首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
We present a new system for the sensitive analysis of cephalosporins by CE using both on-line SPE and large-volume sample stacking (LVSS). Sample volumes of 250 muL were loaded onto the SPE microcolumn which was then desorbed with 426 nL of ACN. The SPE elution plug was injected into the CE system via an in-line valve interface filling approximately 60% of the volume of the separation capillary. Subsequently, LVSS was performed by applying a voltage of -5 kV, which resulted in the simultaneous removal of the elution solvent and the preconcentration of the analytes in a narrow zone. This way the amount of analyte loaded into the capillary could be considerably increased without serious loss of CE separation efficiency. LODs for cefoperazone and ceftiofur were in the ng/L range which represents an improvement of a factor of 8450 and 11 450 when compared with direct CE injection. The cephalosporin test compounds presented a good linear response (corrected peak area) between 0.5 and 10 mug/L with correlation coefficients higher than 0.995. The final method is compared with previously reported LVSS-CE and SPE-CE systems for the analysis of cephalosporins.  相似文献   

2.
提出了固相萃取富集-高效液相色谱-串联质谱法测定饮用水源水体中8种抗生素残留量的方法。样品按规定方法进行预处理并调节其酸度至pH 2.5或pH 3.2。将此溶液经过Oasis HLB SPE小柱进行富集并净化。用XBridge C18色谱柱为分离柱,以不同体积比的(A)10mmol·L-1甲酸溶液和(B)10mmol·L-1甲酸-甲醇溶液组成的混合液作流动相进行梯度淋洗。串联质谱分析中采用电喷雾正、负离子源及多反应监测模式。8种抗生素的质量浓度均在1.00~400μg·L-1范围内与其峰面积呈线性关系,方法的检出限(3S/N)在0.4~0.7ng·L-1之间。加标回收率在81.9%~110%之间,测定值的相对标准偏差(n=7)在0.7%~4.5%之间。  相似文献   

3.
In this work, several commercial sorbents (Zorbax C18, Bond Elut C18, Isolute ENV+, Oasis HLB, Oasis MAX, SDB-RPS, and MPC-SD) were compared for the solid-phase extraction of the series of quinolones regulated by the European Community in chicken tissues in order to establish a method for the determination of this series of quinolones by capillary electrophoresis and diode array detection. Sorbents were chosen in order to achieve maximum recoveries and optimal clean-up efficiency. Better results were obtained using SDB-RPS and Oasis MAX which would provide suitable limits of detection, below of the maximum residue limits (MRLs) regulated.  相似文献   

4.
Zhang LH  Zhang CJ  Chen X  Feng YQ  Wu XZ 《Electrophoresis》2006,27(16):3224-3232
A novel CE method combined with SPE in a single capillary was developed for analysis of chlorophenols in water. A frit of 0.5 mm was first made by a sol-gel method, followed by packing a SPE sorbent in the inlet end of the capillary. Two phenol derivatives, 2,4-dichlorophenol and 2,4,5-trichlorophenol, were used as the model compounds. By loading sample solutions into the capillary, the two chlorophenols were extracted into the sorbent. They were desorbed by injecting only about 4 nL of methanol. Finally, the analytes were separated by conventional CE. The technique provided a concentration enhancement factor of over 4000-fold for both chlorophenols. The detection limits (S/N = 3) of 2,4-dichlorophenol and 2,4,5-trichlorophenol were determined to be 0.1 ng/mL and 0.07 ng/mL, respectively. For replicate analyses of 5 ng/mL of 2,4-dichlorophenol, within-day and between-day RSDs of migration time, peak height and peak area were in the range of 1.8-2.0%, 4.0-4.4% and 4.1-4.6%, respectively. The method shows wide linear range, acceptable reproducibility and excellent sensitivity, and it was applied to the analyses of spiked river water samples. The capillary packed with the SPE sorbents can be used for more than 400 runs without performance deterioration.  相似文献   

5.
《Analytical letters》2012,45(13):1991-2000
A graphene-based solid phase extraction (SPE) technique was developed for the extraction of parabens (methylparaben, ethylparaben, propylparaben, and butylparaben) in cosmetic samples, followed by determination by capillary electrophoresis (CE). The SPE extraction parameters such as eluent reagent and eluent volume, washing solution, sample pH, and flow-rate of sample loading, were investigated for satisfied recoveries. The running buffer, consisting of 25 mM borate solution (pH 10.0), was used for the separation of four parabens with the CE method within 10 min. The limits of detection were 0.14 mg/L, 0.13 mg/L, 0.15 mg/L, and 0.10 mg/L for methylparaben, ethylparaben, propylparaben, and butylparaben, respectively, and the mean recoveries obtained were between 62.6% and 100.4%. The developed method was used for the determination of parabens in real cosmetic products.  相似文献   

