首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Progress made in the last five years in the application of capillary electrophoresis methods to chemical speciation of elements is reported on the basis of over 100 literature references. The main trends observed include development of new on‐ and off‐capillary derivatization methods, application of new detection methods, and especially coupling of CE separation systems to powerful atomic spectroscopy and mass spectrometry instruments with various ionization techniques, providing either a sensitive element‐specific detection method or a third dimension for high performance separation. Besides numerous CZE and MEKC capillary electrophoresis methods only very few examples of CE speciation with capillary electrochromatography can be found. Concerning the chemical forms of elements determined, the new procedures developed are mostly focused on redox speciation of various oxidation states of elements, metal‐bound high molecular compounds, and organometallic species.  相似文献   

2.
A novel method for the preparation of covalently linked capillary coatings of poly(N‐vinyl aminobutyric acid) (PVAA) obtained from hydrolyzed polyvinylpyrrolidone was demonstrated using photosensitive diazoresin (DR) as a coupling agent. A layer‐by‐layer self‐assembled film of DR and PVAA based on ionic bonding was first fabricated on the inner wall of capillary, then ionic bonding was converted into covalent bonding after treatment with UV light through a unique photochemical reaction of DR. The covalently bonded coatings suppressed protein adsorption on the inner surface of the capillary, and thus a baseline separation of lysozyme, cytochrome c, BSA, amyloglucosidase, and myoglobin was achieved using CE. Compared with bare capillary or noncovalently bonded DR/PVAA coatings, the covalently linked DR/PVAA capillary coatings not only improved the CE separation performance for proteins, but also exhibited good stability and repeatability. Due to the replacement of the highly toxic and moisture‐sensitive silane coupling agent by DR in the covalent coating preparation, this method may provide a green and easy way to make covalently coated capillaries for CE.  相似文献   

3.
CE is gaining great popularity as a well‐established separation technique for many fields such as pharmaceutical research, clinical application, environmental monitoring, and food analysis, owing to its high resolving power, rapidity, and small amount of samples and reagents required. However, the sensitivity in CE analysis is still considered as being inferior to that in HPLC analysis. Diverse enrichment methods and techniques have been increasingly developed for overcoming this issue. In this review, we summarize the recent advances in enrichment techniques containing off‐line preconcentration (sample preparation) and on‐line concentration (sample stacking) to enhancing sensitivity in CE for trace analysis over the last 5 years. Some relatively new cleanup and preconcentration methods involving the use of dispersive liquid–liquid microextraction, supercritical fluid extraction, matrix solid‐phase dispersion, etc., and the continued use and improvement of conventional SPE, have been comprehensively reviewed and proved effective preconcentration alternatives for liquid, semisolid, and solid samples. As for CE on‐line stacking, we give an overview of field amplication, sweeping, pH regulation, and transient isotachophoresis, and the coupling of multiple modes. Moreover, some limitations and comparisons related to such methods/techniques are also discussed. Finally, the combined use of various enrichment techniques and some significant attempts are proposed to further promote analytical merits in CE.  相似文献   

4.
Open source paradigm is becoming widely accepted in scientific communities and open source hardware is finding its steady place in chemistry research. In this review article, we provide the reader with the most up‐to‐date information on open source hardware and software resources enabling the construction and utilization of an “open source capillary electrophoresis instrument”. While CE is still underused as a separation technique, it offers unique flexibility, low‐cost, and high efficiency and is particularly suitable for open source instrumental development. We overview the major parts of CE instruments, such as high voltage power supplies, detectors, data acquisition systems, and CE software resources with emphasis on availability of the open source information on the web and in the scientific literature. This review is the first of its kind, revealing accessible blueprints of most parts from which a fully functional open source CE system can be built. By collecting the extensive information on open source capillary electrophoresis in this review article, the authors aim at facilitating the dissemination of knowledge on CE within and outside the scientific community, fosters innovation and inspire other researchers to improve the shared CE blueprints.  相似文献   

5.
《Electroanalysis》2004,16(24):2009-2021
The popularity of contactless conductivity detection in capillary electrophoresis has been growing steadily over the last few years. Improvements have been made in the design of the detector in order to facilitate its handling, to allow easy incorporation into available instruments or to achieve higher sensitivity. The understanding of its fundamental working principles has been advanced and the detection approach has also been transferred to lab‐on‐chip devices. The range of applications has been extended greatly from the initial work on small inorganic ions to include organic species and biomolecules. Concurrent determination of cations and anions by dual injection from opposite ends has been demonstrated as well as sample introduction by using flow‐injection systems for easy automation of the process.  相似文献   

