首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Analysis of pesticide residues in water and food matrices is an active research area closely related to food safety and environmental issues. In this aspect mass spectrometry (MS) coupled to gas chromatography (GC) and liquid chromatography (LC) has been increasingly used in the analysis of pesticide residues in water and food. The increasing interest in application of high‐resolution mass spectrometry with time‐of‐flight (TOF) and hybrid triple quadrupole TOF in pesticide analysis is due to its capability of performing both targeted and nontargeted analysis. This article discusses an overview of the application of GC‐TOF‐MS and LC‐TOF‐MS in water and food matrices.  相似文献   

2.
Gas chromatography–high-resolution mass spectrometry (GC–HRMS) is a powerful nontargeted screening technique that promises to accelerate the identification of environmental pollutants. Currently, most GC–HRMS instruments are equipped with electron ionization (EI), but atmospheric pressure ionization (API) ion sources have attracted renewed interest because: (i) collisional cooling at atmospheric pressure minimizes fragmentation, resulting in an increased yield of molecular ions for elemental composition determination and improved detection limits; (ii) a wide range of sophisticated tandem (ion mobility) mass spectrometers can be easily adapted for operation with GC–API; and (iii) the conditions of an atmospheric pressure ion source can promote structure diagnostic ion–molecule reactions that are otherwise difficult to perform using conventional GC–MS instrumentation. This literature review addresses the merits of GC–API for nontargeted screening while summarizing recent applications using various GC–API techniques. One perceived drawback of GC–API is the paucity of spectral libraries that can be used to guide structure elucidation. Herein, novel data acquisition, deconvolution and spectral prediction tools will be reviewed. With continued development, it is anticipated that API may eventually supplant EI as the de facto GC–MS ion source used to identify unknowns.  相似文献   

3.
The potential of three mass spectrometry (MS) analyzers (triple quadrupole, QqQ; time of flight, TOF; and quadrupole time of flight, QTOF) has been investigated and compared for quantification, confirmation and screening purposes in pesticide residue analysis of fruit and vegetable samples. For this purpose, analytical methodology for multiresidue determination of 11 pesticides, taken as a model, has been developed and validated in nine food matrices for the three mass analyzers coupled to ultra high pressure liquid chromatography. In all cases, limits of quantification around 0.01 mg/kg were reached, fulfilling the most restrictive case of baby‐food analysis. Regarding absolute sensitivity, the lower limits of detection were obtained, as expected, for QqQ (100 fg), whereas slightly higher limits (300 fg) were obtained for both TOF and QTOF. Confirmative capacity of each analyzer was studied for each analyte based on the identification points (IPs) criterion, useful for a comprehensive comparison. QTOF mass analyzer showed the highest confirmatory capacity, although QqQ normally led to sufficient number of IPs, even at lower concentration levels. The potential of TOF MS was also investigated for screening purposes. To this aim, around 50 commercial fruits and vegetables samples were analyzed, searching for more than 400 pesticides. TOF MS proved to be an attractive analytical tool for rapid detection and reliable identification of a large number of pesticides thanks to the full spectrum acquisition at accurate mass with satisfactory sensitivity. This process is readily boosted when combined with specialized software packages, together with theoretical exact mass databases. Several pesticides (e.g. carbendazim in citrus and indoxacarb in grape) were detected in the samples. Further unequivocal confirmation of the identity was performed using reference standards and/or QTOF MS/MS experiments. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

4.
This work presents a strategy for elucidation of unknown migrants from plastic food contact materials (baby bottles) using a combination of analytical techniques in an untargeted approach. First, gas chromatography (GC) coupled to mass spectrometry (MS) in electron ionisation mode was used to identify migrants through spectral library matching. When no acceptable match was obtained, a second analysis by GC‐(electron ionisation) high resolution mass spectrometry time of flight (TOF) was applied to obtain accurate mass fragmentation spectra and isotopic patterns. Databases were then searched to find a possible elemental composition for the unknown compounds. Finally, a GC hybrid quadrupole‐TOF‐MS with an atmospheric pressure chemical ionisation source was used to obtain the molecular ion or the protonated molecule. Accurate mass data also provided additional information on the fragmentation behaviour as two acquisition functions with different collision energies were available (MSE approach). In the low‐energy function, limited fragmentation took place, whereas for the high‐energy function, fragmentation was enhanced. For less volatile unknowns, ultra‐high pressure liquid chromatography‐quadrupole‐TOF‐MS was additionally applied. Using a home‐made database containing common migrating compounds and plastic additives, tentative identification was made for several positive findings based on accurate mass of the (de)protonated molecule, product ion fragments and characteristic isotopic ions. Six illustrative examples are shown to demonstrate the modus operandi and the difficulties encountered during identification. The combination of these techniques was proven to be a powerful tool for the elucidation of unknown migrating compounds from plastic baby bottles. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