6.
A capillary electrophoresis (CE) microchip is utilized for the sensitive separation and detection of three trinitroaromatic explosives: 1,3,5-trinitrotoluene (TNT), 1,3,5-trinitrobenzene (TNB) and 2,4,6-trinitrophenyl-N-methylnitramine (tetryl), in the presence of 10 other explosives and explosive derivatives in nonaqueous electrolyte (acetonitrile/methanol 87.5/12.5 (v/v), 2.5 mM NaOH, 1 mM sodium dodecyl sulfate (SDS)). The chemical reaction of bases, e.g. hydroxide or methoxide ions, with trinitroaromatic compounds forms red colored derivatives that can be easily detected using a green light emitting diode (LED) on the microchip. Two surfactants bearing opposite charge, cetyltrimethylammonium bromide (CTAB) and SDS are compared with respect to their effect on separation times, detection limits and resolving powers for separating these explosives. All microchip separations were achieved in <20 s. In the absence of solid phase extraction (SPE), the detection limits obtained for the trinitroaromatic explosives were as follows: TNB, 60 μg/l; TNT, 160 μg/l and tetryl, 200 μg/l. By coupling the microchip separation with ex situ SPE, the detection limits for detecting these three explosives in seawater were lowered by 240 to more than 1000 times: TNB, 0.25 μg/l; TNT, 0.34 μg/l and tetryl, 0.19 μg/l.  相似文献   

7.
This paper deals with the ability of different types of carbon nanotubes to adsorb salicylic acid in river water samples. The use of these nanoparticles as a sorbent in a SPE procedure prior to CE analysis is essential for improving the enrichment factor and the recovery values. Several experimental variables were optimized in order to maximize the extraction efficiency. The proposed analytical method is simple, fast, and entails low solvent consumption. Furthermore, salicylic acid could be extracted from river water providing good recovery values in the range from 76.2 to 102.0% (RSD<8.2%). The combination of the specific chemical properties of analyte and the unique physicochemical features of carbon nanotubes sheds new light on the use of these nanoparticles as excellent sorbent materials of pharmaceutical compounds in environmental matrices.  相似文献   

8.
This paper describes capillary electrophoresis (CE) methodology for simultaneous determination of oxolinic acid (OXO) and flumequine (FLU) in spiked chicken tissue using norfloxacin (NOR) as internal standard (IS), with diode array detection. The analytes were extracted using dichlorometane and NaOH and pre-concentrated by solid phase extraction (SPE).The recoveries obtained were 94 and 84% for oxolinic acid and flumequine , respectively. The detection and quantification limits achieved were 15 and 48 μg kg−1 for oxolinic acid, respectively, and 10 and 30 μg kg−1 for flumequine. The sensitivity of the method proposed allows the determination of these drugs at a residue level far below their maximum residue limit (MRL) established by the European Union (EU).  相似文献   

9.
Flavonoids are an important bioactive group in the commonly used herbal medicine Flos Lonicerae. A new method of capillary zone electrophoresis (CZE) coupled with solid-phase extraction (SPE) was developed for simultaneous assay of flavonoid aglycones and glycosides in Flos Lonicerae. Optimum CZE separation was achieved with a background electrolyte (BGE) solution consisting of 80 mM boric acid and 20 mM phosphate acid, adjusted to pH 8.1, with 15% acetonitrile (v/v) added, and applying a separation voltage of 28 kV. The SPE method was used for pretreating the complex matrix of botanical materials and good reproducibility was obtained when avicularin was used as internal standard. Linearity of the method was excellent with correlation coefficients (r2) in the range of 0.9995-0.9999 and detection limits were lower than 0.6 microg/mL for the four flavonoids. The obtained recoveries varied between 93 to 104% while the relative standard deviations (RSDs) were below 4.4% (n=3). The developed CZE method was successfully used for the separation of eight flavonoids and the quantification of the four flavonoids in five species of Flos Lonicerae.  相似文献   

10.
研究了流动注射在线固相萃取与毛细管区带电泳联用系统(FI-SPE-CZE)应用于测定血浆中痕量盐酸伪麻黄碱的方法。通过脱线和在线试样净化、优化CZE分离条件等措施消除了血浆中共存组份的干扰;通过增加固相萃取的进样量、加大场放大电动进样量和柱上堆积的力度等,提高了联用系统的灵敏度。血浆试样沉淀蛋白后可连续进入FI-SPE-CZE系统进行自动的浓缩、分离与分析,检测限为12ng/mL,分析速度达10次/h.应用本方法成功地测定了志愿者口服正常剂量盐酸伪麻黄碱后的血药浓度,并试用于药物动力学的研究。  相似文献   

