首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
E. Azad 《Heat and Mass Transfer》2011,47(12):1651-1658
The thermal performance of co-axial heat pipe solar collector which consist of a collector 15 co-axial heat pipes surrounded by a transparent envelope and which heat a fluid flowing through the condenser tubes have been predicted using heat transfer analytical methods. The analysis considers conductive and convective losses and energy transferred to a fluid flowing through the collector condenser tubes. The thermal performances of co-axial heat pipe solar collector is developed and are used to determine the collector efficiency, which is defined as the ratio of heat taken from the water flowing in the condenser tube and the solar radiation striking the collector absorber. The theoretical water outlet temperature and efficiency are compared with experimental results and it shows good agreement between them. The main advantage of this collector is that inclination of collector does not have influence on performance of co-axial heat pipe solar collector therefore it can be positioned at any angle from horizontal to vertical. In high building where the roof area is not enough the co-axial heat pipe solar collectors can be installed on the roof as well as wall of the building. The other advantage is each heat pipe can be topologically disconnected from the manifold.  相似文献   

2.
3.
The performance of heat pipe solar collector is investigated theoretically and experimentally. The system employs wick-assisted heat pipe for the heat transfer from the absorber (evaporator) to a heat exchanger (condenser). The heat pipe is made with a copper tube and the evaporator section is finned with aluminium plate. Theoretical model predicts the outlet water from heat exchanger, heat pipe temperature and also the thermal efficiency of solar collector. The results are compared with experimental data.  相似文献   

4.
Investigation and analysis on a cellular heat pipe flat solar heater   总被引:2,自引:0,他引:2  
A new cellular heat pipe flat solar energy collector is introduced, and the thermal performance of the new solar heater comprised by water heat pipe or acetone heat pipe is tested. The results are compared with the performance of the evacuated glass tube solar heater. It is found that: the heat loss coefficient of the cellular heat pipe flat solar heater is 54% less than that of the evacuated glass tube solar heater, while the daily average efficiency of solar absorbency is 15% higher, when the water temperature of heating is lower than 65°C. In conclusion, the thermal performance of such new solar heater is better than that of evacuated glass tube solar heater or ordinary flat solar heater, both of which are still popular in China. This new solar energy application promises to be a prosperous technology.  相似文献   

5.
6.
This paper presents alternative approach in heat transfer analysis of plate heat exchangers. In order to obtain heat transfer rate and effectiveness values of plate heat exchanger, neural network (NN) approach was used. Experimentally, system used in plate heat exchanger for heating and cooling applications was designed and constructed. Experimental data were used for training and testing network. The training and validation were performed with good accuracy. The correlation coefficient obtained when unknown data were applied to the networks was 0.9994 for heat transfer rate and 0.9976 for effectiveness, which is very satisfactory. Using the weights obtained from the trained network, a new formulation is presented for determination of heat transfer rate and effectiveness. This formulation can provide simplicity in thermal analysis of plate heat exchanger. The presented procedure can also help to heat exchanger designer and manufacturer.  相似文献   

7.
An effective thermal spreader can achieve uniform heat flux distribution and thus enhance heat dissipation of heat sinks. Flat plate heat pipe is one of the highly effective thermal spreaders. Magnetic fluid is liquid and can be moved by the force of magnetic field. Therefore, the magnetic fluid is suitable to be used as the working fluid of flat plate heat pipes which have a very small gap between evaporation and condensation surfaces. We prepared a disk-shaped wickless flat plate heat pipe, and the distance between evaporation and condensation surfaces is only 1 mm. From experimental study, the effect of heat flux and working fluid ratio on the performance of flat plate heat pipe is presented. Also we compared the experimental results between the performance of water and magnetic fluid as working fluids.  相似文献   

8.
In the present study, sizing of a single pass cross flow heat exchanger with unmixed fluid streams has been investigated. The heat exchanger is a cross flow heat exchanger. It has overall dimensions of 20 × 20 × 20 cm. Two the most common heat exchanger design problems are the rating and sizing problem. Sizing problems deal with designing an exchanger and determining its physical size to meet the specified heat duty, pressure drops and other considerations. It means the determination of the exchanger construction type, flow arrangement, heat transfer surface geometries and materials, and the physical sizes of an exchanger to meet specified heat transfer and pressure drop. In this study, the physical size (length, width, height, mass flow rates of both fluids and surface areas on each side of the exchanger) are determined. Inputs to the sizing problem are surface geometries, fluid mass flow rates, inlet and outlet fluid temperatures and pressure drop on each side. Dimensions of L a , L b , and L c for the selected surfaces were investigated such that the design meets the heat duty and pressure drops on both sides exactly.  相似文献   

