首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 250 毫秒
1.
The potential of high‐precision calcium and lead isotope ratio measurements using laser ablation coupled to multicollector inductively coupled plasma mass spectrometry (LA‐MC‐ICP‐MS) to aid distinction between four genuine and five counterfeit pharmaceutical packaging samples and further classification of counterfeit packaging samples has been evaluated. We highlight the lack of reference materials for LA‐MC‐ICP‐MS isotope ratio measurements in solids. In this case the problem is minimised by using National Institute of Standards and Technology Standard Reference Material (NIST SRM) 915a calcium carbonate (as solid pellets) and NIST SRM610 glass disc for sample bracketing external standardisation. In addition, a new reference material, NIST SRM915b calcium carbonate, has been characterised in‐house for Ca isotope ratios and is used as a reference sample. Significant differences have been found between genuine and counterfeit samples; the method allows detection of counterfeits and aids further classification of packaging samples. Typical expanded uncertainties for measured‐corrected Ca isotope ratio values (43Ca/44Ca and 42Ca/44Ca) were found to be below 0.06% (k = 2, 95% confidence) and below 0.2% for measured‐corrected Pb isotope ratios (207Pb/206Pb and 208Pb/206Pb). This is the first time that Ca isotope ratios have been measured in packaging materials using LA coupled to a multicollector (MC)‐ICP‐MS instrument. The use of LA‐MC‐ICP‐MS for direct measurement of Ca and Pb isotopic variations in cardboard/ink in packaging has definitive potential to aid counterfeit detection and classification. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

2.
Despite the large number of successful applications of laser ablation, elemental and isotopic fractionation coupled to inductively coupled plasma mass spectrometry (ICP-MS) remain as the main limitations for many applications of this technique in the fields of analytical chemistry and Earth Sciences. A substantial effort has been made to control such fractionations, which are well-established features of nanosecond laser ablation systems. Technological advancements made over the past decade now allow the ablation of solids by femtosecond laser pulses in the deep ultraviolet (UV) region at wavelengths less than 200 nm. Here the use of femtosecond laser ablation and its effects on elemental and isotopic fractionation is investigated. The Pb/U system is used to illustrate elemental fractionation and stable Fe isotopes are used to illustrate isotopic fractionation. No elemental fractionation is observed beyond the precision of the multiple-collector inductively coupled plasma mass spectrometry (MC-ICP-MS) measurements. Without a matrix match between standard and sample, elemental fractionation is absent even when using different laser ablation protocols for standardization and samples (spot versus raster). Furthermore, we found that laser ablation-induced isotope ratio drifts, commonly observed during nanosecond laser ablation, are undetectable during ultraviolet femtosecond laser ablation. So far the precision obtained for Fe isotope ratio determinations is 0.1‰ (2 standard deviation) for the 56Fe/54Fe ratio. This is close to that obtainable by solution multiple-collector inductively coupled plasma mass spectrometry. The accuracy of the results appears to be independent of the matrix used for standardization. The resulting smaller particle sizes reduce fractionation processes. Femtosecond laser ablation carries the potential to solve some of the difficulties encountered during the two prior decades since the introduction of laser ablation.  相似文献   

3.
The use of stable isotope labelled glucose provides insight into glucose metabolism. The 13C‐isotopic enrichment of glucose is usually measured by gas chromatography/mass spectrometry (GC/MS) or gas chromatography/combustion/isotope ratio mass spectrometry (GC/C/IRMS). However, in both techniques the samples must be derivatized prior to analysis, which makes sample preparation more labour‐intensive and increases the uncertainty of the measured isotopic composition. A novel method for the determination of isotopic enrichment of glucose in human plasma using liquid chromatography/isotope ratio mass spectrometry (LC/IRMS) has been developed. Using this technique, for which hardly any sample preparation is needed, we showed that both the enrichment and the concentration could be measured with very high precision using only 20 µL of plasma. In addition, a comparison with GC/MS and GC/IRMS showed that the best performance was achieved with the LC/IRMS method making it the method of choice for the measurement of 13C‐isotopic enrichment in plasma samples. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

