首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 10 毫秒
1.
A restricted‐access material–hybrid monolithic column was prepared based on single‐component organosiloxane and dynamic grafting of δ‐gluconolactone for on‐line solid phase extraction of tetracycline antibiotic residues from milk. The hybrid monolithic column was prepared in a stainless‐steel chromatographic column using methyltrimethoxysilane as the single precursor. δ‐Gluconolactone was covalently coupled to aminopropyl derivatized hybrid monolithic column, which formed hydrophilic structures on the surface of the pore of the restricted‐access material–hybrid monolithic column. The columns were characterized by scanning electron microscopy, thermogravimetric analysis, Fourier transform infrared spectroscopy, nitrogen adsorption, contact angle analysis, dynamic adsorption, and chromatographic performance evaluation. The restricted‐access material–hybrid monolithic column was applied to the on‐line extraction of tetracycline residues from milk. An enrichment factor of 15.8 and a good sample clean‐up effect were obtained under the optimized conditions. The recoveries of the three spiked milk samples were between 81.7 and 102.5% with relative standard deviations (n = 3) in the range of 2–5%. The limits of detection (S/N = 3) for target compounds were in the range of 3.80–9.03 μg/kg. The results show that the on‐line extraction using the restricted‐access material–hybrid monolithic column was powerful for food sample pretreatment with high selectivity and good clean‐up effect.  相似文献   

2.
Surfactant cetyltrimethylammonium bromide enhanced molybdenum disulfide was used as an adsorbent in pipette‐tip solid‐phase extraction for the pretreatment of sulfonamides in environmental water samples. The factors affecting the extraction recoveries of the analytes, including the sample pH value, amount of sorbent, type and volume of eluent solution, and salt concentration were optimized. This pipette‐tip solid‐phase extraction method demonstrated good linearity (0.05–10.0 µg/L) with a coefficient of determination of 0.9984–0.9996, limit of detection (0.2–0.4 ng/L) and limit of quantitation (0.5–1.0 ng/L), good analyte recoveries (76–91), and acceptable limit of quantitation (<10%) under the optimized conditions. These results indicated that the proposed method was a good tool for monitoring sulfonamides in environmental water samples.  相似文献   

3.
In order to improve the permeation and adsorption properties of graphene oxide, heteroatoms and deep eutectic solvent were introduced in this study. After being modified, the structural properties of graphene oxide were improved and the materials were applied to the determination of myricetin and rutin in tea sample by pipette‐tip solid‐phase extraction method. The materials were characterized by scanning electron microscopy, Fourier transform infrared spectroscopy, X‐Ray diffractomer, energy dispersive spectroscopy, atomic force microscope, and specific surface area by Brunauer–Emmett–Teller N2 adsorption desorption analysis. Meanwhile, they were tested by static and dynamic adsorption. The result showed that the materials after modifying had better adsorption amount for myricetin and rutin than graphene oxide. The calibration graphs of myricetin and rutin in MeOH were linear over 0.10–500.00 µg/mL, and the limits of detection and quantification were in the range of 0.00546–0.0182 µg/mL and 0.00741–0.0247 µg/mL, respectively. A reliable analytical method was developed for recognition targets in tea sample by DES modified nitrogen‐doped graphene oxide with satisfactory extraction recoveries (myricetin 99.77%, rutin 98.14%). It was potential for the rapid purification of myricetin and rutin in tea sample combined with the pipette‐tip solid‐phase extraction.  相似文献   

4.
QuEChERS original method was modified into a new version for pesticides determination in soils. The QuEChERS method is based on liquid–liquid portioning with ACN and was followed by cleanup step using dispersive SPE and disposable pipette tips. Gas chromatographic separation with MS detection was carried out for pesticides quantification. The method was validated using recovery experiments for 36 multiclass pesticides. Mean reco‐veries of pesticides at each of the four spiking levels between 10–300 μg/kg of soil ranged from 70–120% for 26 pesticides with RSD values less than 15%. The method achieved low limit of detection less than 7.6 μg/kg. Matrix effects were observed for 13 pesticides. Matrix effects were compensated by using matrix‐matched calibration. The method was applied successfully using d‐SPE or DPX in the analysis of the pesticides in soils from organic farming and integrated pest management.  相似文献   

