首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
We demonstrate polarization-sensitive measurement of the modal content of waveguides by generalizing the classic rotating wave-plate-based polarimeter to wide-field optical low-coherence interferometry. The spatial phases of the modes are retrieved with principal component analysis. By applying this polarization-sensitive cross-correlation (C2) imaging technique to the characterization of a few-mode fiber, we reveal that different modes experience distinct bend-induced birefringence in optical fibers. This polarization-resolved C2 imaging is well suited for analyzing the impact of polarization on wave propagation in high-power fiber lasers as well as in mode-division-multiplexed communications systems.  相似文献   

2.
Park BH  Pierce MC  de Boer JF 《Optics letters》2004,29(24):2873-4; discussion 2875-7
We comment on the recent Letter by Jiao et al. [Opt. Lett. 28, 1206 (2003)] in which a polarization-sensitive optical coherence tomography system was presented. Interrogating a sample with two orthogonal incident polarization states cannot always recover birefringence correctly. A previously presented fiber-based polarization-sensitive system was inaccurately characterized, and its method of eliminating the polarization distortion caused by single-mode optical fiber was presented earlier by Saxer et al. [Opt. Lett. 25, 1355 (2000)].  相似文献   

3.
Cense B  Chen TC  Park BH  Pierce MC  de Boer JF 《Optics letters》2002,27(18):1610-1612
To our knowledge, this is the first demonstration of in vivo depth-resolved birefringence measurements of the human retinal nerve fiber layer (RNFL) by use of polarization-sensitive optical coherence tomography (PS-OCT). Because glaucoma causes nerve fiber layer damage, which may cause loss of retinal birefringence, PS-OCT is a potentially useful technique for the early detection of glaucoma. We built a fiber-based PS-OCT setup that produces quasi-real-time images of the human retina in vivo . Preliminary measurements of a healthy volunteer showed that the double-pass phase retardation per unit depth of the RNFL near the optic nerve head is 39+/-6( degrees )/100microm .  相似文献   

4.
Park BH  Pierce MC  Cense B  de Boer JF 《Optics letters》2005,30(19):2587-2589
We present a generalized analysis of fiber-based polarization-sensitive optical coherence tomography with an emphasis on determination of sample optic axis orientation. The polarization properties of a fiber-based system can cause an overall rotation in a Poincaré sphere representation such that the plane of possible measured sample optic axes for linear birefringence and diattenuation no longer lies in the QU-plane. The optic axis orientation can be recovered as an angle on this rotated plane, subject to an offset and overall indeterminacy in sign such that only the magnitude, but not the direction, of a change in orientation can be determined. We discuss the accuracy of optic axis determination due to a fundamental limit on the accuracy with which a polarization state can be determined as a function of signal-to-noise ratio.  相似文献   

5.
We demonstrate that tissue structure, birefringence, and blood flow can be imaged simultaneously by use of techniques of polarization-sensitive optical coherence tomography and phase-resolved optical Doppler tomography. An efficient data-acquisition procedure is implemented that optimizes the concurrent processing and display of all three image types. Images of in vivo human skin acquired with a high-speed fiber-based system are presented.  相似文献   

6.
Guo S  Zhang J  Wang L  Nelson JS  Chen Z 《Optics letters》2004,29(17):2025-2027
Conventional polarization-sensitive optical coherence tomography (PS-OCT) can provide depth-resolved Stokes parameter measurements of light reflected from turbid media. A new algorithm that takes into account changes in the optical axis is introduced to provide depth-resolved birefringence and differential optical axis orientation images by use of fiber-based PS-OCT. Quaternion, a convenient mathematical tool, is used to represent an optical element and simplify the algorithm. Experimental results with beef tendon and rabbit tendon and muscle show that this technique has promising potential for imaging the birefringent structure of multiple-layer samples with varying optical axes.  相似文献   

7.
Jiao S  Yu W  Stoica G  Wang LV 《Optics letters》2003,28(14):1206-1208
An optical-fiber-based multichannel polarization-sensitive Mueller optical coherence tomography (OCT) system was built to acquire the Jones or Mueller matrix of a scattering medium, such as biological tissue. For the first time to our knowledge, fiber-based polarization-sensitive OCT was dynamically calibrated to eliminate the polarization distortion caused by the single-mode optical fiber in the sample arm, thereby overcoming a key technical impediment to the application of optical fibers in this technology. The round-trip Jones matrix of the sampling fiber was acquired from the reflecting surface of the sample for each depth scan (A scan) with our OCT system. A new rigorous algorithm was then used to retrieve the calibrated polarization properties of the sample. This algorithm was validated with experimental data. The skin of a rat was imaged with this fiber-based system.  相似文献   

