首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
An analytical method is presented for the determination of paraben preservatives in semisolid cream samples by matrix solid‐phase dispersion combined with supramolecular solvent‐based microextraction. Due to the oily and sticky nature of the sample matrix, parabens were first extracted from the samples by matrix solid‐phase dispersion using silica as sorbent material with a clean‐up performed with tetrahydrofuran in the elution step. The eluate (500 μL), 1‐decanol (120 μL), and water (4.4 mL) were then mixed in a polyethylene pipette to form supramolecular solvent. Finally, the analytes in the supramolecular solvent were separated and determined by liquid chromatography with ultraviolet detection. Under optimal extraction conditions, the extraction recoveries of the studied compounds were obtained in the range of 63–83%. The limits of detection for the analytes were between 0.03 and 0.04 μg/g. The precision of the method varied between 4.0–6.7 (intraday) and 6.2–7.9% (interday). Finally, the optimized procedure was applied to the determination of the target preservatives in a variety of cream samples (diaper rash, skin allergy, face and hand moisturizing) with satisfactory recoveries (86–102%).  相似文献   

2.
An in‐tube solid‐phase microextraction device was developed by packing poly(ionic liquids)‐coated stainless‐steel wires into a polyether ether ketone tube. An anion‐exchange process was performed to enhance the extraction performance. Surface properties of poly(ionic liquids)‐coated stainless‐steel wires were characterized by scanning electron microscopy and energy dispersive X‐ray spectrometry. The extraction device was connected to high‐performance liquid chromatography equipment to build an online enrichment and analysis system. Ten polycyclic aromatic hydrocarbons were used as model analytes, and important conditions including extraction time and desorption time were optimized. The enrichment factors from 268 to 2497, linear range of 0.03–20 μg/L, detection limits of 0.010–0.020 μg/L, extraction and preparation repeatability with relative standard deviation less than 1.8 and 19%, respectively were given by the established online analysis method. It has been used to detect polycyclic aromatic hydrocarbons in environmental samples, with the relative recovery (5, 10 μg/L) in the range of 85.1–118.9%.  相似文献   

3.
Stainless‐steel wires coated with mesoporous titanium oxide were placed into a polyether ether ketone tube for in‐tube solid‐phase microextraction, and the coating sorbent was characterized by X‐ray diffraction and scanning electron microscopy. It was combined with high‐performance liquid chromatography to build an online system. Using eight polycyclic aromatic hydrocarbons as the analytes, some conditions including sample flow rate, sample volume, organic solvent content, and desorption time were investigated. Under optimum conditions, an online analysis method was established and provided good linearity (0.03–30 μg/L), low detection limits (0.01–0.10 μg/L), and high enrichment factors (77.6–678). The method was applied to determine target analytes in river water and water sample of coal ash, and the recoveries are in the range of 80.6–106.6 and 80.9–103.5%, respectively. Compared with estrogens and plasticizers, extraction coating shows better extraction efficiency for polycyclic aromatic hydrocarbons.  相似文献   

4.
The quantity of soil fumigants has increased globally that has focused attention on their environmental behavior. However, simultaneous analysis of traces of fumigant residues is often unreported because analysis methods are not readily available to measure them at low concentrations. In this study, typical solvent extraction methods were compared with headspace solid‐phase microextraction methods. Both methods can be used for simultaneously measuring the concentrations of five commonly used soil fumigants in soil or water. The solvent extraction method showed acceptable recovery (76–103%) and intraday relative standard deviations (0.8–11%) for the five soil fumigants. The headspace solid‐phase microextraction method also showed acceptable recovery (72–104%) and precision rates (1.3–17%) for the five soil fumigants. The solvent extraction method was more precise and more suitable for analyzing relatively high fumigant residue levels (0.05–5 μg/g) contained in multiple soil samples. The headspace solid‐phase microextraction method, however, had a much lower limits of detection (0.09–2.52 μg/kg or μg/L) than the solvent extraction method (5.8–29.2 μg/kg), making headspace solid‐phase microextraction most suitable for trace analysis of these fumigants. The results confirmed that the headspace solid‐phase microextraction method was more convenient and sensitive for the determination of fumigants to real soil samples.  相似文献   

