首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 93 毫秒
1.
《Electrophoresis》2018,39(16):2069-2082
High‐resolution capillary zone electrophoresis – mass spectrometry (CZE‐MS) has been of increasing interest for the analysis of biopharmaceuticals. In this work, a combination of middle‐down and intact CZE‐MS analyses has been implemented for the characterization of a biotherapeutic monoclonal antibody (mAb) with a variety of post‐translational modifications (PTMs) and glycosylation structures. Middle‐down and intact CZE separations were performed in an acidified methanol‐water background electrolyte on a capillary with a positively charged coating (M7C4I) coupled to an Orbitrap mass spectrometer using a commercial sheathless interface (CESI). Middle‐down analysis of the IdeS‐digested mAb provided characterization of PTMs of digestion fragments. High resolution CZE enabled separation of charge variants corresponding to 2X‐deamidated, 1X‐deamidated, and non‐deamidated forms at baseline resolution. In the course of the middle‐down CZE‐MS analysis, separation of glycoforms of the FC/2 fragment was accomplished due to hydrodynamic volume differences. Several identified PTMs were confirmed by CZE‐MS2. Incorporation of TCEP‐HCl reducing agent in the sample solvent resulted in successful analysis of reduced forms without the need for alkylation. CZE‐MS studies on the intact mAb under denaturing conditions enabled baseline separation of the 2X‐glycosylated, 1X‐glycosylated, and aglycosylated populations as a result of hydrodynamic volume differences. The presence of a trace quantity of dissociated light chain was also detected in the intact protein analysis. Characterization of the mAb under native conditions verified identifications achieved via intact analysis and allowed for quantitative confirmation of proteoforms. Analysis of mAbs using CZE‐MS represents a complementary approach to the more conventional liquid‐chromatography – mass spectrometry‐based approaches.  相似文献   

2.
Capillary isoelectric focusing (cIEF) was online coupled to a Q‐TOF MS by a flow‐through microvial interface for the analysis of therapeutic mAb. Intact molecular weights obtained from the mass spectrum deconvolution of separated charge variants provided information on the structural heterogeneity of therapeutic mAbs. A sandwich cIEF–MS configuration composed of anolyte, sample, and catholyte segments sequentially injected into a neutrally coated capillary was used for the charge heterogeneity separation of four mAbs. Acetic acid and ammonium hydroxide were used in places of the non‐volatile acids and bases commonly used for IEF but are incompatible with online MS detection. Glycerol was added as the anti‐convective reagent. A chemical modifier was mixed with the cIEF effluent in the flow‐throw microvial to maintain the ESI stability and to mitigate ion suppression from the co‐eluted carrier ampholytes and glycerol. Analysis of mAb samples have shown relative populations of two basic variants originating from C‐terminal lysine process and acidic variant of deamidation. The lysine clippings, deamidation, and sialic acid modification in oligosaccharide chains were revealed in infliximab. Two lysine clipping variants and a deamidated variant were observed in adalimumab. The duplicate analyses of a reference mAb demonstrated five charge variants separated by cIEF due to some unidentified modifications, as their mass spectra shared close similarities. The mAb analyses demonstrated the feasibility of the cIEF–MS method, and they demonstrated how charge and structural variants and minor differences in therapeutic mAbs are observed with this technology. Online cIEF–MS is an information rich technology with high throughput, demonstrated by the initial data presented here.  相似文献   

3.
Sanzgiri RD  McKinnon TA  Cooper BT 《The Analyst》2006,131(9):1034-1043
Capillary zone electrophoresis (CZE) has been used to resolve the charge heterogeneity of an intact ( approximately 150 kDa) monoclonal IgG antibody (mAb). Although this microheterogeneity can also be observed by isoelectric focusing, CZE allows the net charge of each variant to be measured as a function of pH and other solution conditions. Separation was achieved in both borate and Tris run buffers using capillaries that had been statically coated with hydroxypropylcellulose (HPC). The HPC coating makes inadvertent chromatographic retention of the mAb undetectably small and decreases electroosmotic flow (EOF) to approximately 10(-5) cm(2) V(-1) s(-1), with reasonable stability over dozens of runs under the conditions tested (pH 8.5 and 9.0 for each buffer). We also describe a novel means of measuring small, positive EOF coefficients and larger, negative net mobilities in the same run. This allows determination of accurate electrophoretic mobilities despite variations in EOF. The resolved mAb charge variants (which most likely result from deamidation or partial truncation) constitute what we call an "intrinsic" charge ladder. As with conventional charge ladders formed by deliberate modification of a homogeneous protein, net charge is obtained by extrapolating a plot of electrophoretic mobility versus (assumed) incremental charge difference. At a given pH, the mAb is more negatively charged in borate than in Tris, reflecting specific binding of the B(OH)(4)(-) anion. We also report hydrodynamic radii calculated from the slopes of these plots.  相似文献   

