首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
It is of increasing interest and practical importance to develop convenient methods based on mass spectrometry for high-throughput analyses of biological samples. This is usually difficult because of the complex matrix and ion suppression effects. Generation of ions at ambient conditions is a promising solution to these problems because the sample is easily accessible and the ion suppression effect is reduced significantly. A new method for rapid on-line detection of metabolic markers in complex biological samples is described here. It combines atmospheric pressure desorption sampling by a gentle stream of air or nitrogen with extractive electrospray ionization (EESI) and mass spectrometric analysis. The resulting mass spectral fingerprints are shown to be able to detect spoilage of meat even in the frozen (-20 degrees C) state and the contamination of spinach by E. coli, and to identify metabolites and contaminants on human skin within seconds, in an on-line and high-throughput fashion. Typical molecular markers are identified using MS/MS data and by comparison with reference compounds. Differences between closely related samples are easily visualized by using principal component analysis (PCA) of the mass spectra data. The detection limit achieved is 10 fg/cm2 (S/N = 3) for histamine on the surface of frozen meat. The technique reported here shows potential for more advanced applications in multiple disciplines, including food regulation, homeland security, in vivo metabolomics, and clinical diagnosis.  相似文献   

2.
Hu B  Yang S  Li M  Gu H  Chen H 《The Analyst》2011,136(18):3599-3601
The high-throughput and sensitive characterization of native proteins in biological samples is of increasing interest in multiple disciplines. Extractive electrospray ionization (EESI) forms ions of native proteins including lysozyme, α-chymotrypsin, myoglobin, human serum albumin, RNAse A and blood hemoglobin in extremely complex biosamples or PBS buffer solutions by softly depositing charges on the protein molecules. This method produces no significant conformational changes of the proteins in the ion formation process, and features direct detection of trace proteins present in biological matrices. The detection limit of low pmol L(-1) for lysozyme in untreated biological liquids such as human urine and tears was demonstrated using EESI mass spectrometry (MS), showing an attractive MS platform for the direct analysis of native proteins in actual biological samples.  相似文献   

3.
复杂样品质谱分析技术的原理与应用   总被引:10,自引:1,他引:10  
原位、实时、在线、非破坏、高通量、低耗损的质谱学方法是质谱分析技术发展的重要趋势.在无需样品预处理的条件下对复杂基体样品中痕量待测物直接离子化技术的出现,极大地提高了质谱分析的效率,使实际样品的快速质谱分析成为可能.本文着重综述了能够在无需样品预处理情况下对复杂基体样品离子化的新兴质谱技术及其应用研究,系统阐述了直接离子化技术的基本原理和方法,介绍了几种典型的常压直接离子化技术和装置,对直接离子化质谱分析技术在食品、药品、环境、活体分析、代谢组学、蛋白质组学以及生物组织质谱成像等领域的典型应用进行了述评,讨论了提高复杂样品快速质谱分析选择性的可能方法,并展望了常压直接离子化技术未来发展的可能趋势.  相似文献   

4.
Hu B  Zhang X  Li M  Peng X  Han J  Yang S  Ouyang Y  Chen H 《The Analyst》2011,136(23):4977-4985
Unlike the extractive electrospray ionization (EESI) technique described elsewhere, a corona discharge instead of electrospray ionization has been utilized to charge a neutral solvent spray under ambient conditions for the generation of highly charged microdroplets, which impact a neutral sample plume for the extractive ionization of the analytes in raw samples without any sample pretreatment. Using the positive ion mode, molecular radical cations were easily generated for the detection of non-polar compounds (e.g., benzene, cyclohexane, etc.), while protonated molecular ions of polar compounds (e.g., acetonitrile, acetic ether) were readily produced for the detection. By dispensing the matrix in a relatively large space, this method tolerates highly complex matrices. For a given sample such as lily fragrances, more compounds were detected by the method established here than the EESI technique. An acceptable relative standard deviation (RSD 8.9%, n = 11) was obtained for the direct measurement of explosives (10 ppb) in waste water samples. The experimental data demonstrate that this method could simultaneously detect both polar and non-polar analytes with high sensitivity, showing promising applications for the rapid detection of a wide variety of compounds present in complex matrices.  相似文献   

5.
近年来常压敞开式离子源凭借快速、原位、实时离子化样品等优势,被广泛应用于样品快速筛查、真伪鉴定、质谱成像等领域,已成为当今离子源的研究热点,受到了学术界及仪器制造、化学和生物分析等相关产业界的广泛关注。目前,该类离子源朝着克服基体效应、提高样品表面定位能力及增加离子传输距离等方向发展。本文主要介绍了可以很好解决上述问题并具有代表性的三种常压敞开式离子源:电喷雾萃取离子源(EESI)、介质阻挡放电离子源(DBDI)及空气动力辅助离子源(AFAI),重点涉及原理以及在此基础上所做的设计改进和应用进展。  相似文献   

