首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 12 毫秒
1.
合成了甲福明的分子印迹聚合物,以此聚合物为识别物质,在线分离富集甲福明,建立了一种测定甲福明的流动式化学发光但感器。N-溴代丁二酰亚胺(NBS)和荧光素与甲福明发生化学反应,产生强的化学发光。甲福明质量浓度在2×10-8~8×10-6g/mL范围内同发光强度成良好线性关系,方法的检出限为6×10-9g/mL,相对标准偏差小于5%(n=9)。选择性实验表明将分子印迹聚合物作为识别物质应用于化学发光分析中,能大大提高化学发光分析方法的选择性。该传感器可逆性强、稳定性好,可重复使用100次以上,已用于人体尿样中甲福明的测定。  相似文献   

2.
In this paper, a novel flow chemiluminescence (CL) clenbuterol sensor based on molecularly imprinted polymer (MIP) on line enrichment nanogram clenbuterol and chemiluminescence reaction of potassium permanganate and formaldehyde in the polyphosphate enhanced by clenbuterol. Clenbuterol in the urine was selectively adsorbed on the clenbuterol-imprinted polymer, which was packed into the flow cell. The formaldehyde and the polyphosphate with potassium permanganate flowed through the flow cell and reacted with the on line adsorbed clenbuterol and produced strong CL. The results show that the sensor was reversible. The CL intensity was linear with clenbuterol concentration from 1.0 × 10−9 g/mL to 5.0 × 10−8 g/mL. The detection limit was 3.0 × 10−10 g/mL. The R.S.D. for ng/mL clenbuterol was less than 5% (n = 3). The present method offered a high selectivity and sensitivity that made the quantitative analysis of trace clenbuterol (ng/mL) in the animal urine sample.  相似文献   

3.
监测环境、食物中的有机磷残留是一项非常重要的工作。目前,一般采测量,但是设备昂贵、色谱预处理复杂,用色谱法难以快速测量有机磷农药。分子印迹技术(molecular imprinting technique,MIT)是Wulf[f2-4]等发展起来的一项为获得空间结构和结合位点上与某一结构的化合物或化合反  相似文献   

4.
A novel potentiometric sensor based on molecularly imprinted polymer (MIP) for propranolol, an adrenergic-blocking drug, was designed. The influence of molecularly imprinted polymer particle content and sodium tetraphenylborate additives in polyvinylchloride membrane was shown. The electrodes show near-Nernstian responses down to 10?4–10?5?M propranolol concentration. The potentiometric response of MIP-based sensor for propranolol in mixed nonaqueous medium was shown at first. Sensor selectivity relative to various inorganic cations, atenolol and metoprolol, was reported. Direct potentiometry was used to determine propranolol in aqueous modeling solutions and pharmaceutical preparations with good results.  相似文献   

5.
氯丙嗪分子印迹化学发光微流控传感器芯片的研究   总被引:5,自引:0,他引:5  
以氯丙嗪分子印迹聚合物为识别物质,以鲁米诺-K3Fe(CN)6化学发光体系,建立了一种新型的氯丙嗪化学发光微流控分子印迹传感器芯片的检测方法。利用二氧化碳激光在聚甲基丙烯酸甲酯材质上刻蚀出200μm宽,150μm深的微通道,8 mm长,1 mm宽,0.5 mm深的微检测池。微检测池中填充50μm粒径大小的热聚合得到的氯丙嗪分子印迹聚合物作为识别物质,在线富集氯丙嗪,富集的氯丙嗪可以增强鲁米诺和K3Fe(CN)6的化学发光强度,以化学发光强度定量氯丙嗪量。该传感器的响应值与0.02~0.4μg/mL氯丙嗪呈良好的线性关系,检出限为8 ng/mL(3σ)。该微流控传感器芯片已用于测定人尿液中的氯丙嗪。  相似文献   

