首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
An liquid chromatography–quadrupole time‐of‐flight (QqTOF) mass spectrometric method was developed for the determination of humanized or human monoclonal antibodies in rat plasma at the early drug discovery stage. Trastuzumab was used as a model monoclonal antibody. The method consisted of immunoprecipitation followed by tryptic digestion for sample preparation and LC‐TOF‐MS/MS analysis of specific signature peptides in the positive ion mode using electrospray ionization for analysis. A stable isotope‐labeled signature peptide was also used as internal standard. A quadratic regression (weighted 1/concentration2), with an equation y = ax2 + bx + c, was used to fit calibration curves over the concentration range of 0.500–100 µg/mL for trastuzumab. Samples from a pharmacokinetic study in rat were analyzed by this qualified LC‐TOF‐MS/MS method and concentrations were compared with those generated by enzyme linked immunosorbent assays method. The LC‐TOF‐MS/MS method was accurate and precise, with quantitative results comparable with those of ELISA. The qualification run met the acceptance criteria of ±25% accuracy and precision values for quality control samples. Within‐run accuracy ranged from 1.53 to 9.20% with precision values ≤10.29%. This LC‐TOF‐MS/MS method approach could be used as a complementary method for humanized or human monoclonal antibodies at the early drug discovery stage. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

2.
A liquid chromatographic–electrospray ionization–time‐of‐flight/mass spectrometric (LC‐ESI‐TOF/MS) method was developed and applied for the determination of WKYMVm peptide in rat plasma to support preclinical pharmacokinetics studies. The method consisted of micro‐elution solid‐phase extraction (SPE) for sample preparation and LC‐ESI‐TOF/MS in the positive ion mode for analysis. Phenanthroline (10 mg/mL) was added to rat blood immediately for plasma preparation followed by addition of trace amount of 2 m hydrogen chloride to plasma before SPE for stability of WKYMVm peptide. Then sample preparation using micro‐elution SPE was performed with verapamil as an internal standard. A quadratic regression (weighted 1/concentration2), with the equation y = ax2 + bx + c was used to fit calibration curves over the concentration range of 3.02–2200 ng/mL for WKYMVm peptide. The quantification run met the acceptance criteria of ±25% accuracy and precision values. For quality control samples at 15, 165 and 1820 ng/mL from the quantification experiment, the within‐run and the between‐run accuracy ranged from 92.5 to 123.4% with precision values ≤15.1% for WKYMVm peptide from the nominal values. This novel LC‐ESI‐TOF/MS method was successfully applied to evaluate the pharmacokinetics of WKYMVm peptide in rat plasma.  相似文献   

3.
A chemically defined anti‐CXCR4–auristatin antibody–drug conjugate (ADC) was synthesized that selectively eliminates tumor cells overexpressing the CXCR4 receptor. The unnatural amino acid p‐acetylphenylalanine (pAcF) was site‐specifically incorporated into an anti‐CXCR4 immunoglobulin G (IgG) and conjugated to an auristatin through a stable, non‐cleavable oxime linkage to afford a chemically homogeneous ADC. The full‐length anti‐CXCR4 ADC was selectively cytotoxic to CXCR4+ cancer cells in vitro (half maximal effective concentration (EC50)≈80–100 pM ). Moreover, the anti‐CXCR4 ADC eliminated pulmonary lesions from human osteosarcoma cells in a lung‐seeding tumor model in mice. No significant overt toxicity was observed but there was a modest decrease in the bone‐marrow‐derived CXCR4+ cell population. Because CXCR4 is highly expressed in a majority of metastatic cancers, a CXCR4–auristatin ADC may be useful for the treatment of a variety of metastatic malignancies.  相似文献   

