首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到18条相似文献,搜索用时 82 毫秒
1.
建立了食用菌及其栽培基质中26种多溴联苯醚(PBDEs)的检测方法。考察了不同提取溶剂,不同净化材料,不同仪器条件对检测结果的影响,确立了乙腈提取,盐析分层,乙二胺-N-丙基硅烷(PSA)复合去活化硅胶固相萃取柱净化,气相色谱-电子捕获器(GC-ECD)分析,外标法定量的检测方法。方法的线性相关系数大于0.996,检出限为0.02~0.06μg/kg,定量限为0.06~0.2μg/kg,方法加标回收率在72.5%~119.2%之间,相对标准偏差在2.2%~14%之间。  相似文献   

2.
建立了气相色谱-质谱法(GC-MS)分析土壤中的18种多溴联苯(PBBs)和多溴联苯醚类(PBDEs)化合物的方法.利用快速溶剂萃取(ASE)技术和凝胶净化系统(GPC)进行土壤样品的前处理,(13)C标记物作为进样内标和替代标,采用电子轰击源气相色谱质谱法(GC-EI/MS )分析-溴至七溴代PBBs和PBDEs,负...  相似文献   

3.
Huang F  Zhao Y  Li J  Wu Y 《色谱》2011,29(8):743-749
采用OasisHLB固相萃取柱萃取血清中的多溴联苯醚(PBDEs),经浓硫酸柱上除脂后,利用气相色谱-负化学源质谱法测定BDE-17、28、47、66、99、100、153、154、183和209共10种PBDEs组分。BDE-209的测定采用DB-5 ms色谱柱(15 m×0.25 mm×0.1 μm),其他组分采用VF-5 ms色谱柱(30 m×0.25 mm×0.25 μm)。对样品中蛋白质的去除溶剂和固相萃取条件(如洗脱溶剂及其用量)进行了优化。胎牛血清中的加标回收试验结果显示,各PBDEs单体相对于内标的平均回收率为78.5%~109.7%,日内测定的相对标准偏差(RSD)为0.3%~7.4%,日间测定的RSD为1.4%~14.1%。胎牛血清中三溴~七溴联苯醚的检出限(信噪比为3)为0.10~0.27 ng/L;定量限(信噪比为10)除了BDE-209为7.91 ng/L外,其他PBDEs为0.35~0.91 ng/L。采用本方法测定标准参考物质SRM1957和SRM1958,结果在参考值范围内。实验结果表明,本方法灵敏度高、准确度和精密度好,简便快速,溶剂消耗量少,适用于人体血清中三至十位溴取代联苯醚的测定。  相似文献   

4.
建立全自动固相萃取-气相色谱法同时测定地表水中20种多溴联苯的方法。水样经0.45μm滤膜过滤后用0.05 g/mL氢氧化钠溶液或盐酸溶液(体积比1∶1)调节pH至中性,加入10 mL甲醇作为有机改性剂混匀,通过全自动固相萃取仪以10 mL/min的流量上样,被测物质经PS/DVB固相萃取柱富集后,用正己烷-乙酸乙酯(体积比7∶3)混合溶剂洗脱。采用DB-5MS(15 m×0.25 mm,0.1μm)毛细管柱分离,电子捕获检测器检测,外标法定量。结果表明,20种多溴联苯的质量浓度在5.0~100μg/L范围内线性良好,相关系数均大于0.998,方法检出限为1.3~4.4 ng/L,定量限为5.2~17.6 ng/L,在20.0 ng/L和80.0 ng/L 2种添加水平下平均加标回收率为72.8%~90.9%,相对标准偏差为3.3%~8.5%。该方法自动化程度高、操作简便,具有良好的精密性和准确性,可以满足地表水中多溴联苯的快速测定要求。  相似文献   

