首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
This study describes the development of an analytical methodology based on the use of microchip electrophoresis (ME) devices integrated with capacitively coupled contactless conductivity detection (C4D) for the separation and detection of inorganic anions in post‐blast explosive residues. The best separation condition was achieved using a running buffer composed of 35 mmol/L lactic acid, 10 mmol/L histidine and 0.070 mmol/L cetyl(trimethyl ammonium) bromide. For C4D measurements, the highest sensitivity was obtained applying a 700 kHz sinusoidal wave with excitation voltage of 20 Vpp. The separation of Cl?, NO3?, NO2?, SO42?, ClO4? and ClO3? was performed within ca. 150 s with baseline resolution and efficiencies between 4.4 × 104 and 1.7 × 105 plates/m. The found limits of detection ranged between 2.5 and 9.5 μmol/L. Last, real samples of post‐blast explosive residues were analyzed on the ME‐C4D devices obtaining successfully the determination of Cl?, NO3? and SO42?. The achieved concentration values varied between 12.8–72.5 mg/L for Cl?, 1.7–293.1 mg/L for NO3? and 1.3–201.3 mg/L for SO42?. The data obtained using ME‐C4D devices were in good agreement with the concentrations found by ion chromatography. The approach reported herein has provided short analysis time, instrumental simplicity, good analytical performance and low cost. Furthermore, the ME‐C4D devices emerge as a powerful and portable analytical platform for on‐site analysis demonstrating to be a promising tool for the crime scene investigation.  相似文献   

2.
The aim of the current study was to optimise and validate the methodology for determination of γ‐hydroxybutyric acid (GHB) in saliva by CE combined with a contactless conductivity detector (C4D) and indirect UV absorbance detection (λABS = 210 nm). The optimized BGE, consisting of 8.5 mM maleic acid, 17 mM arginine, 255 μM cetyltrimethylammonium bromide (CTAB), and 15% acetonitrile, was evaluated for the separation of GHB in saliva within 6 min. The performance characteristics of the CE‐C4D‐indirect UV methodology was validated. The instrument detection and quantification limits were 0.49 and 1.6 mg/L for C4D, and 5.1 mg/L and 17.0 mg/L for indirect UV, respectively. The linearity was obtained over the range from 2.5 to 400 mg/L for C4D and from 12.5 to 400 mg/L for indirect UV. The interday precisions were within 2.3–5.7% and intraday precisions were within 1.6–9.0% for C4D as well as 2.1–9.3%, 5.6–10.1% for indirect UV in spiked saliva, respectively. The recoveries were within 87.2–104.4%. The matrix effects were +53.2% for small concentrations up to 25 mg/L for C4D and +23.6% for concentrations up to 75 for mg/L for indirect UV detection. No matrix effects were observed for higher concentration levels. In conclusion, CE‐C4D‐indirect UV can offer a rapid, accurate, sensitive, and definitive method for the determination of GHB abuse in saliva samples as a forensic screening tool.  相似文献   

3.
This study reports the separation of fructose, galactose, glucose, lactose and sucrose on glass microchip electrophoresis (ME) devices using a microfluidic platform adapted with external reservoirs for controlling the electrolysis phenomenon. The connections between external reservoirs and microfluidic platform were performed by saline bridges created using silicone tubing filled with BGE. The separation conditions were optimized and the best results were achieved using a BGE containing 75 mmol/L NaOH and 15 mmol/L trisodium phosphate. Electrophoretic separations were monitored using a capacitively coupled contactless conductivity detection system. The controlled electrolysis has successfully allowed the application of a higher voltage on the separation channel promoting the baseline separation of five carbohydrates within 180 s with great run‐to‐run repeatability (RSD < 1%). The achieved efficiencies ranged from 45 000 ± 6000 to 70 000 ± 3000 plates/m demonstrating a performance better than ME devices without controlled electrolysis. The proposed system offered good linearity from 1 to 10 mmol/L and LODs between 150 and 740 μmol/L. The use of external tubes for controlling the electrolysis phenomenon on ME devices has solved common problems associated to run‐to‐run repeatability and analytical reliability required for routine and quantitative analysis.  相似文献   