4.
Stable metal (e.g. Li, Mg, Ca, Fe, Cu, Zn, and Mo) and metalloid (B, Si, Ge) isotope ratio systems have emerged as geochemical tracers to fingerprint distinct physicochemical reactions. These systems are relevant to many Earth Science questions. The benefit of in situ microscale analysis using laser ablation (LA) over bulk sample analysis is to use the spatial context of different phases in the solid sample to disclose the processes that govern their chemical and isotopic compositions. However, there is a lack of in situ analytical routines to obtain a samples' stable isotope ratio together with its chemical composition. Here, we evaluate two novel analytical routines for the simultaneous determination of the chemical and Si stable isotope composition (δ30Si) on the micrometre scale in geological samples. In both routines, multicollector inductively coupled plasma mass spectrometry (MC-ICP-MS) is combined with femtosecond-LA, where stable isotope ratios are corrected for mass bias using standard-sample-bracketing with matrix-independent calibration. The first method is based on laser ablation split stream (LASS), where the laser aerosol is split and introduced simultaneously into both the MC-ICP-MS and a quadrupole ICP-MS. The second method is based on optical emission spectroscopy using direct observation of the MC-ICP-MS plasma (LA-MC-ICP-MS|OES). Both methods are evaluated using international geological reference materials. Accurate and precise Si isotope ratios were obtained with an uncertainty typically better than 0.23‰, 2SD, δ30Si. With both methods major element concentrations (e.g., Na, Al, Si, Mg, Ca) can be simultaneously determined. However, LASS-ICP-MS is superior over LA-MC-ICP-MS|OES, which is limited by its lower sensitivity. Moreover, LASS-ICP-MS offers trace element analysis down to the μg g−1-range for more than 28 elements due to lower limits of detection, and with typical uncertainties better than 15%. For in situ simultaneous stable isotope measurement and chemical composition analysis LASS-ICP-MS in combination with MC-ICP-MS is the method of choice.  相似文献   

5.
A quadrupole inductively coupled plasma mass spectrometer (Q-ICP-MS) has been used for determination of lead in plant materials using isotope-dilution inductively coupled plasma mass spectrometry. The accuracy of the method was demonstrated by analysis of a matrix certified reference material, NIST SRM 1547 Peach Leaves. Specific instrumental parameters of Q-ICP-MS, including isotope analysis mode, integration time per point, number of points per mass, and number of measurements, were optimized to obtain the best measurement precision. The precision (expressed as relative standard deviation) associated with replicate measurement of the 208Pb/206Pb isotope ratio and its mass-bias correction factor was <0.2%. Following “Example A7” of the Eurachem/CITAC Guide, the relative expanded uncertainty, U rel, (coverage factor k = 2) was found to be ±1.1%, which fulfilled the target value of ±2% maximum and was lower than the uncertainty of ±3.4% reported by NIST based on isotope-dilution thermal ionization mass spectrometry. Sample recovery of 99% was obtained.  相似文献   

6.
An inductively coupled plasma quadrupole mass spectrometer equipped with an octopole collision/reaction cell was used for the determination of cadmium in oyster tissue samples using isotope dilution inductively coupled plasma mass spectrometry. The oyster samples in question were found to contain Mo and Zr. In our feasibility study on a Cd standard solution (10 μg L−1) containing a matrix of Mo (1000 μg L−1) or Zr (250 μg L−1), the potentially interfering species (MoO+ or ZrO+) present at the analytical mass of cadmium concerned (m/z 111, 112 or 114) was reduced effectively through the use of a mixture of He and H2 as cell gases. The accuracy of the method was validated by the analysis of a matrix-matched certified reference material (CRM) of NIST SRM 1566b. The CRM was analyzed under the standard and He/H2 cell modes. Two isotopic pairs of 114Cd/111Cd and 112Cd/111Cd were selected for quantification purposes. The recoveries of cadmium obtained in the two cell modes were compared with each other. The validated method was applied successfully to the APMP.QM-P5 pilot study for international comparability purposes.  相似文献   

7.
An analytical technique utilizing a near‐field effect (to enhance the incident light energy on the thin tip of an Ag needle) in a laser ablation inductively coupled plasma mass spectrometry (NF‐LA‐ICP‐MS) procedure was developed. To produce the thin needles with a tip diameter in the hundreds of nm range a robust needle etching procedure was established. The ‘sample‐to‐tip’ distance was controlled via the measurement of a tunnel current between the needle and sample surface. The NF‐LA‐ICP‐MS technique thus developed was applied for the analysis of copper isotopic standard reference material NIST SRM 976 and tungsten‐molybdenum alloy NIST SRM 480 in the nm resolution range. The observed craters ranged from 200 nm to about 2 µm in diameter and were dependent on the needle used as well as on the ‘sample‐to‐tip’ distance. The mass spectrometric measurements of 63Cu+ ion intensity on NIST SRM 976 showed that using near‐field enhancement in laser ablation allowed a roughly 6‐fold increase in the ion intensity of the analyte when the needle was about 100 nm (and below) from the surface, in contrast to when it was far away (e.g. 10 µm) from the sample. The relative standard deviation (RSD) of the 65Cu+/63Cu+ isotopic ratio measurements by NF‐LA‐ICP‐MS was 3.9% (n = 9). The detection efficiencies obtained for the compared LA‐ICP‐MS and NF‐LA‐ICP‐MS methods were found to be 4.6 * 10?3 counts per second (cps)/ablated atom and 2.7 * 10?5 cps/ablated atom, respectively. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

