首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
2.
The development of molecular materials with novel functionality offers promise for technological innovation. Switchable molecules that incorporate redox-active components are enticing candidate compounds due to their potential for electronic manipulation. Lanthanoid metals are most prevalent in their trivalent state and usually redox-activity in lanthanoid complexes is restricted to the ligand. The unique electronic and physical properties of lanthanoid ions have been exploited for various applications, including in magnetic and luminescent materials as well as in catalysis. Lanthanoid complexes are also promising for applications reliant on switchability, where the physical properties can be modulated by varying the oxidation state of a coordinated ligand. Lanthanoid-based redox activity is also possible, encompassing both divalent and tetravalent metal oxidation states. Thus, utilization of redox-active lanthanoid metals offers an attractive opportunity to further expand the capabilities of molecular materials. This review surveys both ligand and lanthanoid centered redox-activity in pre-existing molecular systems, including tuning of lanthanoid magnetic and photophysical properties by modulating the redox states of coordinated ligands. Ultimately the combination of redox-activity at both ligands and metal centers in the same molecule can afford novel electronic structures and physical properties, including multiconfigurational electronic states and valence tautomerism. Further targeted exploration of these features is clearly warranted, both to enhance understanding of the underlying fundamental chemistry, and for the generation of a potentially important new class of molecular material.  相似文献   

3.

 In this article the role of reference materials is confined to chemical measurements only. Recognized reference materials are one of the tools to obtain comparability of analytical results. Recognition demands confidence in the reference materials and in the reference material producers. A reference material producer is a technical competent body that is fully responsible for the certified or other property values of the reference material. The "analyte" has to be specified in relation to the selectivity of analytical procedure. The full range of reference materials can be presented as a three-dimensional space of the coordinates: analyte, matrix and application. If reference materials are used for calibration or correction of calibrations they establish the traceability of results of chemical measurements. The traceability is only valid within a stated range of uncertainty. Pure substances can represent the unit of amount of substance. A precondition is the microscale specification of the analyte and the accurate determination of the main component and/or the impurities.

  相似文献   

4.
Abstract

The title complexes have been newly synthesized for the lanthanoid ions except for Ce and Pm. The effect of lanthanoid ions on the ligand field of copper(II) ion are discussed on the basis of electronic spectra.  相似文献   

5.
Three plasma-based ambient pressure ion sources were investigated; laboratory constructed dielectric barrier and rf glow discharges, as well as a commercial corona discharge (DART source). All were used to desorb and ionize a model analyte, providing sampling techniques for ambient mass spectrometry (MS). Experimental parameters were optimized to achive highest signal for acetaminophen as the analyte. Insight into the mechanisms of analyte desorption and ionization was obtained by means of emission spectrometry and ion current measurements. Desorption and ionization mechanisms for this analyte appear to be identical for all three plasma sources. Emission spectra differ only in the intensities of various lines and bands. Desorption of solid analyte requires transfer of thermal energy from the plasma source to sample surface, in the absence of which complete loss of MS response occurs. For acetaminophen, helium was the best plasma gas, providing 100- to 1000-fold higher analyte response than with argon or nitrogen. The same trend was also evident with background ions (protonated water clusters). MS analyte signal intensity correlates with the ion density (expressed as ion current) in the plasma plume and with emission intensity from excited state species in the plasma. These observations support an ionization process which occurs via proton transfer from protonated water clusters to analyte molecules.  相似文献   

6.
We report a label-free optical detection technique, called total internal reflection ellipsometry (TIRE), which can be applied to study the interactions between biomolecules and a functionalized polymer surface. Zeonor (ZR), a cycloolefin polymer with low autofluorescence, high optical transmittance and excellent chemical resistance, is a highly suitable material for optical biosensor platforms owing to the ease of fabrication. It can also be modified with a range of reactive chemical groups for surface functionalization. We demonstrate the applications of TIRE in monitoring DNA hybridization assays and human chorionic gonadotrophin sandwich immunoassays on the ZR surface functionalized with carboxyl groups. The Ψ and Δ spectra obtained after the binding of each layer of analyte have been fitted to a four-layer ellipsometric model to quantitatively determine the amount of analytes bound specifically to the functionalized ZR surface. Our proposed TIRE technique with its very low analyte consumption and its microfluidic array format could be a useful tool for evaluating several crucial parameters in immunoassays, DNA interactions, adsorption of biomolecules to solid surfaces, or assessment of the reactivity of a functionalized polymer surface towards a specific analyte.  相似文献   