4.
A method for sensitive determination of five priority haloacetic acids in drinking water has been developed for the first time based on electromembrane extraction (EME) prior to CZE with capacitively coupled contactless conductivity detection (CZE‐C4D). The target analytes were extracted from 10 mL of the sample solution (donor phase), through the supported liquid membrane (using a polypropylene membrane supporting 1‐octanol), and into 10 µL of 50 mmol/L NaAc solution (acceptor phase). The extracted solution was directly analyzed by CZE‐C4D without derivatization. Several factors that affect separation, detection and extraction efficiency were investigated. Under the optimum conditions, five haloacetic acids (monochloroacetic acid, dichloroacetic acid, trichloroacetic acid, monobromoacetic acid, and dibromoacetic acid) could be well separated from other components coexisting in water samples within 23 min, exhibiting a linear calibration over two orders of magnitude (r?0.9943); the enrichment factors at 430–671 were obtained in a 30 min of extraction, and the limits of detection were in the range of 0.17–0.61 ng/mL. The intraday relative standard deviations for peak areas investigated at 10 ng/mL were between 1.2% and 9.7% for the combined EME‐CZE‐C4D procedure. This approach offers an attractive alternative to the officially proposed method for purified drinking water analysis, which requires derivatization procedure prior to gas chromatography analysis.  相似文献   

5.
A novel method for the determination of ephedra alkaloids (methylephedrine and pseudoephedrine) was developed by electrophoresis capillary (CE) separation and electrochemiluminesence detection (ECL). The use of ionic liquid (1‐butyl‐3‐methylimidazolium tetrafluoroborate, BMIMBF4) improved the detection sensitivity markedly. The conditions for CE separation, ECL detection and effect of ionic liquid were investigated in detail. The two ephedra alkaloids with very similar structures were well separated and detected under the optimum conditions. The limits of detection (signal‐to‐noise ratio = 3) in standard solution were 1.8 × 10–8 mol/L for methylephedrine (ME) and 9.2 × 10–9 mol/L for pseudoephedrine (PSE). The limits of quantitation (signal‐to‐noise ratio = 10) in human urine samples were 2.6 × 10?7 mol/L for ME and 3.6 × 10–7 mol/L for PSE. The recoveries of two alkaloids at three different concentration levels in human urine samples were between 81.7 and 105.0%. The proposed method was successfully applied to the determination of ME and PSE in human urine and the monitoring of pharmacokinetics for PSE. The proposed method has potential in therapeutic drug monitoring and clinical analysis. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

6.
Increasing evidence has demonstrated that multidrug combinations could amplify the therapeutic efficacies of each agent. Interestingly, the pharmacological effect of traditional Chinese medicine (TCM) is usually attributed to the drug‐interaction property (synergism) of multiple active constituents. Pharmacokinetics is a useful means of evaluating the drug interactions of major active compounds in TCM. A simple, sensitive and reliable RP‐HPLC‐DAD method has been developed to simultaneously quantify 6,7‐dimethylesculetin (D), geniposide (G) and rhein (R), which are the active ingredients in Yin–Chen–Hao–Tang (YCHT), performing drug‐interaction pharmacokinetics studies in vivo. Plasma samples were prepared using methanolic precipitation, a filtration step, and then injection of the methanolic extract onto a Nova‐Pak C18 Guard‐Pak? guard column with a gradient mobile phase. Triple‐wavelength diode array detection was set at λmax values of 343 nm for D, 241 nm for the G, and 259 nm for R. Our results successfully demonstrate that this method has excellent and satisfactory selectivity, sensitivity, linearity, precision, accuracy and recovery. In healthy rats, the estimated pharmacokinetic parameters (i.e. Cmax, AUC and Cl) of D, G and R, when administered with COC (a combination of D, G and R), were Cmax 16.05 mg/L, AUC 108.96 mg h/L and Cl 0.36 L/h for D; Cmax 9.35 mg/L, AUC 64.71 mg h/L and Cl 0.88 L/h for G; and Cmax 14.18 mg/L, AUC 57.98 mg h/L and Cl 1.77 L/h for R. Here, we report that the COC combination could significantly increase the plasma level and slow the elimination rate compared with any one or two of the three individual compounds, which may indicate a drug–drug interaction. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

