首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The silica-based poly(dimethylsiloxane)(PDMS)microfluidic enzymatic reactor was reported along with itsanalytical features in coupling with MALDI TOF and ESI MS.Microfluidic chip was fabricated using PDMS cast-ing and O_2-plasma techniques,and used for the preparation of enzymatic reactor.Plasma oxidation for PDMS en-abled the channel wall of microfluidics to present a layer of silanol(SiOH)groups.These SiOH groups as anchorsonto the microchannel wall were linked covalently with the hydroxy groups of trypsin-encapsulated sol matrix.As aresult,the leakage of sol-gel matrix from the microchannel was effectively prevented.On-line protein analysis wasperformed with the microfluidic enzymatic reactor by attachment of stainless steel tubing electrode and replaceabletip.The success of trypsin encapsulation was investigated by capillary electrophoresis(CE)detection,and MALDITOF and ESI MS analysis.The lab-made device provided excellent extent of digestion even at the fast flow rate of7.0 μL/min with very short residence time of ca.2 s.In addition,the encapsulated trypsin exhibits increased stabil-ity even after continuous use.These features are the most requisite for high-throughput protein identification.  相似文献   

2.
This work describes the development of a novel microdevice for forensic DNA processing of reference swabs. This microdevice incorporates an enzyme‐based assay for DNA preparation, which allows for faster processing times and reduced sample handling. Infrared‐mediated PCR (IR‐PCR) is used for STR amplification using a custom reaction mixture, allowing for amplification of STR loci in 45 min while circumventing the limitations of traditional block thermocyclers. Uniquely positioned valves coupled with a simple rotational platform are used to exert fluidic control, eliminating the need for bulky external equipment. All microdevices were fabricated using laser ablation and thermal bonding of PMMA layers. Using this microdevice, the enzyme‐mediated DNA liberation module produced DNA yields similar to or higher than those produced using the traditional (tube‐based) protocol. Initial microdevice IR‐PCR experiments to test the amplification module and reaction (using Phusion Flash/SpeedSTAR) generated near‐full profiles that suffered from interlocus peak imbalance and poor adenylation (significant ?A). However, subsequent attempts using KAPA 2G and Pfu Ultra polymerases generated full STR profiles with improved interlocus balance and the expected adenylated product. A fully integrated run designed to test microfluidic control successfully generated CE‐ready STR amplicons in less than 2 h (<1 h of hands‐on time). Using this approach, high‐quality STR profiles were developed that were consistent with those produced using conventional DNA purification and STR amplification methods. This method is a smaller, more elegant solution than current microdevice methods and offers a cheaper, hands‐free, closed‐system alternative to traditional forensic methods.  相似文献   

3.
A flexible skin‐mounted microfluidic potentiometric device for simultaneous electrochemical monitoring of sodium and potassium in sweat is presented. The wearable device allows efficient natural sweat pumping to the potentiometric detection chamber, containing solid‐contact ion‐selective Na+ and K+ electrodes, during exercise activity. The fabricated microchip electrolyte‐sensing device displays good analytical performance and addresses sweat mixing and carry‐over issues of early epidermal potentiometric sensors. Such soft skin‐worn microchip platform integrates potentiometric measurement, microfluidic technologies with flexible electronics for real‐time wireless data transmission to mobile devices. The new fully integrated microfluidic electrolyte‐detection device paves the way for practical fitness and health monitoring applications.  相似文献   

4.
A simple and facile method for sensing of nucleic acids is in great need for disease biomarker detection and diagnosis. Herein, a fluorescent nanosensor utilizing carbon dot nanoparticles is introduced that form visible precipitates in the presence of target DNA. Carbon dot nanoparticles are fabricated by microwave pyrolysis of polyethylenimine, which emits strong photoluminescence and can form precipitates when added to target DNA oligonucleotides. The precipitates can be easily visualized by UV illumination, and data can be acquired as images using a smartphone, which are analyzed for quantification. This carbon‐dot‐based assay allowed fluorescent sensing of target oligonucleotides with various sizes and visualization even with minimal amount of DNA (≈100 pmol). Finally, the assay can be applied as a nanosensor platform for detecting bacterial DNA for the antibiotic‐resistance gene KPC‐2 from Klebsiella pneumoniae . This method provides a simple technique for detecting molecular targets, showing wide applicability for diagnostics on the bedside or point‐of‐care testing.  相似文献   

