首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The magnetic metal‐organic framework MIL‐101(Cr) material‐based solid‐phase extraction method coupled with high‐performance liquid chromatography and tandem mass spectrometry was applied to extract seven triazine herbicides in rices. Fe3O4/MIL‐101(Cr) was synthesized using reduction‐precipitation method, in which steps including pre‐synthesis and modification of Fe3O4 nanoparticles were by‐passed. Various parameters including extraction solvent type and volume, ultrasonic extraction time, amount of Fe3O4/MIL‐101(Cr) microspheres, adsorption time, desorption volume and time were investigated. Under optimal conditions, the proposed method had the limit of detection (S/N = 3) and the limit of quantification (S/N = 10) of 1.08–18.10 and 3.60–60.20 pg/g, respectively. Relative standard deviations calculated for all herbicides with concentrations of 2 and 20 ng/g were in the range of 0.5 to 13% (n = 3). In addition, at the two above‐mentioned concentrations, the method achieved relative recoveries percentages of 79.3 to 116.7% when applied to determine the triazine herbicides in real samples spiked. This rapid, green, non‐polluting, pre‐concentrated extraction method was successfully developed and applied to analyze herbicides in rice samples.  相似文献   

2.
A facile and efficient strategy is developed to modify aptamers on the surface of the magnetic metal‐organic framework MIL‐101 for the rapid magnetic solid‐phase extraction of ochratoxin A. To the best of our knowledge, this is the first attempt to create a robust aptamer‐modified magnetic MIL‐101 with covalent bonding for the magnetic separation and enrichment of ochratoxin A. The saturated adsorption of ochratoxin A by aptamer‐modified magnetic MIL‐101 was 7.9 times greater than that by magnetic metal‐organic framework MIL‐101 due to the former's high selective recognition as well as good stability. It could be used for extraction more than 12 times with no significant changes in the extraction efficiency. An aptamer‐modified magnetic MIL‐101‐based method of magnetic solid‐phase extraction combined with ultra high performance liquid chromatography with tandem mass spectrometry was developed for the determination of trace ochratoxin A with limit of detection of 0.067 ng/L. Ochratoxin A of 4.53–13.7 ng/kg was determined in corn and peanut samples. The recoveries were in the range 82.8–108% with a relative standard deviation (n = 5) of 4.5–6.5%. These results show that aptamer‐modified magnetic MIL‐101 exhibits selective and effective enrichment performance and have excellent potential for the analysis of ultra‐trace targets from complex matrices.  相似文献   

3.
An efficient and fast dispersive magnetic solid phase extraction method was developed using MIL‐101(Cr)/poly (mercaptobenzothiazole)@magnetite nanoparticles for the preconcentration and determination of nitrophenols in river and rain water samples. High‐performance liquid chromatography‐Ultraviolet instrument was applied for the analysis of target nitrophenols. The effect of several variables on the extraction performance was explored via design of experiment approach. Limits of detection and linear dynamic ranges were attained in the range of 0.05–0.10 µg/L and 0.2–250 µg/L, respectively. The enrichment factors were in the range of 317–363. The precision (n = 3) of dispersive magnetic solid phase extraction method was in the range of 5.3–6.8%. Eventually, the method was utilized for the analysis of target nitrophenols in river and rain water samples.  相似文献   