7.
Electromembrane extraction (EME) and CE with capacitively coupled contactless conductivity detection (CE‐C4D) was applied to rapid and sensitive determination of perchlorate in drinking water and environmental samples. Porous polypropylene hollow fiber impregnated with 1‐heptanol acted as a supported liquid membrane (SLM) and perchlorate was transported and preconcentrated in the fiber lumen on application of electric field. High selectivity of perchlorate determination and its baseline separation from major inorganic anions was achieved in CE‐C4D using background electrolyte solution consisting of 7.5 mM L ‐histidine and 40 mM acetic acid at pH 4.1. The analytical method showed excellent parameters in terms of reproducibility; RSD values for migration times and peak areas at a spiked concentration of 15 μg/L of perchlorate (US EPA recommended limit for drinking water) were below 0.2 and 8.7%, respectively, in all examined water samples. Linear calibration curves were obtained for perchlorate in the concentration range 1–100 μg/L (r2≥0.999) with limits of detection at 1 μg/L for tap water and at 0.25–0.35 μg/L for environmental and bottled potable water samples. Recoveries at 15 μg/L of perchlorate were between 95.9 and 106.7% with minimum and maximum recovery values for snow and bottled potable water samples, respectively.  相似文献   

8.
In this work, a method for simultaneous determination of amfepramone, fenproporex, sibutramine and fluoxetine was developed by capillary zone electrophoresis with capacitively coupled contactless conductivity detection (C4D) using a homemade capillary electrophoretic system. The optimized conditions for the separation of the pharmaceuticals by CZE were as follows: 50 mmol L− 1 phosphate buffer (pH 5.0) in 50/50 (v/v) mixture of water/acetonitrile as the working electrolyte, 15 kV separation voltage, 25 °C separation temperature, hydrodynamic injection by gravity using 20 cm injection height and 60 s injection time. The detection by C4D was carried out by using a homemade detector, which employs a sinusoidal wave generator operating at 600 kHz frequency and 2 Vpp wave amplitude. The optimized and validated CZE-C4D method was applied for the determination of the studied pharmaceuticals as adulterants in phytotherapeutic formulations commercialized in Brazil for slimming purposes.  相似文献   

9.
Paralytic shellfish toxins (PSTs) are produced by marine and freshwater microalgae and accumulate in shellfish including mussels, oysters, and scallops, causing possible fatalities when inadvertently consumed. Monitoring of PST content of shellfish is therefore important for food safety, with currently approved methods based on HPLC, using pre‐ or postcolumn oxidation for fluorescence detection (HPLC‐FLD). CE is an attractive alternative for screening and detection of PSTs as it is compatible with miniaturization and could be implemented in portable instrumentation for on‐site monitoring. In this study, CE methods were developed for C4D, FLD, UV absorption detection, and MS—making this first report of C4D and FLD for PSTs detection. Because most oxidized toxins are neutral, MEKC was used in combination with FLD. The developed CZE‐UV and CZE‐C4D methods provide better resolution, selectivity, and separation efficiency compared to CZE‐MS and MEKC‐FLD. The sensitivity of the CZE‐C4D and MEKC‐FLD methods was superior to UV and MS, with LOD values ranging from 140 to 715 ng/mL for CZE‐C4D and 60.9 to 104 ng/mL for MEKC‐FLD. With the regulatory limit for shellfish samples of 800 ng/mL, the CZE‐C4D and MEKC‐FLD methods were evaluated for the screening and detection of PSTs in shellfish samples. While the CZE‐C4D method suffered from significant interferences from the shellfish matrix, MEKC‐FLD was successfully used for PST screening of a periodate‐oxidized mussel sample, with results confirmed by HPLC‐FLD. This confirms the potential of MEKC‐FLD for screening of PSTs in shellfish samples.  相似文献   