5.
In the presence of methanol and n‐decanol as porogens, a partially filled capillary monolithic column was prepared by in situ reaction of glycidyl methacrylate and poly (ethylene glycol) diacrylate. Then, Pharmalyte 3–10 was immobilized on this column in order to obtain a capillary isoelectric focusing (cIEF) column with monolithic immobilized pH gradient (M‐IPG). In addition, an online self‐built platform for protein separation was established on account of the introduction of a cross‐shaped unit and two short‐off valves. In this platform, a cross‐shaped unit was not only used to join the M‐IPG column and a six‐way injection valve (1.5 μL sample loop), but also to supply a volume pool of anode buffer so that the process of injection, focusing and mobilization of samples could be sequentially performed. The short‐off valve in the tee unit or cross‐shaped unit could be used to control the direction of the fluid flow. Using this online cIEF platform and under the optimized conditions, 7‐proteins mixture could be separated and a good linear correlation between pI values and migration times was obtained by the M‐IPG column. Meanwhile, based on the online cIEF platform, human serum proteins and a mixture of Hb A and Hb A1c have been successfully resolved with the newly developed M‐IPG column.  相似文献   

6.
Trends towards portable analytical instrumentation of the last decades have not been equally reflected in developments of portable liquid chromatography (LC) instrumentation for rapid on-site measurements. A miniaturised medium pressure capillary LC (MPLC) system with gradient elution capability has been designed based on a flexible modular microfluidic system using primarily off-the-shelf low cost components to ensure wide accessibility to other analysts. The microfluidic platform was assembled on a breadboard and contained microsyringe pumps and switch valves, complemented with an injection valve and on-capillary detectors, all controlled by a PC. Four miniaturised microsyringe pumps, with 5, 20 and 100 μL syringe volume options, formed the basis of the pumping system. Two pairs of pumps were used for each mobile phase to create gradient elution capability. The two microsyringe pumps in each pairs were linked by two electrically operated microfluidic switching valves and both pairs of pumps were connected through a zero void volume cross-connector, thus providing a low hold-up volume for gradient formation. Sample was injected by a 20 nL nano-LC sampling valve, directly connected to a 18 cm long 100 μm i.d. Chromolith CapRod RP-18 monolithic capillary column. On-capillary LED-based UV–vis photometric detection was conducted through a piece of equal diameter fused silica capillary connected after the column. The performance of the portable LC system was evaluated theoretically and experimentally, including the maximum operating pressure, gradient mixing performance, and the performance of the detectors. The 5 μL microsyringe pump offered the best performance, with typical maximum operating pressures up to 11.4 ± 0.4 MPa (water) and gradient pumping repeatability of between 4 and 9% for gradients between 0.10% s−1 and 0.33% s−1. Test analytes of charged and uncharged dyes and pharmaceuticals of varying hydrophobicity showed typical RSD values of 0.7–1.4% and 3.3–4.8% in isocratic mode and 1.2–4.6% and 3.2–6.4% in gradient mode, respectively for retention time and peak area repeatability.  相似文献   

7.
We use direct femtosecond laser writing to integrate optical waveguides into a commercial fused silica capillary electrophoresis chip. High-quality waveguides crossing the microfluidic channels are fabricated and used to optically address, with high spatial selectivity, their content. Fluorescence from the optically excited volume is efficiently collected at a 90° angle by a high numerical aperture fiber, resulting in a highly compact and portable device. To test the platform we performed electrophoresis and detection of a 23-mer oligonucleotide plug. Our approach is quite powerful because it allows the integration of photonic functionalities, by simple post-processing, into commercial LOCs fabricated with standard techniques. Figure Femtosecond laser written waveguides can selectively excite fluorescence in a microfluidic channel of a commercial lab-on-a-chip. A compact scheme for on-chip detection by laser induced fluorescence is applied to capillary electrophoresis of a 23-mer Cy3-labeled oligonucleotide  相似文献   