8.
Three lacquer trays decorated with wisteria vine (rattan) produced in the 18–19th century in Ryukyu Kingdom were analyzed by cross‐section, pyrolysis gas chromatography/mass spectrometry, strontium isotope ratios (87Sr/86Sr), radioactive carbon‐14 dating, and field emission scanning electron microscope with energy dispersive X‐ray spectrometry. One sample had only one red lacquer layer, and the other two samples had two layers with top red lacquer and a bottom layer of natural lacquer, respectively. The 87Sr/86Sr isotope ratios of three samples were 0.7091–0.7107, consistent with that of the Japanese mainland (<0.7110). The wood species of lacquer objects were identified as Japanese white pine, Japanese cedar, and Cunninghamia lanceolata, which grow in the Japanese islands. The carbon‐14 dating results showed that the lacquer films were about 1719–1785. In pyrolysis gas chromatography/mass spectrometry, 3‐heptylphenol (C7) and 3‐pentadecylphenol (C15) were detected in the mass chromatograms at m/z = 108 and palmitic acid and stearic acid were detected in the mass chromatograms at m/z = 60, implying that the coating material was sap collected from Toxicodendron vernicifluum lacquer tree and included a drying oil. Energy dispersive X‐ray spectrometry revealed that mainly mercury sulfide was used as red pigment in these three Ryukyu lacquerwares. Copyright © 2017 John Wiley & Sons, Ltd.  相似文献   

9.

Rationale

Li and Mg isotopes are increasingly used as a combined tool within the geosciences. However, established methods require separate sample purification protocols utilising several column separation procedures. This study presents a single‐step cation‐exchange method for quantitative separation of trace levels of Li and Mg from multiple sample matrices.

Methods

The column method utilises the macro‐porous AGMP‐50 resin and a high‐aspect ratio column, allowing quantitative separation of Li and Mg from natural waters, sediments, rocks and carbonate matrices following the same elution protocol. High‐precision isotope determination was conducted by multi‐collector inductively coupled plasma mass spectrometry (MC‐ICPMS) on the Thermo Scientific™ NEPTUNE Plus™ fitted with 1013 Ω amplifiers which allow accurate and precise measurements at ion beams ≤0.51 V.

Results

Sub‐nanogram Li samples (0.3–0.5 ng) were regularly separated (yielding Mg masses of 1–70 μg) using the presented column method. The total sample consumption during isotopic analysis is <0.5 ng Li and <115 ng Mg with long‐term external 2σ precisions of ±0.39‰ for δ7Li and ±0.07‰ for δ26Mg. The results for geological reference standards and seawater analysed by our method are in excellent agreement with published values despite the order of magnitude lower sample consumption.

Conclusions

The possibility of eluting small sample masses and the low analytical sample consumption make this method ideal for samples of limited mass or low Li concentration, such as foraminifera, mineral separates or dilute river waters.
  相似文献   

