首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 453 毫秒
1.
A glassy carbon electrode was modified with carbon nanotubes and the ionic liquid N‐butyl pyridinium trifluoromethyl methanesulfonate for the determination of methyldopa in urine samples. Methyldopa exhibited a well‐defined anodic signal over a broad pH range of 2–10 and the peak current increased approximately 100 fold over that of the unmodified electrode. Accordingly, a novel method for the determination of methyldopa was proposed using differential pulse voltammetry. The peak current was linear over a methyldopa concentration range from 21 to 2111 ng mL?1 with a LOD of 6.9 ng mL?1 and a LOQ of 7.4 ng mL?1. The method was applied to determine the excretion profile of methyldopa in urine without sample pretreatment.  相似文献   

2.
Electrochemical behavior of remarkably low levels of Ribonucleic acid yeast (yRNA) is studied through differential pulse voltammetry (DPV), and kinetic parameters of the electrochemical reaction have also been calculated through square‐wave voltammetry (SWV), based on immobilization of yRNA on the surface of a CPB‐cellulose modified electrode. YRNA/ CPB‐cellulose/ITO conductive glass electrode is demonstrated by Infrared reflect (IR) and electrochemical impedance spectroscopy (EIS). The oxidation peak potential of yRNA shifts negatively with increasing pH. The peak currents decrease gradually in successive scans and no corresponding reduction peaks occur, indicating that oxidation process of yRNA is completely irreversible. Variables influencing DPV response of yRNA, such as pH, pulse amplitude and electrolyte concentration, are explored and optimized. Peak currents are proportional to the concentration of yRNA in the range of 0.1 μg mL?1–1.0 μg mL?1, and the linear regression coefficient equals 0.9923. The detection limit for yRNA is 1.0×10?10 g mL?1. Interferences of L ‐cysteine, L ‐alanine, Hemoglobin, Uridine 5′‐monophosphate, Guanosine 5′‐monophosphate, Adenosine 5′‐triphosphate and some metal ions (Co3+, Cr3+, Ni2+, Hg2+, Zn2+, etc) are negligible. The methods adopted here are more sensitive and selective than currently applied techniques and overcome the drawback of absorption spectroscopy arising from a strong interference due to other UV‐absorbing substances.  相似文献   

3.
We report that magnetic multiwalled carbon nanotubes functionalized with 8-aminoquinoline can be applied to the preconcentration of Cd(II), Pb(II) and Ni(II) ions. The parameters affecting preconcentration were optimized by a Box-Behnken design through response surface methodology. Three variables (extraction time, magnetic sorbent amount, and pH value) were selected as the main factors affecting sorption, and four variables (type, volume and concentration of the eluent; elution time) were selected for optimizing elution. Following sorption and elution, the ions were quantified by FAAS. The LODs are 0.09, 0.72, and 1.0 ng mL?1 for Cd(II), Ni(II), and Pb(II) ions, respectively. The relative standard deviations are <5.1 % for five separate batch determinations at 30 ng mL?1 level of Cd(II), Ni(II), and Pb(II) ions. The sorption capacities (in mg g?1) of this new sorbent are 201 for Cd(II), 150 for Pb(II), and 172 Ni(II). The composite was successfully applied to the rapid extraction of trace quantities of heavy metal ions in fish, sediment, soil, and water samples.
Figure
A schematic diagram for synthesis of functionalized magnetic multiwalled carbon nanotube.  相似文献   

4.
We describe a new method for the separation and preconcentration of traces of Au(III) in environmental samples. Sorbents made from modified multiwalled carbon nanotubes and conducting polymers (PANI and PEDOT) were used for solid-phase extraction. The Au(III) ions are adsorbed as a result of the interaction with the electron pairs of =N- and -S- groups. Effects of pH value, flow rate and volume of sample, type, volume and concentration of eluent, and the adsorption capacity were investigated. The maximum adsorption capacity of MWCNTs/PANI and MWCNTs/PEDOT are 159 and 176?mg?g?1, and the detection limits of this method are below 0.3 and 0.5?ng?mL?1, respectively. The procedure was successfully applied to the determination of traces of Au(III) in a reference material and in environmental samples.
Figure
The multiwalled carbon nanotubes/conducting polymers (PANI and PEDOT) were used for solid-phase extraction of Au(III) ions. The Au(III) adsorbed on macromolecules chains; resulting from sharing an electron pair of = N?C and ?CS?C groups of conducting polymers with gold ions. The final results demonstrate that nanocomposites are convenient for preconcentration and determination of gold from environmental samples.  相似文献   