4.
Here, we describe a simple one‐pot solvothermal method for synthesizing MIL‐101(Fe)@polydopamine@Fe3O4 composites from polydopamine‐modified Fe3O4 particles. The composite was used as a magnetic adsorbent to rapidly extract sulfonylurea herbicides. The herbicides were then analyzed by high‐performance liquid chromatography. The best possible extraction efficiencies were achieved by optimizing the most important extraction parameters, including desorption conditions, extraction time, adsorbent dose, salt concentration, and the pH of the solution. Good linearity was found (correlation coefficients >0.9991) over the herbicide concentration range 1–150 μg/L using the optimal conditions. The limits of detection (the concentrations giving signal/noise ratios of 3) were low, at 0.12–0.34 μg/L, and repeatability was good (the relative standard deviations were <4.8%, n = 6). The method was used successfully to determine four sulfonylurea herbicides in environmental water and vegetable samples, giving satisfactory recoveries of 87.1–108.9%. The extraction efficiency achieved using MIL‐101(Fe)@polydopamine@Fe3O4 was compared with the extraction efficiencies achieved using other magnetic composites (polydopamine@Fe3O4, Hong Kong University of Science and Technology (HKUST)‐1@polydopamine@Fe3O4, and MIL‐100(Fe)@polydopamine@Fe3O4). The results showed that the magnetic MIL‐101(Fe)@polydopamine@Fe3O4 composites have great potential for the extraction of trace sulfonylurea herbicides from various sample types.  相似文献   

5.
The present work describes a simple route to magnetize MIL‐53(Al)‐NH2 sorbent for rapid extraction of phenol residues from environmental samples. To extend the applications and performances of the metal‐organic frameworks in the field of adsorption materials, we combined the properties of metal‐organic frameworks and magnetite to decrease the extraction time and simplify the extraction process as well. In this study, a simple and quick vortex‐assisted dispersive magnetic solid phase extraction method for the extraction of ten United States Environmental Protection Agency's priority phenols from water samples prior to analysis by high‐performance liquid chromatography with photodiode array detection was proposed. The developed method exhibits a rapid enrichment of the target analytes within 10 s for extraction and 10 s for desorption. Low detection limits of 1.8‐41.7 µg/L and quantitation limits of 6.0‐139.0 µg/L with the relative standard deviations for intra‐ and interday analyses less than 12% were achieved. Satisfactory recoveries in the range of 80‐111% with the relative standard deviations less than 11% demonstrated that Fe3O4/MIL‐53(Al)‐NH2 is promising sorbent in the field of magnetic solid‐phase extraction for environmental samples.  相似文献   

6.
MIL‐101(Cr) is an excellent metal–organic framework with high surface area and nanoscale cavities, making it promising in solid‐phase extraction. Herein, we used MIL‐101(Cr) as a solid‐phase extraction packing material combined with fast detection of direct analysis in real time mass spectrometry (DART‐MS) for the analysis of triazine herbicides. After systematic optimization of the operation parameters, including the gas temperature of DART, the moving speed of the 1D platform, solvent for desorption, amount of MIL‐101(Cr) extraction time, eluent volume and salt concentration, this method can realize the simultaneous detection of five kinds of triazine herbicides. The limits of detection were 0.1~0.2 ng/mL and the linear ranges covered more than two orders of magnitude with the quantitation limits of 0.5~1 ng/mL. Moreover, the developed method has been applied for the analysis of lake water samples and the recoveries for spiked analytes were in the range of 85~110%. These results showed that solid‐phase extraction with metal–organic frameworks is an efficient sample preparation approach for DART‐MS analysis and could find more applications in environmental analysis.  相似文献   

7.
We adopted a facile hydrofluoric acid‐free hydro‐/solvothermal method for the preparation of four magnetic iron(III)‐based framework composites (MIL‐101@Fe3O4‐COOH, MIL‐101‐NH2@Fe3O4‐COOH, MIL‐53@Fe3O4‐COOH, and MIL‐53‐NH2@Fe3O4‐COOH). The obtained four magnetic iron(III)‐based framework composites were applied to magnetic separation and enrichment of the fungicides (prochloraz, myclobutanil, tebuconazole, and iprodione) from environmental samples before high‐performance liquid chromatographic analysis. MIL‐101‐NH2@Fe3O4‐COOH showed more remarkable pre‐concentration ability for the fungicides as compared to the other three magnetic iron(III)‐based framework composites. The extraction parameters affecting enrichment efficiency including extraction time, sample pH, elution time, and the desorption solvent were investigated and optimized. Under the optimized conditions, the standard curve of correlation coefficients were all above 0.991, the limits of detection were 0.04–0.4 μg/L, and the relative standard deviations were below 10.2%. The recoveries of two real water samples ranged from 71.1–99.1% at the low spiking level (30 μg/L). Therefore, the MIL‐101‐NH2@Fe3O4‐COOH composites are attractive for the rapid and efficient extraction of fungicides from environmental water samples.  相似文献   