10.
The potential effect of spectral interference on the accurate measurement of the cadmium (Cd) mass fraction in fortified breakfast cereal and a variety of dietary supplement materials using inductively coupled plasma quadrupole mass spectrometry was studied. The materials were two new standard reference materials (SRMs)—SRM 3233 Fortified Breakfast Cereal and SRM 3532 Calcium Dietary Supplement—as well as several existing materials—SRM 3258 Bitter Orange Fruit, SRM 3259 Bitter Orange Extract, SRM 3260 Bitter Orange-containing Solid Oral Dosage Form, and SRM 3280 Multivitamin/Multielement Tablets. Samples were prepared for analysis using the method of isotope dilution and measured using various operating and sample introduction configurations including standard mode, collision cell with kinetic energy discrimination mode, and standard mode with sample introduction via a desolvating nebulizer system. Three isotope pairs, 112Cd/111Cd, 113Cd/111Cd, and 114Cd/111Cd, were measured. Cadmium mass fraction results for the unseparated samples of each material, measured using the three instrument configurations and isotope pairs, were compared to the results obtained after the matrix was removed via chemical separation using anion exchange chromatography. In four of the six materials studied, measurements using the standard mode with sample introduction via the desolvating nebulizer gave results for the unseparated samples quantified with the 112Cd/111Cd isotope pair that showed a positive bias relative to the matrix-separated samples, which indicated a persistent inference at m/z?112 with this configuration. Use of the standard mode, without the desolvating nebulizer, also gave results that showed a positive bias for the unseparated samples quantified with the 112Cd/111Cd isotope pair in three of the materials studied. Collision cell/kinetic energy discrimination mode, however, was very effective for reducing spectral interference for Cd in all of the materials and isotope pairs studied, except in the multivitamin/multielement matrix (SRM 3280) where the large corrections for known isobaric interferences or unidentified interferences compromised the accuracy. For SRM 3280, matrix separation provided the best method to achieve accurate measurement of Cd.  相似文献   

11.
This paper reviews the problems encountered in eleven studies of Sr isotope analysis using laser ablation multicollector inductively coupled plasma mass spectrometry (LA-MC-ICPMS) in the period 1995–2006. This technique has been shown to have great potential, but the accuracy and precision are limited by: (1) large instrumental mass discrimination, (2) laser-induced isotopic and elemental fractionations and (3) molecular interferences. The most important isobaric interferences are Kr and Rb, whereas Ca dimer/argides and doubly charged rare earth elements (REE) are limited to sample materials which contain substantial amounts of these elements. With modern laser (193 nm) and MC-ICPMS equipment, minerals with >500 ppm Sr content can be analysed with a precision of better than 100 ppm and a spatial resolution (spot size) of approximately 100 μm. The LA MC-ICPMS analysis of 87Sr/86Sr of both carbonate material and plagioclase is successful in all reported studies, although the higher 84Sr/86Sr ratios do suggest in some cases an influence of Ca dimer and/or argides. High Rb/Sr (>0.01) materials have been successfully analysed by carefully measuring the 85Rb/87Rb in standard material and by applying the standard-sample bracketing method for accurate Rb corrections. However, published LA-MC-ICPMS data on clinopyroxene, apatite and sphene records differences when compared with 87Sr/86Sr measured by thermal ionisation mass spectrometry (TIMS) and solution MC-ICPMS. This suggests that further studies are required to ensure that the most optimal correction methods are applied for all isobaric interferences.  相似文献   

12.
A simple and inexpensive laboratory-built vapor generator was used with inductively coupled plasma mass spectrometry (ICP-MS) for the determination of mercury in urine and seawater samples. The applications of vapor generation ICP-MS alleviated the non-spectroscopic interferences and the sensitivity problem of mercury determination encountered when the conventional pneumatic nebulizer was used for sample introduction. The concentration of mercury was determined by isotope dilution method. The isotope ratio of mercury was calculated from the peak areas of each injection peak. The repeatability of the peak areas and isotope ratio determinations of seven consecutive injections of 1 ng mL?1 Hg solution were 2.3% and 2.2%, respectively. This method has a detection limit of 0.07 ng mL?1 for mercury. This method was applied to determine mercury in a CASS-3 nearshore seawater reference sample, NASS-4 open ocean seawater reference sample, NIST SRM 2670 freeze-dried urine reference sample and several urine and seawater samples collected from National Sun Yat-Sen University. The results for the reference samples agreed satisfactorily with the reference values. Results for other samples analyzed by the isotope dilution method and the method of standard additions agreed satisfactorily. Precision was better than 10% for most of the determinations.  相似文献   

13.
Isotope pattern deconvolution is a mathematical technique for isolating distinct isotope signatures from mixtures of natural abundance and enriched tracers. In iron metabolism studies measurement of all four isotopes of the element by high-resolution multicollector or collision cell ICP–MS allows the determination of the tracer/tracee ratio with simultaneous internal mass bias correction and lower uncertainties. This technique was applied here for the first time to study iron uptake by cucumber plants using 57Fe-enriched iron chelates of the o,o and o,p isomers of ethylenediaminedi(o-hydroxyphenylacetic) acid (EDDHA) and ethylenediamine tetraacetic acid (EDTA). Samples of root, stem, leaves, and xylem sap, after exposure of the cucumber plants to the mentioned 57Fe chelates, were collected, dried, and digested using nitric acid. The isotopic composition of iron in the samples was measured by ICP–MS using a high-resolution multicollector instrument. Mass bias correction was computed using both a natural abundance iron standard and by internal correction using isotope pattern deconvolution. It was observed that, for plants with low 57Fe enrichment, isotope pattern deconvolution provided lower tracer/tracee ratio uncertainties than the traditional method applying external mass bias correction. The total amount of the element in the plants was determined by isotope dilution analysis, using a collision cell quadrupole ICP–MS instrument, after addition of 57Fe or natural abundance Fe in a known amount which depended on the isotopic composition of the sample.  相似文献   

