首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 832 毫秒
1.
Terbinafine, a widely used antifungal drug, is a challenging molecule for quantitative bioanalysis due to certain factors contributing assay variability. Despite previous attempts at human plasma determination of terbinafine, exhaustive stability of the drug or an internal standard was lacking. Internal standard stability with negligible variation throughout the analysis is an indicator of a reliable bioanalytical method as the majority of LC–MS/MS assays are based on analyte/IS response ratios for quantitation. A newly developed high‐throughput simple LC‐MS/MS method is described for human plasma determination of terbinafine using naftifine internal standard and eluting all compounds within 2 min. A solid‐phase extraction of terbinafine achieving mean recovery of 84.3% (CV < 4%) without compromising sensitivity (limit of quantitation 5.11 ng/mL) or linearity (5.11–3014.19 ng/mL) is delineated in this paper. A heated nebulizer in positive multiple reaction monitoring mode was employed with transitions m/z 292.2 →141.1 and 288.2 →117.0 for terbinafine and naftifine, respectively, resulting in excellent chromatographic separation on a Hypurity Advance (50 × 4.6 mm, 5 µm) column. The developed method was successfully applied to clinical samples and for the first time demonstrated marked improved extraction efficiency and reliable long‐term plasma stability results without any internal standard response variation during the entire course of study. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

2.
A sensitive, specific and simple LC‐MS/MS method was developed for the identification and quantification of bivalirudin in human plasma using diazepam as an internal standard (IS). The API‐4000 LC‐MS/MS was operated under multiple‐reaction monitoring mode using electrospray ionization. The sample preparation consisted of an easy protein precipitation sample pretreatment with methanol. Chromatographic separation was achieved on a Zorbax Eclipse plus C18 100 × 2.1 mm column with a mobile phase of water–methanol–0.1% formic acid. The analytes were detected with a triple quadrupole Quantum Access with positive ionization. Ions monitored in the multiple‐reaction monitoring mode were m/z 1091 → 650 for bivalirudin (at 2.70 min) and m/z 285 → 193 for diazepam (at 3.85 min). The developed method was validated in human plasma with a lower limit of quantitation of 20 µg/L for bivalirudin. A linear response function was established for the range of concentrations 20–10,000 µg/L (r > 0.998) for bivalirudin. The intra‐ and inter‐day precision values for bivalirudin met the acceptance criteria as per US Food and Drug Administration guidelines. Bivalirudin was stable in the battery of stability studies, viz. bench‐top, freeze–thaw cycles and long‐term stability. The developed assay method was applied to an intravenous administration study in humans. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

3.
A simple LC‐MS/MS method has been developed and validated for the quantification of endogenous myo‐ and chiro‐inositol in human urine. myo‐ and chiro‐Inositol were completely resolved from other carbohydrates and there were no interference peaks in human urine. The correlation coefficient (n = 3) was greater than 0.9991 over the range 0.05–25.0 µg/mL with the weighted (1/C2) least square method. Precision (%RSD) and accuracy (%RE) were 0–10.0% and 0–6.0% for the intra‐day assay (n = 5) and 0–14.3% and 0–10.0% for the inter‐day assay (n = 5). myo‐ and chiro‐Inositol have been shown to be stable in human urine stored at room temperature and for three freeze–thaw cycles. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