5.
Ionic liquids have been widely used in different fields by advantage of their specific properties. In this work, 1‐methyl‐3‐(3‐trimethoxysilyl propyl)imidazolium chloride was prepared and chemically bonded onto basalt fibers for in‐tube solid‐phase microextraction. Through combining in‐tube extraction device with high‐performance liquid chromatography equipped with a diode array detector, an online enrichment and analysis method for eight polycyclic aromatic hydrocarbons was established under the optimum conditions. A good enrichment factor (52–814), good linearity (0.10–15 and 0.20–15 μg/L), low limits of detection (0.03–0.05 μg/L), and low limits of quantitation (0.10–0.20 μg/L) were achieved using a sample volume of 50 mL. Analysis method was applied to the real samples including the groundwater and wastewater from a chemical industry park, some target analytes were detected and the relative recoveries were in the range of 80.4–116.8%.  相似文献   

6.
A solid‐phase microextraction fiber was prepared by coating an optical fiber with a temperature‐sensitive polymer to determine phthalate esters. N‐Isopropylacrylamide and N,N′‐methylenebisacrylamide were used as the monomer and the cross linker, respectively. The fabricated fiber was characterized by FTIR spectroscopy, thermogravimetric analysis, and scanning electron microscopy. During extraction, important factors such as extraction time, pH, temperature, and ionic strength were optimized. The fabricated fiber, which is firm, inexpensive, stable, and efficient, is a vital material used in solid‐phase microextraction. Under optimum conditions, the calibration curve was linear and in the range of 1–20 μg/L (r2 = 0.9747). The high extraction efficiency was obtained for phthalates with a detection limit of 0.12 μg/L. The fabricated fiber was successfully applied to the solid‐phase micro extraction of phthalates from water samples after its extraction, followed by gas chromatography with flame ionization detection.  相似文献   

7.
A novel pre‐treatment was proposed for the simultaneous determination of aflatoxins, ochratoxin A and zearalenone in foodstuffs using high‐performance liquid chromatography with fluorescence detection. The analytical procedure was based on a first step using a quick, easy, cheap, effective, rugged, and safe based extraction procedure, followed by salting out and purification with a C18 solid‐phase extraction column as interference removal clean‐up. Subsequently, collected supernatant was subjected to dispersive liquid–liquid microextraction. Response surface methodology based on central composite design was employed to optimize conditions in the microextraction procedure. Under the optimum conditions, satisfactory analytical performance with recoveries ranging from 63.22 to 107.6% were achieved in different types of cereals and beans, as well as desirable precisions (0.81–8.13%). Limits of detections and quantifications for these six mycotoxins ranging from 0.03 to 13 μg/kg and 0.22 to 44 μg/kg, respectively, were obtained. Finally, the established method was successfully validated by four certified reference materials (P  = 0.897 > 0.05) and applied to 79 samples from local markets.  相似文献   

8.
The determination of 15 pyrethroids in soil and water samples was carried out by gas chromatography with mass spectrometry. Compounds were extracted from the soil samples (4 g) using solid–liquid extraction and then salting‐out assisted liquid–liquid extraction. The acetonitrile phase obtained (0.8 mL) was used as a dispersant solvent, to which 75 μL of chloroform was added as an extractant solvent, submitting the mixture to dispersive liquid–liquid microextraction. For the analysis of water samples (40 mL), magnetic solid‐phase extraction was performed using nanocomposites of magnetic nanoparticles and multiwalled carbon nanotubes as sorbent material (10 mg). The mixture was shaken for 45 min at room temperature before separation with a magnet and desorption with 3 mL of acetone using ultrasounds for 5 min. The solvent was evaporated and reconstituted with 100 μL acetonitrile before injection. Matrix‐matched calibration is recommended for quantification of soil samples, while water samples can be quantified by standards calibration. The limits of detection were in the range of 0.03–0.5 ng/g (soil) and 0.09–0.24 ng/mL (water), depending on the analyte. The analyzed environmental samples did not contain the studied pyrethroids, at least above the corresponding limits of detection.  相似文献   

