共查询到20条相似文献,搜索用时 15 毫秒
1.
I. L. Davies M. W. Raynor D. J. Urwin K. D. Bartle M. Tolay E. Ekinci H. E. Schwartz 《Journal of separation science》1988,11(11):792-799
This work describes the analysis of a pyrolysis product of a lignite sample obtained from the Turkish Goynuk reserve. The aliphatic, aromatic and polar compounds present in the tar are separated and identified by various chromatographic techniques: Capillary gas chromatography/mass spectrometry (GC/MS), on-line high performance microbore liquid chromatography/capillary gas chromatography (LC/GC) and capillary supercritical fluid chromatography (SFC). The suitability of each technique for this particular application is discussed, and semi-quantitative results are presented for the major components detected. 相似文献
2.
Eight polybrominated diphenyl ether (PBDE) congeners of primary interest to the US EPA were separated using reverse-phase
liquid chromatography on an octadecylsilane column. BDE-28, BDE-47, BDE-99, BDE-100, BDE-153, BDE-154, BDE-183, and BDE-209
were baseline-resolved under isocratic conditions in 92:8 methanol/water (v/v). Negative-ion atmospheric pressure photoionization
(NI-APPI) with a toluene dopant produced precursor ions corresponding to [M–Br+O]– for the eight congeners studied. Each congener was quantified by tandem mass spectrometry through a unique multiple reaction
monitoring (MRM) transition. On-column limits of detection were between 2.4 and 27.8 pg for the eight congeners studied, with
an intra-day method precision of 9%. The LC/NI-APPI/MS/MS method was validated for the analysis of the eight PBDE congeners
in NIST SRM 2585 (Organics in House Dust). Pressurized liquid extraction (PLE) with subsequent LC/NI-APPI/MS/MS analysis afforded
quantitative recovery for all eight PBDE congeners with recoveries ranging from 92.7 to 113%. The liquid-phase separation
of the LC/NI-APPI/MS/MS method is not prone to the thermal degradation issues that plague splitless GC based analyses of highly
brominated PBDEs such as BDE-209. 相似文献
3.
Sonemoto E Kono N Ikeda R Wada M Ueki Y Nakashima K 《Biomedical chromatography : BMC》2012,26(11):1297-1300
A rapid and simple liquid chromatography tandem mass spectrometry method for determination of methotrexate (MTX) in rheumatic patients' serum is described. Serum spiked with pterin as an internal standard was deproteinized with methanol. The separation of MTX from interfering peaks in matrix was achieved on a Luna 3 µm C18 (100 × 4.6 mm i.d.) column with a mixture of 1% acetic acid and acetonitrile (88:12, v/v) within 5 min. Multiple reaction monitoring transitions monitored for MTX were m/z 455.2–308.1. The calibration curve of MTX in serum showed a good linearity (r = 0.999). Limits of detection and quantification of MTX at a signal‐to‐noise ratio of 3 and 10 were 3.0 n m (4.4 fmol/injection) and 10.0 n m (14.5 fmol/injection), respectively. The accuracy and precision for intra‐ and inter‐day assays were 94.6–106.5% and <5.5 and <5.1%, respectively. Furthermore, the proposed method was successfully applied to the sera nine rheumatic patients receiving MTX treatment. Copyright © 2012 John Wiley & Sons, Ltd. 相似文献
4.
S. A. Martlin R. H. Zhou D. E. Games A. Jones E. D. Ramsey 《Journal of separation science》1984,7(4):196-202
Conditions are reported for the reverse-phase HPLC analysis of gossypol and of some of its derivatives, including anhydrogossypol, gossypolone, gossypol hexaacetate, and Schiff's base derivatives. It is shown that field desorption (FD) and chemical ionization (CI) mass spectrometry have advantages over electron impact (EI) mass spectrometry for the characterization of these compounds and that combined high-performance liquid chromatography/mass spectrometry (LC/MS), especially when used in the CI mode, is particularly effective. 相似文献
5.
