共查询到20条相似文献,搜索用时 15 毫秒
1.
《Biomedical chromatography : BMC》2018,32(8)
A highly sensitive, selective and rugged method has been described for the quantification of metronidazole (MTZ) in human plasma by liquid chromatography–tandem mass spectrometry using metronidazole‐d4 as the internal standard (IS). The analyte and the IS were extracted from 100 μL plasma by liquid–liquid extraction. The clear samples obtained were chromatographed on an ACE C18 (100 × 4.6 mm, 5 μm) column using acetonitrile and 10.0 mm ammonium formate in water, pH 4.00 (80:20, v/v) as the mobile phase. A triple quadrupole mass spectrometer system equipped with turbo ion spray source and operated in multiple reaction monitoring mode was used for the detection and quantification of MTZ. The calibration range was established from 0.01 to 10.0 μg/mL. The results of validation testing for precision and accuracy, selectivity, matrix effects, recovery and stability complied with current bioanalytical guidelines. A run time of 3.0 min permitted analysis of more than 300 samples in a day. The method was applied to a bioequivalence study with 250 mg MTZ tablet formulation in 24 healthy Indian males. 相似文献
2.
Xianqin Wang Zheng Xiang Xiaojun Cai Haiya Wu Xuebao Wang Junwei Li Meiling Zhang 《Biomedical chromatography : BMC》2011,25(7):833-837
A sensitive and selective liquid chromatography–tandem mass spectrometry method for the determination of pethidine in human plasma was developed and validated over the concentration range of 4–2000 ng/mL. After addition of ketamine as internal standard, liquid–liquid extraction was used to produce a protein‐free extract. Chromatographic separation was achieved on a 100 × 2.1 mm, 5 µm particle, AllureTM PFP propyl column, with 45:40:15 (v/v/v) acetonitrile–methanol–water containing 0.2% formic acid as mobile phase. The MS data acquisition was accomplished by multiple reactions monitoring mode with positive electrospray ionization interface. The lower limit of quantification was 4 ng/mL; for inter‐day and intra‐day tests, the precision (RSD) for the entire validation was less than 7%, and the accuracy was within 95.9–106.5%. The method is sensitive and simple, and was successfully applied to analysis of samples of clinical intoxication. Copyright © 2010 John Wiley & Sons, Ltd. 相似文献
3.
4.
High‐pH or basic/alkaline mobile phases are not commonly used in LC–MS or LC–MS/MS bioanalysis because of the deeply rooted concern with column instability and reduced detection sensitivity for basic compounds in high‐pH mobile phases owing to charge neutralization. With the advancement of LC column technology and the wide recognition of the “wrong‐way‐round” phenomena, high‐pH mobile phases are more and more used in LC–MS or LC–MS/MS bioanalysis to improve chromatographic peak shape, retention, selectivity, resolution, and detection sensitivity, not only for basic compounds, but also for many other compounds. In this article, the benefits, practical considerations, application examples and cautions for using high‐pH mobile phases in LC–MS or LC–MS/MS bioanalysis are reviewed, with a focus on quantification. Furthermore, the future trends in this field are also envisaged. A total of 84 references are cited in this review. 相似文献
5.