4.
Analytical platforms that characterize charge heterogeneity in therapeutic proteins, such as mAbs, are important tools that can be used to define quality attributes. CZE separates protein moieties close to their native state and is a valuable physicochemical analytical method that can be used in parallel with other orthogonal methods for characterization and comparability. In this study, custom conditions for the analysis of charge heterogeneity of two mAbs were developed with regard to critical parameters in the BGE, running conditions, and sample treatment. The method application was tested for up to four mAbs and one mAb fragment. The electropherograms showed specific profiles and contrasting levels of basic and acidic isoforms with respect to the main isoform. Issues that surround this method, such as peak tailing and capillary lifetime, are summarized. Using this method, the identities of rituximab and trastuzumab were confirmed, based on the correspondence between the biosimilars and reference products, noninterference of the sample matrix, and the ability to separate spiked samples of related mAbs. The RSD of the isoform content and migration time for the method repeatability were less than 2 and 1%, respectively.  相似文献   

5.
A capillary zone electrophoresis (CZE) method was developed for the rapid analysis of charge heterogeneity of immunoglobulin G (IgG) monoclonal antibodies (mAbs). The separation was carried out in a short, dynamically coated fused-silica capillary. A number of separation parameters were investigated and optimized, including pH, concentration of the separation buffer (ε-amino caproic acid), concentration of the triethylenetetramine (TETA) dynamic coating, the capillary internal diameter and the field strength used for the separation. The effects of between-run flushing of the capillary and the data acquisition rate were also evaluated. Under the optimized conditions, a fast (<5 min), selective and reproducible separation of mAb charge variants was achieved under a very high electric field strength (1000 V/cm). This method also requires only a short conditioning of the capillary, with between-run conditioning completed within 2 min. The method was evaluated for specificity, sensitivity, linearity, accuracy and precision. The same separation conditions were applied to the rapid separation (2-5 min) of charge variants of multiple monoclonal antibodies with pI in the range of 7.0-9.5. Compared with other existing methods for charge variants analysis, this method has several advantages including a short run time, rapid capillary conditioning and simple sample preparation.  相似文献   

6.
Charge heterogeneity profiling is important for the quality control (QC) of biopharmaceuticals. Because of the increasing complexity of these therapeutic entities [1], the development of alternative analytical techniques is needed. In this work, flow‐through partial‐filling affinity capillary electrophoresis (FTPFACE) has been established as a method for the analysis of a mixture of two similar monoclonal antibodies (mAbs). The addition of a specific ligand results in the complexation of one mAb in the co‐formulation, thus changing its migration time in the electric field. This allows the characterization of the charged variants of the non‐shifted mAb without interferences. Adsorption of proteins to the inner capillary wall has been circumvented by rinsing with guanidine hydrochloride before each injection. The presented FTPFACE approach requires only very small amounts of ligands and provides complete comparability with a standard CZE of a single mAb.  相似文献   

7.
The rise of biosimilar monoclonal antibodies has renewed the interest in monoclonal antibody (mAb) charge variants composition and separation. The sample displacement chromatography (SDC) has the potential to overcome the low separation efficiency and productivity associated with bind-elute separation of mAb charge variants. SDC in combination with weak cation exchanging macroporous monolithic chromatographic column was successfully implemented for a separation of charge variants and aggregates of monoclonal IgG under overloading conditions. The charge variants composition was at-line monitored by a newly developed, simple and fast analytical method, based on weak cation exchange chromatography. It was proven that basic charge variants acted as displacers of IgG molecules with lower pI, when the loading was performed 1 to 1.5 pH unit below the pI of acidic charge variants. The efficiency of the SDC process is flow rate independent due to a convection-based mass transfer on the macroporous monolith. The productivity of the process at optimal conditions is 35 mg of purified IgG fraction per milliliters of monolithic support with 75–80% recovery. As such, an SDC approach surpasses the standard bind-elute separation in the productivity for a factor of 3, when performed on the same column. The applicability of the SDC approach was confirmed for porous particle-based column as well, but with 1.5 lower productivity compared to the monoliths.  相似文献   