5.
A poly(vinylphenylboronic acid–ethylene glycol dimethacrylate) monolithic material incorporated with graphene oxide was synthesized inside a poly(ether ether ketone) tube. This tube with boronate affinity monolith was coupled with a high‐performance liquid chromatography system through a six‐port valve to construct an online solid‐phase microextraction with high‐performance liquid chromatography system. The performance of this solid‐phase microextraction with high‐performance liquid chromatography system was demonstrated by standard glycoprotein in aqueous samples, namely, horseradish peroxidase. Some parameters that affect the extraction performance were investigated, including sampling rate, pH of sample solution, and sampling volume. Under the optimized conditions, the developed method showed high extraction efficiency toward horseradish peroxidase. The addition of graphene oxide greatly increased the extraction efficiency of boronate affinity monolith for horseradish peroxidase. The limit of detection of the proposed method was as low as 0.01 μg/mL by using ultraviolet detection. The recognition specificity was also evaluated by analyzing the mixture of bovine serum albumin (nonglycoprotein) and horseradish peroxidase. The results showed that this material could selectively extract horseradish peroxidase from the mixture, indicating its good specificity toward glycoproteins. The proposed method was further applied for analyzing rat plasma samples spiked with horseradish peroxidase. Good recovery and repeatability were obtained.  相似文献   

6.
A novel polymeric monolith column with a  β‐cyclodextrin‐graphene composite was prepared for extraction of methyl jasmonate. A simple, sensitive, and effective polymeric monolith microextraction with high‐performance liquid chromatography method has been presented for the determination. To carry out the best microextraction efficiency, several parameters such as sample flow rate, sample volume, and sample pH value were systematically optimized. In addition, the method validation showed a wide linear range of 5–2000 ng/mL, with a good linearity and low limits of detection for methyl jasmonate. The proposed method was successfully applied for the determination of methyl jasmonate in wintersweet flowers with recoveries of 90.67%. The result was confirmed by high‐performance liquid chromatography with mass spectrometry.  相似文献   

7.
This paper report a novel strategy for synthesis and application of CuS@ZnS@Fe3O4‐CNTs composite which has great potentials as artificial receptor for tartrazine trapping due to its ultrahigh surface area and functionality which is related to application of electrochemical route. A durable and economical pipette‐tip CuS@ZnS@Fe3O4‐CNTs nano‐composite miniaturized solid phase extraction coupled with UV‐Vis spectrophotometry was developed for clean‐up and determination of tartrazine from various water samples. Undoubtedly, presence of mild‐intensity/frequency ultrasound irradiation played a key role for reducing consumption of eluent volume by broking hydrogen bonds between retained analyte and sorbent. The influence of factors including pH, sorbent dosage, sonication time and eluent volume were investigated and optimum conditions were obtained using experimental design methodology. Under optimized conditions, good extraction efficiencies for the analyte were obtained with no matrix interference in the subsequent UV‐Vis. Good linearity for tartrazine in the range of 20‐5000 ng mL‐1 with correlation coefficients of R2 ≥ 0.99 and low detection limit close to 4.76 ng mL‐1 reveals high applicability of method for trace analysis.  相似文献   

8.
Graphene‐based pipette tip solid‐phase extraction was combined with ultra‐high performance liquid chromatography and tandem mass spectrometry for the determination of carbamate pesticide residues in fruit juice samples. Four milligrams of graphene was used as sorbent material to pack a 1000 μL pipette tip for the extraction of pirimicarb, propoxur, isoprocarb, fenobucarb, and diethofencarb from 3 mL of fruit juice sample. The whole extraction process was finished in 12 min, and the volume of eluent used was only 1.5 mL. Under the optimized conditions, good linear relationship (R > 0.999) and lower limits of detection (0.0022–0.033 ng/mL) were achieved. The recoveries at three spiked levels ranged from 80.90 to 124.60% with relative standard deviations less than 4.88%. Compared with commercially available sorbents including propylsulfonic acid silica, graphitized carbon black, and C18, graphene was superior in extraction efficiency. The proposed method is simple, rapid, sensitive, selective, and solvent saving.  相似文献   