7.
In organic mass spectrometry, fragment ions provide important information on the analyte as a central part of its structure elucidation. With increasing molecular size and possible protonation sites, the potential energy surface (PES) of the analyte can become very complex, which results in a large number of possible fragmentation patterns. Quantum chemical (QC) calculations can help here, enabling the fast calculation of the PES and thus enhancing the mass spectrometry-based structure elucidation processes. In this work, the previously unknown fragmentation pathways of the two drug molecules Nateglinide (45 atoms) and Zopiclone (51 atoms) were investigated using a combination of generic formalisms and calculations conducted with the Quantum Chemical Mass Spectrometry (QCxMS) program. The computations of the de novo fragment spectra were conducted with the semi-empirical GFNn-xTB (n=1, 2) methods and compared against Orbitrap measured electrospray ionization (ESI) spectra in positive ion mode. It was found that the unbiased QC calculations are particularly suitable to predict non-evident fragment ion structures, sometimes contrasting the accepted generic formulation of fragment ion structures from electron migration rules, where the “true” ion fragment structures are approximated. For the first time, all fragment and intermediate structures of these large-sized molecules could be elucidated completely and routinely using this merger of methods, finding new undocumented mechanisms, that are not considered in common rules published so far. Given the importance of ESI for medicinal chemistry, pharmacokinetics, and metabolomics, this approach can significantly enhance the mass spectrometry-based structure elucidation processes and contribute to the understanding of previously unknown fragmentation pathways.  相似文献   

8.
We describe a new T‐Jump/time‐of‐flight (TOF) mass spectrometer for the time‐resolved analysis of rapid pyrolysis chemistry of solids and liquids, with a focus on energetic materials. The instrument employs a thin wire substrate which can be coated with the material of interest, and can be rapidly heated (105 K/s). The T‐Jump probe is inserted within the extraction region of a linear TOF mass spectrometer, which enables multiple spectra to be obtained during a single reaction event. By monitoring the electrical characteristics of the heated wire, the temperature could also be obtained and correlated to the mass spectra. As examples, we present time‐resolved spectra for the ignition of nitrocellulose and RDX. The fidelity of the instrument is demonstrated in the spectra presented which show the temporal formation and decay of several species in both systems. The simultaneous measurement of temperature enables us to extract the ignition temperature and the characteristic reaction time. The time‐resolved mass spectra obtained show that these solid energetic material reactions, under a rapid heating rate, can occur on a time scale of milliseconds or less. While the data sampling rate of 10 000 Hz was used in the present experiments, the instrument is capable of a maximum scanning rate of up to ~30 kHz. The capability of high‐speed time‐resolved measurements offers an additional analytical tool for the characterization of the decomposition, ignition, and combustion of energetic materials. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

9.
We introduce continuous‐flow field desorption (FD) for improved spectral quality, higher sample throughput, and simpler interface to sample handlers and chromatographic equipment. A recently developed commercial FD probe with integral fused‐silica capillary allows sample dosing in situ, without probe removal and reinsertion. A stable FD‐generated ion current can be sustained for longer than an hour by continuous deposition of analyte solution on the FD emitter heated and at high voltage. Continuous‐flow FD allows ensemble averaging of up to 100 Fourier transform ion cyclotron resonance (FT‐ICR) mass spectra, in contrast to the traditional emitter dosing technique. Continuous‐flow FD is amenable to interface with liquid chromatography (LC) and/or automated sample injectors. Copyright © 2004 John Wiley & Sons, Ltd.  相似文献   

10.
Compared with other transition metal Mxene derived quantum dots(MQDS),Ta-based Mxene quantum dots have good functionality,but Ta-based Mxene quantum dots and their applications have not been studied so far.In this paper,we report for the first time the synthesis of high fluorescence quantum yield(QY) N-doped Ta4 C3 quantum dots(N-MQDs) using Ta4 C3 quantum dots in acid reflux damaged Ta4 C3 nanosheets as precursors and ...  相似文献   

