首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Myung SW  Yoon SH  Kim M 《The Analyst》2003,128(12):1443-1446
An automated LPME device for a dynamic LPME method was manufactured and its extraction efficiency was tested using spiked urine samples. The developed home-made LPME device was a programmable automated syringe dispenser to overcome deteriorating precision and difficulties in manually manipulating the plunger repeatedly. To establish the optimum parameters for benzene ethylamines, the effects of sampling volume, solvent volume, pH, salt-effect, choice of solvents, plunger speed, and number of samplings were investigated. Good repeatabilities for the extraction of mephentermine, ephedrine, methoxyphenamine, selegiline, and bupropion were obtained and the RSD values were 2.4, 1.9, 1.3, 1.6 and 1.5% at a concentration of 3 microg mL(-1) in spiked urine samples, respectively. The limit of detection was below 0.05 microg mL(-1) for the investigated drugs. This developed device for LPME analysis gave good validation results and improved convenience.  相似文献   

2.
To overcome the limitations of solid-phase extraction, we developed a device comprising a spin column packed with octadecyl silane-bonded monolithic silica for extracting amphetamines and methylenedioxyamphetamines from urine. Urine (0.5mL), buffer (0.4mL), and methoxyphenamine (internal standard) were directly put into the preactivated column. The column was centrifuged (3000rpm, 5min) for sample loading and washed. The adsorbed analytes were eluted and analyzed by high-performance liquid chromatography, without evaporation. The results were as follows: linear curves (drug concentrations of 0.2-20microg/mL); correlation coefficients >0.99; detection limit, 0.1microg/mL. The proposed method is not only useful for drugs from biological materials but also highly reproducible for the analysis of these drugs in urine.  相似文献   

3.
Methoxyphenamine (o-methoxy-N,alpha-dimethylphenethylamine, Orthoxine) used in earlier times as a bronchodilator is prohibited in sports according to the regulations of the World Anti-Doping Agency (WADA). The drug and several of its metabolites are commonly analysed in doping control screening assays using gas chromatography-mass spectrometry requiring extraction from urine specimens. A complementary method employing liquid chromatography-atmospheric pressure chemical ionisation-tandem mass spectrometry and direct injection of urine aliquots was developed, which provided a fast and sensitive alternative to confirm the presence of the prohibited compound and degradation products in sports drug testing samples. In particular, the chromatographic separation of the active drug from isomeric compounds such as the designer drug p-methoxymetamphetamine (PMMA) was of particular interest to unambiguously identify the applied substance and was accomplished using a C6-phenyl reverse-phase column with isocratic elution. The established procedure was validated for methoxyphenamine with regard to specificity, limit of detection (0.7 ng mL(-1)), intraday- and interday precision (2.5-5.8% and 10.8-16.2%, respectively) and its applicability was demonstrated with an authentic doping control sample which tested positive for the prohibited compound early in 2008.  相似文献   

4.
Sensitive gas chromatographic procedures for the determination of methoxyphenamine and three of its metabolites in plasma have been developed. The metabolites were measured using an electron-capture detector. This simple procedure is based on the precipitation of protein from a 1-ml plasma sample with 10% trichloroacetic acid, followed by aqueous derivatization with pentafluorobenzoyl chloride at pH 9.2 and a single-step cyclohexane extraction. The lower limit of detection for the N-desmethyl, O-desmethyl and aromatic 5-hydroxy metabolites of methoxyphenamine were 1.6, 3.1 and 2.2 ng ml-1, respectively, with coefficients of variation less than 10%. The poor electron-capture response of fluorinated derivatives of methoxyphenamine necessitated the use of nitrogen-phosphorus detection. Extractive derivatization with pentafluorobenzoyl chloride, without the need for protein precipitation, enabled quantitation of methoxyphenamine down to 3.8 ng ml-1 from a 2-ml aliquot of plasma. In a pilot study involving healthy volunteers who received a single oral dose of methoxyphenamine hydrochloride plasma concentration could be followed in all three subjects for at least 24, 32, 12 and 4 h for methoxyphenamine and the O-desmethyl, 5-hydroxy and N-desmethyl metabolites, respectively.  相似文献   

5.
A microchip-based solid-phase extraction method for biological fluid small molecule analysis has been developed. Using a commercially available copolymer packed into a microchip channel, extraction and preconcentration of 2,3-dihydroxybenzoic acid (DHBA) and 2,5-DHBA from saliva was achieved. The metabolites, formed from salicylic acid by reactive oxygen species, can be used as markers of oxidative stress. The results show high recovery of both metabolites (>90+/-15% for spiked saliva) with an 80-fold concentration enhancement possible. The eluent is directly analyzed using capillary electrophoresis, with good resolution for the two metabolites. This study demonstrates the feasibility of future integrated microdevices for spaceflight small molecule biomarker analysis.  相似文献   