5.
Orthogonal acceleration time‐of‐flight (oa‐TOF) mass spectrometry (MS) was coupled to gas chromatography (GC) to measure ion yields (ratio of ion counts to number of neutrals entering the ion source) and signal‐to‐noise (S/N) in the electron ionization (EI) mode (hard ionization) as well as in the soft ionization modes of chemical ionization (CI), electron capture negative ion chemical ionization (NICI) and field ionization (FI). Mass accuracies of the EI and FI modes were also investigated. Sixteen structurally diverse volatile organic compounds were chosen for this study. The oa‐TOF mass analyzer is highly suited for FI MS and provided an opportunity to compare the sensitivity of this ionization method to the more conventional ionization methods. Compared to the widely used quadrupole mass filter, the oa‐TOF platform offers significantly greater mass accuracy and therefore the possibility of determining the empirical formula of analytes. The findings of this study showed that, for the instrument used, EI generated the most ions with the exception of compounds able to form negative ions readily. Lower ion yields in the FI mode were generally observed but the chromatograms displayed greater S/N and in many cases gave spectra dominated by a molecular ion. Ion counts in CI are limited by the very small apertures required to maintain sufficiently high pressures in the ionization chamber. Mass accuracy for molecular and fragment ions was attainable at close to manufacturer's specifications, thus providing useful information on molecular ions and neutral losses. The data presented also suggests a potentially useful instrumental combination would result if EI and FI spectra could be collected simultaneously or in alternate scans during GC/MS. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

6.
Herbal formulations are complex natural mixtures. Researchers usually tend to focus more on analysis of nonvolatile components but pay less attention to volatile compounds. In this study, an analytical strategy combining two approaches was established for comprehensive analysis of herbal formulations. Guizhi Fuling capsule (GFC), a drug approved by the FDA to enter phase II clinical trial for treatment of primary dysmenorrhea, was taken as a case for analysis. Gas chromatography–mass spectrometry (GC‐MS) with automated mass spectral deconvolution and identification system (AMDIS) led to rapid identification of 48 volatile components including four acetophenones, three fatty acid esters, 13 phenylpropanoids and 19 sesquiterpenes. Most of them were found from Guizhi. The volatile oils of Guizhi have been proved to exhibit many pharmacological activities. This is helpful in understanding the pharmacological mechanism of GFC. Furthermore, AMDIS turned out to be efficient and reliable for analysis of complex herbal formulations. Rapid‐resolution liquid chromatography (RRLC) coupled with electrospray ionization quadrupole time‐of‐flight tandem mass spectrometry (ESI‐Q‐TOF MS/MS) allowed the identification of 70 nonvolatile components including six acetophenones, 12 galloyl glucoses, 31 monoterpene glycosides, three phenols and 12 triterpene acids. Fragmentation behaviors of assigned components, especially triterpene acids, which are hard to identify by low‐resolution MS, were first investigated by TOF MS/MS. Characteristic ions and typical loss of assigned triterpene acids were summarized. Combinatorial use of GC‐MS‐AMDIS and RRLC‐ESI‐Q‐TOF MS/MS could be of great help in global qualitative analysis of GFC, as well as other herbal products. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