6.
mAbs are highly complex proteins that present a wide range of microheterogeneity that requires multiple analytical methods for full structure assessment and quality control. As a consequence, the characterization of mAbs on different levels is particularly product‐ and time‐consuming. CE‐MS couplings, especially to MALDI, appear really attractive methods for the characterization of biological samples. In this work, we report the last instrumental development and performance of the first totally automated off‐line CE‐UV/MALDI‐MS/MS. This interface is based on the removal of the original UV cell of the CE apparatus, modification of the spotting device geometry, and creation of an integrated delivery matrix system. The performance of the method was evaluated with separation of five intact proteins and a tryptic digest mixture of nine proteins. Intact protein application shows the acquisition of electropherograms with high resolution and high repeatability. In the peptide mapping approach, a total number of 154 unique identified peptides were characterized using MS/MS spectra corresponding to average sequence coverage of 64.1%. Comparison with NanoLC/MALDI‐MS/MS showed complementarity at the peptide level with an increase of 42% when using CE/MALDI‐MS coupling. Finally, this work represents the first analysis of intact mAb charge variants by CZE using an MS detection. Moreover, using a peptide mapping approach CE‐UV/MALDI‐MS/MS fragmentation allowed 100% sequence coverage of the light chain and 92% of the heavy chain, and the separation of four major glycosylated peptides and their structural characterization.  相似文献   

7.
Biopharmaceuticals (recombinant technology-based products, vaccines, whole blood and blood components, gene therapy, cells, tissues, etc.,) are described as biological medical products produced from various living sources such as human, microbial, animal, and so on by manufacturing, extraction, or semi-synthesis. They are complex molecules having high molecular weights. For their safety and efficacy, their structural, clinical, physicochemical, and chemical features must be carefully controlled, and they must be well characterized by analytical techniques before the approval of the final product. Capillary electrophoresis (CE) having versatile modes can provide valuable safety and efficacy information, such as amino acid sequence, size variants (low and high molecular weight variants), charged variants (acidic and basic impurities), aggregates, N-linked glycosylation, and O-linked glycosylation. There are numerous applications of CE in the literature. In this review, the most significant and recent studies on the analysis of recombinant DNA technology-based products using different CE modes in the last ten years have been overviewed. It was seen that the researches mostly focus on the analysis of mAbs and IgG. In addition, in recent years, researchers have started to prefer CE combined mass spectrometry (MS) techniques to provide a more detailed characterization for protein and peptide fragments.  相似文献   

8.
This study reports a reinvestigation of background electrolyte selection strategy for performance improvement in CE‐LIF of peptides and proteins. This strategy is based on the employment of high concentrations of organic species in BGE possessing high buffer capacity and low specific conductivity in order to ensure excellent stacking preconcentration and separation resolution of fluorescently tagged peptides and proteins. Unlike universal UV detection, the use of such BGEs at high concentrations does not lead to degradation of LIF detection signals at the working excitation and emission wavelengths. At the same buffer ionic strength, pH and electric field, an “inorganic‐species‐free” BGE (or ISF BGE) for CE‐LIF of fluorescently labeled beta amyloid peptide Aβ 1–42 (a model analyte) offered a signal intensity and peak efficiency at least three‐times higher than those obtained with a conventional BGE normally used for CE‐LIF, while producing an electric current twice lower. Good peak performance (in terms of height and shape) was maintained when using ISF BGEs even with samples prepared in high‐conductivity phosphate buffer saline matrix. The advantageous features of such BGEs used at high concentrations over conventional ones in terms of high separation resolution, improved signal intensities, tuning of EOF magnitudes and minimization of protein adsorption on an uncoated fused silica capillary are demonstrated using Alexa‐488‐labelled trypsin inhibitor. Such BGE selection approach was applied for investigation of separation performance for CE‐LIF of ovalbumin labelled with different fluorophores.  相似文献   

9.
Capillary electrophoresis combined with mass spectrometry (CE‐MS) has been used for several years for the investigation of proteins and peptides as biomarkers for diagnosis and prognosis of diseases. In addition, the technology has recently been introduced to support the stratification of patients in clinical trials and in large clinical studies. In this review, we aim at presenting the development of CE‐MS over the last 20 years, by focusing on the clinical potential of proteome and peptidome analysis and highlighting some of the key technical issues and advancements that have been made in this context towards implementation. Based on the reviewed literature, it has become evident that CE‐MS is now an accepted tool in clinical application in several disease areas. Apart from a critical overview on the current state‐of‐the‐art in CE‐MS, we also indicate the expected developments for potential future use.  相似文献   

