1.
An analytical method based on dispersive solid‐phase extraction with a multiwalled carbon nanotubes sorbent coupled with positive pulse glow discharge ion mobility spectrometry was developed for analysis of 30 pesticide residues in drinking water samples. Reduced ion mobilities and the mass–mobility correlation of 30 pesticides were measured. The pesticides were divided into five groups to verify the separation capability of pulse glow discharge in mobility spectrometry. The extraction conditions such as desorption solvent, ionic strength, conditions of adsorption and desorption, the amounts of multiwalled carbon nanotubes, and solution pH were optimized. The enrichment factors of pesticides were 5.4‐ to 48.7‐fold (theoretical enrichment factor was 50‐fold). The detection limits of pesticides were 0.01~0.77 μg/kg. The linear range was 0.005–0.2 mg/L for pesticide standard solutions, with determination coefficients from 0.9616 to 0.9999. The method was applied for the analysis of practical and spiked drinking water samples. All results were confirmed by high‐performance liquid chromatography with tandem mass spectrometry. The proposed method was proven to be a commendably rapid screening qualitative and semiquantitative technique for the analysis of pesticide residues in drinking water samples on site.  相似文献   

2.
A method combining gas chromatography with quadrupole time‐of‐flight mass spectrometry has been developed for the simultaneous analysis of multiple pesticide residues in tobacco leaf. The retention index and high accurate masses of ions from the first‐stage and the second‐stage mass spectra of each pesticide were collected for qualitation and quantification. A total of 115 pesticides were evaluated. The extract from organic tobacco leaf was used as a model matrix. The limit of detection was <10 ng/mL, and the limit of quantification was in the range of 1–20 ng/mL for 95% of the tested pesticides. The correlation coefficients were >0.9900 for all tested pesticides. At three concentrations (10, 50, and 100 ng/mL), most compounds presented satisfactory recoveries ranging from 70 to 120% and good precision <20%. Finally, three tobacco leaf samples collected from a local market were analyzed. A total of three pesticides were found, including dimethachlon, triadimenol, and flumetralin. Each pesticide was confirmed by the presence of three ions at the expected retention index and mass. In conclusion, gas chromatography with quadrupole time‐of‐flight mass spectrometry appears to be one of the most efficient tools for the analysis of pesticide residues in tobacco leaf.  相似文献   

3.
The use of hybrid quadrupole ion mobility spectrometry time‐of‐flight mass spectrometry (Q/IMS/TOFMS) in the metabolite profiling of leflunomide (LEF) and acetaminophen (APAP) is presented. The IMS drift times (Td) of the drugs and their metabolites were determined in the IMS/TOFMS experiments and correlated with their exact monoisotopic masses and other in silico generated structural properties, such as connolly molecular area (CMA), connolly solvent‐excluded volume (CSEV), principal moments of inertia along the X, Y and Z Cartesian coordinates (MI‐X, MI‐Y and MI‐Z), inverse mobility and collision cross‐section (CCS). The correlation of Td with these parameters is presented and discussed. IMS/TOF tandem mass spectrometry experiments (MS2 and MS3) were successfully performed on the N‐acetyl‐p‐benzoquinoneimine glutathione (NAPQI‐GSH) adduct derived from the in vitro microsomal metabolism of APAP. As comparison, similar experiments were also performed using hybrid triple quadrupole linear ion trap mass spectrometry (QTRAPMS) and quadrupole time‐of‐flight mass spectrometry (QTOFMS). The abilities to resolve the product ions of the metabolite within the drift tube and fragment the ion mobility resolved product ions in the transfer travelling wave‐enabled stacked ring ion guide (TWIG) demonstrated the potential applicability of the Q/IMS/TOFMS technique in pharmaceutical metabolite profiling. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

