首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A voltammetric determination of adriamycin (ADM) at a carbon paste electrode (CPE) in the presence of cetyltrimethylammonium bromide (CTAB) is described. ADM strongly adsorbs on the surface of the electrode by the adsorption of CTAB, thereby affecting the reduction current. This method provides a detection limit below 10(-10) mol/L for ADM. The experimental parameters, which influence the voltammetric responses of ADM, e.g. the pH value, variety and concentration of surfactants and the scan rate, were optimized. The reduction peak current changes linearly with the ADM concentration over the range from 2.5 x 10(-8) mol/L to 5 x 10(-6) mol/L. The detection limit is 4 x 10(-10) mol/L for an accumulation time of 3 min. The coefficient of variation, determined at 4 x 10(-6) mol/L ADM, is 3.0% (n = 8). Using this method, ADM in the patient's urine samples, which undergoes active ADM chemotherapy, was determined.  相似文献   

2.
铁(Ⅱ)能在具有催化活性的纳米TiO2表面产生化学发光辐射,表面活性剂十六烷基三甲基溴化铵(CTAB)的存在能显著增敏此发光强度。此外,纳米氧化钛也能增强Fenton反应的化学发光强度,据此,建立了纳米TiO2-CTAB-Fenton化学发光新体系检测铁(Ⅱ)的新方法。在优化条件下,亚铁离子在1.0×10-8~1.0×10-6mol/L浓度范围内与其化学发光强度呈现良好的线性关系,对1.0×10-7mol/L浓度的亚铁离子平行测定5次,相对标准偏差为3.9%,检出限为4.0×10-9mol/L。文中还对化学发光反应机理进行了初步探讨。  相似文献   

3.
The electrochemical behaviors of adrenaline at the acetylene black electrode in the presence of sodium dodecyl sulfate (SDS) were investigated by cyclic voltammetry and electrochemical impedance spectroscopy (EIS). The results indicated that the electrochemical responses of adrenaline were apparently improved by SDS, due to the enhanced accumulation of protonated adrenaline via electrostatic interaction with negatively charged SDS at the hydrophobic electrode surface. This was verified by the influences of different kinds of surfactants on the electrochemical signals of adrenaline. The electrochemical parameters of the adrenaline oxidation were explored by chronocoulometry. Under optimal working conditions, the oxidation peak current at 0.57 V was proportional to adrenaline concentration in the range of 5.0x10(-8) to 7.0x10(-6) mol/L, with a low detection limit of 1.0x10(-8)mol/L for 70s accumulation by differential pulse voltammetry (DPV). This method was applied to determine adrenaline in the hydrochloride injection sample. The results are satisfying compared with that by the standardized method of high performance liquid chromatography (HPLC).  相似文献   

4.
A simple and highly selective electrochemical method was developed for the simultaneous determination of aspartame and cyclamate in dietary products at a boron-doped diamond (BDD) electrode. In square-wave voltammetric (SWV) measurements, the BDD electrode was able to separate the oxidation peak potentials of aspartame and cyclamate present in binary mixtures by about 400 mV. The detection limit for aspartame in the presence of 3.0x10(-4) mol L(-1) cyclamate was 4.7x10(-7) mol L(-1), and the detection limit for cyclamate in the presence of 1.0x10(-4) mol L(-1) aspartame was 4.2x10(-6) mol L(-1). When simultaneously changing the concentration of both aspartame and cyclamate in a 0.5 mol L(-1) sulfuric acid solution, the corresponding detection limits were 3.5x10(-7) and 4.5x10(-6) mol L(-1), respectively. The relative standard deviation (R.S.D.) obtained was 1.3% for the 1.0x10(-4) mol L(-1) aspartame solution (n=5) and 1.1% for the 3.0x10(-3) mol L(-1) cyclamate solution. The proposed method was successfully applied in the determination of aspartame in several dietary products with results similar to those obtained using an HPLC method at 95% confidence level.  相似文献   