4.
Metabolism studies play an important role at various stages of drug discovery and development. Liquid chromatography combined with mass spectrometry (LC/MS) has become a most powerful and widely used analytical tool for identifying drug metabolites. The suitability of different types of mass spectrometers for metabolite profiling differs widely, and therefore, the data quality and reliability of the results also depend on which instrumentation is used. As one of the latest LC/MS instrumentation designs, hybrid ion trap/time‐of‐flight MS coupled with LC (LC‐IT‐TOF‐MS) has successfully integrated ease of operation, compatibility with LC flow rates and data‐dependent MSn with high mass accuracy and mass resolving power. The MSn and accurate mass capabilities are routinely utilized to rapidly confirm the identification of expected metabolites or to elucidate the structures of uncommon or unexpected metabolites. These features make the LC‐IT‐TOF‐MS a very powerful analytical tool for metabolite identification. This paper begins with a brief introduction to some basic principles and main properties of a hybrid IT‐TOF instrument. Then, a general workflow for metabolite profiling using LC‐IT‐TOF‐MS, starting from sample collection and preparation to final identification of the metabolite structures, is discussed in detail. The data extraction and mining techniques to find and confirm metabolites are discussed and illustrated with some examples. This paper is directed to readers with no prior experience with LC‐IT‐TOF‐MS and will provide a broad understanding of the development and utility of this instrument for drug metabolism studies. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

5.
The microalga Haematococcus pluvialis produces the pigment astaxanthin mainly in esterified form with a multitude of fatty acids, which results in a complex mixture of carotenol mono‐ and diesters. For rapid fingerprinting of these esters, matrix‐assisted laser desorption ionization time of flight mass spectrometry (MALDI‐TOF/TOF‐MS) might be an alternative to traditional chromatographic separation combined with MS. Investigation of ionization and fragmentation of astaxanthin mono‐ and diester palmitate standards in MALDI‐TOF/TOF‐MS showed that sodium adduct parent masses [M + Na]+ gave much simpler MS2 spectra than radical / protonated [M]+● / [M + H]+ parents. [M + Na]+ fragments yielded diagnostic polyene‐specific eliminations and fatty acid neutral losses, whereas [M]+● / [M + H]+ fragmentation resulted in a multitude of non‐diagnostic daughters. For diesters, a benzonium fragment, formed by polyene elimination, was required for identification of the second fatty acid attached to the astaxanthin backbone. Parents were forced into [M + Na]+ ionization by addition of sodium acetate, and best signal‐to‐noise ratios were obtained in the 0.1 to 1.0 mM range. This method was applied to fingerprinting astaxanthin esters in a crude H. pluvialis extract. Prior to MALDI‐TOF/TOF‐MS, the extract was fractionated by normal phase Flash chromatography to obtain fractions enriched in mono‐ and diesters and to remove pheophytin a, which compromised monoester signals. All 12 types of all‐trans esterified esters found in LC were identified with MALDI‐TOF/TOF‐MS, with the exception of two minor monoesters. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

6.
3‐Bromomethcathinone (3‐BMC) and 3‐Fluoromethcathinone (3‐FMC) are two new designer drugs, which were seized in Israel during 2009 and had also appeared on the illicit drug market in Germany. These two compounds were sold via the Internet as so‐called “bath salts” or “plant feeders.” The aim of the present study was to identify for the first time the 3‐BMC and 3‐FMC Phase I and II metabolites in rat urine and human liver microsomes using GC–MS and LC–high‐resolution MS (HR‐MS) and to test for their detectability by established urine screening approaches using GC–MS or LC–MS. Furthermore, the human cytochrome‐P450 (CYP) isoenzymes responsible for the main metabolic steps were studied to highlight possible risks of consumption due to drug–drug interaction or genetic variations. For the first aim, rat urine samples were extracted after and without enzymatic cleavage of conjugates. The metabolites were separated and identified by GC–MS and by LC–HR‐MS. The main metabolic steps were N‐demethylation, reduction of the keto group to the corresponding alcohol, hydroxylation of the aromatic system and combinations of these steps. The elemental composition of the metabolites identified by GC–MS could be confirmed by LC–HR‐MS. Furthermore, corresponding Phase II metabolites were identified using the LC–HR‐MS approach. For both compounds, detection in rat urine was possible within the authors' systematic toxicological analysis using both GC–MS and LC–MSn after a suspected recreational users dose. Following CYP enzyme kinetic studies, CYP2B6 was the most relevant enzyme for both the N‐demethylation of 3‐BMC and 3‐FMC after in vitro–in vivo extrapolation. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

