首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
A robust, specific and fully validated LC‐MS/MS method as per general practices of industry has been developed for estimation of lacidipine (LAC) with 100 μL of human plasma using lacidipine‐13C8 as an internal standard (IS). The API‐4000 LC‐MS/MS was operated under the multiple reaction‐monitoring mode. A simple liquid–liquid extraction process was used to extract LAC and IS from human plasma. The total run time was 3.0 min and the elution of LAC and IS occurred at 1.96 and 1.97 min; this was achieved with a mobile phase consisting of 5 mm ammonium acetate buffer–acetontrile (15:85 v/v) at a flow rate of 0.60 mL/min on a Zorbax SB C18 (50 × 4.6 mm, 5 µm) column. A linear response function was established for the range of concentrations 50–15,000 pg/mL (r > 0.998) for LAC. The current developed method has negligible matrix effect and is free from unwanted adducts and clusters which are formed owing to system such as solvent or mobile phase. The developed assay method was applied to an oral pharmacokinetic study in humans and successfully characterized the pharmacokinetic data up to 72 h. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

2.
Pogostone is an important constituent of Pogostemon cablin (Blanco) Benth., and possesses various known bioactivities. A rapid, simple and sensitive liquid chromatography tandem mass spectrometry (LC‐MS/MS) method was developed for the analysis of pogostone in rat plasma using chrysophanol as internal standard (IS). The analytes were extracted with methanol and separated using a reversed‐phase YMC‐UltraHT Pro C18 column. Elution was achieved with a mobile phase consisting of methanol–water (75:25, v/v) for 5 min at a flow rate of 400 μL/min. The precursor/product transitions (m/z) under MS/MS detection with negative electrospray ionization (ESI) were 223.0 → 139.0 and 253.1 → 224.9 for pogostone and IS, respectively. The calibration curve was linear over the concentration range 0.05–160 µg/mL (r = 0.9996). The intra‐ and inter‐day accuracy and precision were within ±10%. The validated method was successfully applied to the preclinical pharmacokinetic investigation of pogostone in rats after intravenous (5, 10 and 20 mg/kg) and oral administration (5, 10 and 20 mg/kg). Finally, the oral absolute bioavailability of pogostone in rats was calculated to be 70.39, 78.18 and 83.99% for 5, 10 and 20 mg/kg, respectively. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

3.
A simple, rapid and sensitive liquid chromatography/positive ion electro‐spray tandem mass spectrometry method (LC‐MS/MS) was developed and validated for the quantification of fexofenadine with 100 μL human plasma employing glipizide as internal standard (IS). Protein precipitation was used in the sample preparation procedure. Chromatographic separation was achieved on a reversed‐phase C18 column (5 μm, 100 × 2.1 mm) with methanol : buffer (containing 10 mmol/L ammonium acetate and 0.1% formic acid; 70 : 30, v/v) as mobile phase. The total chromatographic runtime was approximately 3.0 min with retention time for fexofenadine and IS at approximately 1.9 and 2.1 min, respectively. Detection of fexofenadine and IS was achieved by LC‐MS/MS in positive ion mode using 502.1 → 466.2 and 446.0 → 321.1 transitions, respectively. The method was proved to be accurate and precise at linearity range of 1–600 ng/mL with a correlation coefficient (r) of ≥0.9976. The validated method was applied to a pharmacokinetic study in human volunteers following oral administration of 60 or 120 mg fexofenadine formulations, successfully. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

4.
An improved, simple and highly sensitive LC‐MS/MS method has been developed and validated for quantification of febuxostat with 100 μL human plasma using febuxostat‐d7 as an internal standard (IS) according to regulatory guidelines. The analyte and IS were extracted from human plasma via liquid–liquid extraction using diethyl ether. The chromatographic separation was achieved on a Zorbax C18 column using a mixture of acetonitrile and 5 mm ammonium formate (60:40, v/v) as the mobile phase at a flow rate of 0.5 mL/min. The total run time was 5.0 min and the elution of febuxostat and IS occurred at 1.0 and 1.5 min, respectively. A linear response function was established for the range of concentrations 1–6000 ng/mL (r > 0.99). The precursor to product ion transitions monitored for febuxostat and IS were m/z 317.1 → 261.1 and 324.2 → 262.1, respectively. The intra‐ and inter‐day precisions (%RSD) were within 1.29–9.19 and 2.85–7.69%, respectively. The proposed method was successfully applied to pharmacokinetic studies in humans. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