9.
A poly(butyl methacrylate‐co‐ethylene dimethacrylate) monolithic column was fabricated and used as a novel sorbent for online solid‐phase extraction coupled to liquid chromatography with tandem mass spectrometry for the simultaneous determination of Sudan I–IV in chili pepper powder. The prepared columns were characterized by scanning electron microscopy, nitrogen adsorption‐desorption, and pressure drop measurements. Online solid‐phase extraction was performed on the synthesized monolithic column using 10 mM ammonium acetate solution as the loading solution with the aid of an online cleanup chromatography system. The desorption of Sudan I–IV was achieved with acetonitrile as the eluting solution at the flow rate of 0.5 mL/min. The extracted analytes were subsequently eluted into a C18 analytical column for chromatographic separation using a mixture of 10% acetonitrile/90% formic acid (0.5%) solution as the mobile phase. Under the optimized conditions, the developed method had linear range of 1.0–50 μg/kg, a detection limit of 0.3 μg/kg, and a quantification limit of 1.0 μg/kg for each analyte. The intraday and interday recoveries of Sudan I–IV in chili pepper powder samples ranged from 94.8 to 100.9% and 94.9 to 99.4%, respectively. The intraday and interday precision were between 3.37–7.01% and 5.01–7.68%, respectively.  相似文献   

10.
Solid‐phase membrane micro‐tip extraction (SPMMTE) and capillary electrophoresis (CE) methods were developed and validated for analysis of chloramphenicol in human plasma and urine samples. Iron composite nanoparticles were prepared using green technology. CE was carried out using a silica capillary (60 cm × 50 μm i.d.), phosphate buffer (50 mm , 8.0 pH)–acetonitrile (95:5, v/v) as the background electrolyte, 10 kV voltage, 280 nm detection, 20 s injection time and 27 ± 1°C temperature. Frusemide was used as an internal standard. The values of migration time, electrophoretic mobility, electrophoretic velocity and theoretical plates of chloramphenicol were 12.254 min, 4.44 × 10, 7.41 × 10 and 11,227. The limits of detection and quantitation of chloramphenicol were 0.1 and 1.0 μg/mL. Recovery of chloramphenicol in the standard solution was 95%. Solid‐phase membrane micro‐tip extraction and capillary electrophoresis methods may be used to analyze chloramphenicol in human plasma and urine samples of any patient.  相似文献   

11.
We report the fabrication of an anion‐exchange monolithic column in a stainless‐steel chromatographic column (10 mm × 2.1 mm i.d.) using [2‐(acryloyloxy) ethyl]trimethylammonium chloride as the monomer and ethylene dimethacrylate as the crosslinker. The prepared monolith was developed as the adsorbent for the on‐line solid‐phase extraction of salicylic acid in various animal‐origin foodstuffs combined with liquid chromatography and tandem mass spectrometry. The monolith was characterized by using Fourier transform infrared spectroscopy, scanning electron microscopy, nitrogen adsorption analysis, and elemental analysis. Potential factors affecting the on‐line solid‐phase extraction and liquid chromatography with tandem mass spectrometry analysis were studied in detail. Under the optimized conditions, the total analysis time including cleanup and liquid chromatography with tandem mass spectrometry separation was 17 min. The developed method gave the linear range of 15–750 μg/kg, detection limits (S/N = 3) of 5 μg/kg, and quantification limits (S/N = 10) of 15 μg/kg. The recoveries obtained by spiking 10, 20, and 100 μg/kg of salicylic acid in the animal‐origin food samples were in the range of 85.2–98.4%. In addition, the monolith was stable enough for 550 extraction cycles with the precision of peak area ≤11.6%.  相似文献   

12.
A β‐cyclodextrin‐modified attapulgite composite was prepared and used as a dispersive micro‐solid‐phase extraction sorbent for the determination of benzoylurea insecticides in honey samples. Parameters that may influence the extraction efficiency, such as the type and volume of the eluent, the amount of the sorbent, the extraction time and the ionic strength were investigated and optimized using batch and column procedures. Under optimized conditions, good linearity was obtained for all of the tested compounds, with R2 values of at least 0.9834. The limits of detection were determined in the range of 0.2–1.0 μg/L. The recoveries of the four benzoylurea insecticides in vitex honey and acacia honey increased from 15.2 to 81.4% and from 14.2 to 82.0%, respectively. Although the β‐cyclodextrin‐modified attapulgite composite did not show a brilliant adsorption capacity for the selected benzoylurea insecticides, it exhibited a higher adsorption capacity toward relatively hydrophobic compounds, such as chlorfluazuron and hexaflumuron (recoveries in vitex honey samples ranged from 70.0 to 81.4% with a precision of 1.0–3.7%). It seemed that the logPow of the benzoylurea insecticides is related to their recoveries. The results confirmed the possibility of using cyclodextrin‐modified palygorskite in the determination of relatively hydrophobic trace pharmaceutical residues.  相似文献   

