首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到19条相似文献,搜索用时 78 毫秒
1.
利用固相萃取柱对样品进行前处理,采用胃袋式大体积进样技术结合气相色谱-质谱(GC-MS),建立了大米中13种有机磷农药的快速分析方法.以保留时间和特征离子丰度比进行定性,以峰面积外标法进行定量.结果表明,除乐果外,其余12种有机磷农药的添加回收率为82%~96%,RSD为2.09%~9.09%,检出限(S/N=3)为0.03~5 μg/kg.  相似文献   

2.
建立了银渍硅胶固相萃取柱离线(Ag-SPE)净化,程序升温进样-气相色谱-氢火焰离子化检测器(PTV-GC-FID)定量分析巧克力中饱和烷烃矿物油(MOSH)的方法.以正己烷浸泡提取巧克力中的MOSH,离心后取1 mL上清液,过0.3% Ag渍硅胶SPE柱净化,氮吹浓缩,定容至0.2 mL,注入GC分析; GC的进样口程序升温过程:初始温度45℃,保持1 min(分流比200∶1),以250℃/min升温至360℃(分流阀关闭2 min),并保持27 min(分流比100∶1); 进样量40 μL; 柱温箱升温程序为:35℃保持3 min,以25℃/min升温至350℃,以5℃/min升温至370℃,保持10 min,载气为高纯氮气,流速1.3 mL/min(压力60 kPa); FID温度为380℃.结果表明,本方法的MOSH定量限为0.5 mg/kg,加标回收率为84.9%~108.6%,相对标准偏差(RSD)为0.2%~1.5%.运用本方法对25个市售巧克力样品中的MOSH含量进行了测定,3个样品未检出,其余22个样品中MOSH含量为1.09~8.15 mg/kg(其中C16~C35 的含量为0.56~4.43 mg/kg),有3个样品含量高于5.00 mg/kg,为严重污染样品.本方法操作简便,检出限低,适用于巧克力中MOSH的定量测定.  相似文献   

3.
建立水中17种氯代有机物的大体积固相萃取–气相色谱检测方法。样品以3.0 mL/min的流量经大体积样品采样器Cleanert PS固相萃取柱富集,真空抽干后用10.0 mL丙酮洗脱,挥干洗脱液,用1.0 mL正己烷定容,在选定的色谱条件下进行分析。17种氯代有机物的质量浓度在0~100μg/L内与色谱峰面积呈良好的线性关系,相关系数均大于0.999,方法检出限为0.002 5~0.074μg/L。样品加标回收率为81.0%~116.0%,测定结果的相对标准偏差为0.56%~6.80%(n=6)。该方法快速、灵敏、准确,重现性好,具有一定的实用价值,适用于水中17种氯代有机物的同时测定。  相似文献   

4.
建立了固相萃取大体积程序升温进样气相色谱-三重四极杆质谱联用(GC-QqQ-MS/MS)同时测定饮用水中N-亚硝基二甲胺、N-亚硝基甲基乙基胺及N-亚硝基二乙基胺的分析方法。用椰壳活性炭固相萃取小柱萃取水样中待测物组分,少量二氯甲烷洗脱、无水硫酸钠脱水,大体积程序升温进样,气相色谱-三重四极杆质谱联用仪进行多反应监测(MRM)模式检测,外标法定量。3种N-亚硝胺在1~50 ng/L范围内线性关系良好,相关系数(r2)均大于0.999,在饮用水中进行10、20和50 ng/L水平的添加,3种待测物平均加标回收率为94.8%~109%,相对标准偏差(RSD)为4.44%~8.10%(n=5),定量限(LOQ)为0.08~0.7 ng/L。该法灵敏、准确、简单、可靠,适用于饮用水中3种N-亚硝胺组分的痕量检测。  相似文献   

5.
利用微型固相萃取柱对样品进行前处理,采用胃袋式大体积进样技术结合气相色谱-质谱(GC-MS),建立了菠菜中13种有机磷农药残留的同时快速分析方法。以保留时间和特征离子丰度比定性,以峰面积外标法定量,以3倍信噪比实验值确定方法的检出限(LODs),以10倍信噪比实验值确定方法的定量限(LOQs)。结果表明,除乐果外,其余12种有机磷农药的添加回收率为76.8%~114.0%,相对标准偏差为1.5%~17.6%,LODs为0.5~25 μg/kg。该方法前处理简单快速,分析成本低,分析时间短,灵敏度、准确度和精密度均符合农药多残留检测技术的要求,适用于食品中多种有机磷农药残留的快速灵敏检测。  相似文献   