10.
Capillary electrophoresis (CE) has attracted lots of attention due to its simplicity, low sample consumption, low solvent volume, high resolution, and high speed. Based on these advantages, it has been widely used in enzyme inhibitor screening. There are two main operation modes on enzyme inhibitor screening: off‐line (precapillary enzyme assays) in which process CE was used as an analytical tool; online (in‐capillary enzyme assays) which combined the sample injection, mix, reaction, separation, and detection within a single run. Additionally, diverse of new materials were introduced to immobilize enzyme, which has been coupled with CE for the study of enzyme activity and its inhibitor screening. This review gives an overview of the developments and applications for the CE‐based enzyme inhibitor screening.  相似文献   

11.
A series of well‐defined triblock copolymers, poly(N, N‐dimethylacrylamide)‐block‐poly(ethylene oxide)‐block‐poly(N, N‐dimethylacrylamide) (PDMA‐b‐PEO‐b‐PDMA) synthesized by atom transfer radical polymerization, were used as physical coatings for protein separation. A comparative study of EOF showed that the triblock copolymer presented good capillary coating ability and EOF efficient suppression. The effects of the Mr of PDMA block in PDMA‐b‐PEO‐b‐PDMA triblock copolymer and buffer pH on the separation of basic protein for CE were investigated. Moreover, the influence of the copolymer structure on separation of basic protein was studied by comparing the performance of PDMA‐b‐PEO‐b‐PDMA triblock copolymer with PEO‐b‐PDMA diblock copolymer. Furthermore, the triblock copolymer coating showed higher separation efficiency and better migration time repeatability than fused‐silica capillary when used in protein mixture separation and milk powder samples separation, respectively. The results demonstrated that the triblock copolymer coatings would have a wide application in the field of protein separation.  相似文献   

12.
Summary Although capillary electrophoresis (CE) methods have been included in some regulatory submissions, the formal requirements for validation of such methods are not well-defined or universally understood. This paper provides a general overview of the aspects of method performance which need to be considered during the validation of CE methods particularly emphasising areas of similarity with, and differences between, HPLC and CE. The individual aspects of method performance are reviewed and guidance given, with illustrative literature examples where possible, on how to carry out suitable validation studies. Performance criteria are also provided, wherever possible. In this way, a suggested validation approach for CE methods is presented, reflecting the similarity with that generally adopted for HPLC methods, but accommodating those aspects which are different for, or peculiar to, CE.  相似文献   

13.
In this work, ion mobility spectrometry (IMS) function as a detector and another dimension of separation was coupled with CE to achieve two‐dimensional separation. To improve the performance of hyphenated CE‐IMS instrument, electrospray ionization correlation ion mobility spectrometry is evaluated and compared with traditional signal averaging data acquisition method using tetraalkylammonium bromide compounds. The effect of various parameters on the separation including sample introduction, sheath fluid of CE and drift gas, data acquisition method of IMS were investigated. The experimental result shows that the optimal conditions are as follows: hydrodynamic sample injection method, the electrophoresis voltage is 10 kilo volts, 5 mmol/L ammonium acetate buffer solution containing 80% acetonitrile as both the background electrolyte and the electrospray ionization sheath fluid, the ESI liquid flow rate is 4.5 μL/min, the drift voltage is 10.5 kilo volts, the drift gas temperature is 383 K and the drift gas flow rate is 300 mL/min. Under the above conditions, the mixture standards of seven tetraalkylammoniums can be completely separated within 10 min both by CE and IMS. The linear range was 5–250 μg/mL, with LOD of 0.152, 0.204, 0.277, 0.382, 0.466, 0.623 and 0.892 μg/mL, respectively. Compared with traditional capillary electrophoresis detection methods, the developed CE‐ESI‐IMS method not only provide two sets of qualitative parameters including electrophoresis migration time and ion drift time, ion mobility spectrometer can also provide an additional dimension of separation and could apply to the detection ultra‐violet transparent compounds or none fluorescent compounds.  相似文献   

14.
The performance of two capillary electrophoresis (CE) instruments, one commercial and one homemade device, were compared for the determination of derivatised aminated compounds with fluorescein isothiocyanate (FITC). The commercial CE system first uses an argon ion laser as excitation source; the homemade CE device uses an inexpensive blue-light-emitting diode (LED) as the light source and a charge-coupled device (CCD) as the detection system. After fine optimisation of several separation parameters in both devices, a co-electroosmotic flow CE methodology was achieved in coated capillary tubing with 0.001% hexadimetrine bromide (HDB), and 50 mmol L−1 sodium borate at pH 9.3 with 20% 2-propanol for the determination of several amines and aminoacids. Analytical performances, applicability in beer samples and other aspects such as cost or potential for miniaturization have been compared for both devices.  相似文献   