6.
Ambient mass spectrometry: bringing MS into the “real world”   总被引:1,自引:0,他引:1  
Mass spectrometry has recently undergone a second contemporary revolution with the introduction of a new group of desorption/ionization (DI) techniques known collectively as ambient mass spectrometry. Performed in an open atmosphere directly on samples in their natural environments or matrices, or by using auxiliary surfaces, ambient mass spectrometry (MS) has greatly simplified and increased the speed of MS analysis. Since its debut in 2004 there has been explosive growth in the applications and variants of ambient MS, and a very comprehensive set of techniques based on different desorption and ionization mechanisms is now available. Most types of molecules with a large range of masses and polarities can be ionized with great ease and simplicity with the outstanding combination of the speed, selectivity, and sensitivity of MS detection. This review describes and compares the basis of ionization and the concepts of the most promising ambient MS techniques known to date and illustrates, via typical analytical and bioanalytical applications, how ambient MS is helping to bring MS analysis deeper than ever into the “real world” open atmosphere environment—to wherever MS is needed.  相似文献   

7.
Due to their low polarities and dielectric constants, analytes in solvents such as hexane, chloroform, and ethyl acetate exhibit poor electrospray ionization (ESI) efficiency. These are deemed to be “non-ESI-friendly” solvents. Continuous flow extractive desorption electrospray ionization (CF-EDESI) is a novel ambient ionization technique that was recently developed in our group to manipulate protein charge distributions. Here we demonstrate its potential for ionizing analytes from non-ESI-friendly solvents. This feature makes CF-EDESI attractive to the general analytical community due to its apparent potential in lipidomics, normal phase separations, and hyphenation of mass spectrometry with HPLC-NMR systems. In this context, interest was subsequently initiated to discern mechanistic aspects of CF-EDESI. To achieve this, mechanistic experiments associated with a seemingly similar ambient ionization technique, extractive electrospray ionization (EESI), were emulated to compare CF-EDESI and EESI. Analysis of a series of fatty acids in multiple solvents in the negative ionization mode revealed differences between the two techniques. Whereas EESI has been previously shown to operate via extraction of analytes into the spray solvent, data presented here for CF-EDESI point toward a liquid-liquid mixing process to facilitate ionization. Further, a partial factorial design experiment was performed to evaluate the effects of different experimental variables on signal intensity. Sample flow rate was confirmed to be among the most significant factors to affect sensitivity. As a whole, the work presented provides greater insight into a new ambient ionization process, which exhibits expanded capabilities over conventional ESI; in this case, for direct analysis from non-ESI-friendly solvents.  相似文献   

8.
Dual-spray extractive electrospray ionization (EESI) mass spectrometry as a versatile analytical technique has attracted much interest due to its advantages over conventional electrospray ionization (ESI). The crucial difference between EESI and ESI is that in the EESI process, the analytes are introduced in nebulized form via a neutral spray and ionized by collisions with the charged droplets from an ESI source formed by spraying pure solvent. However, the mechanism of the droplet–droplet interactions in the EESI process is still not well understood. For example, it is unclear which type of droplet–droplet interaction is dominant: bounce, coalescence, disruption, or fragmentation? In this work, droplet–droplet interaction was investigated in detail based on a theoretical model. Phase Doppler anemometry (PDA) was employed to investigate the droplet behavior in the EESI plume and provide the experimental data (droplet size and velocity) necessary for theoretical analysis. Furthermore, numerical simulations were performed to clarify the influence of the sheath gas flow on the EESI process. No coalescence between the droplets in the ESI spray and the droplets in the sample spray was observed using various geometries and sample flow rates. Theoretical analysis, together with the PDA results, suggests that droplet fragmentation may be the dominant type of droplet–droplet interaction in the EESI. The interaction time between the ESI droplet and the sample droplet was estimated to be <5 μs. This work gives a clear picture of droplet–droplet interactions in the dual-spray EESI process and detailed information for the optimization of this method for future applications that require higher sensitivity.  相似文献   

9.
质谱作为一种具有高准确度、高灵敏度、高选择性的检测仪器,在公共安全领域有着重要的应用前景.公共安全领域的需求主要涉及毒品、毒物、爆炸物等化学物质的现场快速检测,因其影响广泛,检测结果需非常准确.作为实验室分析仪器,质谱的准确性和速度能满足公共安全的应用需求,但作为现场快速检测的仪器仍需要一定改进.现场快速检测一方面要求...  相似文献   