5.
Ellagic acid (C(14)H(6)O(8)), a naturally occurring phytochemical, found mainly in berries and some nuts, has anticarcinogenic and antioxidant properties. It is found that fluorescence of Ellagic acid (EA) is greatly enhanced by micelle of cetyltrimethylammonium bromide (CTAB) surfactant. Based on this effect, a sensitive proposed fluorimetric method was applied for the determination of Ellagic acid in aqueous solution. In the Borax-HCl buffer, the fluorescence intensity of Ellagic acid in the presence of CTAB is proportional to the concentration of Ellagic acid in range from 8.0×10(-10) to 4.0×10(-5) mol L(-1); and the detection limits are 3.2×10(-10) mol L(-1) and 5.9×10(-10) mol L(-1) excited at 266 nm and 388 nm, respectively. The actual samples of pomegranate rinds are simply manipulated and satisfactorily determined. The interaction mechanism studies argue that the negative EA-Borax complex is formed and solubilized in the cationic surfactant CTAB micelle in this system. The fluorescence intensity of EA enhances because the CTAB micelle provides a hydrophobic microenvironment for EA-Borax complex, which can prevent collision with water molecules and decrease the energy loss of EA-Borax complex.  相似文献   

6.
郑妍鹏  莫金垣  谢天尧 《色谱》2002,20(2):159-162
 采用柠檬酸 柠檬酸钠作为缓冲体系 ,使用负高压 ,对Cl-,NO3 -,HCO3 -和H2 PO4 -等 4种常见阴离子进行了分离检测 ,研究了缓冲剂的种类、浓度、pH值及操作电压对分离的影响。在选定的条件下 ,4种离子的定量线性范围 :Cl-5 0× 10 -5mol/L~ 2 5× 10 -3 mol/L ,NO3 -6 0× 10 -5mol/L~ 2 0× 10 -3 mol/L ,HCO3 -5 0× 10 -6mol/L~ 2 0× 10 -4 mol/L ,H2 PO4 -6 0× 10 -5mol/L~ 1 0× 10 -3 mol/L ;检出限 :Cl-1 5× 10 -5mol/L ,NO3 -3 0×10 -5mol/L ,HCO3 -1 0× 10 -6mol/L ,H2 PO4 -2 0× 10 -5mol/L ;峰面积的RSD (n =6 ) :Cl-3 1% ,  相似文献   

7.
采用水热法合成了纳米氧化锌-氧化石墨烯复合材料,并基于该复合材料构制了一种新型双酚A传感器,研究了该传感器的电化学行为。结果表明,在含8.0×10-5mol/L CTAB的p H 7.0磷酸盐缓冲液中,双酚A在0.573V处出现1个不可逆的氧化峰,具有良好的电化学响应;其氧化峰电流与浓度在1.0×10-8~4.0×10-5mol/L范围内呈良好的线性关系,检出限为5.0×10-9mol/L;对模拟环境水样中双酚A进行3次平行测定的回收率在96.3%~101.9%之间,相对误差在1.2%~3.8%范围内。该传感器具有灵敏度高、线性范围宽的特点。  相似文献   

8.
C Fan  H Wang  D Zhu  G Wagner  G Li 《Analytical sciences》2001,17(2):273-276
Horseradish peroxidase was incorporated in a kieselguhr membrane. The electron-transfer process of the enzyme was examined by cyclic voltammetry. It was observed that the electron-transfer reactivity of horseradish peroxidase was greatly enhanced, and that direct electrochemistry was accordingly feasible. Using the merits of the direct electron-transfer reactivity of horseradish peroxidase and its specific enzymatic catalysis towards hydrogen peroxide, an unmediated hydrogen peroxide biosensor was constructed. The calibration plot of this hydrogen peroxide sensor was linear in the range of 2.0 x 10(-6) mol/L - 6.5 x 10(-4) mol/L. The relative standard deviation was 4.1% for 6 successive determinations at a concentration of 1.0 x 10(-4) mol/L. The detection limit was 1.0 x 10(-6) mol/L.  相似文献   

