1.
A new automated method for the quantitative analysis of cyproterone acetate (CPA) in human plasma has been developed using on-line solid phase extraction (SPE) prior to the LC-MS/MS determination. The method was based on the use of a pre-column packed with internal-surface reversed-phase material (LiChrospher RP-4 ADS, 25 mm x 2 mm) for sample clean-up coupled to LC separation on an octadecyl silica stationary phase by means of a column switching system. A 30 microl plasma sample volume was injected directly onto the pre-column using a mixture of water, acetonitrile and formic acid (90:10:0.1 (v/v/v)) adjusted to pH 4.0 with diluted ammonia as washing liquid. The analyte was then eluted in the back-flush mode with the LC mobile phase consisting of water, methanol and formic acid (10:90:0.1 (v/v/v)). The dispensing flow rates of the washing liquid and the LC mobile phase were 300 microl min(-1). Medroxyprogesterone acetate (MPA) was used as internal standard. The MS ionization of the analytes was achieved using electrospray (ESI) in the positive ion mode. The pseudomolecular ionic species of CPA and MPA (417.4 and 387.5) were selected to generate daughter ions at 357.4 and 327.5, respectively. Finally, the developed method was validated according to a new approach using accuracy profiles as a decision tool. Very good results with respect to accuracy, detectability, repeatability, intermediate precision and selectivity were obtained. The LOQ of cyproterone acetate was 300 pg ml(-1).  相似文献   

2.
Albendazole is a benzimidazole derivative with a broad-spectrum activity against human and animal helminth parasites. In order to determine the main pharmacokinetic parameters in sheep after oral and intravenous administration of a new formulation of albendazole (an aqueous solution), a fully automated method was developed for the determination of this drug and its main metabolites, albendazole sulfoxide (active metabolite) and sulfone in ovine plasma. This method involves dialysis as purification step, followed by enrichment of the dialysate on a precolumn and liquid chromatography (LC). All sample handling operations were executed automatically by means of an ASTED XL system. After conditioning of the trace enrichment column (TEC) packed with octadecyl silica with pH 6.0 phosphate buffer containing sodium azide, the plasma sample, in which a protein releasing reagent (1 M HCl) containing Triton X-100 was automatically added, was loaded in the donor channel and dialysed on a cellulose acetate membrane in the static-pulsed mode. The dialysis liquid consisted of pH 2.5 phosphate buffer. By rotation of a switching valve, the analytes were eluted from the TEC in the back-flush mode by the LC mobile phase and transferred to the analytical column, packed with octyl silica. The chromatographic separation was performed at 35°C and the analytes were monitored photometrically at 295 nm. Due to the differences in hydrophobic character between albendazole and its metabolites, a gradient elution was applied. The mobile phase consisted of a mixture of acetonitrile and pH 6.0 phosphate buffer. The proportion of organic modifier was increased from 10.0 to 50.1% in 12.30 min, then from 50.1 to 66.9% in 1.70 min. First, the gradient conditions and the temperature were optimised for the LC separation using the DryLab software. Then, the influence of some parameters of the dialysis process on analyte recovery was investigated. Finally, the method developed was validated. The mean recoveries for albendazole and its metabolites were about 70 and 65%, respectively. The limits of quantification for albendazole and its metabolites were 10 and 7.5 ng/ml, respectively.  相似文献   

3.
A specific method for the determination of erythromycin 2'-ethylsuccinate (EM-ES) in plasma is described. The method involves a liquid-liquid extraction procedure followed by the analysis of extracts using phase-system switching (PSS) continuous-flow fast atom bombardment (CF-FAB) liquid chromatography-mass spectrometry (LC-MS). In PSS EM-ES is enriched after analytical separation on a short trapping column, from which it is desorbed to the LC-MS interface. In this way, favourable mobile phases can be used for the LC separation and for the MS detection. Using the PSS approach a flow-rate reduction from 1.0 ml/min in the LC system to 15 microliters/min going into the mass spectrometer was achieved without splitting. The determination limit for EM-ES was 0.1 microgram/ml.  相似文献   