6.
He D  Zhang Z  Zhou H  Huang Y 《Talanta》2006,69(5):1215-1220
Based on a molecularly imprinted polymer (MIP) as the recognition element, a novel chemiluminescence (CL) micro flow sensor on a chip for the determination of terbutaline in human serum is described. The MIP was prepared by using terbutaline as the template, methacrylic acid (MAA) as the functional monomer, ethylene glycol dimethacrylate (EGDMA) as the cross-linking monomer, and acetonitrile as the solvent. The chip was fabricated from two 50 mm × 40 mm × 5 mm transparent poly (methylmethacrylate) (PMMA) slices. The microchannels on the chip etched by CO2 laser were 200 μm wide and 150 μm deep. The microsensor cell filled with 2 mg MIP for selectively on line adsorbing terbutaline was 10 mm long, 1 mm wide, and 0.5 mm deep. All reagents were controlled by the syringe pump with an accurate timer. The on line adsorbed terbutaline by the MIP can enhance the CL intensity of the reaction of luminol with ferricyanide. The enhanced CL intensity is linear with terbutaline concentration from 8.0 to 100 ng/mL with a detection limit of 4.0 ng/mL (3σ). The micro flow sensor provides for good reproducibility with the relative standard deviation of 3.6% (n = 7) for 20 ng/mL terbutaline.  相似文献   

7.
Wu B  Wang Z  Xue Z  Zhou X  Du J  Liu X  Lu X 《The Analyst》2012,137(16):3644-3652
Based on Ru(bpy)(3)(2+)-Au nanoparticles decorated multi-walled carbon nanotubes composites and a molecularly imprinted polymer (MIP), we propose a novel molecularly imprinted electrochemiluminescence (ECL) sensor to selectively determine isoniazid (INH). The MIP is synthesized through electrochemical copolymerization of acrylamide and N,N'-methylene diacrylamide in the presence of INH template molecules. The enhanced ECL intensity is linear in the range of 0.1 to 110 μg cm(-3) and the detection limit is 0.08 μg cm(-3) (3σ) INH with relative standard deviation 3.8% (n = 6) for 8 μg cm(-3). As a result, the sensor has been successfully applied to the determination of INH in human urine and pharmaceutical samples. Moreover, the possible ECL mechanism is discussed.  相似文献   

8.
9.
A novel molecularly imprinted polymer (MIP) coated bulk acoustic wave (BAW) sensor was fabricated for liquid phases. It can be used as a sensitive portable implement for the assay of 2,4-dichlorophenoxyacetic acid. A logarithmic response relationship between 2.0 × 10–7 M and 5.0 × 10–4 M was found. The detection limit was 1.0 × 10–7 M. Recoveries were 93.2–108.7%. Influencing factors were investigated in detail and optimized.  相似文献   

10.
Dicloran pesticide is used to inhibit the fungal spore germination for different crops. Because of the increasing application of pesticides, reliable and accurate analytical methods are necessary. The aim of this work is designing the highly selective sensor to determine the dicloran in biological and environmental samples. Multi-walls carbon nanotubes and a molecularly imprinted polymer (MIP) were used as modifiers in the sensor composition. A dicloran MIP and a nonimprinted polymer (NIP) were synthesized and applied in the carbon paste electrode. After the optimization of electrode composition, it was used to determine the concentration of analyte. Parameters affecting the sensor response were optimized, such as sample pH, electrolyte concentration and its pH, and the instrumental parameters of square wave voltammetry. The MIP-CP electrode showed very high recognition ability in comparison with NIP-CP. The obtained linear range was 1 × 10?6 to 1 × 10?9 mol L?1. The detection limit was 4.8 × 10?10 mol L?1. This sensor was used to determine the dicloran in real samples (human urine, tap and river water samples) without special sample preparation before analysis. All important parameters were optimized, improving the sensor response considerably.  相似文献   

11.
A novel molecularly imprinted polymer (MIP) coated bulk acoustic wave (BAW) sensor was fabricated for liquid phases. It can be used as a sensitive portable implement for the assay of 2,4-dichlorophenoxyacetic acid. A logarithmic response relationship between 2.0 x 10(-7) M and 5.0 x 10(-4)M was found. The detection limit was 1.0 x 10(-7) M. Recoveries were 93.2-108.7%. Influencing factors were investigated in detail and optimized.  相似文献   

