首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The aim of this article is to provide an overview on the potential of the CE–herbicides binomial. To this end, the methods proposed so far are discussed: their characteristics, types of samples and analytes to which the methods have been applied, sample preparation steps, if required (e.g. cleanup–preconcentration, derivatization steps), and type of detection in each case. Also, the methods are compared with counterparts based on LC, when appropriate. The role of MS detection in present and future analytical research in this field (both for identification and quantitation) are commented. The foreseeable and desirable trends in analysis of herbicides are also outlined in the light of the present trends in metabolomics as a way of knowing the pathways, the intermediate and final degradation products that can influence the crops and the food chain of humans and other animals, as a result.  相似文献   

2.
This paper is a comprehensive review article on capillary electrophoresis (CE) in clinical and forensic analysis. It is based upon the literature of 1997 and 1998, presents CE examples in major fields of application, and provides an overview of the key achievements encountered, including those associated with the analysis of drugs, serum proteins, hemoglobin variants, and nucleic acids. For CE in clinical and forensic analysis, the past two years witnessed a breakthrough to routine applications. As most coauthors of this review are associated with diagnostic or forensic laboratories now using CE on a routine basis, this review also contains data from routine applications in drug, protein, and DNA analysis. With the first-hand experience of providing analytical service under stringent quality control conditions, aspects of quality assurance, assay specifications for clinical and forensic CE and the pros and cons of this maturing, cost-and pollution-controlled age technology are also discussed.  相似文献   

3.
A CE method has been developed for the analysis of wasp venoms and pollen extracts of Phleum pratense and Betula verrucosa. Various electrolyte systems can be used but the best separation and reproducibility are attained in 0.15 mol/l phosphoric acid, pH 1.8. UV photometric detection at 190 nm is sufficiently sensitive for determination of the polypeptides and glycoproteins contained in these materials (the detection limit for phospholipase A2 is 0.4 ng). The allergens from wasp venoms and pollen extracts yield characteristic electropherograms which can be used for control of the allergen production. Modification of capillary wall with poly(ethylhydroxy methacrylate) causes a decrease in the migration times and the separation efficiency is retained.  相似文献   

4.
The history and present status of capillary electrophoresis in China are critically reviewed. Features of major research and future prospects are described.  相似文献   

5.
The most important applications of magnetic resonance imaging in catalysis and related areas are considered. In combination with other advanced instrumental methods, this technique can provide essential information about the properties of catalysts and reactors and about processes occurring there. The examples given in the report include the preparation and characterization of porous supports; loading of supports with an active component by impregnation; and investigation of the structure of a granular catalyst bed, various mass transfer processes, and the operation dynamics of a model reactor.  相似文献   

6.
7.
8.
9.
10.
11.
It has been already three decades, since the fluorescent nanocrystals called quantum dots (QDs) appeared and attracted attention of a broad scientific community. Their excellent not only optical but also electronic properties predetermined QDs for utilization in a variety of areas. Besides lasers, solar cells, and/or computers, QDs have established themselves in the field of (bio)chemical labeling as well as medical imaging. However, due to the numerous application possibilities of QDs, there are high demands on their properties that need to be precisely controlled and characterized. CE with its versatile modes and possibilities of detection was found to be an effective tool not only for characterization of QDs size and/or surface properties but also for monitoring of their interactions with other molecules of interest. In this minireview, we are giving short insight in analysis of QDs by CE, and summarizing the advantages of this method for QDs characterization.  相似文献   

12.
The current status and likely future directions of complexes of V(V/IV), Cr(III), Mo(VI), W(VI), Zn(II), Cu(II), and Mn(III) as potential oral drugs against type 2 diabetes are reviewed. We propose a unified model of extra- and intracellular mechanisms of anti-diabetic efficacies of V(V/IV), Mo(VI), W(VI), and Cr(III), centred on high-oxidation-state oxido/peroxido species that inhibit protein tyrosine phosphatases (PTPs) involved in insulin signalling. The postulated oxidative mechanism of anti-diabetic activity of Cr(III) via carcinogenic Cr(VI/V) (which adds to safety concerns) is consistent with recent clinical trials on Cr(III) picolinate, where activity was apparent only in patients with poorly controlled diabetes (high oxidative stress), and the correlation between the anti-diabetic activities and ease of oxidation of Cr(III) supplements and their metabolites in vivo. Zn(II) and Cu(II) anti-diabetics act via different mechanisms and are unlikely to be used as specific anti-diabetics due to their diverse and unpredictable biological activities. Hence, future research directions are likely to centre on enhancing the bioavailability and selectivity of V(V/IV), Mo(VI), or W(VI) drugs. The strategy of potentiating circulating insulin with metal ions has distinct therapeutic advantages over interventions that stimulate the release of more insulin, or use insulin mimetics, because of many adverse side-effects of increased levels of insulin, including increased risks of cancer and cardiovascular diseases.  相似文献   

13.
14.
In the 1980s, capillary electrophoresis (CE) developed rapidly into a first-class analytical separation technique. Its advances in instrumentation and method development will not only enhance or complement existing mature separation techniques such as liquid chromatography and conventional slab gel electrophoresis, but will also severely challenge these separation methods. A brief overview of the most striking achievements of CE in the 1980s is given. which illustrates the challenges to liquid chromatography and conventional slab gel electrophoresis, and some detailed discussions are presented to highlight the advantages of CE. New developments in CE that can be expected for the 1990s include especially column technology, separation chemistry and instrumentation, which will serve further to diversify and improve the applicability of this technique in areas which are poorly addressed by other separation methods. This paper considers and speculates on the technological advancements that can be expected to emerge for CE in the 1990s.  相似文献   