5.
田孟魁  冯喜兰 《中国化学》2008,26(7):1251-1256
建立了顶空固相微萃取联结气相色谱-电子捕获检测器(HS-SPME-GC-ECD)测定水中多溴联苯醚的方法。制作了多壁碳纳米管涂层固相微萃取探头。优化了萃取时间,萃取温度,搅拌速度,顶空体积,溶液的pH,离子强度及有机溶剂等影响萃取效率的各种因素。比较了室温和100 ℃顶空萃取和直接萃取的效率。结果表明,室温下直接萃取比顶空萃取的效率高2-4倍,而在100 ℃时顶空萃取比直接萃取的效率高1-8倍。除BDE-154外,无论直接萃取还是顶空萃取,100 ℃时的萃取效率均高于室温。方法的线性范围50-1600 ng/L,相关系数为0.995-0.998,5种多溴联苯醚的最低检出限(S/N=3)为1.14-16.25 ng/L,相对标准偏差(RSD%,n=5)小于10%。本方法用于真实水样的测定,回收率为74.2%-98.7%。  相似文献   

6.
建立了同时测定土壤中7种多溴联苯醚(PBDEs)的超声微波协同萃取/气相色谱测定方法.考察了萃取溶剂的种类和用量、微波功率、萃取时间等因素对模拟土壤中PBDEs回收率的影响,得到了最佳萃取条件:萃取剂为50 mL正己烷-丙酮(1:1),微波辐射功率为90W,萃取时间为10 min.在最佳条件下,PB-DEs在10~40...  相似文献   

7.
建立了固相萃取-浓硫酸净化-气相色谱/三重四极杆串联质谱(SPE-GC-MS/MS)分析水中8种多溴联苯醚(PBDEs,BDE-28,BDE-47,BDE-99,BDE 100,BDE-153,BDE-154,BDE-183和BDE-209)的方法。方法采用改进的色谱柱可同时分析高溴代联苯醚BDE209,采用浓硫酸净化固相萃取后的样品和串联质谱特有的多反应监测模式,可以很好地去除基质干扰和提高定性的准确性。通过优化三重四极杆串联质谱的碰撞电压、扫描峰宽和离子对等条件,使8种多溴联苯醚的检测灵敏度显著提高。8种多溴联苯醚的浓度在0.1~50 ng/mL(BDE209:1~500 ng/mL)范围内线性良好,回归系数均大于0.9997。方法回收率在49%~110%,相对标准偏差在1.4%~6.0%之间。方法可用于实际地表水体中PBDEs的定量检测。  相似文献   

8.
魏丹  国明  吴慧珍  张菊 《色谱》2020,38(8):945-952
建立了加速溶剂萃取(ASE)、磁固相萃取净化(MSPE)、气相色谱-质谱(GC-MS)测定土壤中多环芳烃和有机氯残留的方法。ASE萃取溶剂为丙酮-正己烷(1∶1, v/v),萃取温度为100℃,萃取压力为11.032 MPa,加热时间为5 min,静态萃取时间为5 min,循环萃取3次,冲洗体积为60%萃取池体积,氮气吹扫100 s。然后采用室温制备法自制ZIF-8/nZVI磁性材料用于净化萃取液,将净化液浓缩定容后进行GC-MS测定。多环芳烃和有机氯的线性范围为5~200μg/kg,线性相关系数(r2)均大于0.99;目标物的检出限(LOD,S/N=3)为0.04~1.21μg/kg。所建方法成功用于土壤样品中16种多环芳烃和23种有机氯的测定,在3个加标水平下得到的加标回收率为63.9%~112.1%,相对标准偏差(RSD)为0.4%~26.2%。研究结果表明,该方法具有灵敏度高、重现性好、回收率高等特点,适用于土壤中多环芳烃和有机氯残留的检测。  相似文献   