4.
We optimized and validated a rapid and sensitive liquid chromatography–tandem mass spectrometry (LC‐MS/MS) method for the quantification of six metabolites of homocysteine metabolism: homocysteine, methionine, cysteine, S‐adenosylmethionine, S‐adenosylhomocysteine and betaine. The detection limits for these metabolites were in the nanomolar range, and the intra‐ and inter‐day precisions were lower than 20% of the relative standard deviations. The method was specifically designed for the determination of the intracellular concentrations of the metabolites in cultured cells. To study the role of betaine–homocysteine S‐methyltransferase (BHMT), HepG2 cells and HepG2 cells that were stably transfected with BHMT (BHMTHepG2) were treated with homocysteine or with a specific inhibitor of BHMT, and metabolite levels were subsequently measured. Severely compromised methyl group metabolism in the HepG2 cells, which is typical of cancer‐derived cells, prevented clear evaluation of the changes caused by the external manipulations of homocysteine metabolism. However, the ease of handling these cells and the almost unlimited source of experimental material supplied by cells in permanent culture allowed us to develop a reliable methodology. The precautions concerning intracellular metabolite determinations using LC‐MS/MS in cultured cells that are expressed in this work will have global validity for future metabolomics studies. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

5.
A sensitive and high‐throughput LC‐MS/MS method has been developed and validated for the combined determination of esomeprazole and naproxen in human plasma with ibuprofen as internal standard. Solid‐phase extraction was used to extract both analytes and internal standard from human plasma. Chromatographic separation was achieved in 4.0 min on XBridge C18 column using acetonitrile–25 mM ammonium formate (70:30, v/v) as mobile phase. Mass detection was achieved by ESI/MS/MS in negative ion mode, monitoring at m/z 344.19 → 194.12, 229.12 → 169.05 and 205.13 → 161.07 for esomeprazole, naproxen and IS, respectively. The calibration curves were linear from 3.00 to 700.02 ng/mL for esomeprazole and 0.50 to 150.08 ng/mL for naproxen. The intra‐ and inter‐batch precision and accuracy across four quality control levels met established criteria of US Food and Drug Administration guidelines. The assay is suitable for measuring accurate esomeprazole and naproxen plasma concentrations in human bioequivalence study following combined administration. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

6.
A simple, rapid and sensitive method for quantification of atomoxetine by liquid chromatography–tandem mass spectrometry (LC‐MS/MS) was developed. This assay represents the first LC‐MS/MS quantification method for atomoxetine utilizing electrospray ionization. Deuterated atomoxetine (d3‐atomoxetine) was adopted as the internal standard. Direct protein precipitation was utilized for sample preparation. This method was validated for both human plasma and in vitro cellular samples. The lower limit of quantification was 3 ng/mL and 10 nm for human plasma and cellular samples, respectively. The calibration curves were linear within the ranges of 3–900 ng/mL and 10 nm to 10 µm for human plasma and cellular samples, respectively (r2 > 0.999). The intra‐ and inter‐day assay accuracy and precision were evaluated using quality control samples at three different concentrations in both human plasma and cellular lysate. Sample run stability, assay selectivity, matrix effect and recovery were also successfully demonstrated. The present assay is superior to previously published LC‐MS and LC‐MS/MS methods in terms of sensitivity or the simplicity of sample preparation. This assay is applicable to the analysis of atomoxetine in both human plasma and in vitro cellular samples. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

7.
A simple, selective and rapid HPLC‐MS/MS method was developed and validated for the determination of caderofloxacin in human plasma. Sparfloxacin was used as the internal standard (IS). After precipitation with methanol and dilution with the mobile phase, the samples were injected into the HPLC‐MS/MS system. The chromatographic separation was performed on a Zorbax XDB Eclipse C18 column (150 × 4.6 mm, 5 µm) with a mobile phase of ammonium acetate buffer (20 mm, pH 3.0)–methanol, 45:55 (v/v). The MS/MS analysis was done in positive mode. The multiple reaction monitoring transitions monitored were m/z 412.3 → 297.1 for caderofloxacin and m/z 393.2 → 292.2 for the IS. The calibration curve was linear over the range of 50.0–8000 ng/mL with an aliquot of 100 μL plasma. The precision of the assay was 2.0–9.4 and 6.6–11.5% for the intra‐ and inter‐run variability, respectively. The intra‐ and inter‐run accuracy (relative error) was 4.4–10.0 and ?1.2–4.0%. The total run time was 3.5 min. The assay was fully validated in accordance with the US Food and Drug Administration guidance. It was successfully applied to a pharmacokinetic study of caderofloxacin in healthy Chinese volunteers. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