9.
A simple, rapid and sensitive chemiluminescence (CL) method was proposed for the determination of lomefloxacin (LFX). This method is based on the fact that the weak CL from the redox reaction of Ce(4+)-Na(2)SO(3) can be greatly enhanced by the complex of Tb(3+)-LFX. The CL intensity is directly proportional to the concentration of LFX in the range 2.0x10(-9) to 1.0x10(-5) mol L(-1), and the detection limit (S/N=3) is 1.1x10(-9) mol L(-1). This method has been applied to the detection of LFX in pharmaceutical preparation, urine and serum samples. Recoveries were in the range 95-105%. The CL mechanism of Ce(4+)-Na(2)SO(3)-Tb(3+)-LFX system was proposed to be an intermolecular energy transfer from excited SO(2)(*) to LFX and an intramolecular energy transfer from LFX to Tb(3+).  相似文献   

10.
A new strategy for the preparation of a DNA-modified carbon paste electrode is developed. It is found that the anodic response of mifepristone is greatly enhanced at the dsDNA-modified carbon paste electrode comparing with that obtained at the bare electrode, while the response at a ssDNA-modified electrode is similar to bare electrode. So the dsDNA-modified electrode is employed as a sensitive biosensor for the detection of mifepristone. A linear dependence of the peak currents on the concentration is observed in the range 2.0 x 10(-7) approximately 2.0 x 10(6) mol/L, with a detection limit of 1.0 x 10(-7) mol/L. The relative standard deviation is 4.3% for six successive determinations of 1.0 x 10(6) mol/L mifepristone. The determination of mifepristone tablets is carried out and satisfactory results are obtained.  相似文献   

11.
A pressurized CEC (pCEC) coupled with on-column chemiluminescence (CL) detection was developed for direct determination of amino acids, which was based on the principle of an enhanced effect of Cu(II)-amino acid complexes on the CL reaction between luminol and hydrogen peroxide in alkaline solution. The effects of some important factors on pCEC separation and CL intensity were systemically investigated. Baseline separation of amino acids including L-histidine (L-His), L-threonine (L-Thr), and L-tyrosine (L-Tyr) was achieved by using a monolithic column with a mobile phase of 5.0x10(-3) mol/L phosphate buffer at pH 8.0 that contained 25% v/v methanol and 5.0x10(-4) mol/L luminol and 1.0x10(-5) mol/L Cu(II) at an applied voltage of -5 kV. The calibration curves of the analytes by plotting the peak height against corresponding concentration were linear over the range of 3.2x10(-6)-3.2x10(-4) mol/L for L-His, 4.1x10(-6)-4.1x10(-4) mol/L for L-Thr, and 6.0x10(-7)-3.0x10(-4) mol/L for L-Tyr. The LODs for L-His, L-Thr, and L-Tyr were 6.4x10(-7), 8.4x10(-7), and 3.0x10(-7) mol/L (S/N = 2), respectively. The proposed method was applied to the analysis of amino acid injection sample with satisfactory results. Mean recoveries for three amino acids were from 84.3 to 89.6%.  相似文献   

12.
A biosensor based on stearic acid-graphite powder modified with sweet potato (Ipomoea batatas (L.) Lam.) tissue as peroxidase source was constructed and applied in organic solvents. Several parameters were studied to evaluate the performance of this biosensor such as stearic acid-graphite powder and tissue composition, type and concentration of supporting electrolyte, organic solvents, water/organic solvent ratio (% v/v) and hydrogen peroxide concentration. After selection of the best conditions, the biosensor was applied for the determination of hydroquinone in cosmetic creams in methanol. At the peroxidase electrode hydroquinone is oxidized in the presence of hydrogen peroxide and the radical formed was reduced back electrochemically at -180 mV vs Ag/AgCl (3.0 mol L(-1) KCl). The reduction current obtained was proportional to the concentration of hydroquinone from 6.2 x 10(-5) to 1.5 x 10(-3) mol L(-1) (r = 0.9990) with a detection limit of 8.5 x 10(-6) mol L(-1). The recovery of hydroquinone from two samples ranged from 98.8 to 104.1% and an RSD lower than 1.0% for a solution containing 7.3 x 10(-4) mol L(-1) hydroquinone and 1.0 x 10(-3) mol L(-1) hydrogen peroxide in 0.10 mol L(-1) tetrabutylammonium bromide methanol-phosphate buffer solution (95:5% v/v) (n = 10) was obtained.  相似文献   