4.
A new kind of silica-based restricted-access material (RAM) has been tested in pre-columns for the on-line solid-phase extraction (SPE) of basic drugs from directly injected plasma samples before their quantitative analysis by reversed-phase liquid chromatography (LC), using the column switching technique. The outer surface of the porous RAM particlescontains hydrophilic diol groups while sulphonic acid groups are bound to the internal surface, which gives the sorbent the properties of a strong cation exchanger towards low molecular mass compounds. Macromolecules such as proteins have no access to the internal surface of the pre-column due to their exclusion from the pores and are then flushed directly out. The retention capability of this novel packing material has been tested for some hydrophilic basic drugs, such as atropine, fenoterol, ipratropium, procaine, sotalol and terbutaline, used as model compounds. The influence of the composition of the washing liquid on the retention of the analytes in the pre-column has been investigated. The elution profiles of the different compounds and the plasma matrix as well as the time needed for the transfer of the analytes from the pre-column to the analytical column were determined in order to deduce the most suitable conditions for the clean-up step and develop on-line methods for the LC determination of these compounds in plasma. The cationic exchange sorbent was also compared to another RAM, namely RP-18 ADS (alkyl diol silica) sorbent with respect to retention capability towards basic analytes.  相似文献   

5.
Analysis of plasma catecholamines (norepinephrine, epinephrine and dopamine) by high-performance liquid chromatography using 1,2-diphenylethylenediamine as a fluorescent reagent is described. We have developed an automatic catecholamine analyser, based on pre-column fluorescence derivatization and column switching. The analysis time for one assay was 15 min. The correlation coefficients of the linear regression equations were greater than 0.9996 in the range 10-10,000 pg/ml. The detection limit, at a signal-to-noise ratio of 3, was 2 pg/ml for dopamine. A new method of sample preparation for the pre-column fluorescence derivatization of plasma catecholamines was used. In order to protect the catecholamines from decomposition, an ion-pair complex between boric acid and the diol group in the catecholamine was formed at a weakly alkaline pH. The stabilities of plasma catecholamines were evaluated at several temperatures. After complex formation, the catecholamines were very stable at 17 degrees C for 8 h, and the coefficients of variation for norepinephrine, epinephrine and dopamine were 1.2, 4.2 and 9.3%, respectively.  相似文献   

6.
A reversed-phase liquid chromatographic column switching system was described for the determination of caffeine (CF), theophylline (TH) and theobromine (TB) in human plasma with a direct injection procedure. A short protein-coated mu Bondapak CN silica pre-column (20 x 3 mm, i.d.) was used for enrichment of the drugs and clean up from weakly retained plasma components using phosphate buffer saline pH 7.4. After washing step, the retained drugs were flushed into a reversed-phase column (5 microm TSK gel ODS-80 TM, 150 x 4.6 mm i.d.) with a mobile phase of methanol-0.01 M phosphate buffer, pH 3.5 (30:70, v/v) for the final separation. The eluent was monitored with a UV detector at 275 nm. The resulting chromatograms showed no interference from endogenous plasma components. A linear relationship between the concentration of drug and peak height was confirmed in the range of 0.5-20 microg/mL for all drugs. High extraction recoveries from plasma ranging from 96.12 to 100.32% were achieved. Validation of the method was examined performing intra- and inter-day accuracy and precision and was found to be satisfactory. The coefficients of variation of the three drugs were less than 3% for intra-day and less than 4% for inter-day run assays.  相似文献   