7.
Atenolol, nadolol, metoprolol, bisoprolol and betaxolol were simultaneously determined in groundwater samples by large‐volume injection coupled‐column reversed‐phase liquid chromatography with fluorescence detection (LVI‐LC‐LC‐FD) and liquid chromatography‐time‐of‐flight mass spectrometry (LC‐TOF‐MS). The LVI‐LC‐LC‐FD method combines analyte isolation, preconcentration and determination into a single step. Significant reductions in costs for sample pre‐treatment (solvent and solid phases for clean up) and method development times are also achieved. Using LC‐TOF‐MS, accurate mass measurements within 3 ppm error were obtained for all of the β‐blockers studied. Empirical formula information can be obtained by this method, allowing the unequivocal identification of the target compounds in the samples. To increase the sensitivity, a solid‐phase extraction step with Oasis MCX cartridge was carried out yielding recoveries of 79–114% (n=5) with RSD 2–7% for the LC‐TOF‐MS method. SPE gives a high purification of β‐blockers compared with the existing methods. A 100% methanol wash was allowed for these compounds with no loss of analytes. Limit of quantification was 1–7 ng/L for LVI‐LC‐LC‐FD and 0.25–5 ng/L for LC‐TOF‐MS. As a result of selective extraction and effective removal of coextractives, no matrix effect was observed in LVI‐LC‐LC‐FD and LC‐TOF‐MS analyses. The methods were applied to detect and quantify β‐blockers in groundwater samples of Almería (Spain).  相似文献   

8.
A liquid chromatography–triple quadrupole mass spectrometric (LC‐MS/MS) method was developed and validated for the determination of 5‐nitro‐5′‐hydroxy‐indirubin‐3′‐oxime (AGM‐130) in human plasma to support a microdose clinical trial. The method consisted of a liquid–liquid extraction for sample preparation and LC‐MS/MS analysis in the positive ion mode using TurboIonSprayTM for analysis. d3‐AGM‐130 was used as the internal standard. A linear regression (weighted 1/concentration) was used to fit calibration curves over the concentration range of 10–2000 pg/mL for AGM‐130. There were no endogenous interference components in the blank human plasma tested. The accuracy at the lower limit of quantitation was 96.6% with a precision (coefficient of variation, CV) of 4.4%. For quality control samples at 30, 160 and 1600 pg/mL, the between run CV was ≤5.0 %. Between‐run accuracy ranged from 98.1 to 101.0%. AGM‐130 was stable in 50% acetonitrile for 168 h at 4°C and 6 h at room temperature. AGM‐130 was also stable in human plasma at room temperature for 6 h and through three freeze–thaw cycles. The variability of selected samples for the incurred sample reanalysis was ≤12.7% when compared with the original sample concentrations. This validated LC‐MS/MS method for determination of AGM‐130 was used to support a phase 0 microdose clinical trial. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