11.
In 2017, we introduced the OrbiSIMS instrument that features a dual analyser configuration with a time-of-flight (ToF) mass spectrometer (MS) and an Orbitrap MS, which confer advantages of speed and high-performance mass spectrometry, respectively. The ability to combine the MS performance usually found in a state-of-the-art proteomics and metabolomics MS with 3D imaging at the microscale and from nanolayers of <10 nm of material has proved popular in a broad field of application from organic electronics to drug discovery. There are now several instruments in operation around the world, and metrology is needed to help ensure repeatability and reproducibility of the intensity scale. We conduct a systematic study of two key parameters, the target potential, VT, and the collision cell pressure, P, in the transfer optics on the transmitted secondary ion intensities. We measure VTP maps of the ions across the mass range for Ag as a representative of inorganic materials and two different organic materials, Irganox 1010 and NPB (N,N′-Di[1-naphthyl]-N,N′-diphenyl-4,4′-biphenyldiamine). The manufacturer's defaults for these values ensure very good transmission for a broad range of analyte classes. However, the maps reveal a sometimes complex behaviour and indicate the possibility for additional separation of ions based on their shape, labile nature and kinetics of formation. Guidance is provided on how to optimise these parameters for sensitivity for different material classes and also the need for optimisation to improve spectral repeatability and reproducibility.  相似文献   

12.
Abstract

Lanthanoid complexes of a tetra-amide substituted calix[4]arene in the cone conformation are characterised by single crystal X-ray structure determination. The structural analysis shows that the metal ions are coordinated to the calixarene through the eight O donor atoms, along with one aqua ligand which is located within the cavity of the calixarene. The calixarene ligand was covalently incorporated into a polymethylmethacrylate monolith through p-allyl functional groups, followed by loading with a range of lanthanoid cations giving rise to light-emitting materials. The emission from the hydrid materials was found to be comparable to the solution phase emission.  相似文献   

13.
This review with 60 references describes a unique path to miniaturisation, that is, the use of acoustic levitation in analytical and bioanalytical chemistry applications. Levitation of small volumes of sample by means of a levitation technique can be used as a way to avoid solid walls around the sample, thus circumventing the main problem of miniaturisation, the unfavourable surface-to-volume ratio. Different techniques for sample levitation have been developed and improved. Of the levitation techniques described, acoustic or ultrasonic levitation fulfils all requirements for analytical chemistry applications. This technique has previously been used to study properties of molten materials and the equilibrium shape and stability of liquid drops. Temperature and mass transfer in levitated drops have also been described, as have crystallisation and microgravity applications.The airborne analytical system described here is equipped with different and exchangeable remote detection systems. The levitated drops are normally in the 100 nL–2 L volume range and additions to the levitated drop can be made in the pL-volume range.The use of levitated drops in analytical and bioanalytical chemistry offers several benefits. Several remote detection systems are compatible with acoustic levitation, including fluorescence imaging detection, right angle light scattering, Raman spectroscopy, and X-ray diffraction. Applications include liquid/liquid extractions, solvent exchange, analyte enrichment, single-cell analysis, cell–cell communication studies, precipitation screening of proteins to establish nucleation conditions, and crystallisation of proteins and pharmaceuticals.  相似文献   

14.
Liquid crystal elastomers (LCEs) are a unique class of materials which combine rubber elasticity with the orientational order of liquid crystals. This combination can lead to materials with unique properties such as thermal actuation, anisotropic swelling, and soft elasticity. As such, LCEs are a promising class of materials for applications requiring stimulus response. These unique features and the recent developments of the LCE chemistry and processing will be discussed in this review. First, we emphasize several different synthetic pathways in conjunction with the alignment techniques utilized to obtain monodomain LCEs. We then identify the synthesis and alignment techniques used to synthesis LCE‐based composites. Finally, we discuss how these materials are used as actuators and sensors. © 2017 Wiley Periodicals, Inc. J. Polym. Sci., Part B: Polym. Phys. 2017 , 55, 395–411  相似文献   

15.
A unique feature of the work carried out in the Collaborative Research Center 3MET continues to be its emphasis on innovative, advanced experimental methods which hyphenate mass-selection with further analytical tools such as laser spectroscopy for the study of isolated molecular ions. This allows to probe the intrinsic properties of the species of interest free of perturbing solvent or matrix effects. This review explains these methods and uses examples from past and ongoing 3MET studies of specific classes of multicenter metal complexes to illustrate how coordination chemistry can be advanced by applying them. As a corollary, we will show how the challenges involved in providing well-defined, for example monoisomeric, samples of the molecular ions have helped to further improve the methods themselves thus also making them applicable to many other areas of chemistry.  相似文献   