Yanlin Zhu Guiying Chen Kerong Zhang Chang Chen Weiqing Chen Mingshe Zhu Hongliang Jiang 《Molecules (Basel, Switzerland)》2022,27(22)
CYP-mediated fast metabolism may lead to poor bioavailability, fast drug clearance and significant drug interaction. Thus, metabolic stability screening in human liver microsomes (HLM) followed by metabolic soft-spot identification (MSSID) is routinely conducted in drug discovery. Liver microsomal incubations of testing compounds with fixed single or multiple incubation time(s) and quantitative and qualitative analysis of metabolites using high-resolution mass spectrometry are routinely employed in MSSID assays. The major objective of this study was to develop and validate a simple, effective, and high-throughput assay for determining metabolic soft-spots of testing compounds in liver microsomes using a single variable incubation time and LC/UV/MS. Model compounds (verapamil, dextromethorphan, buspirone, mirtazapine, saquinavir, midazolam, amodiaquine) were incubated at 3 or 5 µM with HLM for a single variable incubation time between 1 and 60 min based on predetermined metabolic stability data. As a result, disappearances of the parents were around 20–40%, and only one or a few primary metabolites were generated as major metabolite(s) without notable formation of secondary metabolites. The unique metabolite profiles generated from the optimal incubation conditions enabled LC/UV to perform direct quantitative estimation for identifying major metabolites. Consequently, structural characterization by LC/MS focused on one or a few major primary metabolite(s) rather than many metabolites including secondary metabolites. Furthermore, generic data-dependent acquisition methods were utilized to enable Q-TOF and Qtrap to continuously record full MS and MS/MS spectral data of major metabolites for post-acquisition data-mining and interpretation. Results from analyzing metabolic soft-spots of the seven model compounds demonstrated that the novel MSSID assay can substantially simplify metabolic soft-spot identification and is well suited for high-throughput analysis in lead optimization. 相似文献
6.
We developed a method to analyze the fingerprint spectrum qualitatively and quantitatively for the traditional Chinese herbal medicinal preparation Gan-Lu-Yin with HPLC combined with photodiode array detection, and MS, and to identify the preparation's 14 main components including baicalin, baicalein, oroxylin A-7-O-glucuronide, wogonin-7-O-glucuronide, wogonin, and oroxylin A in Radix Scutellariae; naringin and neohesperidin in Aurantii fructus; liquiritigenin, liquiritin, and glycyrrhizic acid in Radix Glycyrrhizae. In LC/UV assay, a Cosmosil 5C18-MS-II column was used as the stationary phase, and a gradient of potassium dihydrogen phosphate, ACN, and water as the elute solution. The UV detection wavelengths were 250 and 280 nm. In LC/MS assay, a gradient of phosphoric acid, ACN, and water was used as the elute solution, and electrospray positive ion mode ((+)-ESI) as the analytic mode. In order to explore the distribution of trace metal elements effectively in Gan-Lu-Yin, a microwave digestion method was used for sample treatment, and an inductively coupled plasma MS assay was used to analyze fingerprint spectra of the inorganic metals in Gan-Lu-Yin. Combined with fingerprint spectra of organic compounds by LC/UV and LC/MS, it was expected to provide effective quality control in the production of Gan-Lu-Yin. 相似文献
7.
Jelena Klawitter Yan Ling Zhang Jost Klawitter Nora Anderson Natalie J. Serkova Uwe Christians 《Biomedical chromatography : BMC》2009,23(12):1251-1258
We developed and validated a semi‐automated LC/LC‐MS/MS assay for the quantification of imatinib in human whole blood and leukemia cells. After protein precipitation, samples were injected into the HPLC system and trapped onto the enrichment column (flow 5 mL/min); extracts were back‐flushed onto the analytical column. Ion transitions [M + H]+ of imatinib (m/z = 494.3 → 394.3) and its internal standard trazodone (372.5 → 176.3) were monitored. The range of reliable response was 0.03–75 ng/mL. The inter‐day precisions were: 8.4% (0.03 ng/mL), 7.2% (0.1 ng/mL), 6.5% (1 ng/mL), 8.2% (10 ng/mL) and 4.3% (75 ng/mL) with no interference from ion suppression. Autosampler stability was 24 hs and samples were stable over three freeze–thaw cycles. This semi‐automated method is simple with only one manual step, uses a commercially available internal standard, and has proven to be robust in larger studies. Copyright © 2009 John Wiley & Sons, Ltd. 相似文献
8.