8.
A rapid, simple and sensitive LC‐MS/MS method for the quantification of vinflunine in plasma was developed and validated. The analysis involved a simple liquid–liquid extraction. After making alkaline with NaOH, plasma was extracted with methyl tert‐butyl ether and the organic extract was then evaporated and the residue was reconstituted in mobile phase. The reconstituted solution was injected into an HPLC system and was subjected to reverse‐phase HPLC on a 5 µm ODS‐3 column at a flow‐rate of 0.2 mL/min. The mobile phase consisted of ammonium acetate (0.02 mol/L, pH = 3.0) and acetonitrile (20:80). Vinflunine was detected in the single ion monitoring mode using target ions at m/z 817.4/160.1/142.3 for vinflunine and m/z 447.2/128.3/112.1 for gefitinib (internal standard). Standard curves were linear over the concentration range of 5–1000 ng/mL. The mean predicted concentrations of the quality control samples deviated by less than 2% from the corresponding nominal values; the intra‐assay and inter‐assay precisions of the assay were within 7% relative standard deviation. The extraction recovery of vinflunine was more than 80%. The validated assay was applied to a pharmacokinetic study of vinflunine in plasma following the administration of a single vinflunine injection (2 mg/kg). Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

9.
A rapid and sensitive high‐performance LC‐MS/MS method was developed and validated for the simultaneous quantification of codeine and its metabolite morphine in human plasma using donepezil as an internal standard (IS). Following a single liquid‐liquid extraction with ethyl acetate, the analytes were separated using an isocratic mobile phase on a C18 column and analyzed by MS/MS in the selected reaction monitoring mode using the respective [M+H]+ ions, mass‐to‐charge ratio (m/z) 300/165 for codeine, m/z 286/165 for morphine and m/z 380/91 for IS. The method exhibited a linear dynamic range of 0.2–100/0.5–250 ng/mL for codeine/morphine in human plasma, respectively. The lower LOQs were 0.2 and 0.5 ng/mL for codeine and its metabolite morphine using 0.5 mL of human plasma. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. A run time of 2.0 min for each sample made it possible to analyze more than 300 human plasma samples per day. The validated LC‐MS/MS method was applied to a pharmacokinetic study in which healthy Chinese volunteers each received a single oral dose of 30 mg codeine phosphate.  相似文献   

10.
Altered serum proline levels are related to cancer metabolism. This study developed and validated a LC‐MS/MS method to analyze proline in human serum. Surrogate blank serum, coupled with stable isotope l ‐proline‐13C5,15 N as internal standard, was used for generating standard curves ranging from 2.5 to 100 μg/mL. Proline was extracted from serum samples using methanol. A Phenomenex Lux 5u Cellulose‐1 column (250 × 4.6 mm) was used for chromatographic separation with 40% methanol in 0.05% formic acid aqueous solution as a mobile phase. Mass detection was performed under positive ionization electrospray. Intra‐ and inter‐day accuracy and precision were <10%. The extraction recovery and matrix factor were 99.17 and 1.47%, respectively. Our study showed that the chiral column had high specificity and selectivity for separating proline from serum components. The assay was successfully applied for the quantification of human serum proline levels from 30 esophageal cancer patients and 30 healthy volunteers. Statistical analyses showed significantly lower levels of serum proline in the patients as compared with the healthy volunteers (p‐value = 0.011). We report here a simple, specific and reproducible LC‐MS/MS method for the quantification of proline in human serum as a potential screening biomarker for esophageal cancer. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