9.
A solid‐phase microextraction probe was prepared on the surface of a stainless‐steel wire through molecular sol–gel imprinting technology using chlorpyrifos as a template molecule, tetraethoxysilane as a sol–gel precursor, and acrylamide and β‐cyclodextrin as functional monomers. The polymer was characterized by infrared spectrometry and scanning electron microscopy. Moreover, the selectivity and the parameters including the type and volume of the extraction solvents, ionic strength, pH, temperature, extraction time, stirring speed, and desorption time affecting extraction performance were evaluated. Under the optimum solid‐phase microextraction and gas chromatography conditions, the linear ranges were 0.25–25.0 μg/L for chlorpyrifos, quinalphos, triazophos, pirimiphos‐methyl, and chlorpyrifos‐methyl with the correlation coefficient above 0.99. The detection limits (S/N = 3) were in the range of 0.02–0.07 μg/L and the RSDs were <7.3%. The developed method was successfully used to determine the multi‐residues of chlorpyrifos, quinalphos, triazophos, pirimiphos‐methyl, and chlorpyrifos‐methyl in green peppers and cinnamon with satisfactory recoveries.  相似文献   

10.
Polypropylene hollow fibers as the adsorbent were directly filled into a polyetheretherketone tube for in‐tube solid‐phase microextraction. The surface properties of hollow fibers were characterized by a scanning electron microscope. Combined with high performance liquid chromatography, the extraction tube showed good extraction performance for five environmental estrogen hormones. To achieve high analytical sensitivity, four important factors containing sampling volume, sampling rate, content of organic solvent in sample, and desorption time were investigated. Under the optimum conditions, an online analysis method was established with wide linear range (0.03–20 µg/L), good correlation coefficients (≥0.9998), low limits of detection (0.01–0.05 µg/L), low limits of quantitation (0.03–0.16 µg/L), and high enrichment factors (1087–2738). Relative standard deviations (n = 3) for intraday (≤3.6%) and interday (≤5.1%) tests proved the stable extraction performance of the material. Durability and chemical stability of the extraction tube were also investigated, relative standard deviations of all analytes were less than 5.8% (n = 3), demonstrating the satisfactory stability. Finally, the method was successfully applied to detect estrogens in real samples.  相似文献   

11.
The development and application of an imazethapyr molecularly imprinted polymer‐based solid‐phase microextraction coating were investigated. A novel molecularly imprinted polymer coating with imazethapyr as template was firstly prepared by a one‐step in situ polymerization method, and demonstrated specific selectivity to imidazolinone herbicides in complicated samples. The structural characteristics and extraction performance of the imazethapyr molecularly imprinted polymer coating were studied. The molecularly imprinted polymer coating was homogeneous, dense, and heat and solvent resistant. Adsorption capacity experiments showed that the molecularly imprinted polymer coating could selectively extract imazethapyr and its structural analogs, and the maximum adsorption capacity was 2.5 times as much as that of the nonimprinted polymer coating. A method for the determination of five imidazolinones by imazethapyr molecularly imprinted polymer solid‐phase microextraction coupled with high‐performance liquid chromatography was developed. The linear range was 0.50–50 μg/L for imazameth, imazamox, imazapyr acid, and imazethapyr, and 1.0–100 μg/L for imazaquin acid, and the detection limits were within the range of 0.070–0.29 μg/L. The method was applied to simultaneous and multiresidual determinations of trace imidazolinones in rice, peanut, and soil samples with satisfactory recoveries of 60.6–99.5, 79.1–123, and 61.3–116%, respectively, and relative standard deviations of 0.40–10%, which indicated that this method was suitable for the trace analysis of imidazolinones in complex food and environmental samples.  相似文献   