12.
A piezoelectric quartz sensor coated with molecularly imprinted polymer (MIP) for caffeine was developed. The MIP was prepared by co-polymerizing methacrylic acid (MAA) and ethylene glycol dimethacrylate (EDMA) in the presence of azobis(isobutyronitrile) as initiator, caffeine as template molecule, and chloroform as solvent. The MIP suspension in polyvinyl chloride/tetrahydrofuran (6:2:1 w/w/v) solution was spin coated onto the surface of the electrode of a 10 MHz AT-cut quartz crystal. The sensor exhibited a linear relationship between the frequency shift and caffeine concentration in the range of 1×10–7 mg mL–1 up to 1x10–3 mg mL–1 [correlation coefficient (r)=0.9935] in a stopped flow measurement mode. It has a sensitivity of about 24 Hz/ln(concentration, mg mL–1). A steady-state response was achieved in less than 10 min. The performance characteristic of the sensor shows a promising and inexpensive alternative method of detecting caffeine. Surface studies were carried out for the reagent phase of the sensor using SEM, AFM, and XPS analysis in order to elucidate the imprinting of the caffeine molecule. The SEM micrograph, AFM image, and XPS spectra confirmed the removal of caffeine by Soxhlet extraction in the imprinting process and the rebinding of caffeine to the MIP sensing layer during measurement.  相似文献   

13.
X Zheng  Z Guo  Z Zhang 《Analytical sciences》2001,17(9):1095-1099
Based on a new electrogenerated chemiluminescence (ECL) analytical idea, this paper explains a sensitive and selective flow-injection ECL method using luminol for the determination of isoniazid, based on the sensitizing effect of isoniazid for the weak ECL emission of electrochemically oxidized luminol. Under the optimum experimental conditions, the relative ECL intensity was linear with isoniazid concentration in the range of 4.0 x 10(-8) mol/L to 8.0 x 10(-6) mol/L and with a detecting limit of 2.8 x 10(-8) mol/L.  相似文献   

14.
This paper reports the synthesis and testing of a molecularly imprinted polymer membrane for digoxin analysis. Digoxin-specific bulk polymer was obtained by the UV initiated co-polymerisation of methacrylic acid and ethylene glycol dimethacrylate in acetonitrile as porogen. After extracting the template analyte, the ground polymer particles were mixed with plasticizer polyvinyl chloride to form a MIP membrane. A reference polymer membrane was prepared from the same mixture of monomers but with no template. The resultant membrane morphologies were examined by scanning electron microscopy. The imprinted membrane was tested as the recognition element in a digoxin-sensitive fluorescence sensor; sensor response was measured using standard solutions of digoxin at concentrations of up to 4 × 10−3 mg L−1. The detection limit was 3.17 × 10−5 mg L−1. Within- and between-day relative standard deviations RSD (n = 5) were in the range 4.5-5.5% and 5.5-6.5% respectively for 0 and 1 × 10−3 mg L−1 digoxin concentrations. A selectivity study showed that compounds of similar structure to digoxin did not significantly interfere with detection for interferent concentrations at 10, 30 and 100 times higher than the digoxin concentration. This simply manufactured MIP membrane showed good recognition characteristics, a high affinity for digoxin, and provided satisfactory results in analyses of this analyte in human serum.  相似文献   

15.
A piezoelectric quartz crystal (PQC) sensor based on a molecularly imprinted polymer (MIP) has been developed for enantioselective and quantitative analysis of d-(+)-methamphetamine (d(+)-MA). The sensor was produced by bulk polymerization and the resulting MIP was then coated on the gold electrode of an AT-cut quartz crystal. Conditions such as volume of polymer coating, curing time, type of PQC, baseline solvent, pH, and buffer type were found to affect the sensor response and were therefore optimized. The PQC-MIP gave a stable response to different concentrations of d(+)-MA standard solutions (response time = 10 to 100 s) with good repeatability (RSD = 0.03 to 3.09%; n = 3), good reproducibility (RSD = 3.55%; n = 5), and good reversibility (RSD = 0.36%; n = 3). The linear range of the sensor covered five orders of magnitude of analyte concentration, ranging from 10−5 to 10−1 μg mL−1, and the limit of detection was calculated as 11.9 pg d(+)-MA mL−1 . The sensor had a highly enantioselective response to d(+)-MA compared with its response to l(−)-MA, racemic MA, and phentermine. The developed sensor was validated by applying it to human urine samples from drug-free individuals spiked with standard d(+)-MA and from a confirmed MA user. Use of the standard addition method (SAM) and samples spiked with d(+)-MA at levels ranging from 1 × 10−3 to 1 × 10−2 μg mL−1 showed recovery was good (95.3 to 110.9%).  相似文献   