10.
Capillary zone electrophoresis coupled with a capacitively coupled contactless conductivity detector (CE‐C4D) has been employed for the determination of atenolol and amiloride in pharmaceutical formulations. Acetic acid (150 mm ) was used as background electrolyte. The influence of several factors (detector excitation voltage and frequency, buffer concentration, applied voltage, capillary temperature and injection time) was studied. Non‐UV‐absorbing L‐valine was used as internal standard; the analytes were all separated in less than 7 min. The separation was carried out in normal polarity mode at 28°C, 25 kV and using hydrodynamic injection (25 s). The separation was effected in an uncoated fused‐silica capillary (75 μm, i.d. × 52 cm). The CE‐C4D method was validated with respect to linearity, limit of detection and quantification, accuracy, precision and selectivity. Calibration curves were linear over the range 5–250 μg/mL for the studied analytes. The relative standard deviations of intra‐ and inter‐day migration times and corrected peak areas were less than 6.0%. The method showed good precision and accuracy and was successfully applied to the simultaneous determination of atenolol and amiloride in different pharmaceutical tablet formulations. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

11.
A simple and reliable method was established for simultaneous determination of 4‐hydroxyphenyl acetic acid, 4‐hydroxyphenyl lactic acid, and 3,4‐hydroxyphenyl propionic acid in human urine by high‐performance liquid chromatography with fluorescence detection. Solid‐phase extraction was used to eliminate the interferences in urine. The separation of three analytes was achieved using a C18 column and a mobile phase formed by a 95:5 v/v mixture of 50 mmol/L ammonium acetate buffer at pH 6.8 that contained 5 mmol/L tetrabutyl ammonium bromide and acetonitrile. Under the optimized conditions, the detection limits of 4‐hydroxyphenyl acetic acid, 4‐hydroxyphenyl lactic acid, and 3,4‐hydroxyphenyl propionic acid were 4.8 × 10−3, 8.80 × 10−3, and 9.00 × 10−3 mg/L, respectively, and the recoveries were in the range of 85.0–120.0% with relative standard deviations of 1.5–3.1%. This method was used to analyze urine samples from breast cancer patients, healthy people and post‐surgery breast cancer patients. Significant differences in urinary levels of 4‐hydroxyphenyl acetic acid and 4‐hydroxyphenyl lactic acid could be found between the breast cancer patients group and other two groups. No effect of age and sex was observed on the urinary levels of 4‐hydroxyphenyl acetic acid and 4‐hydroxyphenyl lactic acid. This method might be helpful for cancer biomarkers discovery in urine.  相似文献   

12.
A novel method has been developed for simultaneous determination of eight typical biogenic amines (BAs) based on CZE with capacitively coupled contactless conductivity detection (CZE–C4D). On-column C4D was used for direct quantification of these nonUV-absorbing amine compounds without derivatization. The effects of various experimental factors on separation and detection were investigated. Under the optimum conditions, spermine, spermidine, histamine, putrescine, cadaver, β-phenylethylamine, tyramine, and tryptamine can be well separated within 24 min at the separation voltage of 16 kV in 150 mmol L?1 18-crown-6/500 mmol L?1 acetic acid running buffer, and the excitation voltage and frequency of C4D were 60 V and 550 kHz, respectively. A good linear relationship could be obtained between the peak area and the concentration of each BA at three orders of magnitude; the limits of detection were in the range of 44.3–149 ng mL?1. This proposed method has been successfully applied for the analysis of BAs in water and hard liquor samples.  相似文献   

13.
We report fast, precise, selective, and sensitive electroanalytical methods for the determination of ciprofloxacin in milk and pharmaceutical samples by batch‐injection analysis with amperometric detection (BIA‐AMP) and by capillary electrophoresis with capacitively‐coupled contactless conductivity detection (CE‐C4D). Both methods required simple sample preparation protocols before analysis (milk samples were just diluted and tablets powdered and dissolved in electrolyte/water). The analytical features of BIA‐AMP and CE‐C4D methods include, respectively, low relative standard deviation values for repetitive measurements (2.8 % and 1.7 %, n=10), low detection limits (0.3 and 5.0 µmol L?1), elevated analytical frequency (80 and 120 h?1) and satisfactory accuracy (based on comparative determinations by HPLC and recovery values for spiked samples).  相似文献   