5.
In this work, the potential of modified multiwalled carbon nanotubes for separation and preconcentration of trace amounts of manganese ion is studied. Multiwalled carbon nanotubes were oxidized with concentrated HNO3 and then modified with loading 1-(2-pyridylazo)-2-naphtol. Mn(II) ions could be quantitatively retained by modified multiwalled carbon nanotubes in the pH range of 8–9.5. Elution of the adsorbed manganese was carried out with 5.0 mL of 0.1 mol L?1 HNO3. Detection limit is 0.058 ng mL?1 and analytical curve is linear in the range of 0.1 ng mL?1–5.0 μg mL?1 in the initial solution with a correlation coefficient 0.9977 and the preconcentration factor is 100. Relative standard deviation for eight replicate determination of 0.5 μg mL?1 of manganese in the final solution is 0.41%. The effects of the experimental parameters, including the sample pH, flow rates of sample and eluent solution, eluent type, breakthrough volume and interference ions, were studied for preconcentration of Mn(II) ions in detail to optimize the conditions. The method was successfully applied for separation, preconcentration and determination of manganese in different samples.  相似文献   

6.
We report an innovative supramolecular architecture for bienzymatic glucose biosensing based on the non‐covalently functionalization of multi‐walled carbon nanotubes (MWCNTs) with two proteins, glucose oxidase (GOx) (to recognize glucose) and avidin (to allow the specific anchoring of biotinylated horseradish peroxidase (b‐HRP)). The optimum functionalization was obtained by sonicating for 10 min 0.50 mg mL?1 MWCNTs in a solution of 2.00 mg mL?1 GOx+1.00 mg mL?1avidin prepared in 50 : 50 v/v ethanol/water. The sensitivity to glucose for glassy carbon electrodes (GCE) modified with MWCNTs‐GOx‐avidin dispersion and b‐HRP (GCE/MWCNTs‐GOx‐avidin/b‐HRP), obtained from amperometric experiments performed at ?0.100 V in the presence of 5.0×10?4 M hydroquinone, was (4.8±0.3) μA mM?1 (r2=0.9986) and the detection limit was 1.2 μM. The reproducibility for 5 electrodes using the same MWCNTs/GOx‐avidin dispersion was 4.0 %, while the reproducibility for 3 different dispersions and 9 electrodes was 6.0 %. The GCE/MWCNT‐GOx‐avidin/b‐HRP was successfully used for the quantification of glucose in a pharmaceutical product and milk.  相似文献   

7.
Multi-walled carbon nanotubes (MWCNTs) were chemically functionalized by glutaric dihydrazide (GDH) and characterized with FT-IR technique. This new sorbent was used for enrichment and preconcentration of Co(II), Cd(II), Pb(II), and Pd(II) ions. The adsorption was achieved quantitatively on MWCNTs at pH 4.0, and then the retained metal ions on the adsorbent were eluted with 1.5 mol L?1 HNO3. The effects of analytical parameters including pH of the solution, eluent type, sample volume, and matrix ions were investigated for optimization of the presented procedure. The adsorption capacity of the adsorbent at optimum conditions was found to be 33.6, 29.2, 22.1, and 36.0 mg g?1 for Co(II), Cd(II), Pb(II), and Pd(II), respectively. The LOD values of the method were 0.16, 0.19, 0.17, and 0.12 ng mL?1 (3Sb, n = 10) for Co(II), Cd(II), Pb(II), and Pd(II), respectively. The RSDs values of the method were 0.75, 0.85, 1.16, and 1.30 ng mL?1 for Co(II), Cd(II), Pb(II), and Pd(II), respectively. The method was applied for the determination of analytes in soil, well water, and wastewater samples with satisfactory results.  相似文献   

8.
A method for preconcentration of palladium at trace level on modified multiwalled carbon nanotubes columns and determination by flame atomic absorption spectrometry (FAAS) has been developed. Multiwalled carbon nanotubes (MWCNTs) were oxidized with concentrated HNO3 and the oxidized multiwalled carbon nanotubes were modified with 5-(4′-dimethylamino benzyliden)-rhodanine, and then were used as a solid sorbent for preconcentration of Pd(II) ions. Factors influencing sorption and desorption of Pd(II) ions were investigated. The sorption of Pd(II) ions was quantitative in the pH range of 1.0–4.5, whereas quantitative desorption occurs with 3.0 mL 0.4 mol L?1 thiourea. The amount of eluted palladium was measured using flame atomic absorption spectrometry. The effects of experimental parameters, including sample flow rate, eluent flow rate, and eluent concentration were investigated. The effect of coexisting ions showed no interference from most ions tested. The proposed method permitted a large enrichment factor (about 200). The relative standard deviation of the method was ±2.73% (for eight replicate determination of 2.0 μg mL?1 of Pd(II)) and the limit of detection was 0.3 ng mL?1. The method was applied to the determination of Pd(II) in water, road dust, and standard samples.  相似文献   