9.
建立了微波辅助萃取-气相色谱质谱法测定生物样品中的多溴联苯醚(PBDEs)的方法,优化了萃取剂的种类、萃取剂用量、萃取时间等微波萃取条件和GC-MS仪器分析条件。正己烷-丙酮混合溶剂提取后,经实验室自制的多层硅胶柱分离纯化,用气相色谱-质谱进行测定,该方法基质加标回收率在60%~77%之间,相对标准偏差在11%~18%之间,方法的检测限为0.03~0.20ng/g,适用于生物样品中PBDEs的测定。  相似文献   

10.
利用气相色谱-电子捕获检测器(GC-ECD),建立了牡蛎中11种多溴联苯醚(PBDEs)同时测定方法。优化了气相法与质谱联用法仪器条件,考察了不同提取溶液、固相萃取柱、净化方式等前处理条件对提取和净化效果的影响。结果表明,GC-ECD对高溴组分更灵敏;牡蛎加标样品经正己烷-二氯甲烷(1:1,V/V)提取,弗洛里硅土柱-浓硫酸净化,GC-ECD测定,PBDEs各组分标准曲线线性良好(r 0. 998),二至九溴联苯醚和十溴联苯醚方法检出限分别为0. 05 ng/g和0. 1 ng/g,回收率范围为80. 3%~104%,相对标准偏差范围为3. 0%~12%。方法可用于牡蛎中二至十溴联苯醚同时检测。  相似文献   

11.
A solid phase extraction (SPE) method in combination with silica gel cleanup to analyse tri-to heptabrominated diphenyl ethers in human plasma was validated. All congeners showed recoveries over 70% except for BDE #183, which showed recoveries around 45%. The method was tested on 21 individual plasma samples which were extracted with both the SPE method and an open column extraction method using Hydromatrix. Method detection limits were of the same order of magnitude for both methods, ranging from 0.0076 to 0.13 ng g–1 (l.w.) depending on the congener. The SPE extraction method meets the demand for a faster, less solvent-and sample-demanding method with lower contamination risk due to fewer steps compared to the open column extraction.Acknowledgements The Knowledge Foundation in Sweden is acknowledged for supporting this project financially. Brock Chittim, Wellington Laboratories, Guelph, Canada is acknowledged for providing BDE standards. Dr. Cathrine Thomsen at the National Institute for Public Health, Oslo, Norway is acknowledged for helpful discussions and instruction of solid phase extraction. Anne-Marie Porat at Haluxa, Sweden is acknowledged for the blood sampling of the electronic dismantling workers. Personnel at WÅAB are acknowledged for their support in the different sampling events.  相似文献   

12.
气相色谱-负化学电离源质谱法测定土壤中的多溴联苯醚   总被引:3,自引:0,他引:3  
金军  刘伟志  王英  彭浩  唐孝炎 《化学通报》2007,70(11):847-851
本文建立了气相色谱-负化学电离源质谱(GC-NCI-MS)法分析环境土壤及底泥样品中多溴联苯醚(PBDEs)的方法。样品采用索氏提取、多层硅胶柱分离纯化、内标法(BDE28、47、99、100、153、154、183)及同位素稀释法(BDE209)定量。上述定量的8种BDE同族体的方法回收率在96.7%~138.5%之间,相对标准偏差(RSD)为9.1%~22.3%(n=4)。应用该方法分析环境土壤及底泥样品的结果表明,8种所监测的PBDEs均被检出,土壤中PBDE浓度的总和为1437.6ng/g干重,底泥中为241.4ng/g干重,土壤和底泥中BDE209分别占PBDE浓度的总和的98.4%和92.7%。  相似文献   

13.
提出了粮食中α-硫丹、β-硫丹、硫丹乙酯、硫丹丙酯和硫丹硫酸盐5种硫丹类有机氯农药的气相色谱测定方法。样品粉碎后以丙酮为溶剂经快速溶剂萃取仪在加热(80℃)状态下静态提取5min、氟罗里硅土固相萃取柱净化后注入毛细管气相色谱仪分离测定。5种硫丹类农药的测定下限(10S/N)分别为0.82~1.75μg.kg-1,平均回收率为88.9%~99.1%,相对标准偏差(n=5)为6.80%~10.23%。  相似文献   