7.
8.
The potential of gas chromatography coupled to tandem mass spectrometry (GC/MS/MS) with a triple quadrupole analyzer (QqQ) has been investigated for the quantification and reliable identification of sixteen polycyclic aromatic hydrocarbons (PAHs) from the EPA priority list in animal and vegetable samples from aquaculture activities, whose fat content ranged from 5 to 100%. Matrices analyzed included fish fillet, fish feed, fish oil and linseed oil. Combining optimized saponification and solid‐phase extraction led to high efficiency in the elimination of interfering compounds, mainly fat, from the extracts. The developed procedure minimized the presence of these interfering compounds in the extracts and provided satisfactory recoveries of PAHs. The excellent sensitivity and selectivity of GC/(QqQ)MS/MS in selected reaction monitoring (SRM) allowed to reach limits of detection at pg/g levels. Two SRM transitions were acquired for each analyte to ensure reliable identification of compounds detected in samples. Confirmation of positive findings was performed by GC coupled to high‐resolution time‐of‐flight mass spectrometry (GC/TOFMS). The accurate mass information provided by GC/TOFMS in full acquisition mode together with its high mass resolution makes it a powerful analytical tool for the unequivocal confirmation of PAHs in the matrices tested. The method developed was applied to the analysis of real‐world samples of each matrix studied with the result of detecting and confirming the majority of analytes at the µg/kg level by both QqQ and TOF mass spectrometers. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

9.
Direct Analysis in Real Time (DART) is an ambient ionization technique for mass spectrometry that provides rapid and sensitive analyses with little or no sample preparation. DART has been reported primarily for mass analyzers of low to moderate resolving power such as quadrupole ion traps and time‐of‐flight (TOF) mass spectrometers. In the current work, a custom‐built DART source has been successfully coupled to two different Fourier transform ion cyclotron resonance (FT‐ICR) mass spectrometers for the first time. Comparison of spectra of the isobaric compounds, diisopropyl methylphosphonate and theophylline, acquired by 4.7 T FT‐ICR MS and TOF MS, demonstrates that the TOF resolving power can be insufficient for compositionally complex samples. 9.4 T FT‐ICR MS yielded the highest mass resolving power yet reported with DART ionization for 1,2‐benzanthracene and 9,10‐diphenylanthracene. Polycyclic aromatic hydrocarbons exhibit a spatial dependence in ionization mechanisms between the DART source and the mass spectrometer. The feasibility of analyzing a variety of samples was established with the introduction and analysis of food products and crude oil samples. DART FT‐ICR MS provides complex sample analysis that is rapid, highly selective and information‐rich, but limited to relatively low‐mass analytes. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

10.
In order to have overall chemical material information of Kai‐Xin‐San (KXS), the reliable ultra‐high‐performance liquid chromatography quadrupole time‐of‐flight mass spectrometer (UHPLC–Q‐TOF‐MS) and ultra‐fast liquid chromatography mass spectrometer (UFLC‐MS/MS) methods were developed for the identification and determination of the major constituents in KXS. Moreover, the UHPLC–Q‐TOF‐MS method was also applied to screen for multiple absorbed components in rat plasma after oral administration of KXS. The UHPLC–Q‐TOF‐MS method was achieved on Agilent 6520 Q‐TOF mass and operated in the negative ion mode. Good separation was performed on a ZORBAX Eclipse Plus C18 column with a gradient elution at a flow rate of 0.2 ml/min. A total of 92 compounds in KXS were identified or tentatively characterized based on their exact molecular weights, fragmentation patterns, and literature data. A total of 26 compounds including 23 prototype components and three metabolites were identified in rat plasma after oral administration of KXS. Then, 16 major bioactive constituents were chosen as the benchmark substances to evaluate the quality of KXS. Their quantitative analyses were performed by a triple quadrupole tandem mass spectrometer (MS/MS) operating in multiple‐reaction monitoring mode(MRM). The analysis was completed with a gradient elution at a flow rate of 0.4 ml/min within 35 min. The simple and fast method was validated and showed good linearity, precision, and recovery. Furthermore, the method was successful applied for the determination of 16 compounds in KXS. All results would provide essential data for identification and quality control of active chemical constituents in KXS. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