4.
In this work, gas chromatography tandem with electron ionization and full‐scan high‐resolution mass spectrometry with a time‐of‐flight mass analyzer was evaluated for analyzing pesticide residues in teas. The relevant aspects for mass spectrometry analysis, including the resolution and mass accuracy, acquisition rate, temperature of ion source, were investigated. Under acquisition condition in 2‐GHz extended dynamic range mode, accurate mass spectral library including 184 gas chromatography detectable pesticides was established and retrieval parameters were optimized. The mass spectra were consistent over a wide concentration range (three orders) with good match values to those of NIST (EI‐quadrupole). The methodology was verified by the validation of 184 pesticides in four tea matrices. A wide linear range (1–1000 μg/kg) was obtained for most compounds in four matrices. Limit of detection, limit of quantification, and limit of identification values acquired in this study could satisfy the requirements for maximum residue levels prescribed by the European Community. Recovery studies were performed at three concentrations (10, 50, and 100 μg/kg). Most of the analytes were recovered at an acceptable range of 70–120% with relative standard deviations ≤ 20% in four matrices. The potential extension of qualitative screening scope makes gas chromatography tandem with electron ionization and mass spectrometry with a time‐of‐flight mass analyzer a more powerful tool compared with gas chromatography with tandem mass spectrometry.  相似文献   

5.
6.
Detecting pesticide residues in human serum is a challenging process. In this study we developed and validated a method for the extraction and recovery of residues of multiple classes of pesticides from serum using one reagent. Salt‐assisted acetonitrile extraction and high‐performance liquid chromatography with quadrupole time of flight tandem mass spectrometry were used to quantitate 34 pesticides classified in nine groups of chemicals in human serum samples, which are frequently detected in food. The recoveries for 33 of analyzed pesticides ranged from 86 to 112% with relative standard deviations below 15%. The limits of quantitation and linearity of 31 of the pesticides were 1 µg/L and >0.990, respectively. The lower limit of quantitation has been reported in the literature particularly for multi‐classes pesticide mixtures in human serum. The salt–acetonitrile reagent was allowed to achieve good recoveries and detection limits, which could be attributed to salt altering the solvent polarity, preferentially collecting the organic phase in the solution, and promoting the extraction. The developed method was applied for two organophosphate pesticide metabolites, diethylphosphate and 3,5,6‐trichloro‐2‐pyridinol, in serum from rats that were fed a nonlethal quantity of chlorpyrifos. The concentrations of these two were 252.18 ± 15.47 and 0.63 ± 0.23 µg/L, respectively.  相似文献   

7.
The inter‐instrument and inter‐laboratory transferability of a tandem mass spectral reference library originally built on a quadrupole‐quadrupole‐time‐of‐flight instrument was examined. The library consisted of 3759 MS/MS spectra collected from 402 reference compounds applying several different collision‐energy values for fragmentation. In the course of the multicenter study, 22 test compounds were sent to three different laboratories, where 418 tandem mass spectra were acquired using four different instruments from two manufacturers. The study covered the following types of tandem mass spectrometers: quadrupole‐quadrupole‐time‐of‐flight, quadrupole‐quadrupole‐linear ion trap, quadrupole‐quadrupole‐quadrupole, and linear ion trap‐Fourier transform ion cyclotron resonance mass spectrometer. In each participating laboratory, optimized instrumental parameters were gathered solely from routinely applied workflows. No standardization procedure was applied to increase the inter‐instrument comparability of MS/MS spectra. The acquired tandem mass spectra were matched against the established reference library using a sophisticated matching algorithm, which is presented in detail in a companion paper. Correct answers, meaning that the correct compound was retrieved as top hit, were obtained in 98.1% of cases. For the remaining 1.9% of spectra, the correct compound was matched at second rank. The observed high percentage of correct assignments clearly suggests that the developed mass spectral library search approach is to a large extent platform independent. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