14.
鱼肉组织中多溴联苯醚的定量分析   总被引:9,自引:0,他引:9  
多溴联苯醚(PBDEs)是一类广泛用于家用电器、电子产品、塑料泡沫、家居装饰材料等行业的添加型阻燃剂[1],使用量最多的是五溴联苯醚(penta-BDE),八溴联苯醚(octa-BDE)和十溴联苯醚(deca-BDE)3种[2]。最近的研究表明[4-6],多溴联苯醚已广泛地存在于各种环境介质、生物体及人体中  相似文献   

15.
建立了咸鱼中有机磷农药残留的分析方法.乙腈为溶剂,样品经ASE萃取,提取液用凝胶渗透色谱除去脂类、蛋白质和大部分的色素,再经Carb/PSA小柱净化.采用GC-MS定性分析,GC-FPD定量分析.加标水平为0.05~0.20mg/kg时,农药的回收率为64.5%~98.6%,相对标准偏差2.7%~14.7%.方法的检出...  相似文献   

16.
建立了测定纺织品中壬基酚聚氧乙烯醚和辛基酚聚氧乙烯醚的硅胶吸附色谱-电喷雾质谱分析方法.不同类型的纺织品样品采用加速溶剂萃取法,以无水乙醇为提取溶剂,在10.3 MPa和100 ℃下静态循环提取2次,提取液经Sep-Pak Carbon/NH2石墨化碳黑/氨基复合型固相萃取柱净化,以Waters Spherisorb S3W(150 mm×2.0 mm, 3 μm)色谱柱为分离柱,乙腈-水体系为流动相梯度洗脱,在电喷雾质谱正离子模式下进行定性及定量分析.壬基酚聚氧乙烯醚的方法检出限为10~40 μg/kg,在1~20 mg/kg的3个添加水平范围内的平均回收率为81.4%~95.9%,相对标准偏差均小于12.5%.辛基酚聚氧乙烯醚的方法检出限为10~30 μg/kg,在1~20 mg/kg的3个添加水平范围内的平均回收率为80.2%~96.8%, 相对标准偏差均小于13.0%.本方法准确、简便、快速,可用于纺织品的实际检验工作.  相似文献   

17.
利用柱前衍生化耦合气相/质谱/质谱(GC/MS/MS),建立了细胞培养液中13种多溴联苯醚(PBDEs)、8种甲氧基化多溴联苯醚(MeO-PBDEs)和5种羟基化多溴联苯醚(HO-PBDEs)的分析方法.采用氯甲酸甲酯作为HO-PBDEs的衍生化试剂,相比传统重氮甲烷作为衍生化试剂的方法,其衍生化时间明显缩短.同时,衍...  相似文献   

18.
研究了加速溶剂萃取( ASE)、固相萃取柱净化( SPE)、高效液相色谱( HPLC)联合( ASE-SPE-HPLC)测定土壤及蚯蚓样品中7种多环芳烃(PAHs)的分析方法,确定了以正己烷-丙酮(4∶1, V/V)作为萃取剂,用ASE对土壤及蚯蚓进行萃取,提取液经SPE柱净化(土壤样品用硅胶柱净化,蚯蚓样品用 Al2 O3-硅胶柱净化),正己烷-二氯甲烷(9∶1, V/V)进行洗脱,洗脱体积为10 mL,旋转浓缩蒸干后,乙腈定容,过0.22μm有机滤膜,最后用HPLC对提取液中7种PAHs进行定量的分析方法。土壤样品方法回收率在83.5%~110.2%之间,相对标准偏差为1.0%~4.6%;蚯蚓样品回收率在81.2%~97.1%之间,相对标准偏差为1.6%~4.2%。方法检出限为0.15~0.85μg/kg,且重现性好。可满足样品分析的质量控制要求,表明本分析方法具有良好的准确性与可靠性。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号