11.
European foulbrood (EFB) is a honeybee larvae disease caused by a bacterium Melissococcus plutonius. An amperometric immunosensor based on a sandwich assay was developed for rapid point‐of‐care detection of this pathogen. An in‐house made anti‐Melissococcus antibody was immobilized to a gold surface of a screen‐printed sensor via self‐assembled monolayer of cysteamine activated with glutaraldehyde. The direct impedimetric detection of captured microbial cells was tested, however, a better performance was obtained after the formation of sandwich with the peroxidase‐labeled antibody in the amperometric mode. The label‐free assay was limited by higher non‐specific binding. The limit of detection of the immunosensor was 6.6×104 CFU mL?1 (colony‐forming units) with wide linear range between 105 CFU mL?1 and 109 CFU mL?1. The whole analysis was completed within 2 h, which is shorter compared to common laboratory diagnostic tools, such as enzyme‐linked immunosorbent assay or polymerase chain reaction. Furthermore, atomic force microscopy was used for confirmation of the bacteria presence on the electrode surface. The developed immunosensor was successfully employed in the analysis of real samples of honeybees and larvae. The achieved results demonstrate the potential of the amperometric immunosensor for practical in‐field diagnosis of EFB, which can prevent infection spreading and connected losses of honeybee colonies.  相似文献   

12.
A sensitive and reliable liquid chromatography tandem mass spectrometry (LC–MS/MS) method was developed to determine cyanidin‐3‐O‐glucoside (Cy‐3G) in normal and streptozotocin‐induced diabetic rat plasma. Chromatographic separation was carried out on a Zorbax SB‐C18 (50 × 4.6 mm, 5 μm) column and mass spectrometric analysis was performed using a Thermo Finnigan TSQ Quantum Ultra triple‐quadrupole mass spectrometer coupled with an ESI source in the negative ion mode. Selected reaction monitoring mode was applied for quantification using target fragment ions m/z 447.3 → 285.2 for Cy‐3G and m/z 463.0 → 300.1 for quercetin‐3‐O‐glucoside (internal standard). The calibration curve was linear over the range 3.00–2700 ng/mL (r2 ≥ 0.99) with the lower limit of quantitation at 3.00 ng/mL. Intra‐ and inter‐day precision was <14.5% and mean accuracy was from −11.5 to 13.6%. Stability testing showed that Cy‐3G remained stable during the whole analytical procedure. After validation, the assay was successfully used to support a preclinical pharmacokinetic comparison of Cy‐3G between normal and diabetic rats. Results indicated that diabetes mellitus significantly altered the in vivo pharmacokinetic characteristics of Cy‐3G after oral administration in rats.  相似文献   

13.
ZMC1 {azetidinecarbothioic acid, [1‐(2‐pyridinyl) ethylidene] hydrazide} is a lead compound being developed as one of the first mutant p53 targeted anti‐cancer drugs. Establishing a precise quantitative method is an integral component of this development. The aim of this study was to develop a sensitive LC/MS/MS assay suitable for assessing purity, stability and preclinical pharmacokinetic studies of ZMC1. Acetonitrile protein precipitation extraction was chosen for plasma sample preparation with satisfactory recovery (84.2–92.8%) for ZMC1. Chromatographic separation was achieved on an Xterra C18 column (50 × 4.6 mm, 3.5 µm) using a gradient elution with mobile phase of 0.1% formic acid in water and acetonitrile. ZMC1 and internal standard 2‐amino‐6‐bromobenzothiazole were identified using selected‐ion monitoring mode at m/z 235.2/178.2 and m/z 231.0/150.0 at retention times of 5.2 and 6.3 min, respectively. The method was validated with a linearity range of 3.9–500.0 ng/mL in human plasma and showed acceptable reproducibility with intra‐ and interday precisions <5.9 and 10.5%, and accuracy within ±5.4% of nominal values. This analytical method together with basic stability data in plasma and plasma binding experiments provides a reliable protocol for the study of ZMC1 pharmacokinetics. This will greatly facilitate the pre‐clinical development of this novel anti‐cancer drug. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