12.
A rapid, low‐cost, and simple method is proposed based on a miniaturized solid‐phase extraction named microextraction in packed syringe coupled with gas chromatography and mass spectrometry for the preconcentration and determination of some organophosphorous pesticides including diazinon, ethion, and malathion. For the first time, natural nanoperlite is used as a safe sorbent. Based on this technique, the analytes are adsorbed on the solid phase and then eluted by a desorbing solvent. The influence of some important parameters such as the solution pH, type, and volume of the organic desorption solvent on the microextraction efficiency of the selected pesticide technique is investigated. The proposed method showed a good linearity in the range of 1.0–35.0 μg/L for ethion and 0.4–30.0 μg/L for both diazinon and malathion. The limits of detection in the range of 0.1–0.38 μg/L were obtained using the selected ion‐monitoring mode of the mass spectrometer. The reproducibility of the method was found to be in the range of 2.8–8.9% for the studied pesticides. To evaluate the matrix effect, the developed method is also applied to the preconcentration and determination of the selected pesticides in real water samples.  相似文献   

13.
A novel solid‐phase microextraction Arrow was used to separate volatile organic compounds from soy sauce, and the results were verified by using gas chromatography with mass spectrometry. Solid‐phase microextraction Arrow was optimized in terms of three extraction conditions: type of fiber used (polydimethylsiloxane, polyacrylate, carbon wide range/polydimethylsiloxane, and divinylbenzene/polydimethylsiloxane), extraction temperature (40, 50, and 60°C), and extraction time (10, 30, and 60 min). The optimal solid‐phase microextraction Arrow conditions were as follows: type of fiber = polyacrylate, extraction time = 60 min, and extraction temperature = 50°C. Under the optimized conditions, the solid‐phase microextraction Arrow was compared with conventional solid‐phase microextraction to determine extraction yields. The solid‐phase microextraction Arrow yielded 6–42‐fold higher levels than in solid‐phase microextraction for all 21 volatile organic compounds detected in soy sauce due to the larger sorption phase volume. The findings of this study can provide practical guidelines for solid‐phase microextraction Arrow applications in food matrixes by providing analytical methods for volatile organic compounds.  相似文献   

14.
The detection frequencies of tefuryltrione, a new type of 4‐hydroxyphenyl‐pyruvate dioxygenase inhibitor herbicide, are rarely reported, probably because of the paucity of analytical methods. Herein, an effective and sensitive analytical method has been developed to detect tefuryltrione in vegetables (tomato and cucumber), cereals (rice and corn), soil, and water by ultra high performance liquid chromatography coupled with tandem mass spectrometry. Comparisons of the performances of dispersive solid‐phase extraction and multiplug filtration cleanup methods were carried out for tefuryltrione in complex matrices. Extraction solvents and purification sorbents were further optimized for dispersive solid‐phase extraction. Tefuryltrione was analyzed with electrospray ionization in the positive mode within 2.0 min. Mean recoveries for tefuryltrione were 75.4–108.9% with relative standard deviations less than 11.0% at three fortification levels (10, 100, 500 μg/kg) in the sample matrixes. Limits of quantification ranged from 0.70 to 5.12 μg/kg, and an excellent linearity (R 2 ≥ 0.9902) was obtained for tefuryltrione at concentrations of 5–1000 μg/L. The results showed that the developed dispersive solid‐phase extraction method could serve as an effective, sensitive, and robust method for routine monitoring of tefuryltrione residue in plants and environmental samples.  相似文献   

