首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Truedsson LA  Smith BE 《Talanta》1979,26(6):487-491
A general method is described for the coulometric titration of alkylanilines with anodically generated bromine. The reaction is carried out in water-acetic acid medium and the reactivity is governed by varying the water content and the concentration of bromide ion and by the addition of pyridine. In this way most types of alkylanilines can be titrated quantitatively. Unlike the case for alkylphenols, the bromine consumption is not always higher in the pyridine-containing media than in the pyridine-free. The bromine consumption is also more dependent on the bromide content of the medium than it is for alkylphenols. The mean relative error, for the best medium for each compound, is +/-0.9% for primary alkylanilines, +/-0.9% for secondary and +/-1.2% for tertiary.  相似文献   

2.
A method is described for measuring free, total, and esterified cholesterol in blood serum in which reversed-phase liquid chromatography is used and the eluate is monitored at 200 nm. The sample for total cholesterol is prepared according to the Abell-Kendall procedure, and for free cholesterol an extract of serum--isopropanol (1:5, v/v) is used. The column is a muBondapak C18, 10 micrometers, and the mobile phase for total cholesterol is isopropanol--acetonitrile (50:50, v/v); for free cholesterol, it is isopropanol--acetonitrile--water (60:30:10). An approximation of the free cholesterol, triglycerides, and individual cholesteryl esters is obtained from single chromatograms of isopropanol extracts of serum if the first mobile phase is used. In a comparison study with the Abell-Kendall method for total cholesterol, the correlation is excellent and the precision is acceptable.  相似文献   

3.
Reddi GS  Pao CR  Muralidhar HS 《Talanta》1993,40(9):1433-1435
A mixture of nitric and sulphuric acids is used for the decomposition of geochemical samples for the estimation of tungsten. In the resulting sample solution tungsten is determined colorimetrically by the dithiol method. The decomposition procedure suggested works well for scheelite mineral. However wolframite is only partially decomposed. The same sample solution is used for estimation of molybdenum by the thiocyanate method. The method is suitable for batch analysis and results in a high throughput.  相似文献   

4.
D.S. Wulfman 《Tetrahedron》1976,32(11):1231-1240
A systematology for carbene transfer (MT) processes based on apparent molecularities of the product determining step is proposed. An analysis is made of potential conformation effects for copper(I) and copper(II) based carbenoids and a systematology for purposes of nomenclature is proposed for conformations of penta-coordinated systems based upon trigonal bipyramides and tetragonal pyramides. The possible role of valence state is examined and the hazards of applying spin state correlations to carbenoids in parallel with the methods used for carbenes is discussed. Basic guidelines for generating data suitable for internal and external comparisons are given.  相似文献   

5.
《Analytica chimica acta》1987,203(1):43-54
The method of moments is described for deconvolution of a mixture of identical distributions; it is not necessary to know the type of the individual peak distribution. The algorithm for computing the positions and contributions of the peaks forming the multiplet is presented. The real shape of the peak is used. The computational stability of the method of moments for the deconvolution of various types of convolved triple peaks is shown to be satisfactory. The algorithm is used for deconvolution of some double peaks obtained in neutron activation analysis of rock standards. The program is fast and suitable for microcomputers.  相似文献   

6.
S Masuko  S Kasahara 《Radioisotopes》1985,34(10):559-562
Utilization of the computer for radiation control is planned and performed in many radioisotope laboratories. But each laboratory has their own situation which makes the planning difficult with respect to the hardware and particularly to the software. What is the most important is that the practice of radiation management is different for each laboratory both in point of view and in the form of recording. Therefore, the computer program for the radiation management, especially for the management of radioisotopes is required to meet many amendments. In this standpoint, we have developed a "programless language" or "programless software" and have used in our work for several years. As the result of our experience, we have found that the programless language is quite satisfactory for the management of radioisotopes and that it has an advantage in some aspects over conventional programs. It is thought that this "programless language" is effective not only for our own works, but also applicable to other radioisotope laboratories.  相似文献   

7.
Johansen O  Steinnes E 《Talanta》1970,17(5):407-414
A neutron-activation method for the simultaneous determination of cobalt, copper, gallium, iron, tungsten and zinc in rocks is described. The method is based on anion-excbange separation in hydrochloric acid media. Chemical yield is higher than 97% for all elements, except for tungsten, where the recovery of the carrier is established by re-activation. The precision is about 1-3% for the iron determination and about 3% for cobalt, copper, gallium and zinc.  相似文献   