8.
Novel inorganic–organic yolk–shell microspheres based on Preyssler‐type NaP5W30O11014? polyoxometalate and MIL‐101(Cr) metal–organic framework (P5W30/MIL‐101(Cr)) were synthesized by reaction of K12.5Na1.5[NaP5W30O110], Cr(NO3)3·9H2O and terephthalic acid under hydrothermal conditions at 200°C for 24 h. The as‐prepared yolk–shell microspheres were fully characterized using various techniques. All analyses confirmed the incorporation of the Preyssler‐type NaP5W30O11014? polyoxometalate into the three‐dimensional porous MIL‐101(Cr) metal–organic framework. The results revealed that P5W30/MIL‐101(Cr) demonstrated rapid adsorption of cationic methylene blue (MB) and rhodamine B (RhB) with ultrahigh efficiency and capacity, as well as achieving rapid and highly selective adsorption of MB from MB/MO (MO = methyl orange), MB/RhB and MB/RhB/MO mixtures. The P5W30/MIL‐101(Cr) adsorbent not only exhibited a high adsorption capacity of 212 mg g?1, but also could quickly remove 100% of MB from a dye solution of 50 mg l?1 within 8 min. The effects of some key parameters such as adsorbent dosage, initial dye concentration and initial pH on dye adsorption were investigated in detail. The equilibrium adsorption data were better fitted by the Langmuir isotherm. The adsorption kinetics was well modelled using a pseudo‐second‐order model. Also, the inorganic–organic hybrid yolk–shell microspheres could be easily separated from the reaction system and reused up to four times without any change in structure or adsorption ability. The stability and robustness of the adsorbent were confirmed using various techniques.  相似文献   

9.
A Cr‐based metal–organic framework, namely, MIL‐101(Cr), was modified with amino (NH2–) and urea (UR2–) groups, and the materials were evaluated as adsorbents for glyphosate, and a comparison with commercial activated carbon was also discussed. The effects of the adsorption factors, such as adsorbent concentration, adsorption time, pH and ionic strength were mainly investigated. The results showed that a pseudo‐second‐order rate equation described the adsorption kinetics mechanisms well, while the Langmuir model and the Freundlich model fitted different adsorption isotherms, respectively. Among the adsorbents we studied, NH2‐MIL‐101(Cr) showed the maximum adsorbing capacity, which is 64.25 mg/g when pH = 3.0, while UR2‐MIL‐101(Cr) did not reach the best adsorption performance due to the steric hindrance. The work opens up a new way for the modification of metal–organic frameworks for adsorption process.  相似文献   

10.
An easy‐to‐handle magnetic dispersive solid‐phase extraction procedure was developed for preconcentration and extraction of cocaine and cocaine metabolites in human urine. Divinyl benzene and vinyl pyrrolidone functionalized silanized Fe3O4 nanoparticles were synthesized and used as adsorbents in this procedure. Scanning electron microscopy, vibrating sample magnetometry, and infrared spectroscopy were employed to characterize the modified adsorbents. A high‐performance liquid chromatography with mass spectrometry method for determination of cocaine and its metabolites in human urine sample has been developed with pretreatment of the samples by magnetic dispersive solid‐phase extraction. The obtained results demonstrated the higher extraction capacity of the prepared nanoparticles with recoveries between 75.1 to 105.7% and correlation coefficients higher than 0.9971. The limits of detection for the cocaine and cocaine metabolites were 0.09–1.10 ng/mL. The proposed magnetic dispersive solid‐phase extraction method provided a rapid, environmentally friendly and magnetic stuff recyclable approach and it was confirmed that the prepared adsorbents material was a kind of highly effective extraction materials for the trace cocaine and cocaine metabolites analyses in human urine.  相似文献   