7.
A fully automated method for the simultaneous determination of verapamil and its main metabolite norverapamil in human plasma is described. This method is based on on-line sample preparation using dialysis followed by clean-up and enrichment of the dialysate on a precolumn and subsequent HPLC analysis with fluorometric detection. All sample handling operations were performed automatically by a sample processor equipped with a robotic arm (ASTED system). The plasma samples were dialysed on a cellulose acetate membrane (cut-off: 15 kD) and the dialysate was purified and enriched on a short pre-column filled with cyanopropyl silica. Before starting dialysis, this trace enrichment column (TEC) was first conditioned with the HPLC mobile phase and then with pH 3.0 acetate buffer. 370 μl of plasma sample spiked with the internal standard (gallopamil) were dialysed in the static-pulsed mode. The solution at the donor side was pH 3.0 acetate buffer containing Triton X-100 while the acceptor solution was made of the same acetate buffer. When dialysis was discontinued, the analytes were desorbed from the TEC by the HPLC mobile phase and transferred to the C18 analytical column by means of a switching valve. This mobile phase consisted of a mixture of acetonitrile, pH 3.0 acetate buffer and 2-aminoheptane. The influence of different parameters of the dialysis process on the recovery of verapamil and norverapamil has been studied. The effect of the volume, the aspirating and dispensing flow-rates of the dialysis solution has been investigated. The recoveries of verapamil and norverapamil in plasma were close to 75% and the limits of quantification were 5 ng/ml for both analytes. The method was found to be linear in the concentration range from 5 to 500 ng/ml (r2: 0.9996 for both analytes). The intra-day and inter-day reproducibilities at a concentration of 100 ng/ml were 2.3% and 5.6% for verapamil and 1.7% and 5.1% for norverapamil, respectively.  相似文献   

8.
A method for on-line high-performance liquid immunoaffinity chromatographic analysis of 5,5-diphenylhydantoin (phenytoin) in human plasma is described. The technique is simple and does not require sample preparation or addition of an internal standard, and the phenytoin is eluted from the columns in 12 min. A phenytoin-specific polyclonal immunoglobulin was attached to an organic silane derivative on silica. The immunosorbent was packed into a short liquid chromatography column and installed in a modified high-performance liquid chromatography system for on-line sample pre-purification. Standard curve linearity of plasma phenytoin was obtained at concentrations up to 160 mumol/l. When compared to conventional high-performance liquid chromatography, plasma phenytoin levels gave a correlation coefficient of 0.993. The phenytoin is highly bound to plasma proteins (ca. 87%). When plasma is injected onto the pre-column, a dissociation and partition of phenytoin from plasma proteins to a complete association with on-column insolubilized antibodies results.  相似文献   

9.
A method for determination of 16 non-steroidal anti-inflammatory drugs (NSAIDs) in human plasma samples without time-consuming sample pre-treatments was developed. The system consisted of two pumps for mobile phase delivery, a six-port switching valve, a pre-column (Oasis HLB Cartridge Column), and a reversed phase analytical column (COSMOSIL 3C18-MS-II). The analytes were trapped on the precolumn and subsequently separated on the analytical column. The present method allowed on-line sample clean-up and enrichment, leading to improved sensitivity without any tedious sample preparation. The recoveries of NSAIDs from human plasma by column-switching were greater than 72.6%. The total analysis time for a single analytical run was approximately 11 min. The detection limits of NSAIDs were 0.0025 to 0.2 microg/mL using the selected ion monitoring mode.  相似文献   

10.
A sensitive, efficient, high throughput, direct injection bioanalytical method based on a single column and high-performance liquid chromatography (HPLC) with tandem mass spectrometry (MS/MS) was developed for pharmacokinetic analysis of early drug discovery compounds in plasma samples. After mixing with a working solution containing an internal standard each plasma sample was directly injected into a polymer-coated mixed-function column for sample cleanup, enrichment and chromatographic separation. The stationary phase incorporates hydrophilic polyoxyethylene groups and hydrophobic groups to the polymer-coated silica. This allows proteins and macromolecules to pass through the column due to restricted access to the surface of the packing while retaining the drug molecules on the bonded hydrophobic phase. The analytes retained in the column with a largely aqueous liquid mobile phase were then chemically separated by switching to a strong organic mobile phase. The column effluent was diverted from waste to the mass spectrometer for analyte detection. Within 200 plasma sample injections the response ratio (analyte vs. internal standard, %CV = 4.6) and the retention times for analyte and internal standard were found consistent and no column deterioration was observed. The recoveries of test compound in various plasma samples were greater than 90%. The total analysis time was 相似文献   