16.
以丙烯酰胺为功能单体,葛根素为模板分子,马来松香丙烯酸乙二醇酯为交联剂,采用循环伏安法合成了葛根素分子印迹膜,并以此为识别元件制备了葛根素电化学传感器。该传感器对葛根素具有高度的选择性和良好的敏感度,葛根素氧化峰电流与其浓度在6.0×10-8~1.6×10-3mol/L范围内呈良好的线性关系,检出限为2.0×10-8mol/L。将此传感器用于葛根素注射液和木瓜葛根片中葛根素的含量测定,回收率为97.7%~106.4%。  相似文献   

17.
D Zang  M Yan  P Zhao  L Ge  S Liu  J Yu 《The Analyst》2012,137(18):4247-4253
Novel fenvalerate double-sided hollow molecularly imprinted microspheres (fenvalerate-DHMIMs) were fabricated by in situ polymerization with the help of mesoporous silica microspheres (MSMs) in this paper for the very first time. Scanning electron microscope was employed to characterize the surface morphology of the fenvalerate-DHMIMs. Taking advantage of the quenching effect of fenvalerate on the luminol-H(2)O(2)-NaOH chemiluminescence system, a new model was established to determine fenvalerate by a highly selective flow injection chemiluminescence method. The traditional flow-through cell was replaced by a novel Y-shaped column. The chemiluminescence intensity was linear with fenvalerate concentration over the range of 5.0 × 10(-8) to 2.0 × 10(-5) g mL(-1) and the detection limit was 2.2 × 10(-8) g mL(-1). The relative standard deviation (RSD) for the determination of 2.0 × 10(-6) g mL(-1) fenvalerate was 1.4% (n = 11). The proposed method was applied to the determination of fenvalerate in real samples with satisfactory results.  相似文献   

18.
19.
Wang Z  Li H  Chen J  Xue Z  Wu B  Lu X 《Talanta》2011,85(3):1672-1679
A novel electrochemical sensor based on molecularly imprinted polymer film has been developed for aspirin detection. The sensitive film was prepared by co-polymerization of p-aminothiophenol (p-ATP) and HAuCl(4) on the Au electrode surface. First, p-ATP was self-assembled on the Au electrode surface by the formation of Au-S bonds. Then, the acetylsalicylic acid (ASA) template was assembled onto the monolayer of p-ATP through the hydrogen-bonding interaction between amino group (p-ATP) and oxygen (ASA). Finally, a conductive hybrid membrane was fabricated at the surface of Au electrode by the co-polymerization in the mixing solution containing additional p-ATP, HAuCl(4) and ASA template. Meanwhile, the ASA was spontaneously imprinted into the poly-aminothiophenol gold nanoparticles (PATP-AuNPs) complex film. The amount of imprinted sites at the PATP-AuNPs film significantly increases due to the additional replenishment of ASA templates. With the significant increasing of imprinted sites and doped gold nanoparticles, the sensitivity of the molecular imprinted polymer (MIP) electrode gradually increased. The molecularly imprinted sensor was characterized by electrochemical impedance spectroscopy (EIS), differential pulse voltammetry (DPV), and cyclic voltammetry (CV). The linear relationships between current and logarithmic concentration were obtained in the range from 1 nmol L(-1) to 0.1 μmol L(-1) and 0.7 μmol L(-1) to 0.1 mmol L(-1). The detection limit of 0.3 nmol L(-1) was achieved. This molecularly imprinted sensor for the determination of ASA has high sensitivity, good selectivity and reproducibility, with the testing in some biological fluids also has good selectivity and recovery.  相似文献   

20.
A morphine-sensitive device was constructed based on a molecularly imprinted polymer. The imprinted polymer exhibited recognition properties previously. A method of detection based on competitive binding was used to measure morphine in the concentration range 0.1–10 μg/ml. A morphine concentration of 0.5 μg/ml gave a peak current (by oxidation) of 4 nA. The method of morphine detection involves two steps. In the first step, morphine binds selectively to the molecularly imprinted polymer in the sensor. In the second step, an electroinactive competitor (codeine) is added in excess, whence some of the bound morphine is released. The released morphine is detected by an amperometric method. The advantages of this type of sensor compared to biosensors based on antibodies, enzymes or cells are discussed. This sensor, based on an artificial recognition system, demonstrates autoclave compatibility, long-time stability and resistance to harsh chemical environments.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号