6.
Summary A procedure has been developed for the determination, in <12 min, of several stimulants (amphetamine, ephedrine, methoxyphenamine, phenylephrine and phenylpropanolamine) in spiked urine samples after direct injection, using a hybrid micellar mobile phase of 0.15 M sodium dodecyl sulfate and 3% pentanol at pH 7, on a C18 column with UV detection. Recoveries were 94–102% and limits of detection 4.5 ng·mL−1 for methoxyphenamine and 0.39 μg·mL−1 for amphetamine, similar to those obtained for aqueous solutions. Linearity reached 0.99 and intermediate precision was <8.4 and 5.3, for the two different concentrations tested.  相似文献   

7.
Sensitive and enantioselective gas chromatographic assays have been developed and applied to the quantitation in human urine of the enantiomers of methoxyphenamine and its three primary oxidative metabolites, namely, N-desmethylmethoxyphenamine, O-desmethylmethoxyphenamine and 5-hydroxymethoxyphenamine. The separation of the various analytes was achieved through the combined use of high-resolution gas chromatography coupled with electron-capture detection and employing a capillary OV-225 column. The formation of diastereometric derivatives involved the chiral acylating reagent N-heptafluorobutyryl-L-prolyl chloride. The assays for methoxyphenamine and O-desmethylmethoxyphenamine were linear over the range 0.25-2.0 micrograms/ml for each analytes' enantiomers, while in the case of the enantiomers for N-desmethylmethoxyphenamine and 5-hydroxymethoxyphenamine linearity was shown over the ranges 0.094-0.75 and 0.188-1.5 micrograms/ml, respectively. The mean coefficients of variation in all cases were less than 4%.  相似文献   

8.
Microchip analysis is a promising method for therapeutic drug monitoring. This led us to evaluate a microchip-based fluorescence polarization immunoassay (FPIA) system for point-of-care testing on patients being treated with theophylline. The sera were collected from 20 patients being treated with theophylline. Fluorescence polarization was measured on the microchip and theophylline concentrations in serum were obtained. Regression analysis of the correlations was done between the results given by the microchip-based FPIA and the conventional cloned enzyme donor immunoassay (CEDIA), and between the results given by the microchip-based FPIA and the conventional particle-enhanced turbidimetric inhibition immunoassay (PETINIA). We successfully carried out a quantitative analysis of theophylline in serum at values near its therapeutic range in 65 s. The results obtained by the microchip-based FPIA correlated well with CEDIA and PETINIA results; the correlation coefficients (R 2) were 0.986 and 0.989, respectively. The FPIA system is a simple and rapid method for point-of-care testing of drugs in serum, and its accuracy is the same as the conventional CEDIA and PETINIA. It is essential to use real samples from patients and to confirm good correlations with conventional methods for a study on the realization of microchip.  相似文献   

9.
Determination of dialkylphosphates (DAPs) in urine is useful for assessing human exposure to organophosphates (OPs). An improved method for the determination of four DAPs based on a strong anion exchange (SAX) disk extraction and in-vial derivatization was presented in this study. The matrix effect of urine components such as chloride ion and phosphate ion by using a SAX disk to extract DAPs in urine analysis was carefully evaluated. It was observed that the chloride ion mainly affected the extraction of diethylphosphate (DEP), dimethylthiophosphate (DMTP), and diethylthiophosphate (DETP) in urine. The addition of silver hydroxide could significantly improve the extraction efficiencies of these three DAPs, but it decreases the extraction efficiencies of dimethyldithiophosphate (DMDTP) and diethyldithiophosphate (DEDTP). The LOD of this method for DMTP, DETP, DMDTP, and DEDTP are 5, 5, 11, and 5 microg/L, respectively. A pretreatment strategy for the determination of DMTP, DMDTP, DETP, and DEDTP in urine was proposed which can provide reliable and prompt determination of routine urine analysis.  相似文献   