11.
An iron‐embedded porous carbon material (MIL‐53‐C) was fabricated by the direct carbonization of MIL‐53. The MIL‐53‐C possesses a high surface area and good magnetic behavior. The structure, morphology, magnetic property, and porosity of the MIL‐53‐C were studied by scanning electron microscopy, transmission electron microscopy, vibrating sample magnetometry, and N2 adsorption. With the use of MIL‐53‐C as the magnetic solid‐phase extraction adsorbent, a simple and efficient method was developed for the magnetic solid‐phase extraction of three hormones from water and human urine samples before high‐performance liquid chromatography with UV detection. The developed method exhibits a good linear response in the range of 0.02–100 ng/mL for water and 0.5–100 ng/mL for human urine samples , respectively. The limit of detection (S/N = 3) for the analytes was 0.005–0.01 ng/mL for water sample and 0.1–0.3 ng/mL for human urine sample. The limit of quantification (S/N = 10) of the analytes were in the range of 0.015–0.030 and 0.3–0.9 ng/mL, respectively.  相似文献   

12.
A dispersive micro‐solid‐phase extraction procedure coupled with capillary electrophoresis ultraviolet detection was developed for determination of verapamil in plasma samples. Graphene oxide/polydopamin was synthesized by a one‐step polymerization method, and graphene oxide/Fe3O4 (magnetic graphene oxide) nanocomposite was prepared by coprecipitation method. Moreover, they were fully characterized. The use of hazardous and water‐immiscible solvents was scaled down, and only 500 μL of acetone was required as the desorption solvent. The detector response concentration plots were linear in the range of 5–500 ng/mL, and the proposed method was validated according to guidelines. The precision and accuracy were less than 15%. Dispersive micro‐solid‐phase extraction method provides a rapid, environmentally friendly, and sensitive analysis for the verapamil in patient plasma samples, which is adequate for therapeutic drug monitoring and pharmacokinetic studies.  相似文献   

13.
In this work, a fast and simple magnetic dispersive solid phase extraction methodology was developed utilizing Ag@magnetite nanoparticles@graphene nanocomposite as an efficient magnetic nanosorbent for preconcentration and determine of five aromatic amines in water samples. The sorbent was characterized by diverse characterization techniques. After the extraction, high‐performance liquid chromatography with UV detection was utilized to analysis the aromatic amines. The effects of different factors on the extraction process were studied thoroughly via design of experiment and desirability function. Detection limits and linear dynamic ranges were obtained in the range of 0.10–0.20 and 0.3–300 μg/L, respectively. The relative standard deviations (n = 5) were in the range of 4.3–6.5%. Eventually, the method was employed for determination of target aromatic amines in various water samples.  相似文献   

14.
The application of layered double hydroxide–Al2O3–polymer mixed‐matrix disks for solid‐phase extraction is reported for the first time. Al2O3 is embedded in a polymer matrix followed by an in situ metal‐exchange process to obtain a layered double hydroxide–Al2O3–polymer mixed‐matrix disk with excellent flow‐through properties. The extraction performance of the prepared disks is evaluated as a proof of concept for the automated extraction using sequential injection analysis of organic acids (p‐hydroxybenzoic acid, 3,4‐dihydroxybenzoic acid, gallic acid) following an anion‐exchange mechanism. After the solid‐phase extraction, phenolic acids were quantified by reversed‐phase high‐performance liquid chromatography with diode‐array detection using a core–shell silica–C18 stationary phase and isocratic elution (acetonitrile/0.5% acetic acid in pure water, 5:95, v/v). High sensitivity and reproducibility were obtained with limits of detection in the range of 0.12–0.25 μg/L (sample volume, 4 mL), and relative standard deviations between 2.9 and 3.4% (10 μg/L, = 6). Enrichment factors of 34–39 were obtained. Layered double hydroxide–Al2O3–polymer mixed‐matrix disks had an average lifetime of 50 extractions. Analyte recoveries ranged from 93 to 96% for grape juice and nonalcoholic beer samples.  相似文献   