9.
Sensitivity analysis is a mathematical tool, first developed for optimization methods, which aim is to characterize a system response through the variations of its output parameters following modifications imposed on the input parameters of the system. Such an analysis may quickly become laborious when the thermal model under consideration is complex or the number of input parameters is high. In this paper, we develop a mathematical model to analyse the heat exchanges in four different types of solar air collectors. When building this thermal model we show that for each collector, at quasi-steady state, the energy balance equations of the components of the collector cascade into a single first-order non-linear differential equation that is able to predict the thermal behaviour of the collector. Our heat transfer model clearly demonstrates the existence of an important dimensionless parameter, referred to as the thermal performance factor of the collector, that compares the useful thermal energy which can be extracted from the heater to the overall thermal losses of that collector for a given set of input parameters. A sensitivity analysis of our thermal model has been performed for the most significant input parameters such as the incident solar irradiation, the inlet fluid temperature, the air mass flow rate, the depth of the fluid channel, the number and nature of the transparent covers in order to measure the impact of each of these parameters on our model. An important result which can be drawn from this study is that the heat transfer model developed is robust enough to be used for thermal design studies of most known flat plate solar air heaters, but also of flat plate solar water collectors and linear solar concentrators.  相似文献   

10.
The flow structure in a flat plate integrated collector storage device, with recirculation of the storage water, is studied experimentally and theoretically. To facilitate flow visualization, an experimental device was constructed by transparent material (Plexiglas). Flow velocities and fluctuations are measured, using a LDV system. A three-dimensional CFD-model was developed using the FLUENT code. The standard kω model is selected as the most appropriate. The model is validated, with good agreement, against experimental measurements. Furthermore, copper tubes, in the form of embedded heat exchanger, are placed inside the device and another similar 3D model was developed. The model was used to examine the behavior of the system, when the service water enters the heat exchanger, thus being indirectly heated by the stored hot water. It is shown that the outlet temperature of the service water is enough higher, when recirculation occurs.  相似文献   

11.
An experimental study on the thermal performance of ground heat exchanger   总被引:4,自引:0,他引:4  
A knowledge of ground thermal properties is most important for the proper design of large GHE (ground heat exchanger) systems. Thermal response tests have so far been used primarily not only for in situ determination of design data for GHE systems, but also for the evaluation of grout material, heat exchanger types and groundwater effects. The main purpose has been to determine in situ values of effective ground thermal conductivity, including the effect of groundwater flow and natural convection in boreholes.  相似文献   

12.
A numerical solution of the convective heat transfer in the thermal entry region of the finned double‐pipe is carried out for the case of hydro‐dynamically fully developed flow when subjected to uniform wall temperature boundary condition. Adaptive axial grid size is used in order to cater for the variation of large solution gradients in the axial direction. It has been observed that the thermal entrance region is highly effective and there is a substantial enhancement in the heat transfer coefficient. A maximum of 76.4877% increase has been observed in the thermal entrance region as compared with the fully developed region for 24 fins and H*=0.6 when R?=0.25, whereas for R?=0.5 the maximum increase is 75.0308% for the same number of fins of same height. It has been observed that no geometry consistently perform better throughout the entrance region. However, the geometries that have optimal performance in the fully developed region perform better in the developing region on average terms. Results show that the Nusselt number and the thermal entrance length are dependent upon various geometrical parameters such as ratio of radii of the inner and the outer pipe, fin height and the number of fins. The limiting case results match well with the literature results. This validates our numerical procedure and computer code. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

13.
An experimental study on operation performance of ice storage air-conditioning system with separate helical heat pipe is conducted in this paper. The experimental system of ice storage air-conditioning system with separate heat pipe is set up. The performance parameters such as the evaporation pressure and the condensation pressure of refrigeration system, the refrigeration capacity and the COP (coefficient of performance) of the system, the IPF (ice packing factor) and the cool storage capacity in the cool storage tank during charging period, and the cool discharge rate and the cool discharge capacity in the cool storage tank, the outlet water temperature in the cool storage tank and the outlet air temperature in room unit during discharging period are investigated. The experimental results show that the ice storage air-conditioning system with separate helical heat pipe can stably work during charging and discharging period. This indicates that the ice storage air-conditioning system with separate helical heat pipe is well adapted to cool storage air-conditioning systems in building.  相似文献   

14.
In the present work, the effect of the use of a nanofluid in a miniature plate heat exchanger (PHE) with modulated surface has been studied both experimentally and numerically. First, the thermophysical properties (i.e., thermal conductivity, heat capacity, viscosity, density and surface tension) of a typical nanofluid (CuO in water, 4% v/v) were systematically measured. The effect of surface modulation on heat transfer augmentation and friction losses was then investigated by simulating the existing miniature PHE as well as a notional similar PHE with flat plate using a CFD code. Finally, the effect of the nanofluid on the PHE performance was studied and compared to that of a conventional cooling fluid (i.e., water). The results suggest that, for a given heat duty, the nanofluid volumetric flow rate required is lower than that of water causing lower pressure drop. As a result, smaller equipment and less pumping power are required. In conclusion, the use of the nanofluids seems to be a promising solution towards designing efficient heat exchanging systems, especially when the total volume of the equipment is the main issue. The only drawbacks so far are the high price and the possible instability of the nanoparticle suspensions.  相似文献   