9.
Liquid chromatography‐tandem mass spectrometry (LC‐MS/MS) method has proved to powerful research tool due to its sensitivity, high selectivity, and high throughput efficiency..Sirolimus was extracted from plasma by two‐step extraction procedure using chloroform as extracting solvent. Signal intensity was high using ESI+ source provided for the quantitation of samples. Chromatographic separation was performed on phenomenax C‐18 column (250 × 4.60 mm 5microns).Mobile phase contains acetonitrile, water (80; 20 v/v) + 0.1% acetic acid, flow rate 1 mL/min.The retention time of Sirolimus 8.4 min, the total run time10 min. Linearity correlation coefficients (r2) curve was 0.997183.calibraction range 10–1000 ng/mL. The UV detection of Sirolimus was at 278(277.78) nm. Sirolimus coated drug eluting stents, MRM (Multiple reaction monitoring) transition of Sirolimus m/z 936.83–208.84 was selected to obtain maximum sensitivity. LC/MS/MS results exhibited consistency in drug content on the stent surface. In‐vitro release kinetic indicated the release of Sirolimus in 41 days from the date of implanted. Drug release was found at the first day, burst release was observed at 7th day of implantation. This study involved pharmacological coating of stents, based on the notion that sustained systemic local delivery of anti‐proliferative agents. LC‐MS/MS method has been successfully used in the pharmacokinetic analysis of Sirolimus coated drug eluting stents. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

10.
A strategy for the preparation of homogeneous antibody–drug conjugates (ADCs) containing multiple payloads has been developed. This approach utilizes sequential unmasking of cysteine residues with orthogonal protection to enable site‐specific conjugation of each drug. In addition, because the approach utilizes conjugation to native antibody cysteine residues, it is widely applicable and enables high drug loading for improved ADC potency. To highlight the benefits of ADC dual drug delivery, this strategy was applied to the preparation of ADCs containing two classes of auristatin drug‐linkers that have differing physiochemical properties and exert complementary anti‐cancer activities. Dual‐auristatin ADCs imparted activity in cell line and xenograft models that are refractory to ADCs comprised of the individual auristatin components. This work presents a facile method for construction of potent dual‐drug ADCs and demonstrates how delivery of multiple cytotoxic warheads can lead to improved ADC activities. Lastly, we anticipate that the conditions utilized herein for orthogonal cysteine unmasking are not restricted to ADCs and can be broadly utilized for site‐specific protein modification.  相似文献   

11.
Soyalkaloid A was isolated from Portulaca oleracea L. for the first time in our laboratory and then a rapid and sensitive ultra‐high‐performance liquid chromatography electrospray ionization quadrupole–time of flight mass spectrometry (UHPLC–ESI–Q–TOF/MS) method with hesperidin as internal standard (IS) was developed and validated to investigate the pharmacokinetics of soyalkaloid A in rats after oral and intravenous administrations. The analysis was achieved on an Agilent Zorbax Eclipse Plus C18 Column (2.1 × 50 mm, 1.8 μm) by elution with acetonitrile and water (containing 0.1% formic acid), at a flow rate of 0.3 mL/min. The MS analysis was performed in the positive ion mode with monitored ion m/z 227.0814 [M + H]+ and 611.1971 [M + H]+ for soyalkaloid A and IS, respectively. The linear range was established over the concentration range 7.5–6000 ng/mL (r = 0.9951). The intra‐ and inter‐assay accuracy and precision were between ?4.86‐4.49 and 1.93–9.66, respectively. The lower limits of detection and quantitation observed were 2.1 and 7.4 ng/mL, respectively. The rapid, sensitive and specific UHPLC–ESI–Q–TOF/MS method was successfully applied to a pharmacokinetic study of soyalkaloid A. Moreover, its antioxidant was studied via a 1,1‐diphenyl‐2‐picryl‐hydrazyl radical scavenging assay, the IC50 value being 20.73 ± 0.51 μM.  相似文献   