8.
A two-step CIEF with chemical mobilization was developed for charge profiling of the therapeutic mAb rituximab under non-denaturing separation conditions. CIEF of the intact mAb was combined with a middle-down approach analyzing Fc/2 and F(ab´)2 fragments after digest with a commercial cysteine protease (IdeS). CIEF methods were optimized separately for the intact mAb and its fragments due to their divergent pIs. Best resolution was achieved by combining Pharmalyte (PL) 8–10.5 with PL 3–10 for variants of intact rituximab and of F(ab´)2 fragments, respectively, whereas PL 6.7–7.7 in combination with PL 3–10 was used for Fc/2 variants. Charge heterogeneity in Fc/2 dominates over F(ab´)2. In addition, a copy product of rituximab, and adalimumab were analyzed. Both mAbs contain additional alkaline C-terminal lysine variants as confirmed by digest with carboxypeptidase B. The optimized CIEF methods for intact mAb and Fc/2 were tested for their potential as platform approaches for these mAbs. The CIEF method for Fc/2 was slightly adapted in this process. The pI values for major intact mAb variants were determined by adjacent pI markers resulting in 9.29 (rituximab) and 8.42 (adalimumab). In total, seven to eight charge variants could be distinguished for intact adalimumab and rituximab, respectively.  相似文献   

9.
mAbs are highly complex proteins that present a wide range of microheterogeneity that requires multiple analytical methods for full structure assessment and quality control. As a consequence, the characterization of mAbs on different levels is particularly product‐ and time‐consuming. CE‐MS couplings, especially to MALDI, appear really attractive methods for the characterization of biological samples. In this work, we report the last instrumental development and performance of the first totally automated off‐line CE‐UV/MALDI‐MS/MS. This interface is based on the removal of the original UV cell of the CE apparatus, modification of the spotting device geometry, and creation of an integrated delivery matrix system. The performance of the method was evaluated with separation of five intact proteins and a tryptic digest mixture of nine proteins. Intact protein application shows the acquisition of electropherograms with high resolution and high repeatability. In the peptide mapping approach, a total number of 154 unique identified peptides were characterized using MS/MS spectra corresponding to average sequence coverage of 64.1%. Comparison with NanoLC/MALDI‐MS/MS showed complementarity at the peptide level with an increase of 42% when using CE/MALDI‐MS coupling. Finally, this work represents the first analysis of intact mAb charge variants by CZE using an MS detection. Moreover, using a peptide mapping approach CE‐UV/MALDI‐MS/MS fragmentation allowed 100% sequence coverage of the light chain and 92% of the heavy chain, and the separation of four major glycosylated peptides and their structural characterization.  相似文献   

10.
Imaged capillary isoelectric focusing (iCIEF) has emerged as an important technique for therapeutic monoclonal antibody (mAb) charge heterogeneity analysis in the biopharmaceutical context, providing imaged detection and quantitation by UV without a mobilization step. Besides quantitation, the characterization of separated charge variants ideally directly by online electrospray ionization–mass spectrometry (ESI–MS) is crucial to ensure product quality, safety, and efficacy. Straightforward direct iCIEF–MS coupling combining high separation efficiency and quantitative results of iCIEF with the characterization power of MS enables deep characterization of mAb charge variants. A short technical setup and optimized methodical parameters (30 nl/min mobilization rate, 2%–4% ampholyte concentration, 0.5–2 mg/ml sample concentration) allow successful mAb charge variant peak assignment from iCIEF to MS. Despite a loss of separation resolution during the transfer, separated intact mAb charge variants, including deamidation as well as major and minor glycoforms even from low abundant charge variants, could be characterized by online ESI–MS with high precision. The presented setup provides a large potential for mAb charge heterogeneity characterization in biopharmaceutical applications.  相似文献   