8.
Microfluidic chips combined with surface-enhanced Raman spectroscopy (SERS) offer an outstanding platform for rapid and high-sensitivity chemical analysis. However, it is nontrivial to conveniently form nanoparticle aggregrates (as SERS-active spots for SERS detection) in microchannels in a well-controlled manner. Here, we present a rapid, highly sensitive and label-free analytical technique for determining bovine serum albumin (BSA) on a poly(dimethylsiloxane) (PDMS) microfluidic chip using SERS. A modified PDMS pneumatic valve and nanopost arrays at the bottom of the fluidic microchannel are used for reversibly trapping gold nanoparticles to form gold aggregates, creating SERS-active spots for Raman detection. We fabricated a chip that consisted of a T-shaped fluidic channel and two modified pneumatic valves, which was suitable for fast loading of samples. Quantitative analysis of BSA is demonstrated with the measured peak intensity at 1,615 cm−1 in the surface-enhanced Raman spectra. With our microfluidic chip, the detection limit of Raman can reach as low as the picomolar level, comparable to that of normal mass spectrometry.  相似文献   

9.
《中国化学快报》2023,34(8):108059
Rapid detection of foodborne pathogens is crucial to prevent the outbreaks of foodborne diseases. In this work, we proposed a novel microfluidic biosensor based on magnetorheological elastomer (MRE) and smartphone. First, micropump and microvalves were constructed by deforming the MRE under magnetic actuation and integrated into the microfluidic biosensor for fluidic control. Then, the micropump was used to deliver immune porous gold@platinum nanocatalysts (Au@PtNCs), bacterial sample, and immunomagnetic nanoparticles (MNPs) into a micromixer, where they were mixed, incubated and magnetically separated to obtain the Au@PtNC-bacteria-MNP complexes. After 3,3′,5,5′-tetramethylbenzidine and hydrogen peroxide were injected and catalyzed by the Au@PtNCs, smartphone was used to measure the color of the catalysate for quantitative analysis of target bacteria. Under optimal conditions, this biosensor could detect Salmonella typhimurium quantitatively and automatically in 1 h with a linear detection range of 8.0 × 101 CFU/mL to 8.0 × 104 CFU/mL and a detection limit of 62 CFU/mL. The microfluidic biosensor was compact in size, simple to use, and efficient for detection, and might be used for in-field screening of foodborne pathogens to prevent food poisoning.  相似文献   

10.
The manufacture of three‐dimensional patterned electroactive poly(vinylidene fluoride‐co‐chlorotrifluoroethylene) microstructures with tailored architecture, morphology, and wettability is presented. The patterned microstructures are fabricated using a simple, effective, low cost, and reproducible technique based on microfluidic technology. These novel structures can represent innovative platforms for advanced strategies in a wide range of biotechnological applications, including tissue engineering, drug delivery, microfluidic, and sensors and actuators devices. © 2016 Wiley Periodicals, Inc. J. Polym. Sci., Part B: Polym. Phys. 2016 , 54, 1802–1810  相似文献   

11.
C. elegans is a popular model organism with a well‐developed neural network. Approximately 60% of the genes in C. elegans have genomic counterparts in humans, including those involved in building neural circuits. Therefore, we can extend the study of human neural network mechanisms to C. elegans which is easy to genetically manipulate. C. elegans shows behavioural responses to various external physical and chemical stimuli. Electrotaxis is one of its distinct behavioural responses, which is defined as movement towards the cathode in an electric field. In this study, we developed an effective microfluidic trap system for analysing electrotaxis in C. elegans. In addition, two mutant strains (unc‐54(s74) and unc‐6(e78)) from wild‐type (N2) worms were screened using the system. Wild‐type (N2) worms and the two mutant strains clearly showed different behavioural responses to the applied electric field, thus enabling the effective screening of the mutant worms from the wild type (N2). This microfluidic system can be utilized as a platform for the study of behavioural responses, and for the sorting and mutant screening of C. elegans.  相似文献   

12.
ABSTRACT

The main goal of this research communication focuses on screening of chromatographic behavior of 18 colorants including amaranth, black PN, bromophenol blue, bromocresol green, bromocresol purple, bromothymol blue, carmine, dimethyl yellow, erythrosine, fluorescein, methyl red, naphthalene black, patent blue, phenol red, Sudan II, Sudan III, Sudan IV, and p-xylenol blue. They are commonly used as food and industrial colorants or sensing molecules for analytical and biomedical applications. We studied retention (RF), peak base width (Wb), and peak asymmetry factor (AS) data collected under thermostatic conditions (303?K) using silica and cellulose-coated microplates (5?×?5?cm) and simple as possible mono/binary eluents. Presented retention database may help to select the proper conditions for, for example, chromatographic separation, extraction to solid phase (e.g. bar-type extraction devices) or application of such chemicals as the internal standard substances for planar/column chromatography and/or microfluidic devices (e.g., microfluidic paper-based analytical devices—μPADs). Furthermore, the microplates peak capacity (maximum number of resolvable spots, n) was calculated and discussed. As the second goal, we presented results of literature concerning dyes quantification in complex samples. We compared latest methodologies involving simple spectrophotometric analysis and more sophisticated protocols like high-throughput separation/detection procedures based on high-performance planar/liquid chromatography, capillary electrophoresis and microfluidic devices.  相似文献   