8.
Gas bubbles in simulation and experiment   总被引:1,自引:0,他引:1  
An experimental setup for the examination of single bubbles, rising in a liquid, is presented. Its main part is a rotating chamber, in which the bubble is spatially stabilized by a balance of buoyancy, drag, and lift forces. This allows for long observation periods in time. Experimental results are presented for air bubbles in silicone oil. The experimental results are validated by a comparison with numerical simulations. A modified, mass-conserving level-set method is used for the representation of the free interface, while an immersed-boundary formulation is engaged for the conservation equations. The agreement between experiment and simulation, and to available correlations from literature, is found to be perfect. It is shown that the influence of the liquid shear due to the rotation is negligible. Also, for the presented liquid system, no influence by Marangoni stresses could be found, which makes the system of air and silicone oil a good choice for validation purposes.  相似文献   

9.
A method for the determination of a synthetic polymeric compound with antitumor activity (copovithane) and methylamine in blood plasma and urine is described. Copovithane is prepared by radical polymerisation of a diurethane with N-vinylpyrrolidone. The method is based on high-performance liquid chromatography of the methylamine hydrochloride which arises during the hydrochloric acid hydrolysis of the parent substance. The methylamine hydrochloride is converted to the trinitrobenzenesulphonyl derivative for the purpose of chromatographic detection. The limit of determination for copovithane in blood plasma is 1.2 mg/l and in urine 1.5 mg/day. The determination limit for methylamine in blood plasma is 0.2 mg/l and in urine 0.3 mg/day. The imprecision is dependent on the sample, and amounts to +/- 6.8% for blood plasma and +/- 6.4% for urine.  相似文献   

10.
Pantůcek M 《Talanta》1967,14(6):643-653
The permanganate oxidation of methyl methacrylate in weakly acidic solution yields methyl pyruvate. Hydroxylamine hydrochloride is used for destroying the excess of permanganate. At the same time it is consumed for oximation of the pyruvate, and the resulting oxime is determined polarographically. The reaction scheme of permanganate oxidation of methyl methacrylate is suggested and optimum working conditions are found both for permanganate oxidation and for polarographic determination. The method is used for the determination of vapours of methyl methacrylate in the air, for industrial hygiene purposes.  相似文献   

11.
Measurement of total nitrogen by Kjeldahl analysis is the historical reference method for determination of the protein content of dairy products and is used for both calibration and validation of alternative methods for protein determination. Accurate evaluation of alternative methods is not possible if there is large uncertainty regarding the reference values. When Kjeldahl analysis is used to establish reference values, the performance of the Kjeldahl testing must be verified and within established expectations. Advice is given for Kjeldahl system optimization, evaluation of test results, and trouble-shooting. Techniques for successful Kjeldahl nitrogen analysis of dairy products other than milk are discussed.  相似文献   

12.
The orbital relaxation energy is defined for single and double ionizations of valence electrons, and is calculated for CH4, NH3, H2O and HF molecules with the ab initio SCF method. It is shown that the orbital relaxation energy for the ionization from a bonding orbital is about half of that for a non-bonding orbital, and the orbital relaxation energy for the double ionization is about double of that for the single ionization. This result gives a theoretical foundation for the empirical method of interpret Auger electron spectra by using experimental single ionization potentials.  相似文献   

13.
A statistical mechanical theory for heat flow is developed based upon the second entropy for dynamical transitions between energy moment macrostates. The thermal conductivity, as obtained from a Green-Kubo integral of a time correlation function, is derived as an approximation from these more fundamental theories, and its short-time dependence is explored. A new expression for the thermal conductivity is derived and shown to converge to its asymptotic value faster than the traditional Green-Kubo expression. An ansatz for the steady-state probability distribution for heat flow down an imposed thermal gradient is tested with simulations of a Lennard-Jones fluid. It is found to be accurate in the high-density regime at not too short times, but not more generally. The probability distribution is implemented in Monte Carlo simulations, and a method for extracting the thermal conductivity is given.  相似文献   

14.
Lichen (species Trypethelium Eluteriae) is analysed for different elements. Nondestructive instrumental neutron activation analysis is employed for the multielemental analysis. Gamma-ray spectrometry is used for the identification and quantitative estimation of elements. Concentrations of 24 elements are reported. Gamma-ray spectrum of the lichen irradiated for 16 hours, delayed for 10 days, and counted for 10 hours on a 50 cm3 coaxial Ge(Li) detector is given.  相似文献   