13.
In this study, porous sandwich structure Fe3O4 nanoparticles coated by polyhedral oligomeric silsesquioxanes and β‐cyclodextrin were prepared by surface polymerization and were used as the magnetic solid phase extraction adsorbent for the extraction and determination of carbaryl and carbofuran. The Fe3O4 nanoparticles coated with polyhedral oligomeric silsesquioxanes and β‐cyclodextrin were characterized by Fourier transform infrared spectroscopy, X‐ray diffraction, thermogravimetric analysis, vibrating sample magnetometry, and scanning electron microscopy. After optimizing the extraction conditions, a method that combined magnetic solid phase extraction with high‐performance liquid chromatography was developed for the determination of carbaryl and carbofuran in apple. The method exhibited a good linearity in the range of 2–400 μg/kg for carbaryl and carbofuran (R= 0.9995), respectively. The limits of detection were 0.5 μg/kg of carbaryl and 0.7 μg/kg for carbofuran in apple, respectively. Extraction recoveries ranged from 94.2 to 103.1% with the preconcentration factor of 300 and the relative standard deviations were less than 5.9%. These results indicated that the method combined magnetic solid phase extraction with high‐performance liquid chromatography and was promising for the determination of carbaryl and carbofuran at trace amounts.  相似文献   

14.
利用溶胶-凝胶法,经过烷氧基硅烷的水解、硅羟基的缩聚、凝胶化、陈化、中孔制备、干燥和表面修饰等步骤制备了全氟癸基修饰的毛细管硅胶整体柱。采用该整体柱对全氟辛烷磺酸(PFOS)进行萃取富集,考察其富集特性和效率,并与传统的C18毛细管硅胶整体柱进行对比。结果表明,全氟癸基修饰毛细管硅胶整体柱(15 cm×75μm)对PFOS具有更高的吸附量和更好的富集选择性,其平均吸附量可以达到75 ng;样品中PFOS的质量浓度为0.25 mg/L时,富集倍数平均可以达到29倍。此全氟癸基修饰毛细管硅胶整体柱对PFOS具有良好的萃取富集性能,可用于水质中痕量PFOS的萃取富集。  相似文献   

15.
A rapid, sensitive and reproducible HPLC method was developed and validated for the analysis of haloperidol and its three main metabolites in human plasma. The analysis was carried out on a monolithic silica column (Chromolith Performance RP-18e, 100 x 4.6 mm). The mobile phase consisted of sodium phosphate (0.1 m, pH 3.5)-acetonitrile (80:20, v/v) at a flow rate of 2.0 mL/min. UV detection at 230 nm was used, with the detection limits of these compounds ranging from 2 to 5 ng. The separation factors of all studied compounds were in the range 2.30-16.32, while the resolution factors were from 1.00 to 5.37.  相似文献   

16.
A time‐saving method was applied to synthesize methyltrimethoxy‐modified magnetic mesoporous silica with or without p‐toluenesulfonic acid as the catalyst for magnetic solid‐phase extraction. The synthesized materials were systematically characterized. Results demonstrated that methyltrimethoxy modified magnetic mesoporous silica with p‐toluenesulfonic acid as the catalyst has a relatively smaller aperture and extreme hydrophobicity (water contact angle of 135°). To evaluate the feasibility of these prepared materials as effective adsorbents, it was combined with gas chromatography and electron capture detection to determine 26 polychlorinated biphenyls in environmental water. The result revealed that methyltrimethoxy modified magnetic mesoporous silica with p‐toluenesulfonic acid as the catalyst had the best extraction efficiency and recovery. Under the optimized extracted conditions, the proposed method showed good linearity within the concentration range of 5 to 200 ng/L with correlation coefficients of 0.9969 to 0.9999. The limits of detection and quantification based on signal‐to‐noise ratios of 3 and 10 were in the range of 0.16 to 0.91 and 0.52 to 3.0 ng/L, respectively. The polychlorinated biphenyl concentrations in environmental water samples were successfully determined using the developed method. PCB008 and PCB110 were 4.05 and 8.52 ng/L in Red‐Star lake water (Hubei Province, China), respectively.  相似文献   