15.
Several commercial immobilized metal affinity chromatography sorbents were evaluated in this study for the analysis of two small peptide fragments of the amyloid β‐protein (Aβ) (Aβ(1–15) and Aβ(10–20) peptides) by on‐line immobilized metal affinity SPE‐CE (IMA‐SPE‐CE). The performance of a nickel metal ion (Ni(II)) sorbent based on nitrilotriacetic acid as a chelating agent was significantly better than two copper metal ion (Cu(II)) sorbents based on iminodiacetic acid. A BGE of 25 mM phosphate (pH 7.4) and an eluent of 50 mM imidazole (in BGE) yielded a 25‐fold and 5‐fold decrease in the LODs by IMA‐SPE‐CE‐UV for Aβ(1–15) and Aβ(10–20) peptides (0.1 and 0.5 μg/mL, respectively) with regard to CE‐UV (2.5 μg/mL for both peptides). The phosphate BGE was also used in IMA‐SPE‐CE‐MS, but the eluent needed to be substituted by a 0.5% HAc v/v solution. Under optimum preconcentration and detection conditions, reproducibility of peak areas and migration times was acceptable (23.2 and 12.0%RSD, respectively). The method was more sensitive for Aβ(10–20) peptide, which could be detected until 0.25 μg/mL. Linearity for Aβ(10–20) peptide was good in a narrow concentration range (0.25–2.5 μg/mL, R2 = 0.93). Lastly, the potential of the optimized Ni(II)‐IMA‐SPE‐CE‐MS method for the analysis of amyloid peptides in biological fluids was evaluated by analyzing spiked plasma and serum samples.  相似文献   

16.
17.
Summary Intensive work has been invested in recent years to evaluate the performance of capillary electrophoresis (CE) in forensic analysis. Tremendous progress has also been achieved in interfacing CE to sensitive and specific detection systems such as the mass spectrometer (MS). We have recently developed an electrospray time-of-flight mass spectrometer (ESI-TOFMS) for use as a detector for fast and efficient liquid phase separations. In the present paper we investigated ESI-TOFMS for the analysis of an opium powder. Both continuous infusion and CE were studied for direct sample introduction into the TOFMS and mixture separation, respectively. CEMS analysis of the opium was performed in a citrate buffer, using aqueous or mixed aqueous/organic eluents. Low fmol detection was achieved.  相似文献   

18.
Xiong B  Wang W  Miao X  Zhou X  Deng Y  Zhou P  Hu J 《Electrophoresis》2008,29(22):4482-4486
This Short Communication describes a novel optical detection method for CE, based on the combination of LIF detection and retro-reflected beam interference detection. By the use of a side-illuminated laser beam, an on-column multifunctional detection for CE has been developed, and some key elements in the scheme have been optimized. In addition, two miscellaneous samples including fluorescent dyes, carbohydrates and amino acids have been determined to evaluate its performance. Without any additional pretreatment, sufficient LOD and linear ranges have been achieved for most analytes. Its performance in retro-reflected beam interference detection is better than those mentioned in a former report, and its fluorescent sensitivity is comparable with the achievable sensitivity by conventional LIF systems, all of which together combine high sensitivity and universal analysis to a certain extent.  相似文献   

19.
Capillary electrophoresis (CE) offers fast and high‐resolution separation of charged analytes from small injection volumes. Coupled to mass spectrometry (MS), it represents a powerful analytical technique providing (exact) mass information and enables molecular characterization based on fragmentation. Although hyphenation of CE and MS is not straightforward, much emphasis has been placed on enabling efficient ionization and user‐friendly coupling. Though several interfaces are now commercially available, research on more efficient and robust interfacing with nano‐electrospray ionization (ESI), matrix‐assisted laser desorption/ionization (MALDI) and inductively coupled plasma mass spectrometry (ICP) continues with considerable results. At the same time, CE‐MS has been used in many fields, predominantly for the analysis of proteins, peptides and metabolites. This review belongs to a series of regularly published articles, summarizing 248 articles covering the time between June 2016 and May 2018. Latest developments on hyphenation of CE with MS as well as instrumental developments such as two‐dimensional separation systems with MS detection are mentioned. Furthermore, applications of various CE‐modes including capillary zone electrophoresis (CZE), nonaqueous capillary electrophoresis (NACE), capillary gel electrophoresis (CGE) and capillary isoelectric focusing (CIEF) coupled to MS in biological, pharmaceutical and environmental research are summarized.  相似文献   

20.
用于电渗控制的新型毛细管电泳装置   总被引:2,自引:0,他引:2  
朱英  陈义 《分析化学》1998,26(4):373-377
提出了一种可利用径向电场控制电渗的新型毛细管电泳装置,着重讨论了其工作原理,电渗控制方法及相关结果。该装置不仅能方便地实现电渗的电场控制,而且通过略加改进,还能与商品仪器兼容。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号