11.
Among the sample preparation techniques, dialysis followed by clean-up and enrichment of the dialysate on a pre-column has proved to be a useful approach for the LC determination of drugs in plasma. By use of sample processors, like the ASTED system, such bioanalytical methods can be fully automated, the dialysis and trace enrichment steps being directly coupled to LC. In order to facilitate the development of such automated methods, a strategy based on a decision tree has been elaborated. After the selection of appropriate conditions for the LC analysis, the decision tree provides information about suggested starting conditions and guidelines for the optimisation of the most important parameters likely to influence analyte recovery and method selectivity. The plasma samples are dialysed on a cellulose acetate membrane in the static-pulsed mode and the dialysate is enriched on a trace enrichment pre-column packed with octadecyl silica or with a strong cation-exchange material. This decision tree is until now restricted to the analysis of basic drugs in plasma. In order to demonstrate the applicability of this method development strategy, an automated procedure based on the coupling of dialysis with trace enrichment has been developed for the LC determination of antifungal agents (clotrimazole, econazole and miconazole) in plasma.  相似文献   

12.
4-(2-Pyridylazo) resorcinol (PAR) and citrate were used as pre-column complexing agents for the determination of Nb(V) and Ta(V) as ternary complexes in geological samples. Aliquots of 2 ml of the standard and sample solutions containing the Nb(V) and Ta(V) complexes were loaded onto a concentrator column (C18, 0.4 cm x 4.6 mm) with a carrier mobile phase comprising 20% (v/v) methanol and containing 5 mM acetic acid, 5 mM citric acid and 10 mM tetrabutylammonium bromide (TBABr), pH 6.5 at 2 ml/min for 2 min, with the effluent being directed to waste. An automatic switching valve was then switched to flush both complexes from the concentrator column onto a C18 analytical column using a mobile phase comprising 32% (v/v) methanol and containing 5 mM acetic acid, 5 mM citric acid and 3 mM TBABr, pH 6.5 for 2.5 min. The switching valve was then switched back to the original position, and cleaned with methanol for 7 min to eliminate unwanted species still adsorbed to the concentrator column. This procedure prevented later eluting compounds from reaching the analytical column, which reduced the overall run time. The detection limits of Nb(V) and Ta(V) (determined at a signal-to-noise ratio of 3, detection wavelength of 540 nm and a 2-ml sample volume) were 0.012 and 0.039 ppb for Nb(V) and Ta(V), respectively. Recoveries of Nb(V) and Ta(V) were 99.4 and 96.2%, respectively. The HPLC results obtained from the reference granite and basalt samples agreed well with inductively coupled plasma MS and certified values, but the HPLC method yielded slightly low values of the Nb/Ta ratio.  相似文献   

13.
A specific and sensitive direct-injection high performance liquid chromatography electrospray ionization tandem mass spectrometry (HPLC/ESI-MS/MS) method has been developed for the rapid identification and quantitative determination of olanzapine, clozapine, and N-desmethylclozapine in human plasma. After the addition of the internal standard dibenzepin and dilution with 0.1% formic acid, plasma samples were injected into the LC/MS/MS system. Proteins and other large biomolecules were removed during an online sample cleanup using an extraction column (1 x 50 mm i.d., 30 microm) with a 100% aqueous mobile phase at a flow rate of 4 mL/min. The extraction column was subsequently brought inline with the analytical column by automatic valve switching. Analytes were separated on a 5 microm Symmetry C18 (Waters) analytical column (3.0 x 150 mm) with a mobile phase of acetonitrile/0.1% formic acid (20:80, v/v) at a flow rate of 0.5 mL/min. The total analysis time was 6 min per sample. The inter- and intra-assay coefficients of variation for all compounds were <11%. By eliminating the need for extensive sample preparation, the proposed method offers very large savings in total analysis time.  相似文献   