14.
A rapid, selective and sensitive liquid chromatography/tandem mass spectrometry (LC‐MS/MS) method was developed and validated for determining bencycloquidium bromide (BCQB) in beagle dog plasma. The plasma sample was deproteinized with methanol which contained l‐ethyl‐bencycloquidium bromide as internal standard, and supernantant was assayed by LC‐MS/MS. The chromatographic separation was performed on a Phenomenex C18 column (100 × 2.0 mm, i.d., 3.0 μm) with a gradient programme mobile phase consisting of methanol and ammonium acetate (5 mm) containing 0.15% acetic acid and at a flow rate of 0.3 mL/min. Electrospray ionization in positive ion mode and selective reaction monitoring was used for the quantification of BCQB with a monitored transitions m/z 330.2 → 142.1 for BCQB and m/z 344.2 → 126.2 for IS. Validation results indicated that the lower limit of quantification was 0.05 ng/mL and the assay exhibited a linear range of 0.05–10.0 ng/mL and gave a correlation coefficient of 0.9998. The intra‐ and inter‐run precisions of the assay were 1.7–4.6 and 3.2–15.6%, respectively, and the intra‐ and inter‐day accuracies were ?8.8 to 1.1 and ?5.0 to 4.6%, respectively. The developed method was applied for the pharmacokinetic study of BCQB in beagle dogs following a single intranasal dose. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

15.
We developed and validated a semi‐automated LC/LC‐MS/MS assay for the quantification of imatinib in human whole blood and leukemia cells. After protein precipitation, samples were injected into the HPLC system and trapped onto the enrichment column (flow 5 mL/min); extracts were back‐flushed onto the analytical column. Ion transitions [M + H]+ of imatinib (m/z = 494.3 → 394.3) and its internal standard trazodone (372.5 → 176.3) were monitored. The range of reliable response was 0.03–75 ng/mL. The inter‐day precisions were: 8.4% (0.03 ng/mL), 7.2% (0.1 ng/mL), 6.5% (1 ng/mL), 8.2% (10 ng/mL) and 4.3% (75 ng/mL) with no interference from ion suppression. Autosampler stability was 24 hs and samples were stable over three freeze–thaw cycles. This semi‐automated method is simple with only one manual step, uses a commercially available internal standard, and has proven to be robust in larger studies. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

16.
Huangqi (Astragali Radix), a traditional Chinese herb, is widely used in clinical therapy in China. In addition, an anti‐allergic effect of constituents in Huangqi has been reported in the scientific literature. In the present study, cell membrane chromatography coupled online with UHPLC‐ESI‐MS/MS method was developed to screen, analyze and identify the anti‐allergic components of Huangqi. The Laboratory of Allergic Disease 2 (LAD2) cell was used to establish cell membrane chromatography, which was combined with UHPLC‐ESI‐MS/MS. The coupled system was then used to screen anti‐allergic components from Huangqi. Effects of active components were verified by histamine release assay. A component retained on the LAD2 cell membrane chromatography was identified as formononetin. Bioactivity of formononetin was investigated by histamine release assay in LAD2 cells, and it was found that formononetin could inhibit histamine release in a dose‐dependent manner from 1 to 100 μm . The LAD2 cell membrane chromatography online with UHPLC‐ESI‐MS/MS method is an effective technique for screening the anti‐allergic components of Huangqi.  相似文献   

17.
In this study, a rapid and sensitive analytical method for the determination of methyl‐, ethyl‐, propyl‐, and butyl esters of para‐hydroxy benzoic acid (parabens) in personal care products was developed and fully validated. Test portions were extracted with methanol followed by vortexing, sonication, centrifugation, and filtration without derivatization. The four parabens were quantified by GC‐MS/MS in the electron ionization mode. Four corresponding isotopically labeled parabens were selected as internal standards, which were added at the beginning of the sample preparation and used to correct for recovery and matrix effects. Sensitivity, extraction efficiency, and recovery of the respective analytes were evaluated. The coefficients of determination (r2) were all greater than 0.995 for the four parabens investigated. The recoveries ranged from 97 to 107% at three spiked levels and a one‐time (single) extraction efficiency greater than 97% was obtained. This method has been applied to screen 26 personal care products. This is the first time that a unique GC‐MS/MS method with dynamic selected reaction monitoring and confirmation of analytes has been used to determine these parabens in cosmetic personal care products.  相似文献   