《Biomedical chromatography : BMC》2018,32(9)
A rapid, sensitive and reproducible LC–MS/MS method was developed and validated to determine iguratimod in human plasma. Sample preparation was achieved by protein precipitation with acetonitrile. Chromatographic separation was operated on an Ultimate® XB‐C18 column (2.1 × 50 mm, 3.5 μm, Welch) with a flow rate of 0.400 mL/min, using a gradient elution with acetonitrile and water which contained 2 mm ammonium acetate and 0.1% formic acid as the mobile phase. The detection was performed on a Triple Quad™ 5500 mass spectrometer coupled with an electrospray ionization interface under positive‐ion multiple reaction monitoring mode with the transition ion pairs of m/z 375.2 → 347.1 for iguratimod and m/z 244.3 → 185.0 for agomelatine (the internal standard), respectively. The method was linear over the range of 5.00–1500 ng/mL with correlation coefficients ≥0.9978. The accuracy and precision of intra‐ and inter‐day, dilution accuracy, recovery and stability of the method were all within the acceptable limits and no matrix effect or carryover was observed. As a result, the main pharmacokinetic parameters of iguratimod were as follows: Cmax, 1074 ± 373 ng/mL; AUC0–72, 13591 ± 4557 ng h/mL; AUC0–∞, 13,712 ± 4613 ng h/mL; Tmax, 3.29 ± 1.23 h; and t1/2, 8.89 ± 1.23 h. 相似文献
6.
Yashpal S. Chhonker Richard L. Sleightholm Daryl J. Murry 《Biomedical chromatography : BMC》2019,33(2)
Moxidectin (MOX) has recently been approved by the US Food and Drug Administration for the treatment of river blindness in select populations. It is also being evaluated as an alternative for the use of ivermectin, widespread resistance to which is becoming a global health issue. Moreover, MOX is becoming increasingly used as a prophylactic antiparasitic in the cattle industry. In this study, we developed and validated an LC–MS/MS method of MOX in human, monkey and mouse plasma. The separation was achieved on an ACE C18 (50 × 3.0 mm, 3 μm) column with isocratic elution using 0.1% acetic acid and methanol–acetonitrile (1:1, v/v) as mobile phase. MOX was quantitated using MS/MS with an electrospray ionization source operating in negative multiple reaction monitoring mode. The multiple reaction monitoring precursor ion → product ion transitions for MOX and abamectin (IS) were m/z 638.40 → 236.30 and m/z 871.50 → 565.35 respectively. The MS/MS response was linear over the concentration range 0.1–1000 ng/mL in plasma with a correlation coefficient (r2) of 0.997 or better. The within‐ and between‐day precision (relative standard deviation, RSD) and accuracy were within the acceptable limits per US Food and Drug Administration guidelines. The method was successfully applied to an in vitro metabolic stability study of MOX. 相似文献
7.
《Biomedical chromatography : BMC》2017,31(2)
A reliable, high‐throughput and sensitive LC–MS/MS procedure was developed and validated for the determination of five tyrosine kinase inhibitors in human plasma. Following their extraction from human plasma, samples were eluted on a RP Luna®‐PFP 100 Å column using a mobile phase system composed of acetonitrile and 0.01 m ammonium formate in water (pH ~4.1) with a ratio of (50:50, v /v) flowing at 0.3 mL min−1. The mass spectrometer was operating with electrospray ionization in the positive ion multiple reaction monitoring mode. The proposed methodology resulted in linear calibration plots with correlation coefficients values of r 2 = 0.9995–0.9999 from concentration ranges of 2.5–100 ng mL−1 for imatinib, 5.0–100 ng mL−1 for sorafenib, tofacitinib and afatinib, and 1.0–100 ng mL−1 for cabozantinib. The procedure was validated in terms of its specificity, limit of detection (0.32–1.71 ng mL−1), lower limit of quantification (0.97–5.07 ng mL−1), intra‐ and inter assay accuracy (−3.83 to +2.40%) and precision (<3.37%), matrix effect and recovery and stability. Our results demonstrated that the proposed method is highly reliable for routine quantification of the investigated tyrosine kinase inhibitors in human plasma and can be efficiently applied in the rapid and sensitive analysis of their clinical samples. 相似文献
8.