12.
An HPLC separation method with triethylammonium acetate mobile phase additive developed for the analysis of impurities in polysulphonated azo dyes provides good separation selectivity and compatibility with electrospray ionisation (ESI) mass spectrometry. The negative‐ion ESI mass spectra containing only peaks of deprotonated molecules [M–H] for monosulphonic acids, [M–xH]x, and sodiated adducts [M–(x + y)H + yNa]x for polysulphonic acids allow easy molecular mass determination of unknown impurities. Based on the knowledge of the molecular masses and of the fragment ions in the MS/MS spectra, probable structures of trace impurities in commercial dye samples are proposed. To assist in the interpretation of the mass spectra of complex polysulphonated azodyes, additional information can be obtained after chemical reduction of azodyes to aromatic amines. The structures of the non‐sulphonated reduction products can be determined by reversed‐phase HPLC/MS with positive‐ion atmospheric pressure chemical ionisation and of the sulphonated products by ion‐pairing HPLC/MS with negative‐ion ESI.  相似文献   

13.
A liquid chromatography–tandem mass spectrometric (LC‐MS/MS) method was developed and validated for the determination of GDC‐0152 in human plasma to support clinical development. The method consisted of a solid‐phase extraction for sample preparation and LC‐MS/MS analysis in the positive ion mode using TurboIonSprayTM for analysis. d7‐GDC‐0152 was used as the internal standard. A linear regression (weighted 1/concentration2) was used to fit calibration curves over the concentration range of 0.02–10.0 ng/mL for GDC‐0152. There were no endogenous interference components in the blank human plasma tested. The accuracy at the lower limit of quantitation was 99.3% with a precision (%CV) of 13.9%. For quality control samples at 0.0600, 2.00 and 8.00 ng/mL, the between‐run %CV was ≤8.64. Between‐run percentage accuracy ranged from 98.2 to 99.6%. GDC‐0152 was stable in human plasma for 363 days at ?20°C and for 659 days at ?70°C storage. GDC‐0152 was stable in human plasma at room temperature for up to 25 h and through three freeze–thaw cycles. In whole blood, GDC‐0152 was stable for 12 h at 4°C and at ambient temperature. This validated LC‐MS/MS method for determination of GDC‐0152 was used to support clinical studies. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

14.
Homogeneous antibody–drug conjugates (ADCs), generated by site‐specific toxin linkage, show improved therapeutic indices with respect to traditional ADCs. However, current methods to produce site‐specific conjugates suffer from low protein expression, slow reaction kinetics, and low yields, or are limited to particular conjugation sites. Here we describe high yielding expression systems that efficiently incorporate a cyclopropene derivative of lysine (CypK) into antibodies through genetic‐code expansion. We express trastuzumab bearing CypK and conjugate tetrazine derivatives to the antibody. We show that the dihydropyridazine linkage resulting from the conjugation reaction is stable in serum, and generate an ADC bearing monomethyl auristatin E that selectively kills cells expressing a high level of HER2. Our results demonstrate that CypK is a minimal bioorthogonal handle for the rapid production of stable therapeutic protein conjugates.  相似文献   

15.
We present the MALDI‐TOF/TOF‐MS analyses of various hapten–bovine serum albumin (BSA) neoglycoconjugates obtained by squaric acid chemistry coupling of the spacer‐equipped, terminal monosaccharide of the O‐specific polysaccharide of Vibrio cholerae O1, serotype Ogawa, to BSA. These analyses allowed not only to calculate the molecular masses of the hapten–BSA neoglycoconjugates with different hapten–BSA ratios (4.3, 6.6 and 13.2) but, more importantly, also to localize the covalent linkages (conjugation sites) between the hapten and the carrier protein. Determination of the site of glycation was based on comparison of the MALDI‐TOF/TOF‐MS analysis of the peptides resulting from the digestion of BSA with similar data resulting from the digestion of BSA glycoconjugates, followed by sequencing by MALDI‐TOF/TOF‐MS/MS of the glycated peptides. The product‐ion scans of the protonated molecules were carried out with a MALDI‐TOF/TOF‐MS/MS tandem mass spectrometer equipped with a high‐collision energy cell. The high‐energy collision‐induced dissociation (CID) spectra afforded product ions formed by fragmentation of the carbohydrate hapten and amino acid sequences conjugated with fragments of the carbohydrate hapten. We were able to identify three conjugation sites on lysine residues (Lys235, Lys437 and Lys455). It was shown that these lysine residues are very reactive and bind lysine specific reagents. We presume that these Lys residues belong to those that are considered to be sterically more accessible on the surface of the tridimensional structure. The identification of the y‐series product ions was very useful for the sequencing of various peptides. The series of a‐ and b‐product ions confirmed the sequence of the conjugated peptides. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