9.
Genomic DNA in bacteria exists in a condensed state, which exhibits different biochemical and biophysical properties from a dilute solution. DNA was concentrated on streptavidin‐covered single‐walled carbon nanotubes (Strep ? SWNTs) through biotin–streptavidin interactions. We reasoned that confining DNA within a defined space through mechanical constraints, rather than by manipulating buffer conditions, would more closely resemble physiological conditions. By ensuring a high streptavidin loading on SWNTs of about 1 streptavidin tetramer per 4 nm of SWNT, we were able to achieve dense DNA binding. DNA is bound to Strep ? SWNTs at a tunable density and up to as high as 0.5 mg mL?1 in solution and 29 mg mL?1 on a 2D surface. This platform allows us to observe the aggregation behavior of DNA at high concentrations and the counteracting effects of HU protein (a histone‐like protein from Escherichia coli strain U93) on the DNA aggregates. This provides an in vitro model for studying DNA–DNA and DNA–protein interactions at a high DNA concentration.  相似文献   

10.
《Electroanalysis》2005,17(8):719-723
A very sensitive and selective adsorptive cathodic stripping procedure for trace measurement of uranium is presented. The method is based on adsorptive accumulation of the uranium‐pyromellitic acid (benzene‐1,2,4,5‐tetracarboxylic acid) complex onto a hanging mercury drop electrode, followed by reduction of the adsorbed species by voltammetric scan using differential pulse modulation. Influences of effective parameters such as pH, concentration of pyromellitic acid, accumulation potential and accumulation time on the sensitivity were studied. The peak current was proportional to the concentration of U(IV) up to 40 ng mL?1 with a limit of detection of 0.136 ng mL?1 with an accumulation time of 120 s. The range of linearity enhanced to 71.4 ng mL?1and the detection limit improved to 0.058 ng mL?1with accumulation times of 60 s and 300 s respectively. The relative standard deviation for 10 replicate determination of 4.76 ng mL?1 U(IV) was equal to 2.7%. The possible interference by major cations and anions are investigated. The method was applied to the determination of uranium in some analytical grade salts, seawater and in synthetic samples corresponding to some uranium alloys with satisfactory results.  相似文献   

11.
Direct delivery of protein suffers from their in vitro and in vivo instability, immunogenicity, and a relatively short half‐life within the body. To overcome these challenges, pH and glucose dual‐responsive biodegradable nanogels comprised of dextran and poly(L‐glutamic acid)‐g‐methoxy poly‐(ethylene glycol)/phenyl boronic acid (PLG‐g‐mPEG/PBA) are designed. The cross‐linked network imparted drug‐loading efficacy of α‐amylase up to 55.6% and hyaluronidase up to 29.1%. In vitro protein release profiles reveal that the release of protein is highly dependent on the pH or glucose concentrations, that is, less amount of protein is released at pH 7.4 or healthy blood glucose level (1 mg mL?1 glucose), while quicker release of protein occurs at pH 5.5 or diabetic blood glucose level (above 3 mg mL?1 glucose). Circular dichroism spectra show that the secondary structure of released protein is maintained compared to naive protein. Overall, the nanogels have provided a simple and effective strategy to deliver protein.  相似文献   

12.
A second‐derivative spectrophotometric method based on zero‐crossing over technique is developed in simultaneous determination of copper(II) and nickel(II) ions. Methylthymol blue (MTB) as a chromogenic reagent and cetyltrimethylammonium bromide as a surfactant were used, and measurements were carried out in buffered solution at pH 6 and at a temperature of 25 °C. The amplitude of derivative spectra was measured at wavelengths of 631.9 and 587.7 nm for the simultaneous determination of Ni2+ and Cu2+, respectively. Linearity was obtained in the range of 0.5–5.0 μg mL?1 for both ions in the presence of 0.0–5.0 μg mL?1 of the other ion as an interfering ion. IUPAC detection limits for Cu2+ and Ni2+ ions were obtained at 0.48 and 0.43 μg mL?1, respectively. The proposed procedure has been applied successfully for the simultaneous determination of copper and nickel in synthetic binary mixtures and real samples.  相似文献   