8.
An improved polarization-sensitive optical coherence tomography (OCT) system is developed and used to measure birefringence in porcine myocardium tissue and produce two-dimensional birefringence mapping of the tissue. Signal-to-noise issues that cause systematic measurement errors are analyzed to determine the regime in which such measurements are accurate. The advantage of polarization-sensitive OCT systems over standard OCT systems in avoiding image artifacts caused by birefringence is also demonstrated.  相似文献   

9.
Saxer CE  de Boer JF  Park BH  Zhao Y  Chen Z  Nelson JS 《Optics letters》2000,25(18):1355-1357
A high-speed single-mode fiber-based polarization-sensitive optical coherence tomography (PS OCT) system was developed. With a polarization modulator, Stokes parameters of reflected flight for four input polarization states are measured as a function of depth. A phase modulator in the reference arm of a Michelson interferometer permits independent control of the axial scan rate and carrier frequency. In vivo PS OCT images of human skin are presented, showing subsurface structures that are not discernible in conventional OCT images. A phase retardation image in tissue is calculated based on the reflected Stokes parameters of the four input polarization states.  相似文献   

10.
This work presents polarization-sensitive optical coherence tomography (PS-OCT) using only linearly polarized light. The main characteristics of linear PS-OCT include the following. (1) In a turbid medium with linear birefringence, the degree of polarization (DOP) of backscattered linearly incident polarized light does not change significantly with the increase of birefringence value; (2) the phase retardation of the sample can be obtained from only the phase difference between the orthogonal polarization heterodyne signals, so a common phase noise rejection mode is introduced. These advantages may not only support the immunity of background phase noise and laser frequency noise, but also increase the sensitivity of phase retardation measurements; (3) the dynamic range of phase retardation in this system is between 0° and 180°  相似文献   

11.
Park BH  Pierce MC  Cense B  de Boer JF 《Optics letters》2004,29(21):2512-2514
We present an analysis for polarization-sensitive optical coherence tomography that facilitates the unrestricted use of fiber and fiber-optic components throughout an interferometer and yields sample birefringence, diattenuation, and relative optic axis orientation. We use a novel Jones matrix approach that compares the polarization states of light reflected from the sample surface with those reflected from within a biological sample for pairs of depth scans. The incident polarization alternated between two states that are perpendicular in a Poincaré sphere representation to ensure proper detection of tissue birefringence regardless of optical fiber contributions. The method was validated by comparing the calculated diattenuation of a polarizing sheet, chicken tendon, and muscle with that obtained by independent measurement. The relative importance of diattenuation versus birefringence to angular displacement of Stokes vectors on a Poincaré sphere was quantified.  相似文献   

12.
Oh WY  Vakoc BJ  Yun SH  Tearney GJ  Bouma BE 《Optics letters》2008,33(12):1330-1332
We demonstrate a novel high-speed polarization-sensitive optical frequency domain imaging system employing high-speed polarization modulation. Rapid and continuous polarization modulation of light prior to illumination of the sample is accomplished by shifting the frequency of one polarization eigenstate by an amount equal to one quarter of the digitization sampling frequency. This approach enables polarization-sensitive imaging with a single detection channel and overcomes artifacts that may arise from temporal variations of the birefringence in fiber-optic imaging probes and spatial variation of birefringence in the sample.  相似文献   

13.
Lu Z  Matcher SJ 《Optics letters》2012,37(11):1931-1933
We report on a new calibration technique that permits the accurate extraction of sample Jones matrix and hence fast-axis orientation by using fiber-based polarization-sensitive optical coherence tomography (PS-OCT) that is completely based on non-polarization-maintaining fiber such as SMF-28. In this technique, two quarter-wave plates (QWPs) are used to completely specify the parameters of the system fibers in the sample arm so that the Jones matrix of the sample can be determined directly. The device was validated on measurements of a QWP and an equine tendon sample by a single-mode fiber-based swept-source PS-OCT system.  相似文献   

14.
Using a low-coherence Michelson interferometer, we measure two-dimensional images of optical birefringence in bovine tendon as a function of depth. Polarization-sensitive detection of the signal formed by interference of backscattered light from the sample and a mirror in the reference arm give the optical phase delay between light that is propagating along the fast and slow axes of the birefringent tendon. Images showing the change in birefringence in response to laser irradiation are presented. The technique permits rapid noncontact investigation of tissue structural properties through two-dimensional imaging of birefringence.  相似文献   