16.
Gynura procumbens (Lour.) Merr. is traditionally used as a raw material for making dumplings or steamed stuffed buns, and its fresh leaves are boiled with water for tea. Herein, we established an ultra‐high–performance liquid chromatography–quadrupole time‐of‐flight mass spectrometry (UHPLC–Q‐TOF–MS/MS) combined with characteristic ion filtration (CIF) strategy to rapidly screen active ingredients with antioxidant and anti‐inflammatory properties in G. procumbens. This strategy involved screening the active part of G. procumbens using antioxidation and anti‐inflammatory activity assays; discovering the active compounds by speculating on the active site's chemical composition by UHPLC–Q‐TOF–MS/MS plus CIF; and verifying the active compounds' activities. The ethyl acetate extract (EEAF) of G. procumbens was the major active site. Eighty‐one compounds were identified from the EEAF using UHPLC–Q‐TOF–MS/MS plus CIF. Furthermore, polyphenols such as cynarine, isochlorogenic acids A and isochlorogenic acids C have excellent antioxidizing and anti‐inflammatory activities. This study provides a practical strategy for rapid in vitro screening of the antioxidizing and anti‐inflammatory activities of traditional vegetables and herbs and identification of active ingredients.  相似文献   

17.
MMAE is a potent antimitotic drug used as payload of an antibody-drug conjugate which shows potent activity in preclinical and clinical studies against a range of lymphomas, leukemia and solid tumors. Liquid chromatography-high resolution mass spectrometric method was developed for the quantification of MMAE and its preclinical pharmacokinetics. The method consisted of protein precipitation using acetonitrile (ACN) for sample preparation and liquid chromatography – quadrupole – time-of-flight – tandem mass spectrometry (LC-qTOF-MS/MS) analysis in the positive ion mode. A quadratic regression (weighted 1/concentration2), with an equation y = ax2 + bx + c, was used to fit calibration curves over the concentration range of 1.01–2,200 ng/mL for MMAE. The qualification run met the acceptance criteria of ±25% accuracy and precision values for QC samples. Recovery was 42.84%. The dilution integrity was determined for 5-fold dilution and the accuracy and precision ranged within ±25%. The stability results indicated that MMAE was stable for the following conditions: short-term (4 h), long-term (4 weeks), freeze/thaw (3 cycles) and post-preparative stability (12 h). This qualified method was successfully applied to a pharmacokinetic study of MMAE in rat as a preclinical animal model. The PK results suggest that MMAE has moderate CL and low BA.Also, these results would be helpful in having a comprehensive understanding of the PK characteristics of MMAE and developing ADC in future.  相似文献   