《Biomedical chromatography : BMC》2017,31(3)
The endogenous deoxynucleoside triphosphate (dNTP) pool includes deoxyadenosine triphosphate (dATP), deoxycytidine triphosphate (dCTP), deoxyguanosine triphosphate (dGTP) and thymidine triphosphate (TTP). The endogenous dNTP pool is regulated by complex enzymatic pathways that can be targeted by drugs, such as antimetabolites. In addition, these components compete with antiviral nucleos(t)ide analog triphosphates, contributing to the mechanism of pharmacologic action. This communication describes the development and validation of a sensitive method to quantify the intracellular dNTP pool in cellular lysates. The extraction process was optimized for dNTPs using an indirect strategy – the separation of mono‐, di‐ and triphosphate moieties by strong anion exchange, dephosphorylation of target fractions to molar equivalent nucleosides – followed by sensitive quantitation using liquid chromatography–tandem mass spectrometry. The validated analytical range was 50–2500 fmol/sample for each dNTP. The assay was used to quantify dNTPs in peripheral blood mononuclear cells from 40 clinical research participants (n = 279 samples). Median (interquartile range) concentrations were 143 (116, 169) for dATP, 737 (605, 887) for dCTP, 237 (200, 290) for dGTP and 315 (220, 456) for TTP, in femtomoles per million cells. This method allows for future studies of endogenous dNTP disposition in subjects receiving antimetabolites or nucleos(t)ide analogs, or for other clinical scenarios. 相似文献
9.
Tai Rao Yu‐Feng Gong Jing‐Bo Peng Yi‐Cheng Wang Kang He Hong‐Hao Zhou Zhi‐Rong Tan Li‐Zhi Lv 《Biomedical chromatography : BMC》2019,33(9)
Astragali Radix (AR) is a widely used traditional Chinese medicine for healing the cardiovascular, liver and immune systems. Recently, superfine pulverizing technology has been applied to developing novel formulations to improve bioavailability of the active constituents in herbs, such as ultrafine granular powder of AR. In this study, a universal and sensitive quantitative method based on LC–MS/MS was employed for determining formononetin, the main flavonoid in AR, in human plasma for comparative pharmacokinetics of three oral formulations of AR. Formononetin and IS (quercetin) were extracted by ethyl acetate from human plasma and were separated on a C18 column with a mobile phase consisting of acetonitrile and 0.1% formic acid. Positive‐ion electrospray‐ionization mode was applied in mass spectrometric detection. The quantitative method was validated with regards to selectivity, linearity, accuracy and precision, matrix effect, extraction recovery and stability, and was applied to comparing the pharmacokinetics of ultrafine granular powder (UGP), ultrafine powder (UP) and traditional decoction pieces (TDP) of AR after oral administration. The peak concentration and areas under the concentration–time curve of formononetin in UGP and UP were significantly higher than those of TDP. UGP and UP could significantly improve the bioavailability of AR in human compared with TDP after oral administration. 相似文献
10.
An LC–MS/MS‐based bioanalytical method has been developed to measure the concentration of L‐threonate at its endogenous level in human plasma. Following isotope dilution and protein precipitation, the samples were acetylated and chromatographed under reversed‐phase conditions for baseline separation of the derivatized L‐threonate and its stereoisomer D‐erythronate. The method was assessed by a fit‐for‐purpose validation with a calibration range from 100 to 10,000 ng/mL. The intra‐run coefficients of variation (CVs) were <3.6% and the inter‐run CV was 3.2% for the QC samples at endogenous level. At the lower limit of quantitation, the intra‐run CV was 6.1% and the average inaccuracy was ?1.4%. This method provides an efficient and reliable quantitation of L‐threonate and could be useful to certain biomarker investigators. 相似文献
11.
《Biomedical chromatography : BMC》2017,31(12)
A sensitive LC–MS method was developed for the quantification of morusin in rat plasma using praeruptorin C as internal standard. After extraction with diethyl ether, post‐treatment samples were chromatographed on a Hypersil C18 column. An isocratic mobile phase consisting of methanol–water (70:30, v /v) was applied at a flow rate of 0.4 mL/min. Detection was performed via electrospray ionization source with positive ion mode using selected ion monitoring mode at m/z 443.1 for morusin and m/z 451.0 for IS. Acceptable linearity (r 2 ≥ 0.99) was observed over the concentration range of 1.5–800 ng/mL. This method was successfully applied in the pharmacokinetics study of morusin in rats. 相似文献
12.