15.
The application of layered double hydroxide–Al2O3–polymer mixed‐matrix disks for solid‐phase extraction is reported for the first time. Al2O3 is embedded in a polymer matrix followed by an in situ metal‐exchange process to obtain a layered double hydroxide–Al2O3–polymer mixed‐matrix disk with excellent flow‐through properties. The extraction performance of the prepared disks is evaluated as a proof of concept for the automated extraction using sequential injection analysis of organic acids (p‐hydroxybenzoic acid, 3,4‐dihydroxybenzoic acid, gallic acid) following an anion‐exchange mechanism. After the solid‐phase extraction, phenolic acids were quantified by reversed‐phase high‐performance liquid chromatography with diode‐array detection using a core–shell silica–C18 stationary phase and isocratic elution (acetonitrile/0.5% acetic acid in pure water, 5:95, v/v). High sensitivity and reproducibility were obtained with limits of detection in the range of 0.12–0.25 μg/L (sample volume, 4 mL), and relative standard deviations between 2.9 and 3.4% (10 μg/L, = 6). Enrichment factors of 34–39 were obtained. Layered double hydroxide–Al2O3–polymer mixed‐matrix disks had an average lifetime of 50 extractions. Analyte recoveries ranged from 93 to 96% for grape juice and nonalcoholic beer samples.  相似文献   

16.
A new sol–gel hybrid methyltrimethoxysilane‐chloropropyltriethoxysilane was prepared as sorbent for solid‐phase extraction. The extraction efficiency of the prepared sol–gel hybrid methyltrimethoxysilane‐chloropropyltriethoxysilane was assessed by using three selected organophosphorus pesticides, namely, chlorpyrifos, profenofos, and malathion. Gas chromatography–mass spectrometry was used for detection of organophosphorus pesticides. Several vital parameters were optimized to identify the best extraction conditions. Under the optimum extraction conditions, solid‐phase extraction‐methyltrimethoxysilane‐chloropropyltriethoxysilane method showed good linearity range (0.05‐1 μg/mL) with coefficient of determination more than 0.995. The limits of detection obtained were in the range of 0.01–0.07 μg/mL and limits of quantification ranging from 0.03 to 0.21 μg/mL. The limits of detection obtained for the developed method were 2.3–6.5× lower than the limits of detection of commercial octadecyl silica sorbent. Real samples analysis was carried out by applying the developed method on red apple and purple grape samples. The developed method exhibited good recoveries (88.33–120.7%) with low relative standard deviations ranging from 1.6 to 3.3% compared to commercial octadecyl silica sorbent, which showed acceptable recoveries (70.3–100.2%) and relative standard deviations (6.3–8.8%). The solid‐phase extraction‐methyltrimethoxysilane‐chloropropyltriethoxysilane method is presented as an alternative extraction method for determination of organophosphorus pesticides.  相似文献   

17.
A novel magnetic mesoporous silica material was synthesized and used as the sorbent for the magnetic solid‐phase microextraction of diazinon and malathion before their quantification by high‐performance liquid chromatography with UV detection. The sorbent was synthesized by a surfactant‐templated one‐pot sol–gel procedure using SiO2‐coated Fe3O4 as the magnetic support, cetyltrimethylammonium bromide as the template and tetraethyl orthosilicate as the silicon source. The characteristics of the prepared sorbent were investigated using Fourier transform infrared spectroscopy, scanning electron microscopy, and X‐ray diffraction. The sorbent exhibited a high maximum adsorption capacity of 19.2 and 9.4 mg/g for diazinon and malathion, respectively. The parameters affecting the microextraction were optimized by the MultiSimplex method. Under the optimized conditions, the calibration graphs were linear in the concentration ranges of 0.3–50.0 and 0.5–50 μg/L with the limits of detection of 0.09 and 0.14 μg/L for diazinon and malathion, respectively. The relative standard deviations (n = 5) at a concentration level of 10.0 μg/L of analytes were less than 2.5 and 4% for intra and interday, respectively. The developed method was successfully used for the determination of diazinon and malathion in apple, tomato, cucumber, tap water, and well water samples.  相似文献   

