool for computing two-phase pressure drop and heat transfer rates. All of the datasets have been obtained from the open literature.  相似文献   

10.
The two-phase flow in the corrugated gap created by two adjacent plates of a plate heat exchanger was investigated experimentally. One setup consisting of a transparent corrugated gap was used to visualize the two-phase flow pattern and study the local phenomena of phase distribution, pressure drop and void fraction. Saturated two-phase R365mfc and an air-water mixture were used as working fluids.In a second experimental setup, the heat transfer coefficients and the pressure drop inside an industrial plate heat exchanger during the condensation process of R134a are determined. Both experimental setups use the same type of plates, so the experimental results can be connected and a flow pattern model for the condensation in plate heat exchangers can be derived. In this work the results of the flow pattern visualization, the two-phase pressure drop in the corrugated gap and the void fraction analysis by measurement of the electrical capacity are presented. A new pressure drop correlation is derived, which takes into account different flow patterns, that appear during condensation. The mean deviation of the presented pressure drop model compared to the experimental data and data from other experimental works is 18.9%. 81.7% of the calculated pressure drop lies within ±30% compared to the experimental data.  相似文献   

11.
Spirally fluted tubes are used extensively in the design of tubular heat exchangers. In previous investigations, results for tubes with flute depths e/Dvi < 0.2 were reported, with most correlations applicable for Re ≥ 5000. This paper presents the results of an experimental investigation of the heat transfer and pressure drop characteristics of spirally fluted tubes with the following tube and flow parameter ranges: flute depth e/Dvi = 0.1−0.4, flute pitch p/Dvi = 0.4−7.3, helix angle θ/90° = 0.3−0.65, Re = 500−80,000, and Pr = 2−7. The heat transfer coefficients inside the fluted tube were obtained from measured values of the overall heat transfer coefficient using a nonlinear regression scheme. The friction factor data obtained consisted of 507 data points. The proposed correlation for the friction factor predicts 96% of the database within ±20%. The heat transfer correlation for the range 500 ≤ Re ≤ 5000 predicts 76% of the database (178 data points) within ±20%, and the correlation for the higher Re range predicts 97% of the 342 data points within ±20%. Comparison of heat transfer and friction data show that these tubes are most effective in the laminar and transition flow regimes. The present results show that the increase of flute depth in the range considered does not improve heat transfer.  相似文献   

12.
13.
Pressure drop behaviour of ice slurry based on ethanol–water mixture in circular horizontal tubes has been experimentally investigated. The secondary fluid was prepared by mixing ethyl alcohol and water to obtain initial alcohol concentration of 10.3% (initial freezing temperature ?4.4 °C). The pressure drop tests were conducted to cover laminar and slightly turbulent flow with ice mass fraction varying from 0% to 30% depending on test conditions. Results from flow tests reveal much higher pressure drop for higher ice concentrations and higher velocities in comparison to the single phase flow. However for ice concentrations of 15% and higher, certain velocity exists at which ice slurry pressure drop is same or even lower than for single phase flow. It seems that higher ice concentration delay flow pattern transition moment (from laminar to turbulent) toward higher velocities. In addition experimental results for pressure drop were compared to the analytical results, based on Poiseulle and Buckingham–Reiner models for laminar flow, Blasius, Darby and Melson, Dodge and Metzner, Steffe and Tomita for turbulent region and general correlation of Kitanovski which is valid for both flow regimes. For laminar flow and low buoyancy numbers Buckingham–Reiner method gives good agreement with experimental results while for turbulent flow best fit is provided with Dodge–Metzner and Tomita methods.Furthermore, for transport purposes it has been shown that ice mass fraction of 20% offers best ratio of ice slurry transport capability and required pumping power.  相似文献   

14.
Analytic solutions are obtained by solving the conservation equations describing fully developed parabolic laminar flow with heat transfer to predict the axial velocity profile, the temperature distribution and the secondary flow behaviour in a square duct. The biharmonic equation arising in this problem has been solved by using the Navier method for simply supported rectangular plates. The analytic solutions substantially agree with the available experimental results.  相似文献   

15.
The flow boiling heat transfer characteristics of R134a in the multiport minichannel heat exchangers are presented. The heat exchanger was designed as the counter flow tube-in-tube heat exchanger with refrigerant flowing in the inner tube and hot water in the gap between the outer and inner tubes. Two inner tubes were made from extruded multiport aluminium with the internal hydraulic diameter of 1.1 mm for 14 numbers of channels and 1.2 mm for eight numbers of channels. The outer surface areas of two inner test sections are 5979 mm2 and 6171 m2, while the inner surface areas are 13,545 mm2 and 8856 mm2 for 14 and eight numbers of channels, respectively. The outer tube of heat exchanger was made from circular acrylic tube with an internal hydraulic diameter of 25.4 mm. The experiments were performed at the heat fluxes between 15 and 65 kW/m2, mass flux of refrigerant between 300 and 800 kg/m2 s and saturation pressure ranging from 4 to 6 bar. For instance the boiling curve, average heat transfer coefficients are discussed. The comparison results of two test sections with different the number of channels are investigated. The results are also compared with nine existing correlations. The new correlation for predicting the heat transfer coefficient was also proposed.  相似文献   