15.
A novel two‐step extraction technique combining ionic‐liquid‐based dispersive liquid–liquid microextraction with magnetic solid‐phase extraction was developed for the preconcentration and separation of aflatoxins in animal feedstuffs before high‐performance liquid chromatography coupled with fluorescence detection. In this work, ionic liquid 1‐octyl‐3‐methylimidazolium hexafluorophosphate was used as the extractant in dispersive liquid–liquid microextraction, and hydrophobic pelargonic acid modified Fe3O4 magnetic nanoparticles as an efficient adsorbent were applied to retrieve the aflatoxins‐containing ionic liquid. Notably, the target of magnetic nanoparticles was the ionic liquid rather than the aflatoxins. Because of the rapid mass transfer associated with the dispersive liquid–liquid microextraction and magnetic solid phase steps, fast extraction could be achieved. The main parameters affecting the extraction recoveries of aflatoxins were investigated and optimized. Under the optimum conditions, vortexing at 2500 rpm for 1 min in the dispersive liquid–liquid microextraction and magnetic solid‐phase extraction and then desorption by sonication for 2 min with acetonitrile as eluent. The recoveries were 90.3–103.7% with relative standard deviations of 3.2–6.4%. Good linearity was observed with correlation coefficients ranged from 0.9986 to 0.9995. The detection limits were 0.632, 0.087, 0.422 and 0.146 ng/mL for aflatoxins B1, B2, G1, and G2, respectively. The results were also compared with the pretreatment method carried out by conventional immunoaffinity columns.  相似文献   

16.
The precise control of pesticide residues in foodstuffs depends significantly on the clean extraction of analytes using specifically designed separation methods. In this study, a one‐pot sol–gel process was used for the preparation of a magnetic hybrid silica gel tetraethylortho silicate‐cyanopropyltriethoxy silane nanocomposite. The prepared material was characterized using energy dispersive X‐ray spectroscopy, Fourier transform infrared spectroscopy, single‐point specific surface area, and scanning electron microcopy. The synthesized magnetic hybrid material was used as a solid phase extraction sorbent for the extraction and preconcentration of some organophosphorus pesticides before gas chromatography with a microelectron capture detector. The performance of the proposed magnetic solid‐phase extraction technique was validated by linearity (0.05–2 ng/mL), correlation coefficients (r= 0.9993–0.9997), limit of detection (0.02–0.06 ng/mL, S/N = 3, = 3), and intraday (RSD = 1.5–8.7%, = 3) and interday precision (RSD = 5.5–9.3%, = 12), while the recovery in real samples and equilibrium adsorption capacity was 72.02–103.84% and 8–20 mg/g, respectively. The magnetic solid‐phase extraction based on the hybrid nanocomposite revealed a high enrichment factor, an appropriate dynamic range, and great absorptive ability toward the selected organophosphorus pesticides spiked in real water samples.  相似文献   