11.
A novel capillary electrophoresis method for simultaneous determination of Cu and Pb has been developed in this paper.Cu(Ⅱ) and Pb(Ⅱ) ions were reacted with ABEDTA to form complex to achieve an ideal sensitivity of heavy metal complexes.The digestion solution of Rhizoma coptidis drug sample was purified by neutral Al2O3 column chromatography and the chromatographic behavior of metal-L complexes was investigated.The calibration curve was linear in the range of 5-60μg/mL for Cu2+ and 5-25μg/mL for Pb2+ with the correlation coefficients 0.9970 and 0.9972 for each(n = 5).The average recoveries were 86.2%for Pb and 90.1%for Cu,while the relative standard deviations were 5.1%and 3.6%respectively.The method was successfully applied to determine Cu and Pb in R.coptidis drug samples.  相似文献   

12.
Abstract

The applicability of a recently developed capillary zone electrophoretic (CZE) method for the determination of low molecular weight (LMW) organic acids in water was tested on five types of environmental samples (rainwater, water extract from peat, and soil water from two polluted sites). A full baseline resolved separation of fourteen commonly found LMW carboxylic acids in natural waters (malonic, oxalic, fumaric, maleic, formic, succinic, tartaric, glutaric, adipic, acetic, propionic, butyric, valeric and citric acids), was achieved within eight minutes. The limits of detection (2 X noise) were in the ranges 90–200 μg/l and 0.5 – 5 μg/l for hydrodynamic and electrokinetic injection, respectively. Two different CZE systems, a Waters Quanta 4000 and a Hewlett Packard HP 3DCE system, were used and their performance compared.  相似文献   

13.
We describe a method for the simultaneous determination of the five fibrinopeptide forms derived from the thrombin-promoted activation of human fibrinogen by capillary zone electrophoresis (CZE). The fibrinopeptide mixture was first desalted by a solid-phase extraction (SPE) step. The analysis was performed in reversed polarity in a highly cross-linked polyethylene glycol (PEG)-coated capillary with UV-light absorption detection at 200 nm. Several parameters including buffer concentration and pH, presence of an organic modifier, temperature, and applied voltage, have been tested. The best separations were obtained within 20 min, utilizing a 20 mM sodium phosphate buffer without organic modifier, in the narrow 6.1-6.2 pH range, at 25 degrees C, with an applied voltage of 20 kV. Quantitative analysis is made possible by the use of sheep fibrinopeptide A as an internal standard to correct for both extraction and injection errors.  相似文献   

14.
An online preconcentration technique by dynamic pH junction was studied to improve the detection limit for anionic arsenic compounds by CE. The main target compound is roxarsone, or 3-nitro-4-hydroxyphenylarsonic acid, which is being used as an animal feed additive. The other inorganic and organoarsenic compounds studied are the possible biotransformation products of roxarsone. The arsenic species were separated by a dynamic pH junction in a fused-silica capillary using 15 mM phosphate buffer (pH 10.6) as the BGE and 15 mM acetic acid as the sample matrix. CE with UV detection was monitored at a wavelength of 192 nm. The influence of buffer pH and concentration on dynamic pH junction were investigated. The arsenic species focusing resulted in LOD improvement by a factor of 100-800. The combined use of C18 and anion exchange SPE and dynamic pH junction to CE analysis of chicken litter and soils helps to increase the detection sensitivity. Recoveries of spiked samples ranged between 70 and 72%.  相似文献   

15.
In the present work we address the development of a simple and effective method for the determination of triazine herbicide residues in horticultural products by CE in nonaqueous media (NACE). Potato samples were selected as a representative matrix of such foods with a nonfatty content. Isolation of the analytes from the sample matrix was accomplished by extraction with organic solvents, assisted by ultrasound; a clean‐up step of the organic extracts was carried out with SPE, using an Oasis MCX® sorbent to retain the analytes directly from the organic medium. The detection limits achieved in spiked potatoes (1.7–4.0 μg/kg) were lower than the default value of maximum residue level (MRL) established by current EU legislation for pesticide residues in foodstuffs. The results obtained were compared with HPLC in order to evaluate the performance of the NACE procedure.  相似文献   

16.
本文对高效毛细管电泳中样品在线预富集方法作了评述,包括瞬间等速电泳,反流速电泳,场放大进样,场放大排除基体和固相萃取等技术,引用文献81篇。  相似文献   

17.
应用固相萃取-液相色谱-串联质谱法测定养猪废水中10种抗生素的含量。水样由盐酸调节pH至2.5~4.0,流经Oasis HLB固相萃取柱富集后再用甲醇洗脱。以Aglient eclipse XDB C18色谱柱为分离柱,以不同体积比的0.1%(体积分数)甲酸溶液和乙腈混合液为流动相进行梯度洗脱,采用电喷雾正离子源多反应监测模式检测。10种抗生素在一定的质量浓度范围内与其峰面积呈线性关系,方法的检出限(3S/N)在0.03~3.5μg·L-1之间。加标回收率在53.2%~104%之间,测定值的相对标准偏差(n=6)在0.5%~6.3%之间。  相似文献   