15.
Liu RM  Liu DJ  Sun AL 《Talanta》1993,40(4):511-514
A flow injection system is described for the simultaneous determination of copper and zinc with a single detector. Two sample plugs are injected into the same carrier stream sequentially. One is for zinc determination and the other is for the sum of copper and zinc. For zinc determination, copper masking reagent is simultaneously injected into a parallel carrier stream and merged with the sample plug by using the merging zone technique. Zincon is used as the colour reagent for the spectrophotometric determination of copper and zinc. The results for the analysis of serum by the proposed method correspond well with those obtained by an AAS method. The rate of analysis is about 45 samples/hr.  相似文献   

16.
Internal reformation of low steam methane fuel is important for the high e ciency and low cost operation of solid oxide fuel cell. Understanding and overcoming carbon deposition is crucial for the technology development. Here a multi-physics model is established for the relevant experimental cells. Balance of electrochemical potentials for the electrochemical reactions, generic rate expression for the methane steam reforming, dusty gas model in a form of Fick's model for anode gas transport are used in the model. Excellent agreement between the theoretical and experimental current-voltage relations is obtained, demonstrating the validity of the proposed theoretical model. The steam reaction order in low steam methane reforming reaction is found to be 1. Detailed information about the distributions of physical quantities is obtained by the numerical simulation. Carbon deposition is analyzed in detail and the mechanism for the coking inhibition by operating current is illustrated clearly. Two expressions of carbon activity are analyzed and found to be correct qualitatively, but not quantitatively. The role of anode diffusion layer on reducing the current threshold for carbon removal is also explained. It is noted that the current threshold reduction may be explained quantitatively with the carbon activity models that are only qualitatively correct.  相似文献   

17.
Benzohydroxamic acid (I) or phenylacetylhydroxamic acid (II) is suggested for the quantitative separation of tantalum from niobium in an oxalate solution. The tantalum precipitate must be ignited for weighing; niobium is determined in the filtrate with another reagent. The pH range for complete separation is 4.0–6.4 for I and 4.5–6.2 for II. Single precipitation is satistactory for Nb: Ta ratios of 18 : 1 to 1 : 20 for I, and 8 : 1 to 1 : 23 for II. Titanium, zirconium, tartrate, citrate and a large excess of oxalate interfere.  相似文献   

18.
Cathodic and anodic stripping voltammetry are proposed for the simultaneous determination of chloride, bromide and lead in atmospheric particulate matter. Particulate matter collected on Nucleopore membrane filters with high-volume pumps is digested in a dilute nitric acid wash at elevated temperature and pressure for 1 h. The sample is then removed to the electrochemical cell and analyzed directly for chloride and bromide by cathodic stripping and for lead by anodic stripping. The total amount of halide is first determined and then, by changing the deposition potential, the amount of bromide only is determined. The chloride is found indirectly by difference. Analysis time for the three elements is approximately 20 min beginning with a prepared sample.  相似文献   

19.
An analytical study is presented for the transient electrophoretic response of a circular cylindrical particle to the step application of an electric field. The electric double layer adjacent to the particle surface is thin but finite compared with the radius of the particle. The time‐evolving electroosmotic velocity at the outer boundary of the double layer is utilized as a slip condition so that the transient momentum conservation equation for the bulk fluid flow is solved. Explicit formulas for the unsteady electrophoretic velocity of the particle are obtained for both axially and transversely applied electric fields, and can be linearly superimposed for an arbitrarily‐oriented applied field. If the cylindrical particle is neutrally buoyant in the suspending fluid, the transient electrophoretic velocity is independent of the orientation of the particle relative to the applied electric field and will be in the direction of the applied field. If the particle is different in density from the fluid, then the direction of electrophoresis will not coincide with that of the applied field until the steady state is attained. The growth of the electrophoretic mobility with the elapsed time for a cylindrical particle is substantially slower than for a spherical particle.  相似文献   

20.
This work proposes a theoretical model for predicting the apparent equilibrium contact angle of a liquid on an ideal rough surface that is homogeneous and has a negligible body force, line tension, or contact angle hysteresis between solid and liquid. The model is derived from the conservation equations and the free-energy minimization theory for the changes of state of liquid droplets. The work of adhesion is expressed as the contact angles in the wetting process of the liquid droplets. Equilibrium contact angles of liquid droplets for rough surfaces are expressed as functions of the area ratios for the solid, liquid, and surrounding gas and the roughness ratio and wetting ratio of the liquid on the solid for the partially and fully wet states. It is found that the ideal critical angle for accentuating the contact angles by the surface roughness is 48°. The present model is compared with existing experimental data and the classical Wenzel and Cassie-Baxter models and agrees with most of the experimental data for various surfaces and liquids better than does the Wenzel model and accounts for trends that the Wenzel model cannot explain.  相似文献   