8.
The analytical capabilities of liquid chromatography with single-stage high-resolution mass spectrometry have been investigated with emphasis on qualitative aspects related to selective detection during screening and to identification. The study involved 21 different vegetable and fruit commodities, a screening database of 556 pesticides for evaluation of false positives, and a test set of 130 pesticides spiked to the commodities at 0.01, 0.05, and 0.20 mg/kg for evaluation of false negatives. The final method involved a QuEChERS-based sample preparation (without dSPE clean up) and full scan acquisition using alternating scan events without/with fragmentation, at a resolving power of 50,000. Analyte detection was based on extraction of the exact mass (±5 ppm) of the major adduct ion at the database retention time ±30 s and the presence of a second diagnostic ion. Various options for the additional ion were investigated and compared (other adduct ions, M + 1 or M + 2 isotopes, fragments). The two-ion approach for selective detection of the pesticides in the full scan data was compared with two alternative approaches based on response thresholds. Using the two-ion approach, the number of false positives out of 11,676 pesticide/commodity combinations targeted was 36 (0.3 %). The percentage of false negatives, assessed for 2,730 pesticide/commodity combinations, was 13 %, 3 %, and 1 % at the 0.01-, 0.05-, and 0.20-mg/kg level, respectively (slightly higher with fully automated detection). Following the SANCO/12495/2011 protocol for validation of screening methods, the screening detection limit was determined for 130 pesticides and found to be 0.01, 0.05, and ≥0.20 mg/kg for 86, 30, and 14 pesticides, respectively. For the detected pesticides in the spiked samples, the ability for unambiguous identification according to EU criteria was evaluated. A proposal for adaption of the criteria was made.  相似文献   

9.
An automated surface‐sampling technique called liquid extraction surface analysis (LESA), coupled with infusion nano‐electrospray high‐resolution mass spectrometry and tandem mass spectrometry (MS/MS), is described and applied to the qualitative determination of surface chemical residues resulting from the artificial spraying of selected fresh fruits and vegetables with representative pesticides. Each of the targeted pesticides was readily detected with both high‐resolution and full‐scan collision‐induced dissociation (CID) mass spectra. In the case of simazine and sevin, a mass resolution of 100 000 was insufficient to distinguish the isobaric protonated molecules for these compounds. When the surface of a spinach leaf was analyzed by LESA, trace levels of diazinon were readily detected on the spinach purchased directly from a supermarket before they were sprayed with the five‐pesticide mixture. A 30 s rinse under hot running tap water appeared to quantitatively remove all remaining residues of this pesticide. Diazinon was readily detected by LESA analysis on the skin of the artificially sprayed spinach. Finally, incurred pyrimethanil at a level of 169 ppb in a batch slurry of homogenized apples was analyzed by LESA and this pesticide was readily detected by both high‐resolution mass spectrometry and full‐scan CID mass spectrometry, thus showing that pesticides may also be detected in whole fruit homogenized samples. This report shows that representative pesticides on fruit and vegetable surfaces present at levels 20‐fold below generally allowed EPA tolerance levels are readily detected and confirmed by the title technologies making LESA‐MS as interesting screening method for food safety purposes. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

10.
A ‘suspect screening analysis’ method for grape metabolomics by ultra‐high performance‐liquid chromatography (UHPLC) and high‐resolution quadrupole‐time of flight (QTOF) mass spectrometry was recently developed. This method was applied to study grape monoterpene glycosides, the main grape aroma precursors. Since standard compounds were not available, they were tentatively identified by overlapping various analytical approaches, in agreement with the indications recommended in mass spectrometry (MS)‐based metabolomics. Accurate mass and isotopic pattern, MS/MS fragmentation, correlation between fragments observed and putative structures and between liquid chromatography coupled with mass spectrometry (LC/MS) and gas chromatography/mass spectrometry signals were studied. Seventeen monoterpene glycosides were identified without performing the hydrolytic artifacts commonly used to study these compounds which may affect sample profile. This is the first time that a detailed study of these aroma precursors has been carried out by direct LC/MS analysis. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