10.
Summary The applicability of multiple solid-phase microextraction to the analysis of biological samples has been shown by extraction of a variety of compounds from human urine. Multiple solid-phase microextraction, in which extraction and desorption are repeated and analytes are collected at the head of the separation system before starting the analysis, has been combined with gas chromatography. Amphetamine, lidocaine, procaine, and mepivacaine were extracted from buffered urine by direct immersion of a 100-μm polydimethylsiloxane-coated fiber, to demonstrate that multiple SPME can be used for analytes with different extraction behavior. Multiple solid-phase microextraction was optimized for high extraction yield or short extraction time. For example, the total sample-handling time (extraction plus desorption) for the extraction of mepivacaine from urine can be reduced from approximately 60 min (one extraction) to 33 min (three extractions) without reducing extraction yield. In addition, the extraction yield for mepivacaine can be increased from 14.6% (one extraction) to 27.0% (five extractions) within the same total sample handling time of approximately 60 min. A good match between theoretical and experimental values was obtained. Chromatograms are shown to illustrate the usefulness of the procedure.  相似文献   

11.
He C  Li S  Liu H  Li K  Liu F 《Journal of chromatography. A》2005,1082(2):143-149
Based on aqueous two-phase systems (ATPS) consisting of 1-butyl-3-methylimidazolium chloride, a hydrophilic ionic liquid (IL), and K2HPO4, a new and simple extraction technique, coupled with a reversed-phase high performance liquid chromatography (RP-HPLC), was developed for the simultaneous concentration and analysis of testosterone (T) and epitestosterone (ET) in human urine. Under the optimal conditions, the extraction efficiencies for both analytes were 80-90% in a one-step extraction. The method required only 3.0 mL of urine and a single hydrolysis/deproteinization/extraction step followed by direct injection of the IL-rich upper phase into HPLC system for analysis. The method has been satisfactorily applied to the analysis of T and ET in human urine with detection limits of 1 ng/mL and linear ranges of 10-500 ng/mL for both compounds. Compared with conventional liquid-liquid extraction or solid phase extraction, this new method is much "greener" due to no use of volatile organic solvent and low consumption of IL. The proposed extraction technique opens up new possibilities in the separation of other drugs.  相似文献   

12.
Both conventional and microchip-based capillary electrophoresis(CE) technologies have been used for the analysis of enzymes. Practical procedures of using CE to determine the Km and Vmax values of an enzyme have been developed. By studying the inhibition to the enzyme, it is possible to select a suitable drug candidate. When compared with the conventional CE method, single lane microchip-based method can improve the speed for the assay three times. By using multiple lane-based microchip, the speed can be further increased.  相似文献   

13.
A rapid, sensitive and automated in-tube solid-phase microextraction-liquid chromatography-mass spectrometry (in-tube SPME/LC-MS) method was developed for the analysis of ten antidepressants in urine and plasma. A hybrid organic-inorganic silica monolith with cyanoethyl functional groups was prepared and used as a sorbent for in-tube SPME. Integration of the sample extraction, LC separation and MS detection into a single system permitted direct injection of the diluted urine or plasma after filtration. Under the optimized conditions, good extraction efficiencies for the targets were obtained with no matrix interference in the subsequent LC-MS. Automation of the sampling, extraction and separation procedures was realized under the control of a program in this study. The total process time was 30 min and only 30 μL of urine or plasma was required in one analysis cycle. Good linearities were obtained for ten antidepressants with the correlation coefficients (R) above 0.9933. The limits of detection (S/N=3) for ten antidepressants were found to be 0.06-2.84 ng/mL in urine and 0.07-2.95 ng/mL in plasma. The recoveries of antidepressants spiked in urine and plasma were from 75.2% to 113.0%, with relative standard deviations less than 16.5%. The developed method was successfully used to analyze urine sample from ageing patients undergoing therapy with antidepressants.  相似文献   

14.
Su CJ  Srimurugan S  Chen C  Shu HC 《Analytical sciences》2011,27(11):1107-1113
Novel sol-gel titania film coated needles for solid-phase dynamic extraction (SPDE)-GC/MS analysis of desomorphine and desocodeine are described. The high thermal stability of titania film permits efficient extraction and analysis of poorly volatile opiate drugs. The influences of sol-gel reaction time, coating layer, extraction and desorption time and temperature on the SPDE needle performance were investigated. The deuterium labeled internal standard was introduced either during the extraction of analyte or directly injected to GC after the extraction process. The latter method was shown to be more sensitive for the analysis of water and urine samples containing opiate drugs. The proposed conditions provided a wide linear range (from 5-5000 ppb), and satisfactory linearity, with R(2) values from 0.9958 to 0.9999, and prominent sensitivity, LOQs (1.0-5.0 ng/g). The sol-gel titania film coated needle with SPDE-GC/MS will be a promising technique for desomorphine and desocodeine analysis in urine.  相似文献   