14.
CE methods with capacitively coupled contactless conductivity detection (C4D) were developed for the enantiomeric separation of the following stimulants: amphetamine (AP), methamphetamine (MA), ephedrine (EP), pseudoephedrine (PE), norephedrine (NE) and norpseudoephedrine (NPE). Acetic acid (pH 2.5 and 2.8) was found to be the optimal background electrolyte for the CE‐C4D system. The chiral selectors, carboxymethyl‐β‐cyclodextrin (CMBCD), heptakis(2,6‐di‐O‐methyl)‐β‐cyclodextrin (DMBCD) and chiral crown ether (+)‐(18‐crown‐6)‐2,3,11,12‐tetracarboxylic acid (18C6H4), were investigated for their enantioseparation properties in the BGE. The use of either a single or a combination of two chiral selectors was chosen to obtain optimal condition of enantiomeric selectivity. Enantiomeric separation of AP and MA was achieved using the single chiral selector CMBCD and (hydroxypropyl)methyl cellulose (HPMC) as the modifier. A combination of the two chiral selectors, CMBCD and DMBCD and HPMC as the modifier, was required for enantiomeric separation of EP and PE. In addition, a combination of DMBCD and 18C6H4 was successfully applied for the enantiomeric separation of NE and NPE. The detection limits of the enantiomers were found to be in the range of 2.3–5.7 μmol/L. Good precisions of migration time and peak area were obtained. The developed CE‐C4D method was successfully applied to urine samples of athletes for the identification of enantiomers of the detected stimulants.  相似文献   

15.
Electrochemical techniques are commonly applied to micro total analysis system (μTAS) devices mainly due to its high sensitivity and miniaturization capacity. Among many electrochemical techniques, capacitively coupled contactless conductivity detection (C4D) stands out for not requiring direct electrode-solution contact, avoiding several problems such as electrolysis, bubble formation, and metal degradation. Furthermore, the instrumentation required for C4D measurements is compact, low cost, and easy to use, allowing in situ measurements to be performed even by nonspecialized personal. Contrarily, the production of metallic electrodes and microchannels adequate for C4D measurements commonly requires specialized facilities and workers, increasing the costs of applying these methods. We propose alternatives to batch manufacture metallic electrodes and polymeric microchannels for C4D analysis using more straightforward equipment and lower-cost materials. Three devices with different dielectric layer compositions and electrode sizes were tested and compared regarding their analytical performance. The constructed platforms have shown a reduction of more than 64% in cost when compared to traditional techniques and displayed good linearity (R2 ≥ 0.994), reproducibility (RSD ≤ 4.07%, n = 3), and limits of detection (≤0.26 mmol/L) when measuring standard NaCl samples. Therefore, the proposed methods were successfully validated and are available for further C4D applications such as diagnosis of dry-eye syndrome.  相似文献   

16.
Levamisole is the most common adulterant found in cocaine samples and its electrochemical determination in cocaine seized samples is a challenge due to peak overlapping with cocaine. Herein, we propose a deconvolution procedure for levamisole determination in seized cocaine samples using screen‐printed carbon electrodes (SPE). Square‐wave voltammetry in 0.04 mol L?1 Britton Robinson buffered solution (pH 8.0) was selected in combination with optimized SWV parameters (f=8 s?1, a=10 mV and ΔEs=1 mV) to result in the best peak resolution to apply the deconvolution procedure. Deconvoluted responses of levamisole in the presence of cocaine were similar to untreated signals of standard levamisole solutions in absence of cocaine. A linear response was obtained in the range of 20–100 μmol L?1 (r=0.995). The results obtained for the analysis of a seized cocaine sample was statistically similar to that obtained by gas chromatography. Other adulterants found in cocaine street samples (paracetamol, glucose, phenacetin, caffeine, boric acid and lidocaine) did not affect the treated of voltammetric responses of levamisole. A pharmaceutical sample containing levamisole was also analyzed on SPEs and a recovery of 93±2 % was obtained (no deconvolution required for this sample), showing great applicability of SPEs for forensic and pharmaceutical analyses.  相似文献   