Combined quantification of paclitaxel,docetaxel and ritonavir in human feces and urine using LC‐MS/MS 下载免费PDF全文
Jeroen J. M. A. Hendrikx Hilde Rosing Alfred H. Schinkel Jan H. M. Schellens Jos H. Beijnen 《Biomedical chromatography : BMC》2014,28(2):302-310
A combined assay for the determination of paclitaxel, docetaxel and ritonavir in human feces and urine is described. The drugs were extracted from 200 μL urine or 50 mg feces followed by high‐performance liquid chromatography analysis coupled with positive ionization electrospray tandem mass spectrometry. The validation program included calibration model, accuracy and precision, carry‐over, dilution test, specificity and selectivity, matrix effect, recovery and stability. Acceptance criteria were according to US Food and Drug Administration guidelines on bioanalytical method validation. The validated range was 0.5–500 ng/mL for paclitaxel and docetaxel, 2–2000 ng/mL for ritonavir in urine, 2–2000 ng/mg for paclitaxel and docetaxel, and 8–8000 ng/mg for ritonavir in feces. Inter‐assay accuracy and precision were tested for all analytes at four concentration levels and were within 8.5% and <10.2%, respectively, in both matrices. Recovery at three concentration levels was between 77 and 94% in feces samples and between 69 and 85% in urine samples. Method development, including feces homogenization and spiking blank urine samples, are discussed. We demonstrated that each of the applied drugs could be quantified successfully in urine and feces using the described assay. The method was successfully applied for quantification of the analytes in feces and urine samples of patients. Copyright © 2013 John Wiley & Sons, Ltd. 相似文献
9.
10.
Isoginkgetin is a biflavonoid compound isolated from the leaf extracts of Ginkgo biloba. In this study, an liquid chromatography–tandem mass spectrometry (LC/MS/MS) with liquid–liquid extraction was developed and validated for the analysis of isoginkgetin in rat plasma. In the process of chromatographic separation, selected reaction monitoring transitions for isoginkgetin and IS were m/z 566.8 → 134.7 and m/z 430.8 → 269.3, respectively. The validation parameters including selectivity, linearity, LLOQ, accuracy, precision, matrix effect, stability and recovery were satisfactory. The intra‐ and inter‐batch precision (RSD) were <12.1% in plasma, while the accuracy (RE) was within ±14.3%. This method was employed in a pharmacokinetic study on rats after the intravenous administration of isoginkgetin. 相似文献
11.
Catecholamines are biogenic amines that play an important role in the nervous system. Some catecholamines have been used as tumor makers of phenochromocytoma, paraganglioma and neuroblastoma. The analysis of total catecholamine metabolites should be useful for one-shot screening of multiple aspects of diseases; however, it is difficult to do this, because the catecholamine metabolites are divided into three groups: five amines, one amino acid and three carbonic acids. Catecholamines and small molecules were separated from plasma proteins by an internal-surface reversed-phase column (protein-coated octadeyclsilica column) and were analyzed by liquid chromatography (LC)/mass spectrometry (MS) using electrospray ionization time-of-flight MS. Using a reversed-phase column and hydrophilic mobile phases, we succeeded in the separation of nine catecholamines, all of which had similar structures. These nine substances were eluted in the following order: norepinephrine, epinephrine, normetanephrine, dopamine, metanephrine, 3,4-dihydroxyphenylalanine, vanillomandelic acid, 3,4-dihydroxyphenylacetic acid and homovanillic acid. The reproducibility of this method was acceptable. The highest coefficient of variation was 7.4%. In addition, various types of compounds were separated from and detected in plasma proteins by applying LC/MS. The plasma direct injection method, which uses an internal-surface reversed-phase column and an ion-pair reagent, allowed us to separate small molecules from plasma proteins. MS detected some compounds that high-performance LC could not succeed in separating and detecting with UV detection. We think that the method can be applied to find new markers in neuroblastoma, by comparing the plasma of patients with that of normal infants. The method can be also used to help in making a diagnosis of other diseases and finding their new makers. 相似文献
12.