13.
In this report, a graphene/poly(ethylene‐co‐vinyl acetate) composite electrode was fabricated by melt compounding for the amperometric detection of capillary electrophoresis. The composite electrode was fabricated by packing a mixture of graphene and melted poly(ethylene‐co‐vinyl acetate) in a piece of fused silica capillary under heat. The structure of the composite was investigated by scanning electron microscopy and Fourier transform infrared spectroscopy. The results indicated that graphene sheets were well dispersed in the composite to form an interconnected conducting network. The performance of this unique graphene‐based detector has been demonstrated by separating and detecting rutin, quercitrin, kaempferol, and quercetin in Cacumen platycladi in combination with capillary electrophoresis. The four flavones have been well separated within 9 min in a 50‐cm‐long capillary at a separation voltage of 12 kV using a 50 mM sodium borate buffer (pH 9.2). The graphene‐based detector offered significantly lower operating potentials, substantially enhanced signal‐to‐noise characteristics, lower expense of operation, high resistance to surface fouling, and enhanced stability. It showed long‐term stability and repeatability with relative standard deviations of <5% for the peak current (n = 15).  相似文献   

14.
Huang CJ  Lin JL  Chen PH  Syu MJ  Lee GB 《Electrophoresis》2011,32(8):931-938
This study presents a new microfluidic system capable of precise measurements of two important biomarkers, urea and creatinine, automatically. In clinical applications, high levels of these two biomarkers are early indicators of nephropathy or renal failure and should be monitored on a regular basis. The microfluidic system is composed of a microfluidic chip, a control circuit system, a compressed air source and several electromagnetic valves to form a handheld system. The microfluidic chip is fabricated by using micro-electromechanical systems and microfluidic techniques comprising electrochemical sensor arrays and polydimethylsiloxane-based microfluidic structures such as micropumps/micromixers, normally closed valves and microchannels. The microfluidic system performs a variety of critical processes including sample pretreatment, mixing, transportation and detection on a single chip. The experimental results show that the entire procedure takes approximately 40 min, which is much faster than the traditional method (more than 6 h). Furthermore, the total sample volume consumed in each operation is only 0.1 mL, which is significantly less than that required in a large system (5 mL). The developed automatic microfluidic system may provide a powerful platform for further clinical applications.  相似文献   

15.
《Electrophoresis》2018,39(17):2236-2245
In this study, a metal‐organic framework (MOF), [Mn(cam)(bpy)], was synthesized and characterized by thermogravimetric analysis, scanning electron microscopy, and Fourier transform infrared spectrometry. An open‐tubular capillary column was fabricated from [Mn(cam)(bpy)] via the amide coupling method. Ten types of sulfonamides were separated through the fabricated capillary column, which showed a good limits of detection (<0.07 μg/mL) and linear ranges (1–100 or 5–100 μg/mL) with a high correlation coefficients (R2 > 0.9987). The intra‐day, inter‐day and column‐to‐column relative standard deviations (RSDs) in the migration times ranged from 0.44 to 4.87%, and the peak area RSDs ranged from 0.80 to 7.28%. The developed capillary electrochromatography method can be successfully utilized for the determination of sulfonamides in tap water and milk samples.  相似文献   

16.
基于微流控芯片试样引入技术的研究是目前微流控芯片分析领域内的重要研究方向之一,其目的是实现宏观外部系统(进行10^-6~1L级液体的操作)与芯片系统(进行10^-12~10^-9 L级液体的操作)的衔接(world-to-chip interfacing).目前文献报道的微流控分析系统,包括芯片流动注射系统,  相似文献   