17.
Polypyrrole‐magnetite dispersive micro‐solid‐phase extraction method combined with ultraviolet‐visible spectrophotometry was developed for the determination of selected cationic dyes in textile wastewater. Polypyrrole‐magnetite was used as adsorbent due to its thermal stability, magnetic properties, and ability to adsorb Rhodamine 6G and crystal violet. Dispersive micro‐solid‐phase extraction parameters were optimized, including sample pH, adsorbent amount, extraction time, and desorption solvent. The optimum polypyrrole‐magnetite dispersive micro‐solid phase‐extraction conditions were sample pH 8, 60 mg polypyrrole‐magnetite adsorbent, 5 min of extraction time, and acetonitrile as the desorption solvent. Under the optimized conditions, the polypyrrole‐magnetite dispersive micro‐solid‐phase extraction with ultraviolet‐visible method showed good linearity in the range of 0.05–7 mg/L (R 2 > 0.9980). The method also showed a good limit of detection for the dyes (0.05 mg/L) and good analyte recoveries (97.4–111.3%) with relative standard deviations < 10%. The method was successfully applied to the analysis of dyes in textile wastewater samples where the concentration found was 1.03 mg (RSD ±7.9%) and 1.13 mg/L (RSD ± 4.6%) for Rhodamine 6G and crystal violet, respectively. It can be concluded that this method can be adopted for the rapid extraction and determination of dyes at trace concentration levels.  相似文献   

18.
In this work, a method for the analysis of benzoylurea insecticides, including hexaflumuron, flufenoxuron, lufenuron and chlorfluazuron, in tea samples by high‐performance liquid chromatography with Fe3O4‐hyperbranched polyester nanocomposite as the adsorbent for magnetic solid‐phase extraction was developed. The magnetic nanocomposite was prepared and characterized by infrared spectroscopy, vibrating sample magnetometry, and scanning electron microscopy. The as‐prepared nanocomposite was used as a sorbent for the extraction and preconcentration of pesticide residues in tea samples. The extraction and desorption conditions, including mass ratios of raw materials, amount of sorbent, pH value, extraction time, and desorption time, were investigated. Under the final conditions chosen for the analysis, good linearity was obtained for all the tested compounds, with R2 values of at least 0.9979. The limits of detection were determined in the range of 0.15–0.3 μg/L. The recovery obtained from the analysis of tea samples with various spiked concentrations was between 90.7 and 98.4%, with relative standard deviations (n = 4) lower than 4.1%. Furthermore, the present approach was successfully applied to the quantitative determination of residues of benzoylurea insecticides in real samples.  相似文献   

19.
A new simple and rapid pretreatment method for simultaneous determination of 19 sulfonamides in pork samples was developed through combining the QuEChERS method with dispersive liquid–liquid microextraction followed by ultra‐high performance liquid chromatography with tandem mass spectrometry. The sample preparation involves extraction/partitioning with QuEChERS method followed by dispersive liquid–liquid microextraction using tetrachloroethane as extractive solvent and the acetonitrile extract as dispersive solvent that obtained by QuEChERS. The enriched tetrachloroethane organic phase by dispersive liquid–liquid microextraction was evaporated, reconstituted with 100 μL acetonitrile/water (1:9 v/v) and injected into an ultra‐high performance liquid chromatography with a mobile phase composed of acetonitrile and 0.1% v/v formic acid under gradient elution and separated using a BHE C18 column. Various parameters affecting the extraction efficiency were investigated. Matrix‐matched calibration curves were established. Good linear relationships were obtained for all analytes in a range of 2.0–100 μg/kg and the limits of detection were 0.04–0.49 μg/kg. Average recoveries at three spiking levels were in the range of 78.3–106.1% with relative standard deviations less than 12.7% (n = 6). The developed method was successfully applied to determine sulfonamide residues in pork samples.  相似文献   

20.
Palladium nanoparticle‐incorporated metal–organic framework MIL‐101 (Pd/MIL‐101) was successfully synthesized and characterized using X‐ray diffraction, nitrogen physisorption, X‐ray photoelectron, UV–visible and infrared spectroscopies, and transmission electron microscopy. The characterization techniques confirmed high porosity and high surface area of MIL‐101 and high stability of nano‐size palladium particles. Pd/MIL‐101 nanocomposite was investigated for the Sonogashira cross‐coupling reaction of aryl and heteroaryl bromides with various alkynes under copper‐free conditions. The reusability of the catalyst was tested for up to four cycles without any significant loss in catalytic activity. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号