10.
We describe a rapid in situ method for detecting agrochemicals on the surface or in the tissue of fruit using a portable mass spectrometer equipped with an ambient ionization source. Two such ionization methods, low temperature plasma (LTP) and paper spray (PS), were employed in experiments performed at a local grocery store. LTP was used to detect diphenylamine (DPA) directly from the skin of apples in the store and those treated after harvest with DPA were recognized by MS and MS/MS. These data therefore allowed ready distinction between organic and non-organic apples. DPA was also found within the internal tissue of purchased apples and its distribution was mapped using LTP. Similarly, thiabendazole residues were detected on the skin of treated oranges in a grocery store experiment in which paper spray was performed by wiping the orange surface with a moist commercial lens wipe and then applying a high voltage to ionize the chemicals directly from the wipe. The handheld mass spectrometer used in these measurements is capable of performing several stages of tandem mass spectrometry (up to MS(5)); the compounds on the fruit were identified by their MS/MS fragmentation patterns. Protonated DPA (m/z 170) produced a characteristic MS(2) fragment ion at m/z 92, while thiabendazole was identified by MS(3) using precursor to fragment ion transitions m/z 202 →m/z 175 →m/z 131. These particular examples exemplify the power of in situ analysis of complex samples using ambient ionization and handheld mass spectrometers.  相似文献   

11.
In this work, a vibrating tip spray ionization source was developed for direct mass spectrometric analysis of raw samples under voltage‐free condition. A solid tip was mounted on a vibrator, and the solid tip was placed on the front of MS inlet. Liquid, viscous, and bulk solid samples could be directly loaded on the tip‐end surface, and then a drop of solvent at microliter level was subsequently loaded on the tip for dissolution and extraction of analytes, and a vibrator was then started to atomize and ionize the analytes under ambient condition. We demonstrated vibrating tip spray mass spectrometry in various applications, including food safety, pharmaceutical analysis, and forensic science. Furthermore, in situ analysis of biological tissues and in vivo analysis of living plants were conveniently performed, due to voltage‐free. Different vibration frequencies and solvent compositions were investigated. The analytical performances, including sensitivity, reproducibility, and linear range, were investigated. The ionization process and mechanism were also discussed in this work.  相似文献   

12.
YQ Huang  JQ You  BF Yuan  YQ Feng 《The Analyst》2012,137(19):4593-4597
A handheld pipette tip column electrospray ionization source (PTC-ESI source) was developed for rapid mass spectrometry analysis at ambient pressure. The PTC-ESI source was made up of three main component parts including a micro DC high voltage (HV) power supply, a micropipette and a disposable micropipette tip filled with a plug of adsorbent. A DC high voltage was applied to the sharp point of the micropipette tip column to induce electrospray ionization. The PTC-ESI source was successfully used for direct analysis of basic organic compounds, organic acids and peptides in a simple matrix. In the case of complex samples, micro-extraction based on the adsorbent phase filled in the pipette tip was used to remove impurities and concentrate target analytes prior to ionization. The eluting solution was not pipetted out, but directly dispersed in the form of electrospray from the pipette tip for ionization. The effectiveness of the PTC-ESI source has been further demonstrated by fast analysis of therapeutic compounds and endogenous bioactive chemicals in complex biological samples.  相似文献   

13.
由于不需要复杂的样品前处理过程,并具有实时、原位分析等特点,常压敞开式离子化技术成为近年来质谱研究的热点之一.实时直接分析(direct analysis in real time,DART)是近年来出现的一种常压敞开式离子化新技术,在食品安全、环境监测、爆炸物检测以及生物医药等诸多研究领域均有广泛的应用.本文简单介绍了常压敞开式离子化方法的发展,DART的基本原理和研究现状.进而介绍了我国质谱研究人员在基于DART的质谱仪器改进、联用技术以及生物药物等检测分析方面取得的新进展和新成果.  相似文献   

14.
质谱技术具有灵敏度高、分析速度快、能提供分子结构信息等特点,在生命科学研究领域扮演着重要角色,常用于组织样品分析。传统地,组织样品分析一般需经过研磨、萃取、分离等繁杂的预处理过程,导致耗时低效,无法满足大量样品高通量分析的实际需求,且不可避免地使组织样品中的一些活性成分损失。近年来,随着新型常压质谱技术的发展,使得组织样品可在无需样品预处理的条件下进行实时、非破坏、在线直接质谱分析,大大提高了分析效率。该文着重介绍了新型直接质谱技术在组织样品分析中的应用,并简要展望了该技术在生命科学、临床医学、食品科学、活体分析等领域的发展趋势。  相似文献   