15.
Cells, basic units of living structures and functions, build up a complicated small world, and their order and complexity resemble a small universe. The detailed understanding and elucidation of the matter transport and energy conversion mechanisms within a single cell will expand our knowledge about the origin and evolution of life, the disease mechanisms and much more. In past decades, single-cell analysis has been rapidly and significantly improved and various methodologies have been developed to reveal the complexity of mass, energy, and information within single cells. In this review, we focused on the methods developed in recent years for single-cell analysis, including electrochemical method, optical method, and mass spectrometry method. We reviewed the recent advances and representative studies in this research field, and also discussed the strengths and limitations of each method. Finally, we presented the existing technical challenges and further directions for single-cell analysis.  相似文献   

16.
Porras SP  Kenndler E 《Electrophoresis》2005,26(17):3279-3291
N,N-Dimethylformamide (DMF) is a dipolar protophilic solvent with physicochemical properties that makes it suitable as solvent for capillary electrophoresis (CE). It is prerequisite for the proper application of CE to adjust and to change the pH of the background electrolyte (BGE) in a defined manner. This was done in the present work using benzoic acid-benzoate by selecting different concentration ratios of acid and salt, and calculating the theoretical pH from the activity-corrected Henderson-Hasselbalch equation. The mobilities of the analytes (chloro- and nitro-substituted phenolates) were found to follow reasonably well the typical sigmoid mobility versus pH curve as predicted by theory. The actual mobilities and pK(a) values (at 25 degrees C) of the analytes were derived from these curves. pK(a) values were in the range of 11.1-11.7, being thus 3-4.4 units higher than in water. This pK(a) shift is caused by the destabilization of the analyte anion and the better stability (solubility) of the molecular analyte acid in DMF, which overcome the higher basicity of DMF compared to water. Absolute mobilities were calculated from the actual mobilities; they were between 32x10(-9) and 42x10(-9) m(2)/Vxs. Slight deviations of the measured mobilities from the theoretical mobility versus pH curve were discussed on the bases of ion pairing and heteroconjugation and homoconjugation of either buffer components or buffer components and analytes. Heteroconjugation was used as a mechanism for the electrically driven separation of neutral analyte molecules in a BGE where salicylate acted as complex forming ion. Rough estimation of the complexation constants for the phenolic analytes gave values in the range of 100-200 L/mol. Addition of water to the solvent decreased the effect of heteroconjugation, but it was still present up to the surprisingly high concentration of 20% water. Electrophoretically relevant parameters like ionic mobilities and pK(a) values, and conjugation and ion pairing are dependent on the water content of the solvent. The water uptake of DMF was measured when exposed to humidity of ambient air. The resulted behavior of the water uptake was found rather similar to that for acetonitrile and methanol.  相似文献   

17.
Phillies GD 《Electrophoresis》2012,33(6):1008-1012
Capillary electrophoresis with a polymer solution support medium is a well-established powerful analytical tool. This paper discusses a possible alternative application of capillary electrophoresis, namely a path for studying the dynamics of polymer solutions. The key to the approach is an inversion of perspective. Instead of treating the migrating species as the object of experimental importance and the support medium as being of importance only because it facilitates separations, one treats the polymer solution as being of experimental importance, and the choice of migrating species as being of interest only because different species may probe different aspects of polymer dynamics.  相似文献   

18.
Over the past 15 years, CE as an analytical tool has shown great promise in replacing many conventional clinical laboratory methods, such as electrophoresis and HPLC. CE's appeal was that it was fast, used very small amounts of sample and reagents, was extremely versatile, and was able to separate large and small analytes, whether neutral or charged. Because of this versatility, numerous methods have been developed for analytes that are of clinical interest. Other than molecular diagnostic and forensic laboratories CE has not been able to make a major impact in the United States. In contrast, in Europe and Japan an increasing number of clinical laboratories are using CE. Now that automated multicapillary instruments are commercially available along with cost-effective test kits, CE may yet be accepted as an instrument that will be routinely used in the clinical laboratories. This review will focus on areas where CE has the potential to have the greatest impact on the clinical laboratory. These include analyses of proteins found in serum and urine, hemoglobin (A1c and variants), carbohydrate-deficient transferrin, forensic and therapeutic drug screening, and molecular diagnostics.  相似文献   

19.
Research to the racemization reaction of L-amino acids is performed through a laboratory-made 16-channel capillary array electrophoresis. The impact factors such as catalyst, solvent, and reactive time which influenced the racemization reaction are screened, the experimental results proved that the capillary array electrophoresis is qualified as combinatorial enantiomeric screening system.  相似文献   

20.
Timerbaev AR 《Electrophoresis》2004,25(23-24):4008-4031
This review as a sequel of three earlier similar reports gives a summary of the progress and significant methodological developments, starting from 2002, in the use of capillary electrophoresis (CE) for inorganic ion analysis. As substantiated by the illustrative number of relevant references, improvements in sensitivity achieved both in and outside a CE system, advances in manipulating the separation selectivity, novel hardware configurations, and system performance innovations are continually being reported over the review period. Specifically viewed are the recent advancements in elemental (bio)speciation analysis, which remains one of the most fertile areas of CE research, as well as in three recently booming research topics: contactless conductivity detection, separations on microchips, and transient isotachophoretic preconcentration. A state-of-the-art picture of technique's potentialities within the field of interest presented here demonstrates that CE has become recognized and is growing in acceptance as a reliable alternative to traditional analytical methods such as high-performance liquid chromatography (HPLC).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号