11.
Wu Wei Zi (Schisandra chinensis), an important herbal medicine, is mainly distributed in the northeast of China. Its phytochemical compositions, which depend on geographical origin, climatic conditions and cultural practices, may vary largely among Wu Wei Zi from different areas. In this study, we applied a comprehensive metabolite profiling approach using GC–TOF‐MS, ultra‐performance LC (UPLC) quadrupole TOF (QTOF) MS and inductively coupled plasma MS to systematically investigate the metabolite variations of S. chinensis from four different areas including Heilongjiang, Liaoning, Jilin, and Shanxi of China. A total of 65 primary metabolites, 35 secondary metabolites and 64 inorganic elements were identified. Several primary metabolites, including shikimic acid and tricarboxylic acid cycle intermediates, were abundant in those located in Heilongjiang, Jilin, and Liaoning. Besides, bioactive lignans are also highly abundant in those from northeastern China than those from northwestern China. Inorganic elements varied significantly among the different locations. Our results suggested that the metabolite profiling approach using GC–TOF‐MS, ultra‐performance LC quadrupole TOF MS, and inductively coupled plasma MS is a robust and reliable method that can be effectively used to explore subtle variations among plants from different geographical locations.  相似文献   

12.
An API 3000 triple-quadrupole instrument and a QSTAR Pulsar quadrupole time-of-flight (TOF) mass spectrometer were compared for the determination of phosphopeptides by precursor ion scanning in both the positive and negative nanoelectrospray ionization modes. The limits of detection for synthetic phosphopeptides were similar (500 amol microl(-1)) for both types of instruments when monitoring precursors of -79 Da (PO(3)(-)). However, the quadrupole TOF system was approximately fivefold more sensitive (1 fmol microl(-1)) than the triple-quadrupole instrument (5 fmol microl(-1)) when monitoring precursors of 216 Da (immonium ion of phosphotyrosine). The recently introduced Q(2)-pulsing function, which enhances the transmission of fragment ions of a selected m/z window from the collision cell into the TOF part, improved the sensitivity of precursor ion scans on a quadrupole TOF instrument. The selectivity of precursor ion scans is much better on quadrupole TOF systems than on triple quadrupoles because the high resolving power of the reflectron-TOF mass analyzer permits high-accuracy fragment ion selection at no expense of sensitivity. This minimizes interferences from other peptide fragment ions (a-, b-, and y- type) of the same nominal mass but with sufficient differences in their exact masses. As a result, the characteristic immonium ion of phosphotyrosine at m/z 216.043 can be utilized for the selective detection of tyrosine phosphorylated peptides. Our data suggest that, in addition to their superior performance for peptide sequencing, quadrupole TOF instruments also offer a very viable alternative to triple quadrupoles for precursor ion scanning, thus combining high sensitivity and selectivity for both MS and MS/MS experiments in one instrument.  相似文献   

13.
On‐line ultra‐performance liquid chromatography (UPLC) coupled with diode‐array detection (UPLC/DAD) and electrospray ionization quadrupole time‐of‐flight mass spectrometry (ESI‐Q‐TOF‐MS) were used for separation, identification and structural analyses of saponins in Rhizoma Paridis saponins (RPS) and rat plasma after oral administration of RPS. Thirty steroidal saponins in RPS were identified by comparing their retention time, accurate mass measurement and positive and negative mass spectrometry data with that of reference compounds. The UPLC/Q‐TOF‐MS method was proved to be rapid and efficient in that 30 steroidal saponins, including three kinds of saponins (prototype, pennogenyl and diosgenyl saponins) were tentatively characterized within 6 min. After oral administration of RPS, 21 original saponins were absorbed in RPS‐treated rat plasma. Our results indicated that UPLC/Q‐TOF‐MS is a rapid and effective tool for identification of a series of saponins at trace level. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

14.
Acorus tatarinowii Schott (ATS) is a well‐known traditional Chinese medicine (TCM) for the treatment of epilepsy, amnesia and insomnia. In this study, a methodology utilizing high‐performance liquid chromatography (HPLC) coupled with electrospray ionization quadrupole time‐of‐flight mass spectrometry (ESI‐QTOF‐MS/MS) was established for the separation and structural identification of the major chemical constituents in ATS for the first time. Overall, 46 major constituents including flavonoid glycosides, phenylpropane derivatives, amides and lignans were identified or tentatively characterized. Seven major constituents, including four phenylpropane derivatives and three lignans, were further quantified as marker substances, which showed good linearity within the test ranges. These results indicated that the developed quantitative method was linear, sensitive, and precise for quality control of ATS. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