14.
The feasibility of directly assaying drugs in physiological fluids using on-line preconcentration and microbore high-performance liquid chromatography has been demonstrated. The untreated sample is injected onto a hydrophobic pre-column, using micellar sodium dodecyl sulfate (SDS) in the case of serum or phosphate buffer in the case of urine, as the load mobile phase. This traps the components of interest which are then backflushed onto a microbore analytical column using a stronger mobile phase. This procedure was then applied to diazepam in serum and phenobarbital in urine. Recovery was linear and quantitative over the range 30-3000 ng/ml for diazepam in serum and 2-200 micrograms/ml for phenobarbital in urine. The diazepam method was specific against caffeine and the three major metabolites of diazepam: oxazepam, temazepam, and nordiazepam. The effects of varying pre-column dimensions, pre-column loading time, and SDS concentration volume were evaluated.  相似文献   

15.
A liquid chromatographic (LC) method with fluorescence detection was developed for concurrent determination of 4 fluoroquinolones: ciprofloxacin (CIPRO), enrofloxacin (ENRO), sarafloxacin (SARA), and difloxacin (DIFLX) in catfish, shrimp, and salmon. The procedure consists of extraction from fish tissue with acidified ethanol, isolation and retention on a cation exchange solid-phase extraction column, elution with basic methanol, and LC analysis with fluorescence detection. LC is performed by isocratic elution with acetonitrile-2% acetic acid (16 + 84) mobile phase, and a PLRP-S polymer column with fluorescence detection, excitation 278 nm and emission 450 nm. A target level of 20 ppb for each of the 4 fluoroquinolones has been established for this method. Fortified and incurred fish sample results are based on a 5-point standard curve calculation (10-160 ppb). Overall percent recoveries (% relative standard deviation) from fortified catfish were 78 (10), 80 (11), 70 (9.4), and 78 (10); from fortified shrimp, 69 (5.9), 85 (4.9), 79 (5.9), and 90 (4.5); and from fortified salmon, 56 (15), 93 (5.6), 61 (11), and 87 (5.0) for CIPRO, ENRO, SARA, and DIFLX, respectively. Data from the analysis of fluoroquinolone-incurred catfish, shrimp, and salmon are presented.  相似文献   

16.
Kahalalide F (KF) is a novel cyclic depsipeptide anticancer drug, which has shown anticancer activity both in vitro and in vivo especially against human prostate cancer cell lines. To characterize the pharmacokinetics of KF during a phase I clinical trial in patients with androgen refractory prostate cancer, a method was developed and validated for the quantitative analysis of KF in human plasma using high-performance liquid chromatography (HPLC) coupled to positive electrospray ionization tandem mass spectrometry (ESI-MS/MS). Microbore reversed-phase liquid chromatography (LC) performed with mobile phases containing trifluoroacetic acid, an additive commonly used for separating peptides, resulted in substantial suppression of the signal for KF on ESI-MS/MS. An alternative approach employing a basic mobile phase provided an excellent response for KF when detected in the positive ion mode. Plasma samples were prepared for LC MS/MS by solid-phase extraction on C(18) cartridges. The LC separation was performed on a Zorbax Extend C(18) column (150 x 2.1 mm i.d., particle size 5 micro m) with acetonitrile -10 mM aqueous ammonia (85 : 15, v/v) as the mobile phase, at a flow-rate of 0.20 ml min(-1). A butyric acid analogue of KF was used as the internal standard. The lower limit of quantitation (LLQ) using a 500 micro l sample volume was 1 ng ml(-1) and the linear dynamic range extended to 1000 ng ml(-1). The inter-assay accuracy of the assay was -15.1% at the LLQ and between -2.68 and -9.05% for quality control solutions ranging in concentration from 2.24 to 715 ng ml(-1). The inter-assay precision was 9.91% or better at these concentrations. The analyte was stable in plasma under all relevant conditions evaluated and for a period of 16 h after reconstituting plasma extracts for LC analysis at ambient temperature.  相似文献   