Identification of dyes in historic textiles was until recently only based on reversed phase liquid chromatography and diode-array detection (RPLC–DAD). Although in the last years mass spectrometry (MS) is increasingly used as a detection system for liquid chromatography, most applications in the field are directed to identification of the molecular ions or in studies dedicated to degradation products which may be used as markers in RPLC–DAD. In the present work, an analytical protocol for the identification of dyes using RPLC/ESI/MS is presented. Atmospheric pressure electrospray ionization (ESI) was applied, in the negative ion monitoring mode. Both single stage and tandem MS (MS/MS) approaches were considered. An ion trap was used as mass analyzer. Experiments are based on the characterization of standards (natural dyes and/or dyed fibers) with the mass spectrometer sequentially working in the following modes: single MS/full scan, followed by plotting chromatograms through ion extraction (IEC) according to mass/charge ratios corresponding to molecular ions; single MS/selected ion monitoring (SIM) mode; tandem MS/single reaction monitoring (SRM) mode; tandem MS/multiple reactions monitoring (MRM) or product ion scanning modes. A faster chromatographic separation could be applied as MS detection readily balanced the selectivity of the analytical process. In a case study, 11 dyes from 3 biological sources were detected in a 0.5 mg historic sample. 相似文献
13.
高效液相色谱-串联质谱法测定食品包装材料中全氟辛烷磺酰基化合物(PFOS) 总被引:2,自引:0,他引:2
建立了用高效液相色谱-串联质谱(HPLC/MS/MS)结合快速溶剂萃取测定食品包装材料中全氟辛烷磺酰基化合物(PFOS)的方法。采用乙腈溶剂,快速溶剂提取食品包装材料中的PFOS,提取液经0.2μm有机滤膜过滤后,以V(乙腈)∶V(10 mmol/L乙酸铵溶液)=80∶20为流动相,经HPLC分离后用多级反应监测(MRM)方式测定。用两个子离子的相对丰度定性,外标法定量。PFOS在0.002~0.1μg/mL范围内线性良好(R2=0.998),回收率为93.8%~101%,精密度RSD为1.6%~3.1%,方法检出限为0.4μg/m2(S/N≥10),满足欧盟法规对食品包装材料中PFOS的限量检测要求。方法可用于食品包装材料中PFOS的检测。 相似文献
14.
A sensitive LC/MS/MS assay for determining zidovudine (ZDV) and lamivudine (3TC) in human plasma was validated to support antiretroviral pharmacology research programs. After addition of stable labeled isotopic zidovudine (ZDV‐IS) and lamivudine (3TC‐IS) as internal standard, a solid‐phase extraction was performed with an Oasis HLB 1 cm3 cartridge, with recoveries of 92.3% for ZDV and 93.9% for 3TC. A Phenomonex Synergi Hydro‐RP (2.0 × 150 mm) reversed‐phase analytical column was utilized for chromatographic separation. The mobile phase consisted of an aqueous solution of 15% acetonitrile and 0.1% acetic acid. Detection was accomplished by ESI/MS/MS in the positive ion mode, monitoring 268/127, 271/130, 230/112 and 233/115 transitions, for ZDV, ZDV‐IS, 3TC and 3TC‐IS, respectively. The method was linear from 1 to 3000 ng/mL with a minimum quantifiable limit of 1 ng/mL when 100 μL of plasma was analyzed. Validation results demonstrated high accuracy (≤8.3% deviation) and high precision (≤10% CV) for the quality control samples. The method was also shown to be specific and reproducible. The value of the high sensitivity was demonstrated by quantitation of approximately 100 existing samples that had ZDV below the limit of quantitation using a previously validated, less sensitive HPLC‐UV method utilized in the laboratory. Copyright © 2011 John Wiley & Sons, Ltd. 相似文献
15.
16.
Xiaoyan Xia Bernard S. Crimmins Philip K. Hopke James J. Pagano Michael S. Milligan Thomas M. Holsen 《Analytical and bioanalytical chemistry》2009,395(2):457-463
Toxaphene is considered to be a problematic organochlorine pollutant because of its bioaccumulation potential and persistence
in aquatic environments. In this study, whole lake trout and walleye composites were used to evaluate two analytical techniques
for total toxaphene and selected congener analysis. The efficacy of using gas chromatography electron ionization tandem mass
spectrometry (GC-EI/MS/MS) and electron capture negative ionization mass spectrometry (GC-ECNI-MS) were compared. Although
the sensitivity using GC-ECNI-MS was approximately five times greater than GC-EI/MS/MS, the latter provided more consistent
inter-Parlar relative response factors (RRF). When using technical calibration mixtures, these results suggest a more accurate
total toxaphene measurement was obtained using the GC-EI/MS/MS method. Total toxaphene concentrations in lake trout composites
from both methods were highly correlated (R
2 = 0.985) with the MS/MS concentrations approximately half of those determined by ECNI, suggesting systematic high bias in
toxaphene concentrations when measured using GC-ECNI. 相似文献
17.