15.
Metabolomics is a rapidly growing field in the comprehensive understanding of cellular and organism‐specific responses associated with perturbations induced by medicines, chemicals and environment. Blood matrices are frequently used in clinical and biological studies. In this study, we compared metabolic profiling between rat plasma and serum using complementary platforms of gas chromatography–mass spectrometry (GC‐MS) and liquid chromatography–quadruple time‐of‐flight–mass spectrometry (LC‐QTOF‐MS). The sample types that were tested included plasma prepared with K2EDTA and serum collected using venous blood collection protocols. The results of peak area variation for each detected metabolite/feature in the quality control samples showed a good reproducibility in LC‐QTOF‐MS and better reproducibility in GC‐MS. In GC‐MS analysis: (a) 25.8% of the defined metabolites differed serum from plasma profiling (t‐test, p < 0.05); and (b) serum possessed higher sensitivity than plasma for its generally higher peak intensity in the metabolic profiling. In LC‐QTOF‐MS analysis, 13 (in positive ion mode) and seven (in negative ion mode) important metabolites were identified as mainly contributing to the separation between serum and plasma. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

16.
Zhang Y  Tobias HJ  Brenna JT 《The Analyst》2012,137(13):3102-3110
Comprehensive two dimensional gas chromatography (GC × GC) provides greater separation space than conventional GC. Because of fast peak elution, a time of flight mass spectrometer (TOFMS) is the usual structure-specific detector of choice. The quantitative capabilities of a novel GC × GC fast quadrupole MS were investigated with electron ionization (EI), and CH(4) or NH(3) positive chemical ionization (PCI) for analysis of endogenous urinary steroids targeted in anti-doping tests. Average precisions for steroid quantitative analysis from replicate urine extractions were 6% (RSD) for EI and 8% for PCI-NH(3). The average limits of detection (LODs) calculated by quantification ions for 12 target steroids spiked into steroid-free urine matrix (SFUM) were 2.6 ng mL(-1) for EI, 1.3 ng mL(-1) for PCI-CH(4), and 0.3 ng mL(-1) for PCI-NH(3), all in mass scanning mode. The measured limits of quantification (LOQs) with full mass scan GC × GC-qMS were comparable with the LOQ values measured by one-dimensional GC-MS in selected ion monitoring (SIM) mode. PCI-NH(3) yields fewer fragments and greater (pseudo)molecular ion abundances than EI or PCI-CH(4). These data show that a benchtop GC × GC-qMS system has the sensitivity, specificity, and resolution to analyze urinary steroids at normal urine concentrations, and that PCI-NH(3), not currently available on most GC × GC-TOFMS instruments, is of particular value for generation of structure-specific ions.  相似文献   

17.
Metabolism studies play an important role at various stages of drug discovery and development. Liquid chromatography combined with mass spectrometry (LC/MS) has become a most powerful and widely used analytical tool for identifying drug metabolites. The suitability of different types of mass spectrometers for metabolite profiling differs widely, and therefore, the data quality and reliability of the results also depend on which instrumentation is used. As one of the latest LC/MS instrumentation designs, hybrid ion trap/time‐of‐flight MS coupled with LC (LC‐IT‐TOF‐MS) has successfully integrated ease of operation, compatibility with LC flow rates and data‐dependent MSn with high mass accuracy and mass resolving power. The MSn and accurate mass capabilities are routinely utilized to rapidly confirm the identification of expected metabolites or to elucidate the structures of uncommon or unexpected metabolites. These features make the LC‐IT‐TOF‐MS a very powerful analytical tool for metabolite identification. This paper begins with a brief introduction to some basic principles and main properties of a hybrid IT‐TOF instrument. Then, a general workflow for metabolite profiling using LC‐IT‐TOF‐MS, starting from sample collection and preparation to final identification of the metabolite structures, is discussed in detail. The data extraction and mining techniques to find and confirm metabolites are discussed and illustrated with some examples. This paper is directed to readers with no prior experience with LC‐IT‐TOF‐MS and will provide a broad understanding of the development and utility of this instrument for drug metabolism studies. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