16.
Carbon‐based transition‐metal oxides are considered as an appropriate anode material candidate for lithium‐ion batteries. Herein, a simple and scalable dry production process is developed to produce carbon‐encapsulated 3D net‐like FeOx /C materials. The process is simply associated with the pyrolysis of a solid carbon source, such as filter paper, adsorbed with ferrite nitrate. The carbon derived from filter paper induces a carbothermal reduction to form metallic Fe, the addition of carbon and iron increase the conductivity of this material. As expected, this 3D net‐like FeOx /C composite delivers an excellent charge capacity of 851.3 mAh g−1 after 50 cycles at 0.2 A g−1 as well as high stability and rate performance of 714.7 mAh g−1 after 300 cycles at 1 A g−1. Superior performance, harmlessness, low costs, and high yield may greatly stimulate the practical application of the products as anode materials in lithium‐ion batteries.  相似文献   

17.
Determining the relative configuration or enantiomeric excess of a substance may be achieved using NMR spectroscopy by employing chiral shift reagents (CSRs). Such reagents interact noncovalently with the chiral solute, resulting in each chiral form experiencing different magnetic anisotropy; this is then reflected in their NMR spectra. The Keplerate polyoxometalate (POM) is a molybdenum-based, water-soluble, discrete inorganic structure with a pore-accessible inner cavity, decorated by differentiable ligands. Through ligand exchange from the self-assembled nanostructure, a set of chiral Keplerate host molecules has been synthesised. By exploiting the interactions of analyte molecules at the surface pores, the relative configuration of chiral amino alcohol guests (phenylalaninol and 2-amino-1-phenylethanol) in aqueous solvent was establish and their enantiomeric excess was determined by 1H NMR using shifts of ΔΔδ=0.06 ppm. The use of POMs as chiral shift reagents represents an application of a class that is yet to be well established and opens avenues into aqueous host-guest chemistry with self-assembled recognition agents.  相似文献   

18.
In this work the effect in secondary ion mass spectrometry (SIMS) of several frequently used matrix‐assisted laser desorption/ionisation (MALDI) matrices on the secondary ion intensities of low molecular weight (m/z 400–800) organic dyes and a pharmaceutical is tested. Matrix (10?1 M) and analyte (10?2 M) solutions were made in methanol. Mixtures with several concentration ratios were prepared from these solutions and spincoated on Si substrates prior to time‐of‐flight (TOF)‐SIMS analysis. In some cases the presence of the MALDI matrices caused a considerable increase in the positive secondary (protonated) molecular ion signals. Enhancements of a factor of 20 and more were recorded. Generally, of the matrices used, 2,5‐dihydroxybenzoic acid and 2,4,6‐trihydroxyacetophenone brought about the highest intensity increases. It was also shown that matrix‐enhanced (ME‐)SIMS is capable of lowering the detection limits for molecule ions. However, the enhancement effect is strongly influenced by the analyte/matrix combination and its concentration ratio. As a result, finding an optimal analyte/matrix mixture can be a very time‐consuming process. Mostly, the presence of the matrices causes changes in the relative ion intensities in the TOF‐S‐SIMS spectra. Compared to the spectra recorded from samples without matrices, only a few additional peaks, such as signals that originate directly from the applied matrix or adduct ions, are observed in the mass spectra. Sometimes molecule ions and some characteristic fragments at high m/z values, that cannot be recorded without matrix, do appear in the spectrum when a matrix is present. In the negative mode no enhancement effect is observed on applying the studied MALDI matrices. The results obtained from samples treated with MALDI matrices are also compared to SIMS results for the same samples after Ag and Au metallisation (MetA‐SIMS). For three of the four tested compounds Au MetA‐SIMS resulted in higher ion yields than ME‐SIMS. For both techniques possible mechanisms that can account for the enhancement effect are proposed. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

19.
20.
It has been proven qualitatively by a number of authors using variable temperature NMR experiments that most metal carbonyl complexes are nonrigid. A quantitative determination of the ligand exchange frequency ve is often achieved by a line shape analysis or by measurement of the transverse relaxation time T2 using the Carr-Purcell method. In the case of a “very fast” exchange, however, both methods prove unsuccessful. It is shown in this study that a simultaneous fit of IR or Raman spectra on the one hand and NMR spectra on the other can make possible the determination of ve for the “very fast” exchange and can also facilitate the determination of ve in “slow” and “medium” exchange cases considerably. The ligand exchange frequency thus found for Fe(CO)5, 1.1 × 1010s?1, is unexpectedly high; comparison with variable temperature measurements on solid Fe(CO)5, yields similar energy barriers. A mechanism of exchange closely related to the “Berry mechanism” is proposed. Finally the consequences of this surprisingly large ligand exchange rate are discussed with respect to IR band assignments for molecular “fragments” M(CO)x (where x=coordination number, and M is a transition metal, typically lanthanoid or actinoid).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号