15.
Functionalities of microchip-based analytical systems for nucleic acids analysis are highlighted and driving forces for the future progress are reviewed. The review shows the main advantages of microchip-based systems and discusses up-to-date achievements in this area. Among the main advantages are a high speed of analysis, high rates of heating and cooling, a low reagents consumption, and a high potential to integrate several analytical processes in a single microchip device.  相似文献   

16.
We describe a high-performance liquid chromatographic method with electrochemical detection for quantifying pyronaridine in rhesus monkey (Macaca mulata) blood and urine samples. The detection limit is 20 ng/ml at a signal-to-noise ratio of 4 in 0.5-ml samples of blood or urine. Blood analysis includes a liquid-liquid extraction and a subsequent solid-phase extraction that removes an interferent present in blood. For urine, a back-extraction is substituted for the solid-phase extraction step. The method uses an analogue of amodiaquine as internal standard, a 10-microns rigid macroporous styrene-divinylbenzene copolymer column and a mobile phase of 1% (v/v) triethylamine in methanol-water (34:66, v/v). The method was applied to samples of blood and urine from a monkey after a single intramuscular dose of pyronaridine tetraphosphate (160 mg as base).  相似文献   

17.
The cost-effective detection of viral particles in bodily fluids could enable more effective responses to viral outbreaks, whether isolated clinical cases, or influenza epidemics. In renal transplant recipients, complications arising from high levels of BK virus can lead to graft dysfunction, graft loss, and/or reduced patient survival. We describe a microfluidic system for the sensitive analysis of BK virus (viral load) in unprocessed urine samples that are applied directly onto the chip, thus avoiding labor-intensive processing and sources of inter-assay variability. Integration of small volume genetic amplification (PCR) and electrophoretic analysis detects as few as 1-2 viral copies, distinguishes between high, medium and low levels of virus and reliably identifies viral loads requiring clinical intervention. As a first step to wider application in the clinic and in the field, the present work presents an entirely microchip-based system, validated against conventional clinical methods using clinical samples.  相似文献   

18.
Pathogenic bacteria pose a global threat to public health and attract considerable attention in terms of food safety. Rapid and highly sensitive strategies for detecting pathogenic bacteria must be urgently developed to ensure food safety and public health. Microchips offer significant advantages for pathogenic bacterial detection in terms of speed and sensitivity compared with those of traditional techniques. Microfluidic devices, in particular, have attracted significant attention for the dete...  相似文献   

19.
A novel kind of hydrophilic monolith based immobilized enzyme reactors (IMERs) was prepared both in UV-transparent capillaries and on glass microchips by the photopolymerization of N-acryloxysuccinimide and poly(ethylene glycol)diacrylate, followed by trypsin immobilization. The performance of capillary IMERs for protein digestion was evaluated by the digestion of myoglobin with the residential time from 12s to 71 s. With μRPLC-ESI-MS/MS analysis, the obtained sequence coverages were all over 80%, comparable to that obtained by in-solution digestion for 12 h. The nonspecific absorption of BSA on monolithic support was evaluated, and no obvious protein residue was observed by a fluorescence assay. Moreover, no carry-over of the digests on the capillary IMER was found after the digestion of myoglobin (24 μg) and BSA (9 μg), which further demonstrated the good hydrophilicity of such matrix. In addition, an integrated microchip-based system involving on-line protein digestion by microchip-based IMER, peptides separation by nanoRPLC and identification by ESI-MS/MS was established, by which a mixture of standard proteins and one RPLC fraction of Escherichia coli extract were successfully identified, indicating that the hydrophilic monolith based IMER might provide a promising tool for high-throughput proteomic analysis.  相似文献   

20.
A new molecularly imprinted polymer (MIP) has been synthesized for the selective extraction of trans,trans-muconic acid (ttMA) from urine samples, followed by high-performance liquid chromatography analysis with ultraviolet detection. The synthesis was based on non-covalent interactions, and 4-vinylpyridine was used as a functional monomer. The analytical calibration curve was prepared using a pool of five urine samples of non-smokers spiked with ttMA standards with concentrations that ranged from 0.3 to 10 mg L(-1) (r(2) = 0.999). The limit of quantification was 0.3 mg L(-1) (lower than the biological exposure limits suggested by the ACGIH). The within-day and between-day precision and accuracy presented relative standard deviations and relative errors of less than 15%. The analytical frequency was 4 h(-1) (considering extraction and separation/quantification steps), and the same MIP cartridge was efficiently used for approximately 100 cycles. All figures of merit were similar or better than those obtained by the procedure based on ionic exchange extraction. The proposed method could be an interesting alternative for the routine analysis of ttMA in urine for biological monitoring procedures of human exposure to benzene.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号