14.
The paper describes a new high-precision method for the simultaneous precise determination of 88Sr/86Sr and 87Sr/86Sr ratios in a single portion of a geological sample by multicollector inductively coupled mass spectrometry (MC-ICP-MS). The isotope analysis is carried out with mass bias effect correction by a combination of internal normalization to the standard Zr-isotope ratio and bracketing standard method (external normalization). Our results for geochemical IAPSO and BCR-1 standard samples are in a good agreement with the published data. The reproducibility of the 88Sr/86Sr ratio varies from ±0.015 to ±0.05?? (depending on the sample features) and, together with the analysis accuracy, is superior to the previously reported methods of MC-ICP-MS analysis. Still ahead is only double spike thermal ionization mass spectrometry with its ±0.02?? reproducibility. However, the new method allows the simultaneous determination of 88Sr/86Sr and 87Sr/86Sr ratios and its productivity is higher by 5 to 6 times. On the other hand, in sample preparation, it is necessary to strive for at least 95% Sr yield from the chromatographic column; otherwise the sorption-desorption process may lead to a 0.6?? 88Sr/86Sr ratio bias relative to the true value.  相似文献   

15.
A rapid, accurate and less labor intensive approach to determining 226Ra in environmental samples was examined; this utilized quadrupole-based inductively coupled plasma mass spectrometry (ICP-QMS). The procedure used chemical separation by ion exchange chromatography to remove most of the matrices after coprecipitation with BaSO4. The average chemical recovery of the NIST SRM preparation method ranged from 60.5 to 85.9% using 133Ba as internal tracer by gamma counting. This technique was capable of completing a 226Ra measurement within 3 min. It did not require an in-growth period to allow radon and its progeny to achieve secular equilibrium with the parent 226Ra as is needed for liquid scintillation analyzer (LSA). The method detection limits for the determination of 226Ra in geothermal water and sediment samples were 0.02 mBq L−1 (0.558 fg L−1) and 0.10 Bq kg−1 (2.79 fg g−1), respectively. The results obtained with various natural samples and the suitability of the method when applied to various environmental matrices such as geothermal water and sediment are discussed. When ICP-QMS was compared to double-focusing magnetic sector field inductively coupled plasma mass spectrometry (ICP-SFMS), good agreement was obtained with a correlation coefficient, r 2 = 0.982.  相似文献   

16.
A new facile magnetic micro‐solid‐phase extraction coupled to gas chromatography and mass spectrometry detection was developed for the extraction and determination of selected antidepressant drugs in biological fluids using magnetite‐MCM‐41 as adsorbent. The synthesized sorbent was characterized by several spectroscopic techniques. The maximum extraction efficiency for extraction of 500 μg/L antidepressant drugs from aqueous solution was obtained with 15 mg of magnetite‐MCM‐41 at pH 12. The analyte was desorbed using 100 μL of acetonitrile prior to gas chromatography determination. This method was rapid in which the adsorption procedure was completed in 60 s. Under the optimized conditions using 15 mL of antidepressant drugs sample, the calibration curve showed good linearity in the range of 0.05–500 μg/L (r 2 = 0.996–0.999). Good limits of detection (0.008–0.010 μg/L) were obtained for the analytes with good relative standard deviations of <8.0% (n  = 5) for the determination of 0.1, 5.0, and 500.0 μg/L of antidepressant drugs. This method was successfully applied to the determination of amitriptyline and chlorpromazine in plasma and urine samples. The recoveries of spiked plasma and urine samples were in the range of 86.1–115.4%. Results indicate that magnetite micro‐solid‐phase extraction with gas chromatography and mass spectrometry is a convenient, fast, and economical method for the extraction and determination of amitriptyline and chlorpromazine in biological samples.  相似文献   