5.
A simple and sensitive liquid chromatography–electrospray ionization–tandem mass spectrometry (LC‐ESI‐MS/MS) technique was developed and validated for the determination of sibutramine and its N‐desmethyl metabolites (M1 and M2) in human plasma. After extraction with methyl t‐butyl ether, chromatographic separation of analytes in human plasma was performed using a reverse‐phase Luna C18 column with a mobile phase of acetonitrile–10 mm ammonium formate buffer (50:50, v/v) and quantified by ESI‐MS/MS detection in positive ion mode. The flow rate of the mobile phase was 200 μL/min and the retention times of sibutramine, M1, M2 and internal standard (chlorpheniramine) were 1.5, 1.4, 1.3 and 0.9 min, respectively. The calibration curves were linear over the range 0.05–20 ng/mL, for sibutramine, M1 and M2. The lower limit of quantification was 0.05 ng/mL using 500 μL of human plasma. The mean accuracy and the precision in the intra‐ and inter‐day validation for sibutramine, M1 and M2 were acceptable. This LC‐MS/MS method showed improved sensitivity and a short run time for the quantification of sibutramine and its two active metabolites in plasma. The validated method was successfully applied to a pharmacokinetic study in human. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

6.
A rapid and sensitive UPLC–MS/MS method was established for the simultaneous quantification of 6′′′-feruloylspinosin, spinosin, jujuboside A, and jujuboside B in rat plasma after the oral administration of traditional and dispensing granules (DG) decoction of Ziziphi Spinosae Semen (ZSS). The four components were separated using 0.1% formic acid and acetonitrile as a mobile phase by gradient elution at a flow rate of 0.3 mL/min equipped with a C18 column (2.1 × 50 mm, 1.7 μm particle size, Acquity BEH C18). The mass spectrometer was operated under multiple reaction monitoring mode. An aliquot of 100 μL rat plasma was deproteinized by 300 μL methanol. The supernatant was injected into the UPLC–MS/MS system for analysis. The calibration curves displayed good linearity. The intra-day and inter-day precisions (RSD) were less than 7.3%. The accuracies ranged from −1.3 to 6.1%. The extraction recoveries ranged from 95.8 to 101.9%, and the matrix effects were satisfactory. For DG, half-life values (t1/2) of 6′′′-feruloylspinosin and Cmax of jujuboside A were elevated remarkably. MRT0–t of jujuboside B was significantly increased. No significant variation was observed for the pharmacokinetic parameters of spinosin. The results could provide a scientific basis for the clinical application of traditional and DG decoction of ZSS.  相似文献   

7.
A sensitive liquid chromatography coupled with tandem mass spectrometry (LC–MS/MS) method was developed and validated for the simultaneous determination of ramelteon and its active metabolite M‐II in human plasma. After extraction from 200 μL of plasma by protein precipitation, the analytes and internal standard (IS) diazepam were separated on a Hedera ODS‐2 (5 μm, 150 × 2.1 mm) column with a mobile phase consisted of methanol–0.1% formic acid in 10 mm ammonium acetate solution (85:15, v/v) delivered at a flow rate of 0.5 mL/min. Mass spectrometric detection was operated in positive multiple reaction monitoring mode. The calibration curves were linear over the concentration range of 0.0500–30.0 ng/mL for ramelteon and 1.00–250 ng/mL for M‐II, respectively. This method was successfully applied to a clinical pharmacokinetic study in healthy Chinese volunteers after a single oral administration of ramelteon. The maximum plasma concentration (Cmax), the time to the Cmax and the elimination half‐life for ramelteon were 4.50 ± 4.64ng/mL, 0.8 ± 0.4h and 1.0 ± 0.9 h, respectively, and for M‐II were 136 ± 36 ng/mL, 1.1 ± 0.5 h, 2.1 ± 0.4 h, respectively.  相似文献   