17.
Totally porous lipid‐based liquid crystalline nanoparticles were used as pseudostationary phase for capillary electroseparation with LIF detection of proteins at physiological conditions using unmodified cyclic olefin copolymer capillaries (Topas®, 6.7 cm effective length). In the absence of nanoparticles, i.e. in CE mode, the protein samples adsorbed completely to the capillary walls and could not be recovered. In contrast, nanoparticle‐based capillary electroseparation resolved green fluorescent protein from several of its impurities within 1 min. Furthermore, a mixture of native green fluorescent protein and two of its single‐amino‐acid‐substituted variants was separated within 2.5 min with efficiencies of 400 000 plates/m. The nanoparticles prevent adsorption by introducing a large interacting surface and by obstructing the attachment of the protein to the capillary wall. A one‐step procedure based on self‐assembly of lipids was used to prepare the nanoparticles, which benefit from their biocompatibility and suspension stability at high concentrations. An aqueous tricine buffer at pH 7.5 containing lipid‐based nanoparticles (2% w/w) was used as electrolyte, enabling separation at protein friendly conditions. The developed capillary‐based method facilitates future electrochromatography of proteins on polymer‐based microchips under physiological conditions and enables the initial optimization of separation conditions in parallel to the chip development.  相似文献   

18.
Pepsin‐modified affinity monolithic capillary electrochromatography, a novel microanalysis system, was developed by the covalent bonding of pepsin on silica monolith. The column was successfully applied in the chiral separation of (±)‐nefopam. Furthermore, the electrochromatographic performance of the pepsin‐functionalized monolith for enantiomeric analysis was evaluated in terms of protein content, pH of running buffer, sample volume, buffer concentration, applied voltage, and capillary temperature. The relative standard deviation (%RSD) values of retention time (intraday <0.53, n = 10; interday <0.53, n = 10; column‐to‐column <0.70, n = 20; and batch‐to‐batch <0.80, n = 20) indicated satisfactory stability of these columns. No appreciable change was observed in retention and resolution for chiral recognition of (±)‐nefopam in 50 days with 100 injections. The proteolytic activity of this stationary phase was further characterized with bovine serum albumin as substrate for online protein digestion. As for monolithic immobilized enzyme reactor, successive protein injections confirmed both the operational stability and ability to reuse the bioreactor for at least 20 digestions. It implied that the affinity monolith used in this research opens a new path of exploring particularly versatile class of enzymes to develop enzyme‐modified affinity capillary monolith for enantioseparation.  相似文献   

19.
Ion‐selective electrodes (ISEs) are widely used tools for fast and accurate ion sensing. Herein their design is simplified by embedding a potentiometric cell into paper, complete with an ISE, a reference electrode, and a paper‐based microfluidic sample zone that offer the full function of a conventional ISE setup. The disposable planar paper‐based ion‐sensing platform is suitable for low‐cost point‐of‐care and in‐field testing applications. The design is symmetrical and each interfacial potential within the cell is well defined and reproducible, so that the response of the device can be theoretically predicted. For a demonstration of clinical applications, paper‐based Cl? and K+ sensors are fabricated with highly reproducible and linear responses towards different concentrations of analyte ions in aqueous and biological samples. The single‐use devices can be fabricated by a scalable method, do not need any pretreatment prior to use, and only require a sample volume of 20 μL.  相似文献   

20.
Spatial microgravity is a significant factor affecting and causing physiological changes of organisms in space environment. On‐site assessment of the damage associated to microgravity is very important for future long‐term space exploration of mankind. In this paper, a new microfluidic device for analyzing the damage of microgravity on Caenorhabditis elegans (C. elegans) has been developed. This device is mainly composed of a microfluidic chip, a dual imaging module, and an imaging acquisition and processing module, which are integrated into a compact system. The microfluidic chip is designed as a platform for monitoring C. elegans, which is captured in an imaging region through a suction structure in the microfluidic chip. A dual imaging module is designed to obtain the images of bright field and fluorescence of C. elegans. The behaviors of C. elegans are analyzed based on the dual‐mode imaging of bright field and fluorescence to assess the degree of damage due to microgravity. A comparative study using a commercial microscope is also conducted to demonstrate the unique advantage of the developed system under the simulated microgravity. The results show that the developed system can evaluate the damage of C. elegans under microgravity accurately and conveniently. Furthermore, this device has compact size and weight, easy operation, and low‐cost, which could be highly advantageous for on‐site evaluation of the damage to microorganisms under microgravity in a space station.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号