15.
Choma MA  Yang C  Izatt JA 《Optics letters》2003,28(22):2162-2164
We describe fiber-based quadrature low-coherence interferometers that exploit the inherent phase shifts of 3 x 3 and higher-order fiber-optic couplers. We present a framework based on conservation of energy to account for the interferometric shifts in 3 x 3 interferometers, and we demonstrate that the resulting interferometers provide the entire complex interferometric signal instantaneously in homodyne and heterodyne systems. In heterodyne detection we demonstrate the capability for extraction of the magnitude and sign of Doppler shifts from the complex data. In homodyne detection we show the detection of subwavelength sample motion. N x N (N > 2) low-coherence interferometer topologies will be useful in Doppler optical coherence tomography (OCT), optical coherence microscopy, Fourier-domain OCT, optical frequency domain reflectometry, and phase-referenced interferometry.  相似文献   

16.
We report on a modification of optical coherence tomography (OCT) that allows one to measure small phase differences between beams traversing adjacent areas of a specimen. The sample beam of a polarization-sensitive low-coherence interferometer is split by a Wollaston prism into two components that traverse the object along closely spaced paths. After reflection at the various sample surfaces, the beams are recombined at the Wollaston prism. Any phase difference encountered between the two beams is converted into a change of polarization state of the recombined beam. This change is measured, and the resulting signals are converted to differential phase-contrast OCT images. The first images obtained from simple test objects allowed us to determine path-difference gradients with a resolution of the order of 5 x 10(-5) .  相似文献   

17.
Jiao S  Wang LV 《Optics letters》2002,27(2):101-103
A double-beam polarization-sensitive system based on optical coherence tomography was built to measure the Mueller matrix of scattering biological tissue with high spatial resolution. The Jones matrix of a sample can be determined with a single scan and subsequently converted into an equivalent nondepolarizing Mueller matrix. As a result, the system can be used to measure the Mueller matrix of an unstable sample, such as soft tissue. The polarization parameters of a porcine tendon, including magnitude and orientation of birefringence and diattenuation, were extracted by decomposition of the measured Mueller matrix.  相似文献   

18.
高阳  万新军  解树平 《应用光学》2022,43(2):284-290
应力检测对光学元件的制造和使用意义重大。基于应力双折射原理,提出了一种利用偏振相机测量应力分布的方法。根据Stokes矩阵和Mueller矩阵推导出应力值及应力方向计算公式,并对影响系统测量精度的主要误差进行了理论分析。为验证方法的可行性,搭建了一台测量应力分布的装置。使用该装置测量一块633 nm的四分之一波片,测得其误差为0.86 nm。进一步测量,得出一块车灯透镜的全场应力相位延迟量与应力方向图,利用所测相位延迟量计算出透镜中心区域的应力双折射值为9.21 nm/mm、主应力差为2.45 MPa;利用符号规则调整了透镜的应力方向,结果符合应力连续性原则。该方法测量应力分布时无需旋动光学元件,可实现应力延迟量及应力方向的实时测量。  相似文献   

19.
李昭莹  谢芳  马森  刘义秦 《光学学报》2012,32(6):612004-95
研究一种能够进行远程及绝对测量的光纤低相干干涉传感系统。该系统包含两个光纤干涉仪,其中一个光纤干涉仪置于被测场中感应被测量的变化,可实现远程测量;另一个光纤干涉仪解调被测量的值。运用波分复用技术,使用于解调的光纤干涉仪同时工作于低相干干涉和高相干干涉状态。用低相干干涉信号决定被测量的幅值,对被测量实现绝对测量,并使测量量程不受波长限制;同时,用高相干干涉信号对被测量进行高精度的测量。系统的测量量程为6mm,测量分辨率小于1nm,位移实验结果的线性相关系数R为0.99。  相似文献   

20.
We use the Pancharatnam-Berry phase as a multifunctional tool for low-coherence interferometry. This geometric phase shift enables instantaneous retrieval of the quadrature components of the complex interferometric signal. The phase shift is independent of wavelength and allows for a complex conjugate suppression of 40?dB for an optical bandwidth of 115?nm. Furthermore, this paper investigates the versatility of the geometric phase to perform polarization sensitive measurements. The Jones vector of the sample was obtained numerically, allowing sample birefringence and optical axis calculation.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号