8.
A simple and rapid HPLC–MS/MS method was developed and validated for simultaneous measurement of phosphocreatine and its metabolites creatine and creatinine in children's plasma. A 50 μL aliquot of plasma was prepared by protein precipitation with acetonitrile–water (1000 μL, 1:1, v/v) followed by separation on a Hypersil Gold C18 column (35°C) with gradient mobile phase consisting of 2 mm ammonium acetate aqueous solution (pH 10) and methanol at a flow rate of 0.3 mL/min and analyzed by mass spectrometry in both positive (phosphocreatine) and negative (creatine and creatinine) ion multiple reaction monitoring mode. Good linearity (r > 0.99) was obtained for the three analytes. The intra‐day and inter‐day values of CV were <5.46% (?13.09% ≤ RE ≤ 2.57%). The average recoveries of the three analytes were 70.9–97.5%. No obvious impact was found for the quantitation of three analytes in normal, hemolyzed and hyperlipemic plasma. In the end, this method was successfully applied to a pharmacokinetic study of phosphocreatine in children (six cases) with viral myocarditis of children after intravenous infusion of 2 g of the test drug. The pharmacokinetc parameters of phosphocreatine/creatine were as follows: t1/2 0.24/0.83 h, Tmax 0.49/0.55 h, Cmax 47.34/59.29 μg/mL, AUClast 17.07/59.63 h μg/mL, AUCinf 17.16/79.01 h μg/mL and MRT 0.29/0.67 h.  相似文献   

9.
10.
A simple, selective and rapid HPLC‐MS/MS method was developed and validated for the determination of caderofloxacin in human plasma. Sparfloxacin was used as the internal standard (IS). After precipitation with methanol and dilution with the mobile phase, the samples were injected into the HPLC‐MS/MS system. The chromatographic separation was performed on a Zorbax XDB Eclipse C18 column (150 × 4.6 mm, 5 µm) with a mobile phase of ammonium acetate buffer (20 mm, pH 3.0)–methanol, 45:55 (v/v). The MS/MS analysis was done in positive mode. The multiple reaction monitoring transitions monitored were m/z 412.3 → 297.1 for caderofloxacin and m/z 393.2 → 292.2 for the IS. The calibration curve was linear over the range of 50.0–8000 ng/mL with an aliquot of 100 μL plasma. The precision of the assay was 2.0–9.4 and 6.6–11.5% for the intra‐ and inter‐run variability, respectively. The intra‐ and inter‐run accuracy (relative error) was 4.4–10.0 and ?1.2–4.0%. The total run time was 3.5 min. The assay was fully validated in accordance with the US Food and Drug Administration guidance. It was successfully applied to a pharmacokinetic study of caderofloxacin in healthy Chinese volunteers. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

11.
A sensitive and specific method based on liquid chromatography‐tandem mass spectrometry using electrospray ionization (LC‐ESI‐MS/MS) has been developed for the determination of Schisandrin and Schisandrin B in rat plasma. A 100 μL plasma sample was extracted by methyl tert‐butyl ether after spiking the samples with nimodipine (internal standard) and performed on an XTerra®MS‐C18 column (150 mm × 2.1 mm, 3.5 μm) with the mobile phase of acetonitrile–water–formic acid (80:20:0.2, v/v) at a flow rate of 0.2 mL/min in a run time of 8.5 min. The lower limit of quantification of the method was 40 ng/mL for Schisandrin and 20 ng/mL for Schisandrin B. The method showed reproducibility with intra‐day and inter‐day precision of less than 13.8% RSD, as well as accuracy, with inter‐ and intra‐assay accuracies between 93.5 and 107.2%. Finally, the LC‐ESI‐MS/MS method was successfully applied to study the pharmacokinetics of Schisandrin and Schisandrin B in rats after administration of Wurenchun commercial formulations to rats. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