17.
An important but commercially unavailable compound isotopically enriched monoethylmercury chloride (C2H5201HgCl), has been synthesized from commercially available 201HgO (98.11% enriched isotopic purity) and tetraethyltin. The required synthesis time is 1 h at 90 °C, and the product is the single product of monoethylmercury chloride, yielding more than 95% as 201Hg in C2H5201Hg+ (98.19 ± 0.22% enriched isotopic purity). The synthesized product was analyzed with high‐performance liquid chromatography coupled with inductively coupled plasma mass spectrometry (HPLC‐ICP‐MS) to determine its concentration, isotopic composition and purity. The synthetic isotopically enriched monoethylmercury synthesized can be used in speciated isotope dilution mass spectrometry (SIDMS) and isotope dilution mass spectrometry (IDMS) analyses as a standard. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

18.
Strontium-90 is one of the most important fission products generated in nuclear industry. In the research field concerning nuclear waste disposal in deep geological environment, it is necessary to quantify accurately and precisely its concentration (or the 90Sr / 238U atomic ratio) in irradiated fuels. To obtain accurate analysis of radioactive 90Sr, mass spectrometry associated with isotope dilution is the most appropriated method. But, in nuclear fuel samples the interference with 90Zr must be previously eliminated. An inductively coupled plasma mass spectrometer with multiple collection, equipped with an hexapole collision cell, has been used to eliminate the 90Sr / 90Zr interference by addition of oxygen in the collision cell as a reactant gas. Zr+ ions are converted into ZrO+, whereas Sr+ ions are not reactive.A mixed solution, prepared from a solution of enriched 84Sr and a solution of enriched 235U was then used to quantify the 90Sr / 238U ratio in spent fuel sample solutions using the double isotope dilution method. This paper shows the results, the reproducibility and the uncertainties that can be obtained with this method to quantify the 90Sr / 238U atomic ratio in an UOX (uranium oxide) and a MOX (mixed oxide) spent fuel samples using the collision cell of an inductively coupled plasma mass spectrometer with multiple collection to perform the 90Sr / 90Zr separation. A comparison with the results obtained by inductively coupled plasma mass spectrometer with multiple collection after a chemical separation of strontium from zirconium using a Sr spec resin (Eichrom) has been performed. Finally, to validate the analytical procedure developed, measurements of the same samples have been performed by thermal ionization mass spectrometry, used as an independent technique, after chemical separation of Sr.  相似文献   

19.
Isotope ratio monitoring gas chromatography‐mass spectrometry of the 2H/1H ratio by pyrolysis isotope ratio mass spectrometry (P‐IRMS) was used to analyze benzaldehyde originating from various sources. Based on the δ2HSMOW value of an authentic reference sample determined with an elemental analyzer (EA), the range of reproducibility and linearity was checked. Correct (EA related) and reproducible data were obtained for sample amounts >0.6 μg benzaldehyde (on column). In another series of experiments, the influence of sample preparation, i. e. simultaneous distillation‐extraction (SDE) was found to be negligible. The following ranges of δ2HSMOW values were determined for benzaldehyde using five types of samples, i. e. (i) synthetic (δ2HSMOW –78 to –85‰, ex benzal chloride; +420 to +668‰, ex toluene) and ‘natural’ (including ‘ex‐cassia’) references (δ2HSMOW –83 to –144‰); (ii) bitter almond oils (δ2HSMOW –113 to –148‰); (iii) fruits (δ2HSMOW –111 to –146‰); (iv) kernels (δ2HSMOW –115 to –188‰); and (v) leaves (δ2HSMOW –165 to –189‰).  相似文献   

20.
Samples of glass used as trace evidence in criminal cases are commonly small, with particle sizes below a millimeter. To perform chemical analysis suitable for forensic purposes, methods capable of analyzing such small samples are required.In this paper, analyses of lead isotope ratios by means of laser ablation inductively coupled multicollector mass spectrometry (LA-MC-ICP-MS) are presented. Sampling by use of laser ablation allows fragments down to 0.1 mg to be analyzed with sufficient precision to discriminate between glasses of different origin. In fact, the use of lead isotopes determined by LA-MC-ICP-MS approaches the discrimination attainable by multicollector inductively coupled plasma mass spectrometry (MC-ICP-MS) analysis of dissolved samples of 5 mg or more.Further, we have obtained a probability distribution by two dimensional kernel density estimates for the collected data set as an alternative presentation method to the well-established bivariate plot. The underlying information available from kernel density estimates is of importance for forensic scientists involved in probabilistic interpretation of physical evidence.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号