17.
A simple and sensitive high-performance liquid chromatographic procedure to determine loxoprofen and its diastereomeric alcohol metabolites in biological specimens is described. The analysis involves liquid-liquid extraction with benzene, pre-column derivatization with a highly fluorogenic reagent, 4-bromomethyl-6,7-methylenedioxycoumarin (BrMDC) and subsequent separation on a reversed-phase column. Loxoprofen, its pharmacologically active metabolite, trans-alcohol, and less active cis-alcohol were completely separated within 20 min with a mobile phase of 55% of aqueous acetonitrile containing acetic acid. Any endogenous substances do not interfere in the analysis of either plasma or urine samples. The quantitation limit was 0.01 micrograms/ml for human plasma and 0.05 micrograms/ml for urine. The method was applied to a pharmacokinetic study in healthy human subjects who had received 60 mg of loxoprofen sodium.  相似文献   

18.
An automated high-performance liquid chromatographic (HPLC) column-switching system is described for the analysis of medroxalol, a potential antihypertensive agent, in plasma. The HPLC system uses two six-port switching valves with a Corasil C18 short pre-column for an on-line sample clean-up and an SGE ODS analytical column for separation. Plasma samples were diluted with a phosphate buffer (pH 7.2) containing an internal standard and aliquots were injected directly on the HPLC system. The column-switching system was applicable to continuous analysis of hundreds of plasma samples since this technique provided very efficient on-line sample clean-up and regenerated the pre-column effectively. Results were in good agreement and the total analysis time was one third that of an alternative method.  相似文献   

19.
An highly sensitive and fully automated high-performance liquid chromatographic assay was developed for the determination of a novel non-benzodiazepine anxiolytic (I) [(R)-2-(methoxymethyl)-1-[(7-oxo-8-phenyl-7H-thieno[2,3-a]quinolizin+ ++- 10-yl)carbonyl]pyrrolidine] and its O-demethyl metabolite (II) in plasma, using column-switching for direct injection of plasma samples. After dilution in internal standard solution, the sample was injected onto a pre-column (17 mm x 4.6 mm) dry-packed with pellicular C18 reversed-phase material. Polar plasma components were removed by flushing the pre-column with water-acetonitrile (90:10, v/v). Retained substances, including I and II, were backflushed onto an analytical column, separated by gradient elution and detected by means of fluorescence detection (excitation, 304 nm; emission, 475 nm). After washing the analytical column and re-equilibrating the pre-column, the system was ready for the next injection. The limit of quantification for I and II was 0.25 and 0.5 ng/ml, respectively, using a 350-microliter specimen of plasma. The practicability of the new method was demonstrated by analysis of more than 300 plasma samples from a tolerance study performed with human volunteers. Owing to its high sensitivity, the method can be used to calculate pharmacokinetic parameters of compounds I and II in man after a single oral dose of about 1 mg of I.  相似文献   

20.
The development of a simple and sensitive assay for the quantitative analysis of the marine anticancer agent Yondelis (ET-743, trabectedin) in human plasma using liquid chromatography (LC) with column switching and tandem mass spectrometric (MS/MS) detection is described. After protein precipitation with methanol, diluted extracts were injected on to a small LC column (10 x 3.0 mm i.d.) for on-line concentration and further clean-up of the sample. Next, the analyte and deuterated internal standard were back-flushed on to an analytical column for separation and subsequent detection in an API 2000 triple-quadrupole mass spectrometer. The lower limit of quantitation was 0.05 ng mL(-1) using 100 micro l of plasma with a linear dynamic range up to 2.5 ng ml(-1). Validation of the method was performed according to the most recent FDA guidelines for bioanalytical method validation. The time needed for off-line sample preparation has been reduced 10-fold compared with an existing LC/MS/MS method for ET-743 in human plasma, employing a labor-intensive solid-phase extraction procedure for sample pretreatment. The proposed column switching method was successfully applied in phase II clinical trials with Yondelis and pharmacokinetic monitoring.  相似文献   