17.
By synthesizing a molecular imprinted polymer as an efficient adsorbent, ciprofloxacin was micro‐extracted from seawater, human blood plasma and tablet samples by pipette‐tip micro solid phase extraction and determined spectrophotometrically. Response surface methodology was applied with central composite design to build a model based on factors affecting on microextraction of ciprofloxacin; including volume of eluent solvent, number of extraction cycles, number of elution cycles, and pH of sample. Other factors that affect extraction efficiency, such as type of eluent solvent, volume of sample, type, and amount of salt were optimized with one‐variable‐at‐a‐time method. Under optimum extraction condition, pH of sample solution was 7.0, volume of eluent solvent (methanol) was 200 µL, volume of sample solution was 10 mL, and the number of extraction and elution cycles was five and seven, respectively, amount of Na2SO4 (as salt) and MIP (as sorbent) were optimized at 150 and 2 mg, respectively. The linear range of the suggested method under optimum extraction factors was 5–150 µg/L with a limit of detection of 1.50 µg/L for the analyte. Reproducibility of the method (as relative standard deviation) was better than 7%.  相似文献   

18.
In this work, a magnetic β‐cyclodextrin polymer was successfully prepared and used as an adsorbent for the magnetic solid‐phase extraction of six benzoylurea insecticides (diflubenzuron, triflumuron, hexaflumuron, teflubenzuron, flufenoxuron, and chlorfluazuron) from honey, tomato, and environmental water samples. The influence of the main experimental conditions on the extraction was studied. Under the optimized conditions, the β‐cyclodextrin polymer@Fe3O4 showed an excellent extraction performance for the benzoylurea insecticides. A good linearity was obtained for the analytes in the range of 3.0–800 ng/g for honey samples, 0.3–160 ng/g for tomato samples, and 0.1–80.0 ng/mL for water samples, with the correlation coefficients above 0.9998. Satisfactory repeatabilities were achieved, with the relative standard deviations less than 5.7%. The limits of detection (S/N = 3) of the method for the benzoylurea insecticides were 0.2–0.8 ng/g for honey samples, 0.04–0.10 ng/g for tomato samples, and 0.02–0.05 ng /mL for water samples. The method was successfully used for the determination of the six benzoylurea insecticides residues in honey, tomato, and environmental water samples with a satisfactory result.  相似文献   

19.
To extract flavone glycosides efficiently, a new extraction material based on 4‐butylaniline‐bonded silica gel was prepared using a two‐step grafting method including a ring‐opening reaction and synchronous hydrolysis. Preparation of the silica‐based material was easily achieved under mild conditions, and the material was characterized by Fourier transform infrared spectroscopy, elemental analysis, and scanning electron microscopy. The material was used in solid‐phase extraction, and the extraction can be performed in neutral conditions without regard to ionic strength. Selectivity tests of 14 compounds on the extraction cartridge showed that the material has a high affinity to flavone glycosides in contrast to octadecyl silica, and the extraction yields for four flavone glycosides were found to be >93%. Selectivity tests further reveal that the adsorption on its surface is likely attributed to multiple interactions, including hydrophobic interactions, π–π interactions, and hydrogen bonding. To explore the applicability of 4‐butylaniline‐bonded silica gel, naringin and hesperidin from Simotang oral liquid were extracted, and the extraction yields were >90%, which is distinguished from <28% on octadecyl silica cartridge.  相似文献   

20.
In this study, the new and efficient three‐dimensional network porous aromatic frameworks materials called Silica‐PAFs‐a, Florisil‐PAFs‐a, Silica‐PAFs‐b, and Florisil‐PAFs‐b were first synthesized. The properties of materials were analyzed by five characterization methods. The materials were used as adsorbents in pipette‐tip solid‐phase extraction for the effective determination of carbendazim and thiabendazole in spinach sample. Meanwhile, the obtained materials were tested by static adsorption and dynamic adsorption. The result showed that the specific surface area of materials greatly increased after introducing three‐dimensional network porous aromatic frameworks. Microstructural modification exposed a large number of amino reactive groups that made them have a better adsorption amount for the two targets. The calibration graphs of carbendazim and thiabendazole in methanol were linear over 0.10–300.0 µg/mL, and the limits of detection and quantification were 0.00546 and 0.0182 µg/mL, and 0.00741 and 0.0247µg/mL respectively. A reliable analytical method was developed for recognition targets in spinach sample by Silica‐PAFs‐b with satisfactory extraction recoveries (96.25 and 100.51%). The proposed method using the material was applied for trace analysis of the carbendazim and thiabendazole residue.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号