12.
A highly sensitive, accurate and robust LC‐MS/MS method was developed and validated for determination of nimorazole (NMZ) in rat plasma using metronidazole (MNZ) as internal standard (IS). The analyte and IS were extracted from plasma by precipitating protein with acetonitrile and were chromatographed using an Agilent Poroshell 120, EC‐C18 column. The mobile phase was composed of a mixture of acetonitrile and 0.1 % formic acid (85:15 v/v). The total run time was 1.5 min and injection volume was 5 μL. Multiple reaction monitoring mode using the transitions of m/z 227.1 → m/z 114.0 for MNZ and m/z 172.10 → m/z 128.1 for IS were monitored on a triple quadrupole mass spectrometer, operating in positive ion mode. The calibration curve was linear in the range of 0.25–200 ng/mL (r2 > 0.9996) and the lower limit of quantification was 0.25 ng/mL in the rat plasma samples. Recoveries of NMZ ranged between 88.05 and 95.25%. The precision (intra‐day and inter‐day) and accuracy of the quality control samples were 1.25–8.20% and ?2.50–3.10, respectively. The analyte and IS were found to be stable during all sample storage and analysis procedures. The LC‐MS/MS method described here was validated and successfully applied to pharmacokinetic study in rats. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

13.
An accurate and sensitive LC–MS/MS method for determining thalidomide, 5‐hydroxy thalidomide and 5′‐hydroxy thalidomide in human plasma was developed and validated using umbelliferone as an internal standard. The analytes were extracted from plasma (100 μL) by liquid–liquid extraction with ethyl acetate and then separated on a BETASIL C18 column (4.6 × 150 mm, 5 μm) with mobile phase composed of methanol–water containing 0.1% formic acid (70:30, v/v) in isocratic mode at a flow rate of 0.5 mL/min. The detection was performed using an API triple quadrupole mass spectrometer in atmospheric pressure chemical ionization mode. The precursor‐to‐product ion transitions m/z 259.1 → 186.1 for thalidomide, m/z 273.2 → 161.3 for 5‐hydroxy thalidomide, m/z 273.2 → 146.1 for 5′‐hydroxy thalidomide and m/z 163.1 → 107.1 for umbelliferone (internal standard, IS) were used for quantification. The calibration curves were obtained in the concentrations of 10.0–2000.0 ng/mL for thalidomide, 0.2–50.0 ng/mL for 5‐hydroxy thalidomide and 1.0–200.0 ng/mL for 5′‐hydroxy thalidomide. The method was validated with respect to linear, within‐ and between‐batch precision and accuracy, extraction recovery, matrix effect and stability. Then it was successfully applied to estimate the concentration of thalidomide, 5‐hydroxy thalidomide and 5′‐hydroxy thalidomide in plasma samples collected from Crohn's disease patients after a single oral administration of thalidomide 100 mg.  相似文献   

14.
An LC–MS/MS method with internal standard tolfenamic acid for determining diclofenac sodium (DCF) in dairy cow plasma was developed and validated. Samples were processed with protein precipitation by cold formic acid–acetonitrile. Determination of DCF was performed using LC–ESI+–MS/MS with the matrix‐matched calibration curve. The results showed that the method was sensitive (LOD 2 ng mL?1, LOQ 5 ng mL?1), accurate (97.60 ± 5.64%), precise (<10%) and linear in the range of 5–10,000 ng mL?1. A single intravenous (i.v.) or intramuscular (i.m.) administration of 5% diclofenac sodium injection at a dose of 2.2 mg kg?1 was performed in six healthy dairy cows according to a two‐period crossover design. The main pharmacokinetic (PK) parameters after a single i.v. administration were as follows: t1/2β, 4.52 ± 1.71 h; AUC, 77.79 ± 16.76 h μg mL?1; mean residence time, 5.16 ± 1.11 h. The main PK parameters after a single i.m. administration were as follows: Tmax, 2.38 ± 1.19 h; Cmax, 7.46 ± 1.85 μg mL?1; t1/2β, 9.46 ± 2.86 h; AUC 67.57 ± 13.07 h μg mL?1. The absolute bioavailability was 87.37 ± 5.96%. The results showed that the diclofenac sodium injection had PK characteristics of rapid absorption and slow elimination, and high peak concentration and bioavailability in dairy cows, and that the recommended clinical dosage of diclofenac sodium injection is 2.2 mg kg?1.  相似文献   