13.
The interaction between anionic surfactants (AS) and 1‐hexadecyl‐3‐methylimidazolium bromide [C16mim]Br was studied by using resonance light scattering (RLS) technique, UV‐Vis spectrophotometry and fluorometric methods. In Britton Robinson (BR) buffer (pH 6.0), [C16mim]Br reacted with AS to form supermolecular complex which resulted in enhancement in RLS intensity. Their maximum RLS wavelengths were all at 390 nm. Some important interacting experimental variables, such as the solution acidity, [C16mim]Br concentration, salt effect and addition order of the reagents, were investigated and optimized. Under the optimum conditions, quantitative determination ranges were 0.001–7 μg·mL?1 for dodecyl sodium sulfate (SDS), 0.001–6 μg·mL?1 for sodium dodecylbenzene sulfonate (SDBS) and 0.005–7 μg·mL?1 for sodium lauryl sulfonate (SLS), respectively, while the detection limits were 1.3 ng·mL?1 for SDS, 1.0 ng·mL?1 for SDBS and 5.1 ng·mL?1 for SLS, respectively. Based on the ion‐association reaction, a highly sensitive, simple and rapid method has been established for the determination of AS.  相似文献   

14.
A solid‐phase extraction method for preconcentration of silver and consequent determination by atomic absorption spectrometry is described. The method is based on the adsorption of silver on naphthalene modified with dithizone in a column. The adsorbed silver is eluted from the column with a thiourea solution and determined by flame atomic absorption spectrometry. The adsorption conditions including pH, reagent concentration, eluent volume, flow rate and interfering ions were investigated. The calibration graph was linear in the range 10–1000 ng mL?1 of Ag in the initial solution with r = 0.9998. The limit of detection based on 3Sb was 3.9 ng mL?1. The relative standard deviation for ten replicate measurements of 40 and 600 ng mL?1 of Ag was 4.4% and 0.9%, respectively. The method was applied to the determination of silver in mineral, radiology film and wound dressing samples.  相似文献   

15.
An electrochemical sensor of glassy carbon electrode modified with reduced graphene oxide and manganese (II) phthalocyanine (GCE/rGO/MnPc) was developed as an effective alternative in the determination of imidacloprid in honey samples. The peak current variation obtained with the proposed sensor, in the presence of imidacloprid, was higher compared to the bare GCE. The followed experimental conditions were optimized: reduced graphene oxide concentration (2.0 mg mL?1), manganese (II) phthalocyanine concentration (1.5 mg mL?1), electrolyte pH (6.5) and electrolyte concentration (1,50 mol L?1). The study also showed that the process of reduction of imidacloprid is irreversible and diffusion‐controlled, with a single reduction peak of approximately ?0.9 V corresponding to the reduction of the nitro group (?NO2) present in the structure, generating a derived from hydroxylamine, in a process involving about four electrons. The determination of imidacloprid in honey samples exhibited recovery values within the EPA range (between 90.5 and 101.9 %). The proposed sensor GCE/rGO/MnPc can be used as an effective alternative in the determination of imidacloprid in honey samples.  相似文献   

16.
Bimetallic tubular nanostructures have been the focus of intensive research as they have very interesting potential applications in various fields including catalysis and electronics. In this paper, we demonstrate a facile method for the fabrication of Au–Pt double‐walled nanotubes (Au–Pt DWNTs). The DWNTs are fabricated through the galvanic displacement reaction between Ag nanowires and various metal ions, and the Au–Pt DWNT catalysts exhibit high active catalytic performances toward both methanol electro‐oxidation and 4‐nitrophenol (4‐NP) reduction. First, they have a high electrochemically active surface area of 61.66 m2 g?1, which is close to the value of commercial Pt/C catalysts (64.76 m2 g?1), and the peak current density of Au–Pt DWNTs in methanol oxidation is recorded as 138.25 mA mg?1, whereas those of Pt nanotubes, Au/Pt nanotubes (simple mixture), and commercial Pt/C are 24.12, 40.95, and120.65 mA mg?1, respectively. The Au–Pt DWNTs show a markedly enhanced electrocatalytic activity for methanol oxidation compared with the other three catalysts. They also show an excellent catalytic performance in comparison with common Au nanotubes for 4‐nitrophenol (4‐NP) reduction. The attractive performance exhibited by these prepared Au–Pt DWNTs can be attributed to their unique structures, which make them promising candidates as high‐performance catalysts.  相似文献   