18.
In this study, the viability of two membrane‐based microextraction techniques for the determination of endocrine disruptors by high‐performance liquid chromatography with diode array detection was evaluated: hollow fiber microporous membrane liquid–liquid extraction and hollow‐fiber‐supported dispersive liquid–liquid microextraction. The extraction efficiencies obtained for methylparaben, ethylparaben, bisphenol A, benzophenone, and 2‐ethylhexyl‐4‐methoxycinnamate from aqueous matrices obtained using both approaches were compared and showed that hollow fiber microporous membrane liquid–liquid extraction exhibited higher extraction efficiency for most of the compounds studied. Therefore, a detailed optimization of the extraction procedure was carried out with this technique. The optimization of the extraction conditions and liquid desorption were performed by univariate analysis. The optimal conditions for the method were supported liquid membrane with 1‐octanol for 10 s, sample pH 7, addition of 15% w/v of NaCl, extraction time of 30 min, and liquid desorption in 150 μL of acetonitrile/methanol (50:50 v/v) for 5 min. The linear correlation coefficients were higher than 0.9936. The limits of detection were 0.5–4.6 μg/L and the limits of quantification were 2–16 μg/L. The analyte relative recoveries were 67–116%, and the relative standard deviations were less than 15.5%.  相似文献   

19.
A novel and reliable method for determination of five triazole fungicide residues (triadimenol, tebuconazole, diniconazole, flutriafol, and hexaconazol) in traditional Chinese medicine samples was developed using dispersive solid‐phase extraction combined with ultrasound‐assisted dispersive liquid–liquid microextraction before ultra‐high performance liquid chromatography with tandem mass spectrometry. The clean up of the extract was conducted using dispersive solid‐phase extraction by directly adding sorbents into the extraction solution, followed by shaking and centrifugation. After that, a mixture of 400 μL trichloromethane (extraction solvent) and 0.5 mL of the above supernatant was injected rapidly into water for the dispersive liquid–liquid microextraction procedure. The factors affecting the extraction efficiency were optimized. Under the optimum conditions, the calibration curves showed good linearity in the range of 2.0–400 (tebuconazole, diniconazole, and hexaconazole) and 4.0–800 ng/g (triadimenol and flutriafol) with the regression coefficients higher than 0.9958. The limit of detection and limit of quantification for the present method were 0.5–1.1 and 1.8–4.0 ng/g, respectively. The recoveries of the target analytes ranged from 80.2 to 103.2%. The proposed method has been successfully applied to the analysis of five triazole fungicides in traditional Chinese medicine samples, and satisfactory results were obtained.  相似文献   

20.
Two different modes of three‐phase hollow fiber liquid‐phase microextraction were studied for the extraction of two herbicides, bensulfuron‐methyl and linuron. In these two modes, the acceptor phases in the lumen of the hollow fiber were aqueous and organic solvents. The extraction and determination were performed using an automated hollow fiber microextraction instrument followed by high‐performance liquid chromatography. For both three‐phase hollow fiber liquid‐phase microextraction modes, the effect of the main parameters on the extraction efficiency were investigated and optimized by central composite design. Under optimal conditions, both modes showed good linearity and repeatability, but the three‐phase hollow fiber liquid‐phase microextraction based on two immiscible organic solvents has a better extraction efficiency and figures of merit. The calibration curves for three‐phase hollow fiber liquid‐phase microextraction with an organic acceptor phase were linear in the range of 0.3–200 and 0.1–150 μg/L and the limits of detection were 0.1 and 0.06 μg/L for bensulfuron‐methyl and linuron, respectively. For the conventional three‐phase hollow fiber liquid‐phase microextraction, the calibration curves were linear in the range of 3.0–250 and 15–400 μg/L and LODs were 1.0 and 5.0 μg/L for bensulfuron‐methyl and linuron, respectively. The real sample analysis was carried out by three‐phase hollow fiber liquid phase microextraction based on two immiscible organic solvents because of its more favorable characteristics.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号