15.
16.
In this study, artificial neural networks (ANNs) and adaptive neuro-fuzzy (ANFIS) in order to predict the thermal performance of evacuated tube solar collector system have been used. The experimental data for the training and testing of the networks were used. The results of ANN are compared with ANFIS in which the same data sets are used. The R2-value for the thermal performance values of collector is 0.811914 which can be considered as satisfactory. The results obtained when unknown data were presented to the networks are satisfactory and indicate that the proposed method can successfully be used for the prediction of the thermal performance of evacuated tube solar collectors. In addition, new formulations obtained from ANN are presented for the calculation of the thermal performance. The advantages of this approaches compared to the conventional methods are speed, simplicity, and the capacity of the network to learn from examples. In addition, genetic algorithm (GA) was used to maximize the thermal performance of the system. The optimum working conditions of the system were determined by the GA.  相似文献   

17.
The present article reports on heat transfer characteristics associated with multiple laminar impinging air jet cooling a hot flat plat at different orientations. The work aims to study the interactions of the effects of cross flow, buoyancy induced flow, orientation of the hot surface with respect to gravity, Reynolds numbers and Rayleigh numbers on heat transfer characteristics. Experiments have been carried out for different values of jet Reynolds number, Rayleigh number and cross flow strength and at different orientations of the air jet with respect to the target hot plate. In general, the effective cooling of the plate has been observed to be increased with increasing Reynolds number and Rayleigh number. The results concluded that the hot surface orientation is important for optimum performance in practical applications. It was found that for Re ≥ 400 and Ra ≥ 10,000 (these ranges give 0.0142 ≤ Ri ≤ 1.59 the Nusselt number is independent on the hot surface orientation. However, for Re ≤ 300 and Ra ≥ 100,000 (these ranges give 1.59 ≤ Ri ≤ 42.85): (i) the Nusselt number for horizontal orientation with hot surface facing down is less that that of vertical orientation and that of horizontal orientation with hot surface facing up, and (ii) the Nusselt number of vertical orientation is approximately the same as that of horizontal orientation with hot surface facing up. For all surfaces orientations and for the entire ranges of Re and Ra, it was found that increasing the cross flow strength decreases the effective cooling of the surface.  相似文献   

18.
The influence of partial slip, thermal radiation and temperature dependent fluid properties on the hydro-magnetic fluid flow and heat transfer over a flat plate with convective surface heat flux at the boundary and non-uniform heat source/sink is studied. The transverse magnetic field is assumed as a function of the distance from the origin. Also it is assumed that the fluid viscosity and the thermal conductivity vary as an inverse function and linear function of temperature respectively. Using the similarity transformation, the governing system of non-linear partial differential equations are transformed into similarity non-linear ordinary differential equations and are solved numerically using symbolic software MATHEMATICA 7.0. The numerical values obtained within the boundary layer for the dimensionless velocity, temperature, skin friction coefficient and the Nusselt number are presented through graphs and tables for several sets of values of the parameters. The effects of various physical parameters on the flow and heat transfer characteristics are discussed from the physical point of view.  相似文献   

19.
The analysis of the heat transfer in flow past a continuously moving semi-infinite plate in the presence of suction/ injection with heat flux has been presented. Similarity solutions have been derived and the resulting equations are integrated numerically. It has been observed that an increase in suction value leads to an increase in temperature whereas it is opposite in the case of injection.
Wärmeübergang in einer Strömung hinter einer wärmeabgebenden, kontinuierlich bewegten, porösen Platte
Zusammenfassung Es wird eine Analyse des Wärmeübergangs in einer Strömung hinter einer bewegten, halbunendlichen Platte bei gleichzeitiger Absaugung bzw. Ausströmung präsentiert. Mit Hilfe von Ähnlichkeitsbetrachtungen wurden Lösungen erarbeitet und die daraus resultierenden Gleichungen wurden numerisch integriert. Als Ergebnis zeigte sich, daß zunehmende Absaugung zu einer Erhöhung der Temperatur führt, während bei der Ausströmung das Gegenteil der Fall ist.
  相似文献   

20.
The subsonic flow of an ideal compressible gas around the rear end of a semiinfinite flat plate in a pipe is considered. The flow pattern is similar to that assumed by Efros [1, 2] with a return stream for the cavitational flows. Fal'kovich's method [3] is used to solve the problem and this makes it possible to obtain the solution to the problems of the gas streams at several typical velocities. The method is a generalization of that of Chaplygin [4] for flow problems at one typical velocity.Translated from Izvestiya Akademii Nauk SSSR, Mekhanika Zhidkosti i Gaza, No. 4, pp. 101–108, July–August, 1970.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号