15.
There is interest in monitoring plasma concentrations of N‐desalkylquetiapine in relation to antidepressant effect. A simple LC‐MS/MS method for quetiapine and four metabolites in human plasma (50 μL) has been developed to measure concentrations of these compounds attained during therapy. Analytes and internal standard (quetiapine‐d8) were extracted into butyl acetate–butanol (10:1, v/v) and a portion of the extract analysed by LC‐MS/MS (100 × 2.1 mm i.d. Waters Spherisorb S5SCX; eluent: 50 mmol/L methanolic ammonium acetate, pH* 6.0; flow‐rate 0.5 mL/min; positive ion APCI‐SRM, two transitions per analyte). Assay calibration (human plasma calibrators) was linear across the ranges studied (quetiapine and N‐desalkylquetiapine 5–800, quetiapine sulfoxide 100–15,000, others 2–100 µg/L). Assay validation was as per FDA guidelines. Quetiapine sulfone was found to be unstable and to degrade to quetiapine sulfoxide. In 47 plasma samples from patients prescribed quetiapine (prescribed dose 200–950 mg/day), the (median, range) concentrations found (µg/L) were: quetiapine 83 (7–748), N‐desalkylquetiapine, 127 (7–329), O‐desalkylquetiapine 12 (2–37), 7‐hydroxyquetiapine 3 (<1–48), and quetiapine sulfoxide 3,379 (343–21,704). The analyte concentrations found were comparable to those reported by others except that the concentrations of the sulfoxide were markedly higher. The reason for this discrepancy in unclear. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

16.
A selective and sensitive UHPLC‐MS/MS bioanalytical method to determine PT‐31, an analgesic drug candidate, in rat plasma was developed and validated. Analyses were performed using a UHPLC‐MS/MS system equipped with an electrospray ionization interface operating in the positive ionization mode using a C18 reversed‐phase column with a mobile phase of water:acetonitrile (68:31, v/v) containing 0.1% acetic acid eluting in a gradient mode with a flow rate of 0.3 mL/min. Plasma samples were deproteinized with cold acetonitrile containing 0.01% TFA (1:2, v/v) and 50 μL of the supernatant were injected into the system. PT‐31 and phenytoin (internal standard) retention times were roughly 1.0 and 1.5 min, respectively. Linear standard curves were plotted for the 0.01–10 µg/mL concentration range, with a coefficient of determination > 0.99. The method's precision was over 88%. Maximum intra‐ and inter‐day relative standard deviations were 14.6% and 11.6%, respectively. Interfering substances were not detected in the chromatogram, indicating that the method was specific. PT‐31 stability was assessed under different temperature and storage settings. The method was used to characterize PT‐31 plasma pharmacokinetics following administration of 5 mg/kg i.v. to Wistar rats. Therefore, the method described is sensitive, linear, precise and specific enough to determine PT‐31 in preclinical pharmacokinetic investigations. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

17.
Osthole, a major component isolated from the fruit of Cnidium monnieri (L.) Cusson, has been widely used in traditional Chinese medicine. We developed and validated a rapid and sensitive LC‐MS/MS method for the quantification of osthole in rat plasma. Sample preparation involved simple liquid–liquid extraction by ethyl acetate after addition of imperatorin as internal standard (IS). The analyte was separated using a C18 column with the mobile phase of methanol–0.1% formic acid (80:20, v/v) at a flow rate of 0.4 mL/min. The elutes were detected under positive electrospray ionization in multiple reaction monitoring mode. The method was sensitive with 0.5 ng/mL as the lower limit of detection. Good linearity was obtained over the range of 1.0–500.0 ng/mL. The intra and inter‐batch accuracy for osthole in rat plasma samples ranged from 99.5 to 108.1% and the variation was <8.9%. The stability, extraction efficiency and matrix effect were also acceptable. This method was successfully applied to the pharmacokinetic study of osthole in rat after intravenous and oral administration. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