《Biomedical chromatography : BMC》2017,31(12)
A sensitive and specific LC–MS/MS assay for determination of β ‐eudesmol in rat plasma was developed and validated. After liquid–liquid extraction with ethyl ether , the analyte and IS were separated on a Capcell Pak C18 column (50 × 2.0 mm, 5 μm) by isocratic elution with acetonitrile—water–formic acid (77.5:22.5:0.1, v /v/v) as the mobile phase at a flow rate of 0.4 mL/min. An ESI source was applied and operated in positive ion mode; a selected reaction monitoring scan was used for quantification by monitoring the precursor–product ion transitions of m/z 245.1 → 163.1 for β ‐eudesmol and m/z 273.4 → 81.2 for IS. Good linearity was observed in the concentration range of 3–900 ng/mL for β ‐eudesmol in rat plasma. Intra‐ and inter‐day precision and accuracy were both within ±14.3%. This method was applied for pharmacokinetic studies after intravenous bolus of 2.0 mg/kg or intragastric administration of 50 mg/kg β ‐eudesmol in rats. 相似文献
13.
《Biomedical chromatography : BMC》2018,32(2)
A sensitive and selective liquid chromatography–tandem mass spectrometry (LC–MS/MS) method is described for the simultaneous determination of silodosin (SLD) and its active metabolite silodosin β‐d ‐glucuronide (KMD‐3213G) in human plasma. Liquid–liquid extraction of plasma samples was carried out with ethyl acetate and methyl tert‐butyl ether solvent mixture using deuterated analogs as internal standards. The extraction recoveries of SLD and KMD‐3213G were in the ranges 90.8–93.4 and 87.6–89.9%, respectively. The extracts were analyzed on a Symmetry C18 (50 × 4.6 mm, 5 μm) column under gradient conditions using 10 mm ammonium formate in water and methanol–acetonitrile (40:60, v/v), within 6.0 min. For MS/MS measurements, ionization of the analytes was carried out in the positive ionization mode and the transitions monitored were m/z 496.1 → 261.2 for SLD and m/z 670.2 → 494.1 for KMD‐3213G. The method showed good linearity, accuracy, precision and stability in the range 0.10–80.0 ng/mL for SLD and KMD‐3213G. The IS‐normalized matrix factors obtained were highly consistent, ranging from 0.962 to 1.023 for both analytes. The method was used to support a bioequivalence study of SLD and its metabolite in healthy volunteers after oral administration of 8 mg silodosin capsules. 相似文献
14.
Abhaysingh Bhadoriya Priyanka A. Shah Pranav S. Shrivastav Mallika Sanyal Manish S. Yadav 《Biomedical chromatography : BMC》2019,33(9)
A high‐throughput and sensitive liquid chromatography–tandem mass spectrometry (LC–MS/MS) method has been developed and validated for the determination of flunarizine in human plasma. Liquid–liquid extraction under acidic conditions was used to extract flunarizine and flunarizine‐d8 from 100 μL human plasma. The mean extraction recovery obtained for flunarizine was 98.85% without compromising the sensitivity of the method. The chromatographic separation was performed on Hypersil Gold C18 (50 × 2.1 mm, 3 μm) column using methanol–10 mm ammonium formate, pH 3.0 (90:10, v/v) as the mobile phase. A tandem mass spectrometer (API‐5500) equipped with an electrospray ionization source in the positive ion mode was used for detection of flunarizine. Multiple reaction monitoring was selected for quantitation using the transitions, m/z 405.2 → 203.2 for flunarizine and m/z 413.1 → 203.2 for flunarizine‐d8. The validated concentration range was established from 0.10 to 100 ng/mL. The accuracy (96.1–103.1%), intra‐batch and inter‐batch precision (CV ≤ 5.2%) were satisfactory and the drug was stable in human plasma under all tested conditions. The method was used to evaluate the pharmacokinetics of 5 and 10 mg flunarizine tablet formulation in 24 healthy subjects. The pharmacokinetic parameters Cmax and AUC were dose‐proportional. 相似文献
15.