建立了一种液相色谱-二极管阵列检测器(LC-DAD)/离子阱质谱(IT MS)对水中5种微囊藻毒素(microcystins)的分析方法。水中的微囊藻毒素经固相萃取富集和净化,经LC分离后,采用DAD和IT MS定性分析,DAD定量分析。在优化的条件下,水中5种微囊藻毒素的检出限为0.1 μg/L; 3个质量浓度加标水平(0.2、0.8和5 μg/L)的平均回收率为52.2%~115.2%,相对标准偏差为1.2%~10.0%。该方法从紫外吸收光谱和质谱角度同时进行定性定量分析,可用于地表水和饮用水中多种微囊藻毒素的检测。 相似文献
18.
So Hyun Kim Jeongmi Lee Taehyung Yoon Jangduck Choi Dongmi Choi Deukjoon Kim Sung Won Kwon 《Biomedical chromatography : BMC》2009,23(12):1259-1265
The safety of dietary supplements is questionable as there have been occasional reports of products contaminated with illegal adulterants. The present study was carried out to develop trustworthy methodologies to screen for six anti‐diabetic drugs (phenformin, rosiglitazone, glipizide, glimepiride, glybenclamide and gliclazide) and six anti‐obesity drugs (ephedrine, fenfluramine, T3, T4, fluoxetine and sibutramine) in dietary supplements. A simultaneous determination method of the 12 drugs by liquid chromatography coupled with a photodiode array (LC/PDA) was established and was validated for linearity (r2 > 0.99), precision (RSD <13.3%), recoveries (88.8–115.9%) and reproducibility. Sibutramine and its analogs, N‐desmethylsibutramine, were subject to further investigation by LC/MS/MS because they were one of the major illegal adulterants. Our proposed method to monitor illegal drug adulterations in dietary supplements using LC/PDA is a simple and reliable, and therefore applicable to routine drug‐adulteration screening. Copyright © 2009 John Wiley & Sons, Ltd. 相似文献
19.
超高效液相色谱/串联质谱法分析水中的微囊藻毒素 总被引:17,自引:0,他引:17
建立了超高效液相色谱/质谱快速、准确、高灵敏度地测定水体中痕量微囊藻毒素(MCYST)的分析方法,并用于实 际样品的分析。采用固相萃取法富集净化样品。该法在5 min内即可完成4种MCYST(LR、RR、LW、LF)的分离及检测;LR 、RR、LW、LF的定量检测限、回收率分别为1.3~6.0 ng/L、91.1%~111%;工作曲线的线性相关系数大于0.99,线性范 围达3个数量级。实际样品分析表明,在所测定的水库水样中均检出了LR和RR,其质量浓度分别为0.0447~2.73 μg/L和0.0208~1.36 μg/L;而在所有的检测样品中均未检出LW和LF。 相似文献
20.
Simon T. Lake Phillip M. Altman Jack Vaisman Russell S. Addison 《Biomedical chromatography : BMC》2010,24(8):846-851
A sensitive high‐performance liquid chromatography–tandem mass spectrometric (HPLC‐MS/MS) assay has been developed for the quantitative analysis of vardenafil in human plasma. Vardenafil and the internal standard, alprazolam, were extracted from 0.2 mL aliquots of alkalinized plasma by a single solvent extraction into hexane : dichloromethane. Reversed‐phase chromatographic separation was affected by gradient elution with mobile phases consisting of 10 mM ammonium formate pH 7.0 (solvent A) and methanol (100%, solvent B), delivered at a flow rate of 0.4 mL/min. The analytes were detected by using an electrospray ion source on a 4000 QTrap triple quadrupole mass spectrometer operating in positive ionization mode. The mass transitions were m/z 489.3 → 312.2 for vardenafil and m/z 309.2 → 281.0 for alprazolam. The assay was linear over the concentration range of 0.2–100 ng/mL, with correlation coefficients ≥0.995. The intra‐ and inter‐day precision was less than 5.4% in terms of relative standard deviation and the accuracy was within 12.7% in terms of relative error. The lower limit of quantitation was set at 0.2 ng/mL. The high sensitivity and acceptable performance of the assay allowed its application to the analysis of plasma samples obtained following the oral administration of vardenafil to healthy male volunteers in a pharmacokinetic study. Copyright © 2009 John Wiley & Sons, Ltd. 相似文献