11.
The potential of three mass spectrometry (MS) analyzers (triple quadrupole, QqQ; time of flight, TOF; and quadrupole time of flight, QTOF) has been investigated and compared for quantification, confirmation and screening purposes in pesticide residue analysis of fruit and vegetable samples. For this purpose, analytical methodology for multiresidue determination of 11 pesticides, taken as a model, has been developed and validated in nine food matrices for the three mass analyzers coupled to ultra high pressure liquid chromatography. In all cases, limits of quantification around 0.01 mg/kg were reached, fulfilling the most restrictive case of baby‐food analysis. Regarding absolute sensitivity, the lower limits of detection were obtained, as expected, for QqQ (100 fg), whereas slightly higher limits (300 fg) were obtained for both TOF and QTOF. Confirmative capacity of each analyzer was studied for each analyte based on the identification points (IPs) criterion, useful for a comprehensive comparison. QTOF mass analyzer showed the highest confirmatory capacity, although QqQ normally led to sufficient number of IPs, even at lower concentration levels. The potential of TOF MS was also investigated for screening purposes. To this aim, around 50 commercial fruits and vegetables samples were analyzed, searching for more than 400 pesticides. TOF MS proved to be an attractive analytical tool for rapid detection and reliable identification of a large number of pesticides thanks to the full spectrum acquisition at accurate mass with satisfactory sensitivity. This process is readily boosted when combined with specialized software packages, together with theoretical exact mass databases. Several pesticides (e.g. carbendazim in citrus and indoxacarb in grape) were detected in the samples. Further unequivocal confirmation of the identity was performed using reference standards and/or QTOF MS/MS experiments. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

12.
对比研究了气相色谱-串联质谱(GC-MS/MS)与气相色谱-四极杆-飞行时间质谱(GC-QTOF/MS)在水果、蔬菜中208种农药多残留检测中基质效应及方法学效能的差异,提出两种仪器在农药残留检测方面的特点和适用范围,为残留检测分析提供参考。在苹果、柑橘、番茄、黄瓜4种基质,3个添加浓度(5.0、10.0和20.0 μg/kg)下,两种仪器中均有93.0%以上的农药回收率在70%~120%范围内且相对标准偏差(RSD)≤20%(n=5)。检测灵敏度方面,绝大部分农药在两种仪器的检出限均低于5.0 μg/kg,满足各国农药残留限量的要求,且GC-MS/MS灵敏度更高,线性范围更宽,定量能力更加准确。筛查确证方面,GC-QTOF/MS在快速、高通量筛查、准确定性及非目标化合物鉴定等方面表现出了优势。  相似文献   

13.
Pesticides, widely applied in agriculture, can produce a variety of transformation products and their continuous use causes deleterious effects to ecosystem. Efficient and sensitive analytical techniques for enrichment and analysis of pesticides samples are highly required. Compared with other extraction methods, solid‐phase micro extraction is a solvent free, cost effective, robust, versatile, and high throughput sample preparation technique, especially for the analysis of pesticides from complicated matrices. Coupling of solid‐phase micro extraction with gas chromatography and mass spectrometry and liquid chromatography–mass spectrometry has been extensively applied in pesticide analysis. On the other hand, in recent years, combination of fast separation using solid‐phase micro extraction and rapid detection using ambient mass spectrometry is providing highly efficient pesticide screening. This article summarizes the applications of solid‐phase micro extraction coupled to mass spectrometry for pesticides analysis.  相似文献   