《Biomedical chromatography : BMC》2017,31(6)
A sensitive, selective and rapid liquid chromatography–tandem mass spectrometry (LC–MS/MS) method was developed for the quantification of gypenoside XLIX, a naturally occurring gypenoside of Gynostemma pentaphyllum in rat plasma and then validated according to the US Food and Drug Administration's Guidance for Industry: Bioanalytical Method Validation . Plasma samples were prepared by a simple solid‐phase extraction. Separation was performed on a Waters XBridgeTM BEH C18 chromatography column (4.6 × 50 mm, 2.5 μm) using a mobile phase of acetonitrile and water (62.5:37.5, v /v). Gypenoside XLIX and the internal standard gypenoside A were detected in the negative ion mode using selection reaction monitoring of the transitions at m/z 1045.6 → 913.5 and 897.5 → 765.4, respectively. The calibration curve was linear (R 2 > 0.990) over a concentration range of 10–7500 ng/mL with the lower quantification limit of 10 ng/mL. Intra‐ and inter‐day precision was within 8.6% and accuracy was ≤10.2%. Stability results proved that gypenoside XLIX and the IS remained stable throughout the analytical procedure. The validated LC–MS/MS method was then applied to analyze the pharmacokinetics of gypenoside XLIX after intravenous administration to rats (1.0, 2.0 and 4.0 mg/kg). 相似文献
16.
Triptolide is one of the main active ingredients of Tripterygium wilfordii Hook. F. In this study, a sensitive LC–MS/MS method was established and validated to determine the concentration of triptolide in rat plasma. Triptolide and an internal standard [(5R)‐5‐hydroxytriptolide] were extracted from 100 μL of rat plasma with acetonitrile, and the dried residue was then reconstituted and reacted with benzylamine to produce benzylamine triptolide and benzylamine (5R)‐5‐hydroxytriptolide. Derivatization increased the sensitivity of triptolide detection by ~100‐fold. Quantification was performed using a QTRAP 5500 tandem mass spectrometer with positive electrospray ionization in multiple reaction monitoring mode with an ion transition m/z 468.5 → 192.0 for benzylamine triptolide and m/z 484.3 → 192.1 for benzylamine (5R)‐5‐hydroxytriptolide. Good linearity was observed in the range of 0.030–100 ng/mL with a lower limit of quantitation of 0.030 ng/mL. The intra‐ and inter‐day precision was <6.5%, and the accuracy ranged from ?11.7 to ?4.4%. The recovery remained consistent and was reproducible at different concentrations. This method was successfully applied to the study of triptolide drug–drug interactions in Sprague–Dawley rats. With the use of itraconazole (40 mg/kg, p.o.) as a CYP3A inhibitor, the plasma exposure of triptolide in rats was increased by 36%. 相似文献
17.
《Biomedical chromatography : BMC》2018,32(3)
Isomers β‐asarone and α‐asarone have recently been demonstrated to have differential pharmacological activities . Here, we report an LC–MS/MS method developed using acetonitrile to extract two isomeric phenylpropenes from rat plasma. Separation was achieved using a XDB‐C18 column (100 × 2.1 mm; i.d., 1.8 μm) with a mobile phase of methanol–0.1% formic acid (55:45, v/v) at a flow rate of 0.3 mL/min. Calibration curves ranging from 5.20 to 2080 ng/mL for β‐asarone and from 3.68 to 1470 ng/mL for α‐asarone were linear (r2 ≥ 0.9938) with the lower limits of quantification being 5.20 and 3.68 ng/mL for both isomers. Intravenous administration of β‐asarone (2.22 mg/kg) and α‐asarone (2.36 mg/kg) in rats yielded half‐lives of 13.40 ± 4.11 and 28.88 ± 7.82 min with clearance values of 0.196 ± 0.062 mL/min/kg and 0.112 ± 0.012 mL/min/kg for β‐asarone and α‐asarone, respectively. 相似文献
18.