18.
A specific and sensitive HPLC‐MS/MS method was developed and validated for the simultaneously quantification of isoliquiritigenin (ISL) and neoisoliquiritin (NIS) in rat plasma by oral administration. Analytes were analyzed on an Agilent 6460 LC‐MS/MS system (Agilent, USA) using an Agilent Zorbax SB‐C18 column (4.6 × 150 mm, 5 μm). Gradient elution was applied for the analyte separation using a mobile phase composed of 0.1% formic acid aqueous solution and methanol at a flow rate of 1.0 mL/min with a total running time of 12 min. The calibration curves for ISL and NIS showed good linearity in the concentrations ranging from 0.001 to 4.000 μg/mL with correlation coefficients >0.998. The precision, accuracy, recovery and stability were deemed acceptable. The method was applied to the pharmacokinetics study of ISL and NIS in rats by single and combination administration. The result showed that Cmax and AUC0→t of ISL were markedly increased from 0.53 to 1.20 μg/mL, and from 69.63 to 200.74 min μg/mL by combination administration. The mean t1/2 value was also prolonged from 64.55 to 203.74 min in the combination group. These results indicated that NIS may have been metabolized to ISL which increased the absorption and extended the elimination of ISL. However, little difference was found for NIS pharmacokinetics parameters between single NIS and the combination group, which suggested that there was no significant biotransformation of ISL to NIS. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

19.
Yiqifumai Injection is a lyophilized powder preparation widely used to treat coronary heart disease. However, its in vivo bioactive components and pharmacokinetic behavior remain unknown. Therefore a sensitive and specific LC–MS/MS was developed and validated for the simultaneous quantification of eight saponins and four lignans in beagle dog plasma. The plasma samples were pretreated by protein precipitation with methanol–acetonitrile (1:1, v/v). Chromatographic separation of all the 12 analytes and estazolam (internal standard, IS) was successfully accomplished on an Ultimate® XB‐C8 column (100 × 2.1 mm, 3 μm) with a gradient elution system. The total running time was 8 min with a flow rate of 0.40 mL/min. Acquisition of mass spectrometric data was performed via positive electrospray ionization in multiple reaction monitoring mode. The assay was fully validated in terms of selectivity, linear range, lower limit of quantitation, precision, accuracy, matrix effect, recovery and stability. This validated method was successfully applied to the pharmacokinetics of 12 bioactive components after intravenous administration of Yiqifumai Injection to beagle dogs at a dose of 0.541 g/kg.  相似文献   

20.
A simple, rapid and sensitive liquid chromatography–tandem mass spectroscopy (LC–MS/MS) method was developed and validated for the determination of ethyl gallate, a pharmacologically active constituent isolated from Lagerstroemia speciosa (Linn.) Pers. This method was used to examine the pharmacokinetics of ethyl gallate and its major metabolite gallic acid in rat plasma using propyl gallate as an internal standard. After precipitation of the plasma proteins with acetonitrile, the analytes were separated on a Zorbax SB‐C18 column (3.5 μm, 2.1 × 50 mm) with an isocratic mobile phase consisted of methanol–acetonitrile–10 mM ammonium acetate (10 : 25 : 65, v/v/v) containing 0.1% formic acid at a flow rate of 0.25 mL/min. The Agilent G6410A triple quadrupole LC/MS system was operated under the multiple‐reaction monitoring mode using the electrospray ionization technique in negative mode. The lower limits of quantification of gallic acid and ethyl gallate of the method were 0.5 and 1.0 ng/mL. The intra‐day and inter‐day accuracy and precision of the assay were less than 8.0%. This method has been applied successfully to a pharmacokinetic study involving the intragastric administration of ethyl gallate to rats. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号