18.
Pharmaceuticals require careful and precise determination of their impurities that might harm the user upon consumption. Although today, the most common technique for impurities identification is liquid chromatography‐mass spectrometry (LC‐MS/MS), it has several downsides due to the nature of the ionization method. Also, the analyses in many cases are targeted thus despite being present, some of the compounds will not be revealed. In this paper, we propose and show a new method for untargeted analysis and identification of impurities in active pharmaceutical ingredients (APIs). The instrument used for these analyses is a novel electron ionization (EI) LC‐MS with supersonic molecular beams (SMB). The EI‐LC‐MS‐SMB was implemented for analyses of several drug samples spiked with an impurity. The instrument provides EI mass spectra with enhanced molecular ions, named Cold EI, which increases the identification probabilities when the compound is identified with the aid of an EI library like National Institute of Standards and Technology (NIST). We analyzed ibuprofen and its impurities, and both the API and the expected impurity were identified with names and structures by the NIST library. Moreover, other unexpected impurities were found and identified proving the ability of the EI‐LC‐MS‐SMB system for truly untargeted analysis. The results show a broad dynamic range of four orders of magnitude at the same run with a signal‐to‐noise ratio of over 10 000 for the API and almost uniform response.  相似文献   

19.
The dimerization of alkanethiol mixtures (hexanethiol, octanethiol, and dodecanethiol) to form self‐assembled monolayers (SAMs) from headspace on nanoporous gold surfaces was studied for the first time using gas chromatography (GC/MS) and time‐of‐flight secondary ion mass spectrometry (TOF‐SIMS). The nanoporous gold surfaces were obtained by an acidic etching of a 585‐gold alloy. Field emission scanning electron microscopy (FE‐SEM) was utilized to study the change of the surface geometry and porosity of the gold surfaces before and after etching. Alkanethiols were deposited from the vapor phase above the thiol solutions (headspace) on nanoporous gold plates and nanoporous gold solid‐phase vmicroextraction (SPME) fibers. The nanoporous gold substrates were analyzed by TOF‐SIMS and GC/MS, respectively. The TOF‐SIMS spectra exhibited various gold–sulfur ion clusters and specific peaks related to the adsorption of thiols such as deprotonated monomers, thiolate–Au, dimers (e.g., dialkyl sulfides–Au and dialkyl disulfides–Au). The GC/MS analysis of headspace extractions of alkanethiol mixtures by nanoporous gold SPME fibers showed a high extraction efficiency of alkanethiol, dialkyl sulfide, and dialkyl disulfide when compared with the commercial SPME fibers (DVB‐CAR‐PDMS and CAR‐PDMS). Different GC/MS optimization factors were studied including the extraction time and desorption temperature.  相似文献   

20.
Like many new designer drugs of abuse, synthetic cannabinoids (SC) have structural or positional isomers which may or may not all be regulated under law. Differences in acute toxicity may exist between isomers which impose further burden in the fields of forensic toxicology, medicine and legislation. Isomer differentiation therefore becomes crucial from these standpoints as new designer drugs continuously emerge with just minor positional modifications to their preexisting analogs. The aim of this study was to differentiate the positional isomers of JWH‐081. Purchased standard compounds of JWH‐081 and its positional isomers were analyzed by gas chromatography‐electron ionization‐mass spectrometry (GC‐EI‐MS) first in scan mode to investigate those isomers who could be differentiated by EI scan spectra. Isomers with identical or near‐identical EI spectra were further subjected to GC‐tandem mass spectrometry (MS/MS) analysis with appropriate precursor ions. EI scan was able to distinguish 3 of the 7 isomers: 2‐methoxy, 7‐methoxy and 8‐methoxy. The remaining isomers exhibited near‐identical spectra; hence, MS/MS was performed by selecting m/z 185 and 157 as precursor ions. 3‐Methoxy and 5‐methoxy isomers produced characteristic product ions that enabled the differentiation between them. Product ion spectrum of 6‐methoxy isomer resembled that of JWH‐081; however, the relative ion intensities were clearly different from one another. The combination of EI scan and MS/MS allowed for the regioisomeric differentiation of the targeted compounds in this study. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   