Kai Niu Huiyu Yan Chunjie Guo Sixi Zhang Wei Zhu Shiyong Teng 《Biomedical chromatography : BMC》2019,33(3)
A highly sensitive LC–MS/MS method was developed to measure oroxin B in rat plasma and tissue homogenates. The analyte and IS were isolated from biological matrices by a simple protein precipitation followed by centrifugation. Detection was conducted by electrospray negative‐ionization mass spectrometry in selected‐reaction monitoring mode. The assay was linear in the concentration range 4.52–904 ng/mL with intra‐ and inter‐day precision of <14.41%. It was successfully applied to the pharmacokinetics and tissue distribution studies of oroxin B after an intravenous dose of 1.0 mg/kg in rats. The results would be useful for further development of oroxin B. 相似文献
19.
Siva Sankara Rao Yadlapalli Naresh Kumar Katari Surendra Babu Manabolu Surya 《Biomedical chromatography : BMC》2019,33(4)
A highly sensitive, specific and rapid liquid chromatography–tandem mass spectrometry (LC–MS/MS) analytical method has been developed and validated for the determination of ospemifene in human plasma using ospemifene‐d4 as an internal standard. Solid‐phase extraction technique with Phenomenex Strata X‐33 μm polymeric sorbent cartridges (30 mg/1 mL) was used to extract the analytes from the plasma. The chromatographic separation was achieved on Agilent Eclipse XDB‐Phenyl, 4.6 × 75 mm, 3.5 μm column using the mobile phase composition of methanol and 20 mm ammonium formate buffer (90:10, v/v) at a flow rate of 0.9 mL/min. A detailed method validation was performed as per the US Food and Drug Administration guidelines and the calibration curve obtained was linear (r2 = 99) over the concentration range 5.02–3025 ng/mL. The API‐4500 MS/MS was operated under multiple reaction monitoring mode during the analysis. The proposed method was successfully applied to a pharmacokinetic study in healthy human volunteers after oral administration of an ospemifene 60 mg tablet under fed conditions. 相似文献
20.
《Biomedical chromatography : BMC》2017,31(3)
MLN0128, an mTOR kinase inhibitor, is currently undergoing clinical investigation for treatment of a variety of cancers. To support this work, an LC–MS/MS method has been developed for the determination of MLN0128 in human plasma. A structural analog STK040263 was used as the internal standard. Both MLN0128 and the IS were first extracted from plasma using methyl tert ‐butyl ether; then separated on a Waters XTerra® MS C18 column using a mobile phase consisting of methanol–acetonitrile–10.0 mm ammonium formate (34:6:60, v /v/v) at a flow rate of 0.300 mL min−1. Quantitation of MLN0128 was done by positive electrospray ionization tandem mass spectrometry in multiple‐reaction‐monitoring mode. This method has a total run time of <4 min with the retention times of 1.95 and 2.94 min for the IS and MLN0128, respectively. The method has been validated per the US Food and Drug Administration guidance for bioanalytical method validation. It has a calibration range of 0.100–50.0 ng mL−1 in human plasma with a correlation coefficient > 0.999. The overall assay accuracy and precision were ≤ ± 4 and ≤8%, respectively. The IS normalized recovery of MLN0128 was 98–100%. The stability studies showed that MLN0128 was stable under all tested conditions. The method developed may be useful for clinical studies of MLN0128. 相似文献