17.
《Electrophoresis》2017,38(7):1068-1074
In this work, the use of a novel derivatization agent for the determination of aldehydes (in this particular case: formaldehyde, acetaldehyde, propionaldehyde, and valeraldehyde) using micellar electrokinetic chromatography is reported. The derivatization reaction is based on the reaction of aldehydes with benzhydrazide to form the corresponding derivates with maximum absorbance at 250 nm. The experimental conditions of the derivatization reaction as well of the separation were optimized. The adducts were separated with a +22 kV voltage at a temperature of 29°C. The adducts’ separation was performed in less than 14 min using as the running buffer a mixture containing 110 mmol/L of sodium dodecyl sulfate and 27 mmol/L of sodium tetraborate at pH 9.45. Samples were injected using hydrodynamic mode (50 mbar × 5 s). The calibration curves were linear up to 15.0 mg/L with r 2 above 0.99. Intra and inter‐day precisions were in average 3 and 4%, respectively, and recoveries were in average of 95%. Limits of detection and quantification were around 0.5 and 1.5 mg/L, respectively. The developed method was successfully applied in the analysis of low molar weight aldehydes in yogurt and vinegar samples.  相似文献   

18.
A method for the determination of ethambutol (EMB), a first‐line drug against tuberculosis, based on CE with capacitively coupled contactless conductivity detection is proposed. The separation of EMB and its main product of degradation were achieved in less than 3 min with a resolution of 2.0 using a BGE composed of 50 mmol/L histidine and 30 mmol/L MES, pH 6.30. By raising the pH to 8.03, the analysis time was reduced to 1.0 min, but with a significant loss of resolution (0.7). Using the best separation conditions, linearity of 0.9976 (R2, five data points), sensitivity of 1.26×10?4 V min μmol?1 L, and LOD and quantification of 23.5 and 78.3 μmol/L, respectively, were obtained. Recoveries at four levels of concentration ranged from 95 to 102% and the concentration range studied ranged from 100 to 500 μmol/L. The results obtained for the determination of EMB in pharmaceutical formulations were compared with those obtained by using CE with photometric detection.  相似文献   

19.
《Electrophoresis》2018,39(14):1802-1807
An improved method for the concurrent determination and separation of cations and anions by microchip electrophoresis with capacitively coupled contactless conductivity detection (ME‐C4D) is described. Two kinds of microchip structures were designed. The first microchip has a long bent separation channel. And for the defects of the first microchip, the second microchip with a Y‐type separation channel has been proposed. The background electrolyte (BGE) composed of 20 mm His/MES and 0.01 mm CTAB was optimized for inhibiting the electroosmotic flow (EOF). Due to the low electroosmotic flow, the cations and anions migrate in opposite directions and can be separated from each other. With the precisely controlled high‐voltage, cations and anions can be migrated in microchannels according to our requirements and sequentially detected by a C4D detector built in‐house. Samples containing K+, Na+, Li+, Cl, F and PO43− were analyzed simultaneously in a single run (within 140 s) by both methods. The reproducibility obtained by both methods remained below 5% for migration time and within 3.5–9.1% for peak areas. The proposed concurrent determination methods are inexpensive, simple, fast, ease of operation, high degree of integration.  相似文献   

20.
A fast, selective and sensitive ultraperformance liquid chromatography–tandem mass spectrometry method was developed for determination and pharmacokinetic study of anastrozole in human plasma. Plasma sample pretreatment involved a one‐step extraction with diethyl ether of 500 µL plasma. The chromatographic separation was carried out on an Acquity UPLCTM BEH C18 column with a mobile phase consisting of methanol–10 mmol/L ammonium acetate (75:25, v/v) at a flow rate of 0.30 mL/min. The detection was performed on a triple quadrupole tandem mass spectrometer by multiple reaction monitoring via electrospray ionization source with positive mode. A high throughput was achieved with a run time of 1.5 min per sample. The standard curve for anastrozole was linear (r2 ≥ 0.99) over the concentration range of 0.0550–27.5 ng/mL with a lower limit of quantification of 0.0550 ng/mL. The intra‐ and inter‐day precision (relative standard deviation) values were not higher than 14% and the accuracy (relative error) was within ±3.2% at three quality control levels. This simple, fast and highly sensitive method was fully validated and successfully applied to a clinical pharmacokinetic study of anastrozole in healthy volunteers after oral administration. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