13.
Herein, montmorillonite calcium was exchanged with a cationic surfactant: cetyltrimethylammonium bromide (CTAB). The resulting CTAB-modified montmorillonite calcium (CTAB-MMT) shows higher accumulation efficiency to 4-chlorophenol compared with the unmodified MMT. At the CTAB-MMT-modified carbon paste electrode, the oxidation peak current of 4-chlorophenol remarkably increases. Based on this, a novel, sensitive and convenient electrochemical method was developed for the determination of 4-chlorophenol. The oxidation peak current of 4-chlorophenol is proportional to its concentration over the range from 5.0 x 10(-8) to 1.0 x 10(-5) mol L(-1). The limit of detection is evaluated to be 2.0 x 10(-8) mol L(-1) for 2 min accumulation. Finally this newly proposed method was successfully applied to determine 4-chlorophenol in water samples.  相似文献   

14.
制备了纳米氧化铝修饰玻碳电极(nano-Al2O3/GCE/CME),用循环伏安法(CV)、线性扫描伏安法(LSV)研究了对硫磷(TP)在nano-Al2O3/GCE/CME上的电化学行为.实验表明,该修饰电极与裸电极相比能显著提高TP的氧化还原峰电流并降低其氧化峰电位.在0.1 mol/L HAc-NaAc缓冲溶液(pH =5)中,TP在该修饰电极上产生1个不可逆的还原峰( Epc1=-0.567 V)和1对可逆氧化还原峰( Epa2=0.018 V和Epc2=-0.008 V) ,氧化峰电流与TP的浓度在2.5×10-9~1.0×10-7 mol/L和1.0×10-7~1.0×10-5 mol/L范围内具有良好的线性关系,回归方程分别为: ip(μA)=0.2529+4.201C(μmol/L), r=0.9984和ip(μA)=0.6752+0.3181C(μmol/L), r=0.9946.开路富集30 s后,检出限为1.0 ×10-9 mol/L(S/N=3).在1.0×10-5 mol/L TP试液中连续测定10次,其RSD为3.8%.用此方法测定了蔬菜中TP的含量,回收率为95. 6%~100.5% ,结果满意.  相似文献   

15.
Lei Wang 《Analytical sciences》2004,20(8):1237-1239
A new luminescence-enhancement system based on complex formation between europium and sparfloxacin in the presence of lutetium in a sodium dodecyl sulfate solution has been discovered. By adding a suitable amount of Lu3+ to the Eu-sparfloxacin-sodium dodecyl sulfate system, the luminescence can be enhanced by approximately 5-fold compared with that of the system without Lu3+. Under the optimum conditions, the luminescence intensity of the system is a linear function of the concentration of europium in the range of 1.0 x 10(-10) - 5.0 x 10(-7) mol L(-1). The detection limit of europium is 2.0 x 10(-13) mol L(-1) (S/N = 3). The system was used for the determination of trace amounts of europium in rare earth samples with satisfactory results.  相似文献   

16.
Carbon-paste electrodes (CPEs) were studied to elucidate the cathodic stripping voltammetric determination of iodine. At an accumulation potential of 1.0 V (vs. SCE), iodide was preconcentrated on CPEs via an ion-pairing reaction, followed by oxidation to iodine. Then a linear scan voltammogram was recorded after 10 s of quiescent time by a cathodic potential scan from 0.7 V to 0.1 V at a scan rate of 100 mV s(-1). A cathodic peak current was obtained at about 0.38 V. Various experiment parameters such as the acidity, chloride concentration, accumulation potential, accumulation time, concentration of cetyltrimethylammonium bromide (CTAB) and scan rate, were optimized to analyze the iodide by employing linear-scan stripping voltammetry. Under the optimal conditions, calibration curves were obtained over a wide concentration range of the iodide ion from 8 x 10(-9) mol L(-1) to 5 x 10(-6) mol L(-1) with a detection limit of 2 x 10(-9) mol L(-1) at an accumulation time of 3 min. The effect of interfering species was evaluated and the procedure was applied to an iodide analysis in table salt, with good results.  相似文献   