14.
Analytical methods based on multiplug filtration cleanup coupled with pulse glow discharge‐ion mobility spectrometry and liquid chromatography tandem mass spectrometry were developed for the analysis of tricaine mesylate residue in fish and fish‐raising water samples. A silica fiber holder and an appropriate new interface were designed to make the direct introduction of the fiber into the pulse glow discharge‐ion mobility spectrometry introduction mechanism. The multiplug filtration cleanup method with adsorption mixtures was optimized for the determination of tricaine mesylate in fish samples. Good linear relationships were obtained by the two methods. For fish samples, limits of detection were 6 and 0.6 μg/kg by ion mobility spectrometry and liquid chromatography with tandem mass spectrometry, respectively. The matrix effect of the established liquid chromatography tandem mass spectrometry method was negligible for fish samples but that of the ion mobility spectrometry method was not. The two methods were compared. The ion mobility spectrometry system could be used a rapid screening tool on site with the advantage of rapidity, simplicity, and portability, and the liquid chromatography tandem mass spectrometry system could be used for validation in laboratory conditions with the advantage of lower limit of detection, stability, and precision.  相似文献   

15.
The quantification of three alkaloids is important because quantitative study is a means of assessing the reliability of the experimental method, and three alkaloids of peimine, peiminine, and peimisine are main active ingredients in Chinese Pharmacopoeia 2015. An effective method based on the matrix solid‐phase dispersion microextraction was developed for the extraction of alkaloid compounds in Fritillariae Thunbergii Bulbus. Target analytes were analyzed by capillary electrophoresis coupled with quadrupole time‐of‐flight mass spectrometry. The optimized experimental condition was that 50 mg Fritillariae Thunbergii Bulbus was blended homogeneously with 10 mg citric acid for 5 min. Two hundred microliters of water acidized by 1 mol/L hydrochloric acid (pH = 4.5) was selected to elute tested alkaloids. The results demonstrated that the investigated method had low limits of detection (1.32–1.59 ng/mL), good recoveries (86.63–98.12%), and reproducibility (relative standard deviations of peak areas < 0.87%). The proposed matrix solid‐phase dispersion microextraction coupled with capillary electrophoresis combined with quadrupole time‐of‐flight mass spectrometry was successfully applied for the extraction of alkaloids in plants.  相似文献   

16.
The isomeric structure of high‐mannose N‐glycans can significantly impact biological recognition events. Here, the utility of travelling‐wave ion mobility mass spectrometry for isomer separation of high‐mannose N‐glycans is investigated. Negative ion fragmentation using collision‐induced dissociation gave more informative spectra than positive ion spectra with mass‐different fragment ions characterizing many of the isomers. Isomer separation by ion mobility in both ionization modes was generally limited, with the arrival time distributions (ATD) often showing little sign of isomers. However, isomers could be partially resolved by plotting extracted fragment ATDs of the diagnostic fragment ions from the negative ion spectra, and the fragmentation spectra of the isomers could be extracted by using ions from limited areas of the ATD peak. In some cases, asymmetric ATDs were observed, but no isomers could be detected by fragmentation. In these cases, it was assumed that conformers or anomers were being separated. Collision cross sections of the isomers in positive and negative fragmentation mode were estimated from travelling‐wave ion mobility mass spectrometry data using dextran glycans as calibrant. More complete collision cross section data were achieved in negative ion mode by utilizing the diagnostic fragment ions. Examples of isomer separations are shown for N‐glycans released from the well‐characterized glycoproteins chicken ovalbumin, porcine thyroglobulin and gp120 from the human immunodeficiency virus. In addition to the cross‐sectional data, details of the negative ion collision‐induced dissociation spectra of all resolved isomers are discussed. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

17.
Comprehensive analysis of fatty alcohol ethoxylates has been conducted by coupling ultra high pressure hydrophilic interaction chromatography and ion mobility spectrometry mass spectrometry. A custom‐designed sub‐2 μm column was used for the chromatographic separation of fatty alcohol ethoxylates by hydrophilic interaction chromatography. Ion mobility spectrometry provided a post‐ionization resolution during a very short period of 6.4 ms. Distinguishable families of singly, doubly, and triply charged fatty alcohol ethoxylates were clearly observed. By virtue of the combination of hydrophilic interaction chromatography and ion mobility spectrometry, comprehensive resolution based on both hydrophobicity difference and mobility disparity has been achieved for fatty alcohol ethoxylates. The orthogonality of the developed separation and analysis system was evaluated with the correlation coefficient and peak spreading angle of 0.0224 and 88.72°, respectively. The actual peak capacity obtained was individually 40 and 193 times than those when hydrophilic interaction chromatography and ion mobility spectrometry were used alone. The collision cross‐sections of fatty alcohol ethoxylates were calculated by calibrating the traveling wave ion mobility device with polyalanine.  相似文献   