11.
《Electrophoresis》2017,38(9-10):1344-1352
mAbs are currently mainstream in biopharmaceuticals, and their market has been growing due to their high target specificity. Characterization of heterogeneities in mAbs is performed to secure their quality and safety by physicochemical analyses. However, they require time‐consuming task, which often strain the resources of drug development in pharmaceuticals. Rapid and direct method to determine the heterogeneities should be a powerful tool for pharmaceutical analysis. Considering the advantages of electrophoresis and MS, this study addresses the combination of SDS‐PAGE and intact mass analysis, which provides direct, rapid, and orthogonal determination of heterogeneities in mAb therapeutics. mAb therapeutics that migrated in SDS‐PAGE were recovered from gel by treatment with SDC‐containing buffer. Usage of SDC‐containing buffer as extraction solvent and ethanol‐based staining solution enhanced the recovery of intact IgG from SDS‐PAGE gels. Recovery of mAbs reached more than 86% with 0.2% SD. The heterogeneities, especially N ‐glycan variants in the recovered mAb therapeutics, were clearly determined by intact mass analysis. We believe that the study is important in pharmaceuticals‧ perspective since orthogonal combination of gel electrophoresis and intact mass analysis should be pivotal role for rapid and precise characterization of mAbs.  相似文献   

12.
Monoclonal antibody (mAb) therapeutics attract the largest concern due to their strong therapeutic potency and specificity. The Fc region of mAbs is common to many new biotherapeutics as biosimilar, antibody drug conjugate or fusion protein. Fc region has consequences for Fc-mediated effector functions that might be desirable for therapeutic applications. As a consequence, there is a continuous need for improvement of analytical methods to enable fast and accurate characterization of biotherapeutics. Capillary zone electrophoresis-Mass spectrometry couplings (CZE-MS) appear really attractive methods for the characterization of biological samples. In this report, we used CZE-MS systems developed in house and native MS infusion to allow precise middle-up characterization of Fc/2 variant of cetuximab. Molecular weights were measured for three Fc/2 charge variants detected in the CZE separation of cetuximab subunits. Two Fc/2 C-terminal lysine variants were identified and separated. As the aim is to understand the presence of three peaks in the CZE separation for two Fc/2 subunits, we developed a strategy using CZE-UV/MALDI-MS and CZE-UV/ESI-MS to evaluate the role of N-glycosylation and C-terminal lysine truncation on the CZE separation. The chemical structure of N-glycosylation expressed on the Fc region of cetuximab does not influence CZE separation while C-terminal lysine is significantly influencing separation. In addition, native MS infusion demonstrated the characterization of Fc/2 dimers at pH 5.7 and 6.8 and the first separation of these dimers using CZE-MS.  相似文献   

13.
A robust and highly reproducible capillary isoelectric focusing (cIEF) method for the evaluation of charge heterogeneity of monoclonal antibody (mAb) pharmaceutical which contains covalently bound antitumor compounds was developed using a combination of commercially available dimethylpolysiloxane-coated capillary and carrier ampholyte. In order to optimize major analytical parameters for robust mobilization, experimental responses from three pI markers were selected. The optimized method gave excellent repeatability and intermediate precision in estimated pI values of charge variants with relative standard deviations (RSDs) of not more than 0.06% and 0.95%, respectively, when using IgG(4) as a model. Furthermore, RSDs of charge variant compositions were less than 5.0%. These results suggest that the proposed method can be a powerful tool for reproducible evaluation of charge variants of both naked mAbs and their conjugates with high resolution, and it is applicable to quality testing and detailed characterization in the pharmaceutical industry. In addition, it should be noticed that the method provided non-linear pH gradient within the tested ranges, from pI 9.50 to 3.78, and the pH gradient caused the inconsistency of estimated pI ranges between cIEF and gel IEF. This result indicates that selecting appropriate pI markers based on the target pI ranges of charge variants for each mAb related pharmaceutical is highly recommended for the precise determination of pI values.  相似文献   