16.
An experimental investigation of complete condensation flow is undertaken for a range of mass flow rates between 3.4 and 13.8 kg/m2 s. The associated flow regimes are visualized using an ombroscopic technique. Two major flows are observed (with or without release of bubbles). A critical value of the mass flow rate is obtained at the transition between these two regimes. The visualization also enables a local parameter to be determined: the void fraction. The influence of the presence of a bubbly zone is highlighted by the heat transfer and pressure drops. Finally, the dependence of the critical value of the mass flow rate on the temperature of the secondary flow is obtained.  相似文献   

17.
Condensation heat transfer of R134a in a vertical plate heat exchanger was investigated experimentally. The local heat transfer coefficients are determined by means of the measured local wall temperatures. A differential energy balance model is developed for data evaluation. It is found that the correlation proposed by Shah using Ψ and Z factors is suitable for condensation in plate heat exchangers and is adopted to fit the measured data.  相似文献   

18.
The present work deals with computational modeling of the fluid flow and heat transfer taking place in the process of impact of a cold liquid drop (Td = 20-25 °C) onto a dry heated substrate characterized by different thermophysical properties. The computational model, based on the volume-of-fluid method for the free-surface capturing, is validated by simulating the configurations accounting for the conjugate heat transfer. The simulations were performed in a range of impact Reynolds numbers (Re = 2000-4500), Weber numbers (We = 27-110) and substrate temperatures (Ts = 100-120 °C). The considered temperature range of the drop-surface, i.e. liquid-solid system does not account for the phase change, that is boiling and evaporation. The model performances are assessed by contrasting the results to the reference database originating from the experimental and complementary numerical investigations by Pasandideh-Fard et al. [Pasandideh-Fard, M., Aziz, S., Chandra, S., Mostaghimi, J., 2001. Cooling effectiveness of a water drop impinging on a hot surface. International Journal of Heat and Fluid Flow, 22, 201-210] and Healy et al. [Healy, W., Hartley, J., Abdel-Khalik, S., 2001. On the validity of the adiabatic spreading assumption in droplet impact cooling. International Journal of Heat and Mass Transfer, 44, 3869-3881]. In addition, the thermal field obtained is analyzed along with the corresponding asymptotic analytical solution proposed by Roisman [Roisman, I.V., 2010. Fast forced liquid film spreading on a substrate: flow, heat transfer and phase transition. Journal of Fluid Mechanics, 656, 189-204]. Contrary to some previous numerical studies, the present computational model accounts for the air flow surrounding the liquid drop. This model feature enables a small air bubble to be resolved in the region of the impact point. The reported results agree reasonably well with experimental and theoretical findings with respect to the drop spreading pattern and associated heat flux and temperature distribution.  相似文献   

19.
This investigation is aimed at studying the heat transfer characteristics and pressure drop for turbulent airflow in a sudden expansion pipe equipped with propeller swirl generator. The investigation is performed for the Reynolds number ranging from 10,000 to 41,000 under a uniform heat flux condition. The experiments are conducted for three locations for the propeller fan upstream the sudden expansion and three locations downstream the sudden expansion (N = 5 blades and blade angle of 45°). The influences of using a freely rotating propeller on heat transfer enhancement and pressure drop are reported. The experimental results indicate that inserting the propeller downstream of the tube provides considerable improvement of the heat transfer rate higher than inserting the propeller upstream the tube. The increase in pressure drop resulting from using the propeller upstream is found to be higher than the downstream swirler. The maximum performance enhancement for the downstream swirler is about 326% while it is about 213% for upstream one. Correlations for relative mean Nusselt number and enhancement performance are presented for different fan locations and different Reynolds numbers.  相似文献   

20.
This paper presents results of the experimental study conducted on heated horizontal rectangular fin array under natural convection. The temperature mapping and the prediction of the flow patterns over the fin array with variable fin spacing is carried out. Dimensionless fin spacing to height (S/H) ratio is varied from 0.05 to 0.3 and length to height ratio (L/H) = 5 is kept constant. The heater input to the fin array assembly is varied from 25 to 100 W. The single chimney flow pattern is observed from 8 to 12 mm fin spacing. The end flow is choked below 6 mm fin spacing. The single chimney flow pattern changes to sliding or end flow choking at 6 mm fin spacing. The average heat transfer coefficient (ha) is very small (2.52–5.78 W/m2 K) at 100 W for S = 5–12 mm. The ha is very small (1.12–1.8 W/m2 K) at 100 W for 2–4 mm fin spacing due to choked fin array end condition. The end flow is not sufficient to reach up to central portion of fin array and in the middle portion there is an unsteady down and up flow pattern resulting in sliding chimney. The central bottom portion of fin array channel does not contribute much in heat dissipation for S = 2–4 mm. The ha has significantly improved at higher spacing as compared to lower spacing region. The single chimney flow pattern is preferred from heat transfer point of view. The optimum spacing is confirmed in the range of 8–10 mm. The average heat transfer results are compared with previous literature and showed similar trend and satisfactory agreement. An empirical equation has been proposed to correlate the average Nusselt number as a function of Grashof number and fin spacing to height ratio. The average error for this equation is ?0.32 %.  相似文献   