17.
《Electroanalysis》2005,17(22):2032-2036
We found that bis(thiophenal) pyridine‐2,6‐diamine (BPD) can be used as an excellent ion carrier to prepare a gadolinium‐selective PVC‐based membrane sensor. The use of oleic acid (OA) and potassium tetrakis(p‐chlorophenyl borate)(KTKpClPB), as anionic additives, and dibutyl phthalate (DBP), acetophenone (AP) and nitrobenzene (NB), as plasticizing solvent mediators was investigated. The best performance was observed with a membrane having the composition of 30% PVC; 62% BA; 5% BPD; and 3% KTKpClPB. The resulting sensor works well over a relatively wide concentration range (1.0×10?6–1.0×10?1 M) with a Nernstian slope of 19.4±0.4 mV per decade of gadolinium activity over a wide pH range (3.5–8.0). The limit of detection of the sensor is 7.0×10?7 M (ca. 110 ng mL?1). The proposed electrode shows excellent discriminating ability toward gadolinium ions with regard to common alkali, alkaline earth, transition, heavy metal ions, and specially, lanthanide ions. The proposed sensor was applied as an indicator electrode for titration of gadolinium ions with EDTA.  相似文献   

18.
《Analytical letters》2012,45(7):1333-1347
Abstract

A multianalyte flow‐through sensor is proposed for the simultaneous determination of aspartame (AS) and acesulfame‐K (AK) in tabletop sweeteners. The procedure is based on the transient retention of AK in the ion exchanger Sephadex DEAE A‐25 placed in the flow‐through cell of a monochannel flow injection analysis (FIA) set‐up using pH 2.70 ortophosphoric acid/sodium dihydrogen phosphate buffer 0.06 M as carrier. In these conditions AS is very weakly retained, which makes it possible to measure the intrinsic ultraviolet (UV) absorbance of first AS and then AK after desorption by the carrier itself. The applicable concentration range, the detection limit, and the relative standard deviation were the following: for AS, from 10 to 100 µg mL?1; 5.65 µg mL?1; 3.4% (at 50 µg mL?1); and for AK, between 40 and 100 µg mL?1; 11.9 µg mL?1 and 1.61% (at 50 µg mL?1). The method was applied and validated satisfactorily for the determination of AS and AK blends in tabletop sweeteners. The results were compared against an HPLC reference method.  相似文献   

19.
In this flow-injection method, the total concentration of calcium and magnesium is determined by using triethanolamine/hydrochloric acid buffer (pH 7.0) and chlorphosphonazo-III (CPA-III) in the flow streams, and the concentration of calcium alone is determined by using 1.6×10?3 M hydrochloric acid and CPA-III in the flow treams. At pH 7.0, medium, the linear calibration ranges were 0–2.00 mg l?1 for both calcium and magnesium and the detection limits were each 0.02 mg l?1; at pH 2.2, the linear calibration range for calcium and the detection limit were 0.20–2.00 mg l?1 and 0.1 mg l?1, respectively. Injection rates are 200 h. The method is suitable for analyzing natural waters.  相似文献   

20.
A magnetic composite of silver/iron oxides/carbon nanotubes (Ag/Fe3O4/CNTs) was synthesized and used as an adsorbent for the preconcentration of mercury ions in water solutions at room temperature (25°C) in this study. The silver nanoparticles were supported on the magnetic CNTs. The modification enabled the composite had not only a high adsorption capacity for mercury ions (Hg2+) but also the magnetic isolation properties. A fast, sensitive, and simple method was successfully developed for the preconcentration and determination of trace amount of Hg2+ in water using the synthesized nanocomposite as adsorbent. The mercury concentration was determined by an atomic fluorescence spectrometer (AFS). The experimental conditions such as pH value, extraction temperature, extraction time, sample volume, eluent composition and concentration, sorbent amount, and coexisting ions were investigated for the optimization. A 500 mL of sample volume resulted in a preconcentration factor of 125. When a 200 mL of sample was employed, the limit of detection for Hg2+ was as low as 0.03 ng mL?1with relative standard deviation of 4.4% at 0.1 ng mL?1 (n = 7). The ease of synthesis and separation, the good adsorption capacity, and the satisfactory recovery will possibly make the composite an attractive adsorbent for the preconcentration of ultratrace Hg2+ in waters.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号