17.
Wang J  Chen G  Huang J 《The Analyst》2005,130(1):71-75
A glassy carbon electrode (GCE) modified with nickel(II) tetrasulfophthalocyanine (NiTSPc) and Nafion was used for the investigation of the catalytic oxidation of luminol. The modified electrode was found to much more effectively improve the emission of electrochemiluminescence(ECL) of luminol in a solution containing hydrogen peroxide. The enhanced ECL signal corresponded to the catalytic oxidation of both luminol and H(2)O(2) by NiTSPc. Attached Ni(II) on GCE was oxidised to Ni(III) and then used as the catalyst for the chemiluminescence of luminol. The enhanced stability of the ECL signal with Nafion would mainly result from the prevention of the dissolution of NiTSPc and the adsorption of the oxidation product of luminol on the electrode surface. The proposed method enables a detection limit for luminal of 6.0 x 10(-8) mol L(-1) to be achieved in the presence of H(2)O(2) in the neutral solution. The enhanced ECL intensity had a linear relationship with the concentration of luminol in the range of 1.0 x 10(-7)-8.0 x 10(-6) mol L(-1).  相似文献   

18.
A rapid, selective, and sensitive kinetic flow-injection method for iodide content determination with amperometric detection on a platinum electrode was developed. The method is based on the catalytic effect of iodide on the Mn3+ reaction with As3+ in the presence of sulfuric acid. The calibration curve was linear in the concentration range from 5.0 x 10(-7) to 1.0 x 10(-4) mol/L iodide. The limit of detection (LOD) was found to be 5.0 x 10(-9) mol/L iodide. The relative standard deviations (RSD) were 1.68% and 3.03% for 1.0 x 10(-3) mol/L standard and 1.0 x 10(-6) mol/L iodide solution (n = 6), respectively. The method has been successfully applied for determination of iodide in waters, table salts, fodder, organic substances and human blood sera. The results were compared with those obtained by a standard AOAC (Association of Official Analytical Chemists) method, as well as with those obtained by a kinetic spectrophotometric procedure for determination of iodide.  相似文献   

19.
报道了一种表面活性剂单分子层修饰碳糊电极,并用于NO的高灵敏电化学检测。研究表明,表面活性剂通过烷基链在电极表面形成的疏水性单分子层微环境对NO的电化学响应具有较好的促进作用。其中,阳离子表面活性剂十六烷基三甲基溴化铵(CTAB)对NO的电化学氧化表现出最强的催化活性和增敏作用。在Nafion膜覆盖的CTAB修饰碳糊电极上,NO的安培响应与其浓度在3.6×10-8~1.8×10-5mol/L范围内呈良好的线性关系,检出限为1.8×10-8mol/L。该电极作为低成本、高灵敏的NO电化学传感器,被成功应用于大鼠肺组织细胞中NO释放的实时监测。  相似文献   

20.
Fan C  Gao Q  Zhu D  Wagner G  Li G 《The Analyst》2001,126(7):1086-1089
Hemoglobin was incorporated in a montmorillonite membrane. Electrochemical and spectroscopic studies revealed that the electron transfer reactivity and peroxidase activity of the protein were both enhanced. Nevertheless, its structure was still maintained native-like in the membrane. An unmediated hydrogen peroxide biosensor was accordingly prepared. The calibration plot of this H202 sensor was linear in the range of 1.0 x 10(-6)-6.0 x 10(-4) mol L(-1). The relative standard deviation was 3.1% for six successive determinations at a concentration of 1.0 x 10(-4) mol L(-1). The detection limit was 6.0 x 10(-7) mol L(-1). Possible interferences in real sample analyses are discussed.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号