14.
Monoclonal antibodies (mAbs) have become an important class of biopharmaceuticals used for the treatment of various diseases. Their quantification during the manufacturing process is important. In this work, a capillary zone electrophoresis (CZE) method was developed for the monitoring of the mAb concentration during cell-culture processes. CZE method development rules are outlined, particularly discussing various capillary coatings, such as a neutral covalent polyvinyl alcohol coating, a dynamic successive multiple ionic-polymer coating, and dynamic coatings using background electrolyte additives such as triethanolamine (T-EthA) and triethylamine. The dynamic T-EthA coating resulted in most stable electro-osmotic flows and most efficient peak shapes. The method is validated over the range 0.1–10 mg/ml, with a linear range of 0.08–1.3 mg/ml and an extended range of 1–10 mg/ml by diluting samples in the latter concentration range 10-fold in water. The intraday precision and accuracy were 2%–12% and 88%–107%, respectively, and inter-day precision and accuracy were 4%–9% and 93%–104%, respectively. The precision and accuracy of the lowest concentration level (0.08 mg/ml) were slightly worse and still well in scope for monitoring purposes. The presented method proved applicable for analysing in-process cell-culture samples from different cell-culture processes and is possibly well suited as platform method.  相似文献   

15.
《Electrophoresis》2017,38(6):914-921
CIEF represents an elegant technique especially for the separation of structural similar analytes, whereas MS is a state‐of‐the‐art instrumentation for the identification and characterization of biomolecules. The combination of both techniques can be realized by hyphenating CIEF with CZE‐ESI‐MS applying a mechanical valve. During the CZE step, the remaining ESI‐interfering components of the CIEF electrolyte are separated from the analytes prior to MS detection. In this work, a multiple heart‐cut approach is presented expanding our previous single heart‐cut concept resulting in a dramatical reduction of analysis time. Moreover, different sample transfer loop volumes are systematically compared and discussed in regard to peak width and transfer efficiency. With this major enhancement, model proteins (1.63–9.75 mg/L), covering a wide pI range (5–10), and charge variants from a deglycosylated model antibody were analyzed on intact level. The promising CIEF‐CZE‐MS setup is expected to be applicable in different bioanalytical fields, e.g. for the fast and information rich characterization of therapeutic antibodies.  相似文献   

16.
Immunization with complex mixtures, like the human plasma resulted in the generation of cloned mAb libraries (PlasmaScan? and QuantiPlasma? libraries, with >1000 individual mAbs) reacting with a nonredundant set of antigenic epitopes. mAb proteomics refers to quasi‐hypothesis‐free profiling of plasma samples with nascent or cloned mAb libraries for the discovery of disease‐specific biomarkers. Once mAbs with biomarker potential have been identified, the next task is the determination of cognate antigens recognized by the respective mAbs. To determine the cognate protein antigen corresponding to each individual mAbs in the cloned mAb libraries, we have separated human plasma by consecutive steps of desalting and various chromatography procedures. The process resulted in 783 fractions, which we termed “Analyte Library” (AL). The AL represents the human plasma proteome in relatively low‐protein complexity fractions. Here, to determine the utility of the AL, we selected ten plasma proteins and checked for their presence in the fractions. Among the ten cases, the distribution of four selected plasma proteins matched expectations, as these proteins were present only in a few fractions corresponding to their physical, chemical, and biochemical properties. However, in six cases, we observed “smear” ‐like distribution or complete absence of the proteins, suggesting that protein–protein interactions or protein variants may alter the observed plasma distribution profiles. Nevertheless, we conclude that the AL is an efficient, high throughput tool to complement the mAb biomarker discovery process with cognate protein antigen identification for each mAbs.  相似文献   

17.
Capillary isoelectric focusing (CIEF) is a common choice for separation and analysis of the charge variants and impurities of therapeutic proteins. In this study, we developed a sensitive CIEF analysis method for determining the charge heterogeneity of therapeutic monoclonal antibody (mAb) using Beckman PA800 plus platform. The mixture of 5% Pharmalyte 8-10.5 and 1% Pharmalyte 3-10 was used to overcome the limitation of using single Pharmalyte 3-10 in detecting charge heterogeneity of basic mAb. This approach largely improved the resolution of the heterogeneous peaks. In addition, 3 M urea and 50 mM arginine (Arg) were used to improve the separation as solubilizer and cathodic stabilizer, respectively. Under optimized condition, both acidic and basic peaks of the mAb were separated well. Method qualification results showed good specificity, precision, and linearity within the concentration range of 0.03-0.20 mg/mL for mAb R1. The method was then used for C-terminal lysine (Lys) variants characterization and glycosylation profiles analysis. Furthermore, it also had a wide application in the clone screening process. The highly sensitive and repeatable results highlighted the wide application prospects of this method in biopharmaceutical industry.  相似文献   