6.
分别选取菠菜、洋白菜、苹果、大米和大豆5种基质,利用微型固相萃取柱对样品进行前处理,采用胃袋式大体积进样技术结合气相色谱-质谱(GC-MS),建立了同时测定日本通关检测项目要求的205种农药残留的快速分析方法.通过增加进样量提高检测灵敏度,通过减少样品处理量缩短前处理时间,以保留时间和特征离子丰度比进行定性,以特征离子强度进行定量.该方法与日本通知法进行了比对,结果表明两种方法净化效果、检出限、回收率和RSD等指标水平相当,平均回收率在80%~120%之间,RSD(n=7)小于10%,满足残留分析方法的要求.  相似文献   

7.
固相萃取-气相色谱法测定水中毒死蜱   总被引:1,自引:0,他引:1  
水样中的毒死蜱经全自动固相萃取仪萃取、乙酸乙酯洗脱后,用气相色谱火焰光度检测法测定,以保留时间定性,外标法定量.结果表明:选用ENVI-18小柱萃取、乙酸乙酯洗脱,在2mL/min的过水速率下取得了良好的回收率.方法的线性范围为0.25~4.0mg/L.r为0.9998,回收率为88.6%~100.6%,相对标准偏差为2.58%~7.34%,最低定量浓度为2.5μg/L.本方法快速、灵敏、准确,并能够很好的排除干扰,可以满足水中痕量毒死蜱的测定.  相似文献   

8.
固相萃取-气相色谱法测定水中四乙基铅含量   总被引:1,自引:0,他引:1  
水样经Supelco C18固相萃取柱富集样品中四乙基铅,用正己烷淋洗,洗脱液于40℃水浴氮吹浓缩至0.5mL,供气相色谱仪测定。用HP-5色谱柱分离,用电子捕获检测器测定。四乙基铅的峰面积与其质量浓度在0.05~5.0μg.L-1范围内呈线性,方法检出限(3S/N)为0.02μg.L-1。在3种不同浓度水平条件下对方法的回收率和精密度进行了试验,测得回收率在89.0%~92.4%之间,测定值的相对标准偏差(n=7)在3.5%~5.0%之间。  相似文献   

9.
10.
刘芃岩  高丽  申杰  刘微  蔡立鹏 《色谱》2010,28(5):517-520
建立了固相微萃取(SPME)-气相色谱法(GC)分析环境水样中痕量邻苯二甲酸酯类化合物(PAEs)的方法。选用100 μm聚二甲基硅烷(PDMS)萃取纤维,在磁力搅拌条件下,对水样中的PAEs萃取富集60 min,然后直接注入GC进样口,在250 ℃温度下解吸4 min后进行分析测定,13种PAEs能得到充分提取和分离。方法的重现性(以相对标准偏差(RSD)计为0.2%~9.7%,检出限为0.02~0.83 μg/L。将本方法应用于白洋淀水样中PAEs的分析检测发现,样品中邻苯二甲酸二异丁酯(DIBP)、邻苯二甲酸二丁酯(DBP)、邻苯二甲酸二(2-乙基己基)酯(DEHP)检出率相对较高。对水样进行两个浓度水平(2.5 μg/L和5.0 μg/L)的加标试验,加标回收率为75.3%~111.0%,RSD为2.1%~8.0%(n=3),能够满足环境水样中痕量PAEs的测定要求。  相似文献   

11.
探讨了硅胶-氰丙基(SiO2/C3-CN,(1 g/0.5 g,6 mL))复合固相萃取柱分离与净化原油中饱和烃和芳烃组分的方法。结果表明:SiO2/C3-CN复合固相萃取柱较单一硅胶(SiO2)小柱的分离效果好,仅使用4.5 mL正己烷和4.5 mL正己烷-二氯甲烷(1∶1)洗脱即可实现饱和烃和芳烃组分的完全分离与满意回收(回收率分别为98%和99%);而单一硅胶小柱存在低环数芳烃化合物(如萘及其甲基系列、苊等)与饱和烃组分的共洗脱现象。通过对原油实物样品的测定,饱和烃和芳烃组分在硅胶-氰丙基复合柱上经正己烷、正己烷-二氯甲烷(体积比1∶1)的洗脱行为与标准混合液完全一致,该方法实用可靠、流程简单、试剂消耗少、精密度良好(RSD为4.2%~8.5%),适用于石油样品中饱和烃和芳烃组分的定量分析。  相似文献   