18.
An ultra high performance liquid chromatography coupled with electrospray ionization quadrupole time‐of‐flight mass spectrometry method in both positive and negative ion modes was established in order to comprehensively investigate the major constituents in Wu Ji Bai Feng Pill. Briefly, a Waters ACQUITY UPLC HSS C18 column was used to separate the aqueous extract of Wu Ji Bai Feng Pill. A total of 0.1% formic acid in acetonitrile and 0.1% aqueous formic acid v/v were used as the mobile phase. All analytes were determined using quadrupole time‐of‐flight mass spectrometry with electrospray ionization source in positive and negative ion modes. At length, a total of 173 components including flavones and their glycosides, monoterpene glycosides, triterpene saponins, phenethylalchohol glycosides, iridoid glycosides, phthalides, tanshinones, phenolic acids, sesquiterpenoids and cyclopeptides were identified or tentatively characterized in Wu Ji Bai Feng Pill in an analysis of 16.0 min based on the accurate mass and tandem mass spectrometry behaviors. The developed method is rapid and highly sensitive to characterize the chemical constituents of Wu Ji Bai Feng Pill, which could not only be used for chemical standardization and quality control of Wu Ji Bai Feng Pill, but also be helpful for further study in vivo metabolism of Wu Ji Bai Feng Pill.  相似文献   

19.
A sensitive, simple and rapid QuEChERS extraction method and liquid chromatography equipped with triple quadrupole mass spectrometry (LC‐MS/MS) were used to determine 42 pesticides in dates. Acidified acetonitrile and citrate buffer salts were used to extract re‐hydrated samples. Acceptable validation performances were achieved, i.e. recovery range of 70−120% and RSD values ≤20% for 42 analytes at three different concentrations:100, 50 and 10 μg/kg. This method was used to analyse 200 date fruit samples (var. Sukkari) collected from different large markets in the Al‐Qassim region in Saudi Arabia. Pesticide residues were detected in 36 (18%) of the date fruits samples, and 15 samples (7.5%) exceeded the maximum residue levels. The ruggedness test results showed that this method is robust and suitable for the determination of pesticide residues in dates. Additionally, the results showed that the monitored dates did not have a health impact on consumers in Saudi Arabia during the study period.  相似文献   

20.
The development and validation of analytical methods is a key to succeed in investigating noncovalent interactions between biomolecules or between small molecules and biomolecules. Electrospray ionization mass spectrometry (ESI‐MS) was applied with a Fourier transform ion cyclotron resonance mass spectrometer (FTICR‐MS) as well as a quadrupole/time‐of‐flight tandem mass spectrometer (QqToF‐MS) for a systematic investigation of noncovalent complexes based on nucleobase pairing in an artificial and noncharged backbone topology. Synthetical β‐peptide helices covalently modified with nucleobases were organized by recognition of a sequence of four nucleobases. Specific duplexes of β‐peptide helices were obtained on the basis of hydrogen bonding base pair complementarity. Oligomer interactions were detected with defined stoichiometry and sensitivity for the respective duplex stability. FTICR‐MS and QqToF‐MS were used equally well to indicate double strand stabilities in agreement with the dissociation data determined by UV spectroscopy. Furthermore, the dissociation energies of gas phase ions of the noncovalent complexes were analyzed with collision induced dissociation (CID)‐MS/MS and infrared multiphoton dissociation (IRMPD)‐MS/MS. The CID conditions turned out to be too harsh for a differentiation of the duplex stabilities, whereas IRMPD might be developed as a technique to detect even small interaction energy differences. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   