18.
Two in‐line enrichment procedures (large volume sample stacking (LVSS) and field amplified sample injection (FASI)) have been evaluated for the CZE analysis of haloacetic acids (HAAs) in drinking water. For LVSS, separation on normal polarity using 20 mM acetic acid–ammonium acetate (pH 5.5) containing 20% ACN as BGE was required. For FASI, the optimum conditions were 25 s hydrodynamic injection (3.5 kPa) of a water plug followed by 25 s electrokinetic injection (?10 kV) of the sample, and 200 mM formic acid–ammonium formate buffer at pH 3.0 as BGE. For both FASI and LVSS methods, linear calibration curves (r2>0.992), limit of detection on standards prepared in Milli‐Q water (49.1–200 μg/L for LVSS and 4.2–48 μg/L for FASI), and both run‐to‐run and day‐to‐day precisions (RSD values up to 15.8% for concentration) were established. Due to the higher sensitive enhancement (up to 310‐fold) achieved with FASI‐CZE, this method was selected for the analysis of HAAs in drinking water. However, for an optimal FASI application sample salinity was removed by SPE using Oasis WAX cartridges. With SPE‐FASI‐CZE, method detection limits in the range 0.05–0.8 μg/L were obtained, with recoveries, in general, higher than 90% (around 65% for monochloroacetic and monobromoacetic acids). The applicability of the SPE‐FASI‐CZE method was evaluated by analyzing drinking tap water from Barcelona where seven HAAs were found at concentration levels between 3 and 13 μg/L.  相似文献   

19.
Capillary zone electrophoresis (CZE) has been applied to qualitative analysis, separation, and physicochemical characterization of synthetic insect oostatic peptides (IOPs) and their derivatives and fragments. Series of homologous IOPs were separated in three acidic background electrolytes (BGEs; pH 2.25, 2.30, 2.40) and an alkaline BGE (pH 8.1). Best separation was achieved in acid BGE composed of 100 mM H3PO4, 50 mM Tris, pH 2.25. The effective electrophoretic mobilities, mu(ep), of all IOPs in four BGEs were determined and several semiempirical models correlating effective mobility with charge-to-size ratio (mu(ep) versus q/Mr k) were tested to describe the migration behavior of IOP in CZE. None of models was found to be unambiguously applicable for the whole set of 20 IOPs differing in size (dipeptide - decapeptide) and charge (-2 to +0.77 elementary charges). However, a high coefficient of correlation, 0.9993, was found for the subset of homologous series of IOPs with decreasing number of proline residues at C-terminus, H-Tyr-Asp-Pro-Ala-Prox-OH, x = 6 - 0, for the dependence of mu(ep) on q/Mr k with k = 0.5 for IOPs as anions in alkaline BGE and with k = 2/3 for IOPs as cations in optimized acidic Tris-phosphate BGE. From these dependences the probable structure of IOPs in solution could be predicted.  相似文献   

20.
This paper describes the analysis of recombinant human deoxyribonuclease (rhDNAse), an acidic and complex phosphoglycoprotein, by capillary zone electrophoresis (CZE). Separation performance was found to be dramatically improved by the addition of calcium ions to the CZE running buffer, due to the influence of calcium binding on the charge and the electrophoretic behavior of rhDNAse. The pH dependent calcium binding effects on the electrophoretic separation were demonstrated at both acidic and basic pH, resulting in a two-dimensional (pH 4.8 and 8.0) calcium aided analysis that achieved multipeak resolution of the complex, glycosylation based, charge microheterogeneity of rhDNAse. Two-dimensional investigation of neuraminidase- and alkaline phosphatase-digested protein further demonstrated that the acidic pH resolved acidic charge heterogeneity and that the basic pH discriminated neutral heterogeneity. This work demonstrates the resolving power of CZE for the analysis of a complex microheterogeneous glycoprotein, and emphasizes the importance of employing multiple separation conditions in accordance with known structural characteristics of the protein.  相似文献   