18.
Springer VH  Lista AG 《Talanta》2010,83(1):126-129
A new method to determine metsulfuron methyl (MSM) and chlorsulfuron (CS) in different water samples was developed. It consists in a solid phase extraction (SPE) procedure using multiwalled carbon nanotubes (MWCNTs) as sorbent material in combination with capillary zone electrophoretic determination. To carry out the pre-concentration step, a simple flow injection system was developed and optimized. Thus, 250 μL of aqueous solution containing methanol 50% (v/v) and acetonitrile 2% (v/v) as eluent, 10 mL of sample and a flow rate of 1.15 mL min−1 were selected. The CE variables also were optimized. A rapid determination and good resolution of two herbicides were obtained within 9 min using a simple electrophoretic buffer (50 mmol L−1 sodium tetraborate with 3% of methanol, pH = 9.0). Under the optimum conditions, the calibration curves were linear between 0.5 and 6 μg L−1 for MSM and CS with R2 = 0.995 and 0.997, respectively. The repeatability of the proposed method, expressed as relative standard deviation (RSD), varied between 4.1% and 5.4% (n = 10) and the detection limits for MSM and CS were 0.40 and 0.36 μg L−1, respectively. Good results were achieved when the proposed method was applied to spiked real water samples. The recoveries percentages of the two analytes were over the range 86-108%.  相似文献   

19.
This paper proposes a novel strategy to enhance selectivity and sensitivity in CE, using supported liquid membrane (SLM) and off-line SPE simultaneously. The determination of ochratoxin A (OA) in wine has been used to demonstrate the potential of this methodology. In the SLM step, the donor phase (either a 20 mL volume of a standard solution at pH 1 or a wine sample at pH 8) was placed in a vial, where a micromembrane extraction unit accommodating the acceptor phase (1 mL water, pH 11) in its lumen was immersed. The SLM was constructed by impregnating a porous Fluoropore Teflon (PTFE) membrane with a water-immiscible organic solvent (octanol). In the off-line SPE step, the nonpolar sorbent (C-18, 4 mg) selectively retained the target ochratoxin, enabling small volumes of acceptor phase (1 mL) to be introduced. The captured analytes were eluted in a small volume of methanol (0.1 mL). This procedure resulted in sample cleanup and concentration enhancement. The method was evaluated for accuracy and precision, and its RSD found to be 5%. The LODs for OA in the standard solutions and wine samples were 0.5 and 30 microg/L, respectively. The results obtained demonstrate that SLM combined with off-line is a good alternative to the use of immunoaffinity columns prior to CE analysis.  相似文献   

20.
Capillary electrophoresis (CE) has been investigated for the analysis of some neurotransmitters, dopamine (DA), 3-methoxytyramine (3-MT) and serotonin (5-hydroxytryptamine, 5-HT) at nanomolar concentrations in urine. Field-amplified sample injection (FASI) has been used to improve the sensitivity through the online pre-concentration samples. The cationic analytes were stacked at the capillary inlet between a zone of low conductivity - sample and pre-injection plug - and a zone of high conductivity - running buffer. Several FASI parameters have been optimized (ionic strength of the running buffer, concentration of the sample protonation agent, composition of the sample solvent and nature of the pre-injection plug). Best results were obtained using H3PO4–LiOH (pH 4, ionic strength of 80 mmol L−1) as running buffer, 100 μmol L−1 of H3PO4 in methanol–water 90/10 (v/v) as sample solvent and 100 μmol L−1 of H3PO4 in water for the pre-injection plug.In these conditions, the linearity was verified in the 50–300 nmol L−1 concentration range for DA, 3-MT and 5-HT with a determination coefficient (r2) higher than 0.99. The limits of quantification (10 nmol L−1 for DA and 3-MT, 5.9 nmol L−1 for 5-HT) were 500 times lower than those obtained with hydrodynamic injection. However, if this method is applied to the analysis of neurotransmitters in urine, the presence of salts in the matrix greatly reduces the sensitivity of the FASI/CE–UV method.Therefore, a solid phase extraction (SPE) on a dedicated imprinted polymer (MIP) was developed to extract specific neurotransmitters, catecholamines, metanephrines and indolamines, from urine. Matrix salts were thus discarded after sample extraction on AFFINIMIP™ Catecholamine & Metanephrine (100 mg) cartridge.Therefore, lower limits of quantification were determined in artificial urine (46 nmol L−1 for DA, 11 nmol L−1 for 3-MT and 6 nmol L−1 for 5-HT).The application of this protocol MIP-SPE/FASI–CE–UV analysis of neurotransmitters in human urine gave rise to electropherograms with a very good base line and signal to noise ratios above 15.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号