12.
提出了固相萃取-气相色谱-质谱法测定辐照鱼油中2-烷基环丁酮(2-十二烷基环丁酮和2-十四烷基环丁酮)含量的方法。0.300g辐照鱼油样品用正己烷溶解,ProElut Silica固相萃取柱净化。在气相色谱分离中用HP-5MS色谱柱为固定相,在质谱分析中采用选择离子监测模式。2种2-烷基环丁酮的质量浓度均在0.01~1.0mg·L-1范围内与其峰面积呈线性关系,方法的测定下限(10S/N)为10μg·kg-1。加标回收率在91.2%~96.0%之间,测定值的相对标准偏差(n=6)在3.7%~5.9%之间。  相似文献   

13.
建立了固相萃取/超高效液相色谱-二极管阵列检测(SPE/UPLC-PDA)联用技术测定河水中18种痕量多环芳烃(PAHs)的快速分析方法。通过优化固相萃取条件、流动相体系、色谱条件等因素,7 min内实现了18种多环芳烃的高效分离。在0.05~50 mg/L浓度范围内,18种多环芳烃的浓度与对应峰面积呈良好线性关系,相关系数为0.999 1~0.999 9,检出限为0.08~2.03 ng/L,样品加标回收率为74.5%~103.6%,相对标准偏差(RSD,n=6)为0.5%~2.3%。将该方法应用于九龙江流域龙岩段周边水样的检测,结果可靠。该方法简单环保、灵敏准确、操作快速,可显著提高河水中痕量PAHs的分析效率。  相似文献   

14.
在线固相萃取-高效液相色谱法测定水体中的多环芳烃   总被引:1,自引:0,他引:1  
陈静  戴振宇  许群  张祥民 《分析化学》2014,(12):1785-1790
建立了在线固相萃取-液相色谱测定水体残留的多环芳烃的方法,用于测定自来水中的20种多环芳烃( PAHs)。直接进样1 mL经过过滤的水体样品,其中的被测组分富集在SPE柱( Acclaim PA II,50 mm×4.6 mm,3μm)上,在线完成净化和萃取富集;再通过阀切换将它们转移至分析流路,在Hypersil Green PAH色谱柱(150 mm ×3 mm,3μm)上分离检测。在线固相萃取流路以水和乙腈为流动相,0.4和0.6 mL/min流速梯度富集/萃取和洗脱;分析流路亦以水和乙腈为流动相,0.8 mL/min流速梯度洗脱,采用紫外254 nm检测无荧光效应的苊烯和弱荧光效应的萘,其它的多环芳烃化合物则于不同的荧光检测通道里,在其对应的最大激发/发射波长下灵敏测定。整个分析流程32 min即可完成。20种PAHs的保留时间的相对标准偏差均小于0.2%,色谱峰面积的相对标准偏差均小于1.3%(n=7);在3个浓度数量级范围内峰面积与进样质量浓度的线性相关系数均大于0.9910,0.05μg/L的自来水加标样品的回收率为57%~140%,5μg/L的自来水加标样品的回收率为85%~116%;多数有荧光响应的PAHs的方法检出限均小于0.02μg/L (S/N=3)。  相似文献   

15.
Currently, the concentrations of methylamines in fine particulate matter (PM) are most often measured by aerosol time-of-flight mass spectrometry. A novel method for identification and determination of methylamines and methylamine-N-oxides in fine particles based on solid phase extraction (SPE) coupled with ion chromatography (IC) was developed. The experimental conditions including SPE conditions and chromatographic conditions were optimized. The quartz filter loaded with particulate matter (PM) samples was ultrasonically extracted with 20 mL of methanol and water (1:3, V/V) and the extraction process was repeated twice. After extraction, a total of 60 mL of extraction solvent was dropped into the extraction equipment for SPE. The Agilent AccuBond C18 was chosen for enriching the methylamine, dimethylamine, trimethylamine and trimethylamine-N-oxide in fine particles. Under the optimum conditions, the target species on Agilent AccuBond C18 were washed by 0.5 mL of acetonitrile solution and then concentrated (2 mL) before injecting into IC for analysis. A PRP X-200 (250 mm × 4 mm i.d.) was used for separation of analytes at 25 °C. The mobile phase was a mixture of 3% (V/V) acetonitrile solution and 5 mM nitric acid with the flow rate of 1 mL min–1. The four aliphatic amine species were fully resolved and completely separated within 30 min. The linearity of the four compounds ranged from 0.45 μg kg–1 to 1000 μg kg–1 with precisions of 2%–4% and detection limits of 0.002–0.003 μg m–3. The recoveries of the four aliphatic amine species in real PM samples were higher than 90%. This method was successfully applied in the analysis of real fine PM samples collected in Beijing. The concentrations of trimethylamine and methylamine-N-oxides were in the range of (0.01 ± 0.001) μg m–3–(0.08 ± 0.002) μg m–3 and (0.05 ± 0.001) μg m–3–(0.14 ± 0.002) μg m–3 for Beijing dust and haze PM samples, respectively.  相似文献   