15.
常压离子化质谱分析技术由于具有无需样品预处理、操作简单、分析效率高等特点,现已在复杂样品的快速分析方面发挥了重要作用。但是,该技术在质谱分析时将样品基质和待测化合物同时进行电离,样品基质对目标化合物的质谱分析造成了严重干扰。为了解决这一问题,在质谱直接分析前先采用固相微萃取技术对复杂样品中的目标化合物进行富集或基质去除,可极大地提高待测化合物的质谱分析灵敏度。该文着重综述了近几年发展起来可直接与常压电离源相联用或可原位电离目标化合物的固相微萃取技术,介绍了它们的原理及在复杂样品分析领域的应用,展望了固相微萃取-直接质谱分析技术的发展趋势。  相似文献   

16.
Extractive electrospray ionization source(EESI)was adapted for ion-ion reaction,which was demonstrated by using a linear quadrupole ion trap mass spectrometer for the first ion-ion reaction of biopolymers in the atmospheric pressure ambient.  相似文献   

17.
丁薛璐  段忆翔 《中国科学:化学》2014,(5):24-25,674,679
近年来,常压开源质谱解吸/离子化(ambient desorption/ionization mass spectrometry)技术的开发促进了质谱分析的蓬勃发展.作为常压开源质谱技术的一大重要分支,基于等离子体的常压质谱解吸/离子化技术因无需样品预处理、无溶剂化过程、高灵敏度、高通量、能实时在线检测样品等优点,受到了学术界及仪器制造、化学和生物分析等相关产业界的广泛关注.本文从离子源的种类、原理及应用等角度对目前我国在开源质谱领域中自主研发的基于等离子体的常压离子源的研究进展进行了总结,并对此类等离子体常压离子源的发展进行了展望,重点涉及微波等离子体源、常压微辉光放电等离子体源和解吸电晕束离子源.  相似文献   

18.
Forensic applications of ambient ionization mass spectrometry   总被引:1,自引:0,他引:1  
This review highlights and critically assesses forensic applications in the developing field of ambient ionization mass spectrometry. Ambient ionization methods permit the ionization of samples outside the mass spectrometer in the ordinary atmosphere, with minimal sample preparation. Several ambient ionization methods have been created since 2004 and they utilize different mechanisms to create ions for mass-spectrometric analysis. Forensic applications of these techniques—to the analysis of toxic industrial compounds, chemical warfare agents, illicit drugs and formulations, explosives, foodstuff, inks, fingerprints, and skin—are reviewed. The minimal sample pretreatment needed is illustrated with examples of analysis from complex matrices (e.g., food) on various substrates (e.g., paper). The low limits of detection achieved by most of the ambient ionization methods for compounds of forensic interest readily offer qualitative confirmation of chemical identity; in some cases quantitative data are also available. The forensic applications of ambient ionization methods are a growing research field and there are still many types of applications which remain to be explored, particularly those involving on-site analysis. Aspects of ambient ionization currently undergoing rapid development include molecular imaging and increased detection specificity through simultaneous chemical reaction and ionization by addition of appropriate chemical reagents.  相似文献   

19.
In this study, we investigated how binary mixtures of compounds influence each other's signal intensity in electrospray ionization (ESI), extractive electrospray ionization (EESI) and secondary electrospray ionization (SESI) experiments. The experiments were conducted using a series of homologous primary amines (from 1-butyl to 1- decylamine). In every experiment, two of the amines were present, and all 21 possible combinations were measured with EESI, ESI and SESI as ionization sources. Except for the volatility, which decreases with increasing molecular weight, the physico-chemical properties of the amines are very similar, so that the intensity ratio obtained in each experiment provides information about discrimination effects occurring during the ionization process. The results show that for the relatively volatile compounds investigated, the EESI ionization mechanism resembles the SESI-like gas-phase charge transfer more than ESI-like analyte ionization in solution. In addition, almost no discrimination effects were observed in the spectra obtained in EESI experiments. Quantitative EESI experiments with nonylamine as internal standard showed that EESI is capable of providing both more accurate and more precise results than SESI and ESI.  相似文献   

20.
Direct mass spectrometry (MS) analysis of biofluids with simple procedures represents a key step in the translation of MS techniques to clinical and point‐of‐care applications. The current study reports the development of a single‐step method using slug‐flow microextraction and nano‐electrospray ionization for MS analysis of organic compounds in blood and urine. High sensitivity and quantitation precision have been achieved in the analysis of therapeutic and illicit drugs in 5 μL samples. Real‐time chemical derivatization has been incorporated for analyzing anabolic steroids. The monitoring of enzymatic functions has also been demonstrated with cholinesterase in wet blood. The reported study encourages the future development of disposable cartridges, which function with simple operation to replace the traditional complex laboratory procedures for MS analysis of biological samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号