18.
The thermal stability of several commonly used crystalline matrix‐assisted ultraviolet laser desorption/ionization mass spectrometry (UV‐MALDI‐MS) matrices, 2,5‐dihydroxybenzoic acid (gentisic acid; GA), 2,4,6‐trihydroxyacetophenone (THA), α‐cyano‐4‐hydroxycinnamic acid (CHC), 3,5‐dimethoxy‐4‐hydroxycinnamic acid (sinapinic acid; SA), 9H‐pirido[3,4‐b]indole (nor‐harmane; nor‐Ho), 1‐methyl‐9H‐pirido[3,4‐b]indole (harmane; Ho), perchlorate of nor‐harmanonium ([nor‐Ho + H]+) and perchlorate of harmanonium ([Ho + H]+) was studied by heating them at their melting point and characterizing the remaining material by using different MS techniques [electron ionization mass spectrometry (EI‐MS), ultraviolet laserdesorption/ionization‐time‐of‐flight‐mass spectrometry (UV‐LDI‐TOF‐MS) and electrospray ionization‐time‐of‐flight‐mass spectrometry (ESI‐TOF‐MS)] as well as by thin layer chromatography analysis (TLC), electronic spectroscopy (UV‐absorption, fluorescence emission and excitation spectroscopy) and 1H nuclear magnetic resonance spectroscopy (1H‐NMR). In general, all compounds, except for CHC and SA, remained unchanged after fusion. CHC showed loss of CO2, yielding the trans‐/cis‐4‐hydroxyphenylacrilonitrile mixture. This mixture was unambiguously characterized by MS and 1H‐NMR spectroscopy, and its sublimation capability was demonstrated. These results explain the well‐known cluster formation, fading (vanishing) and further recovering of CHC when used as a matrix in UV‐MALDI‐MS. Commercial SA (SA 98%; trans‐SA/cis‐SA 5 : 1) showed mainly cis‐ to‐trans thermal isomerization and, with very poor yield, loss of CO2, yielding (3′,5′‐dimethoxy‐4′‐hydroxyphenyl)‐1‐ethene as the decarboxilated product. These thermal conversions would not drastically affect its behavior as a UV‐MALDI matrix as happens in the case of CHC. Complementary studies of the photochemical stability of these matrices in solid state were also conducted. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

19.
Carbapenems show recognized instability in aqueous solutions; therefore some care must be taken in their handling and preparation and their use in the hospital environment. The stability and degradation products of imipenem were investigated from conditions that simulate its clinical use. For this, a simple stability‐indicating method by HPLC‐DAD was validated with a focus on the quantitation of drug concentration remaining from infusion solutions (sodium chloride 0.9% and glucose 5%). The degradation products formed were identified by high‐resolution mass spectrometry (ESI‐Q‐TOF‐MS/MS), with detection of the [M + H]+ ions at m/z 318 (DP‐1), m/z 599 (DP‐2) and m/z 658 (DP‐3). The most probable elemental compositions were obtained with a high degree of confidence, where the error between the masses observed and calculated was 1.25 ppm for DP‐1, ?0.33 ppm for DP‐2 and 1.82 ppm for DP‐3. The DP‐1 degradation product resulted from cleavage of the β‐lactam ring; DP‐2 corresponded to the drug dimer; and DP‐3 was generated from the interaction between imipenem and cilastatin. The proposed method provides a safe and reliable alternative for the quantitation of imipenem, and the stability data obtained by ESI‐Q‐TOF help in understanding the drug behavior under the conditions of clinical use.  相似文献   

20.
A rapid and sensitive LC–MS/MS method with good accuracy and precision was developed and validated for the pharmacokinetic study of quercetin‐3‐O‐β‐d ‐glucopyranosyl‐7‐O‐β‐d ‐gentiobioside (QGG) in Sprague–Dawley rats. Plasma samples were simply precipitated by methanol and then analyzed by LC–MS/MS. A Venusil® ASB C18 column (2.1 × 50 mm, i.d. 5 μm) was used for separation, with methanol–water (50:50, v/v) as the mobile phase at a flow rate of 300 μL/min. The optimized mass transition ion‐pairs (m/z) for quantitation were 787.3/301.3 for QGG, and 725.3/293.3 for internal standard. The linear range was 7.32–1830 ng/mL with an average correlation coefficient of 0.9992, and the limit of quantification was 7.32 ng/mL. The intra‐ and inter‐day precision and accuracy were less than ±15%. At low, medium and high quality control concentrations, the recovery and matrix effect of the analyte and IS were in the range of 89.06–92.43 and 88.58–97.62%, respectively. The method was applied for the pharmacokinetic study of QGG in Sprague–Dawley rats. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号