16.
建立了固相萃取-气质联用法同时测定纺织品中的烷基磷酸三酯和芳香基磷酸三酯类阻燃剂的方法.采用乙腈-甲苯(3∶1,Ⅴ/Ⅴ)混合溶液作为提取剂,对纺织品中的磷酸三酯类阻燃剂进行提取;再用ENVI-Carb固相萃取柱对提取液中的目标分析物进行净化处理;氮吹浓缩定容后,用气质联用仪进行定性与定量分析.磷酸三(2,3-二溴丙基)酯在0.050~20 mg/L浓度范围内存在良好的线性关系,相关系数r为0.9859;定量限为0.050 mg/kg (S/N=10).其它目标分析物在0.010~20 mg/L浓度范围内存在良好的线性关系,r为0.9998~1.000;定量限为0.010 mg/kg(S/N=10).本方法成功应用于纺织品中磷酸三酯类阻燃剂的检测,加标回收率在71.4%~102.5%之间;RSD≤4.9(n=6).分析的20个样品中,有一个Ⅰ类样品检出TBP,含量为(62.2±0.3) μg/kg.  相似文献   

17.
建立了利用反相固相萃取、五氟苄基溴衍生、气相色谱分离负化学源质谱同时定性与定量分析15种氯代酸性除草剂的方法.通过对5种品牌不同规格的固相萃取柱的对比实验,最终确定了德国Merk公司生产的LiChrolut柱,在给定的条件下可达最高回收率;通过对不同萃取条件的考察,使其中15种除草剂的回收率均达到70%以上;选择了毒性较低、衍生效率较高、可操作性较强的五氟苄基溴进行衍生;采用不同的气相色谱柱进行实验,优化了升温程序,从而确定了最佳的分离条件;通过对比不同离子源特点及实验数据结果选择了定性准、灵敏度高的负化学源质谱法进行检测,实现了免净化操作,建立了萃取体积小,萃取效率高,适合于气相色谱检测的多组分固相萃取方法,检出限在萃取体积200 mL的条件下即可低于0.01 μg/L,从而为地下水、地表水、饮用水中多目标污染物的同时检测提供了可靠的技术支撑.  相似文献   

18.
《Analytical letters》2012,45(1-3):310-326
The determination of low-level ammonium in seawaters suffers from low sensitivity and high contamination; therefore, it is desirable to develop highly sensitive methods for automatic measurements. A highly sensitive and automated flow technique system for nanomolar level ammonium measurement is described. Reagents for Berthelot reaction were automatically added into seawater samples. After a 10 min reaction at 40°C, the formed indophenol blue compound was on-line extracted onto an Hydrophilic-Lipophilic Balance (HLB) cartridge. The enriched compound was rinsed with water and ethanol solution (30%, v/v) and, in turn, eluted with an eluent containing 30% (v/v) ethanol and 5.0 mM of NaOH, and determined with a spectrophotometer at 640 nm. Parameter, including extraction conditions, reagent concentrations, pH, temperature, and reaction time, were optimized. Under the optimized conditions, the detection limit was 3.5 nM and the linear range was 0–428 nM. The relative standard deviations were 5.7% (n = 8) for 44.6 nM standard solution and less than 6.0% (n = 3–5) for samples within concentrations of about 52.4–288.7 nM; the recovery was in the range 93.6 to 108.5%. The sample throughput was 3 h?1. The proposed method provides a simple, cheap, and automatic way to determine ammonium in seawater samples without complicated sample treatment.  相似文献   

19.
建立了高效液相色谱-荧光检测法同时测定婴幼儿奶粉和米粉中15种多环芳烃的检测方法。样品经乙腈提取,PSA分散固相萃取净化;乙腈-水梯度洗脱,Waters PAH专用柱分离,荧光检测器检测,外标法定量。在最优条件下,15种多环芳烃均得到有效分离,线性范围为1.0~50μg/L,相关系数均大于0.995,方法检出限(LODs,S/N=3)为0.05~0.3μg/kg,回收率为86.5%~106.8%,精密度(RSD,n=6)为0.7%~7.5%。该方法操作简单、灵敏度高,适用于婴幼儿奶粉和米粉中多环芳烃的检测。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号