18.
Thiorphan, the active metabolite of racecadotril, can undergo oxidation in biological matrices such as blood and plasma. In bioanalysis, a general approach for the stabilization of such a molecule is to derivatize the thiol group to a more stable thioether, often requiring complex handling procedures at the clinical site. In this research, the concept of dried blood spot (DBS) on‐card derivatization was evaluated to stabilize thiorphan. DBS cards were in‐house pre‐treated with 2‐bromo‐3′‐methoxyacetophenone and left to dry prior to blood spotting. Thiorphan was shown to be effectively derivatized to thiorphan–methoxyacetophenone once applied on the in‐house pre‐treated cards. Thiorphan–methoxyacetophenone was extracted by soaking a 6 mm DBS punch in methanol containing the internal standard (thiorphan–methoxyacetophenone‐D5). Chromatographic separation was achieved on a Waters XBridge C18 column with a gradient elution of 5 m m NH4HCO3 and methanol in 2.5 min and detection by ESI(+)/MS/MS. A linear (weighted 1/x2) relationship was obtained over a concentration range of 5.00–600.00 ng/mL. The assay met regulatory guidelines acceptance criteria for sensitivity, selectivity, precision and accuracy, matrix effect, recovery, dilution integrity and multiple stability evaluations. The DBS on‐card derivatization has shown to be an easy and reliable alternative form of sample collection for the quantification of thiorphan. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

19.
In the present study, we aimed to develop a reliable screening method based on liquid chromatography coupled with tandem mass spectrometry (LC–MS/MS) for the detection and quantification of naproxen, methyltestosterone and 17α‐hydroxyprogesterone caproate residues. The target analytes were extracted from samples of eel, flatfish and shrimp using acetonitrile with 1% acetic acid, followed by liquid–liquid purification with n‐hexane. Chromatographic separation was achieved on a reversed‐phase analytical column using 0.1% formic acid containing 10 mm ammonium formate in distilled water (A) and methanol (B) as mobile phases. All the matrix‐matched calibration curves were linear (R2 ≥ 0.99) over the concentration range of the tested analytes. Recovery at three spiking levels (0.005, 0.01 and 0.02 mg/kg) ranged from 68 to 117% with intra‐ and inter‐day precisions <10%. Five market samples for each matrix (eel, flatfish and shrimp) were collected and tested for method application. In summary, the proposed method is feasible to screen and quantify the analytes with high selectivity in aquatic food products meant for human consumption.  相似文献   

20.
4‐Methyl‐piperazine‐1‐carbodithioc acid 3‐cyano‐3, 3‐diphenylpropyl ester hydrochloride (TM208), a newly synthesized anticancer compound, was quantified using liquid chromatography–tandem mass spectrometry (LC‐MS/MS) for the first time. A simple, rapid and sensitive assay method using propranolol as internal standard (IS) after one‐step precipitation with acetonitrile was developed and validated to determine TM208 in rat plasma. Separation was achieved on a reverse‐phase C18 column with a mobile phase composed of methanol–water (pH4.0) containing 5 m m ammonium acetate in gradient elution mode. A triple quadrupole tandem mass spectrometer with electrospray ionization source was used as detector and operated by multiple reaction monitoring in the positive ion mode. Calibration curves were linear (r > 0.99) between 0.2 and 500 ng/mL. The quantitative limit was 0.2 ng/mL; reliable precision and accuracy were validated by relative standard deviation values in the range 3.44–13.15% and relative error values between ?0.58 and ?9.78%. The method was successfully applied to preclinical pharmacokinetic studies of TM208. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号