首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
《Electroanalysis》2005,17(8):685-693
Carbon paste electrodes were modified by mixing appropriate amounts of the monomers o‐phenylendiamine, p‐phenylendiamine and m‐phenylendiamine (o‐PD, p‐PD and m‐PD) into a graphite powder‐paraffin oil matrix. The electropolymerization of the incorporated phenylendiamine was then carried out in a carbon paste electrode in acidic medium by cyclic voltammetry between ?0.30 V and +0.90 or under constant potential. The modified carbon paste electrodes (MCPEs) obtained by this electropolymerization method were found to be useful for trace determination of Pb2+ in aqueous solutions. Lead(II) was first preconcentrated on the modified electrodes by complexation with the modifier, and the electrode was then transferred to an electrochemical cell. The best results in terms of sensitivity and detection limit were obtained with poly p‐phenylenediamine (poly (p‐PD)). For a 10‐min preconcentration time, the calibration plot was linear from 5×10?8 mol L?1 to 10?5 mol L?1, with r2=0.999 and relative standard deviation equal to 5%. However, the lowest lead concentration that could be detected was 10?9 mol L?1. Interference from metal ions like Cd(II), Hg(II), Zn(II), Fe(II) and Cu(II) was also studied.  相似文献   

2.
Amperometric lactate biosensor based on a carbon paste electrode modified with benzo[c]cinnoline and multiwalled carbon nanotubes is reported. Incorporation of benzo[c]cinnoline acting as a mediator and multiwalled carbon nanotubes providing a conduction pathway to accelerate electron transfer due to their excellent conductivity into carbon paste matrix resulted in a high performance lactate biosensor. The resulting biosensor exhibited a fast response, high selectivity, good repeatability and storage stability. Under the optimal conditions, the enzyme electrode showed the detection limit of 7.0×10?8 M with a linear range of 2.0×10?7 M–1.1×10?4 M. The usefulness of the biosensor was demonstrated in serum samples.  相似文献   

3.
《Electroanalysis》2006,18(17):1722-1726
The electrochemical properties of L ‐cysteic acid studied at the surface of p‐bromanil (tetrabromo‐p‐benzoquinone) modified carbon paste electrode (BMCPE) in aqueous media by cyclic voltammetry (CV) and double step potential chronoamperometry. It has been found that under optimum condition (pH 7.00) in cyclic voltammetry, the oxidation of L ‐cysteic acid at the surface of BMCPE occurs at a half‐wave potential of p‐bromanil redox system (e.g., 100 mV vs. Ag|AgCl|KClsat), whereas, L ‐cysteic acid was electroinactive in the testing potential ranges at the surface of bare carbon paste electrode. The apparent diffusion coefficient of spiked p‐bromanil in paraffin oil was also determined by using the Cottrell equation. The electrocatalytic oxidation peak current of L ‐cysteic acid exhibits a linear dependency to its concentration in the ranges of 8.00×10?6 M–6.00×10?3 M and 5.2×10?7 M–1.0×10?5 M using CV and differential pulse voltammetry (DPV) methods, respectively. The detection limits (2σ) were determined as 5.00×10?6 M and 4.00×10?7 M by CV and DPV methods. This method was used as a new, selective, rapid, simple, precise and suitable voltammetric method for determination of L ‐cysteic acid in serum of patient's blood with migraine disease.  相似文献   

4.
《Electroanalysis》2005,17(1):89-96
Iron‐phthalocyanines (FePc) are functionalized at multi‐walled carbon nanotubes (MWNTs) to remarkably improve the sensitivity toward hydrogen peroxide. We constructed a highly sensitive and selective glucose sensor on FePc‐MWNTs electrode based on the immobilization of glucose oxidase (GOD) on poly‐o‐aminophenol (POAP)‐electropolymerized electrode surface. SEM images indicate that GOD enzymes trapped in POAP film tend to deposit primarily on the curved tips and evenly disperse along the sidewalls. The resulting GOD@POAP/FePc‐MWNTs biosensor exhibits excellent performance for glucose with a rapid response (less than 8 s), a wide linear range (up to 4.0×10?3 M), low detection limits (2.0×10?7 M with a signal‐to‐noise of 3), a highly reproducible response (RSD of 2.6%), and long‐term stability (120 days). Such characteristics may be attributed to the catalytic activity of FePc and carbon nanotube, permselectivity of POAP film, as well as the large surface area of carbon nanotube materials.  相似文献   

5.
The electrocatalytic reduction of nitrite has been studied by poly(ortho‐toluidine) films modified carbon paste electrode (P‐OT/MCPE). Cyclic voltammetry and chronoamperometry techniques were used to investigate the suitability of poly(ortho‐toluidine) as a mediator for the electrocatalytic nitrite reduction in aqueous solution with various pH. Results showed that pH 0.00 is the most suitable for this purpose. In the optimum pH, the reduction of nitrite occurs at a potential about 600 mV more positive than unmodified carbon paste electrode. The catalytic reaction rate constant, (kh), was calculated 8.68×102 M?1 s?1 by the data of chronoamperometry. The catalytic reduction peak current was linearly dependent on the nitrite concentration and the linearity range obtained was 5.00×10?4 M–1.90×10?2 M. Detection limit has been found to be 3.38×10?4 M (2σ). This method has been successfully employed for quantification of nitrite in real sample.  相似文献   

6.
A carbon paste electrode spiked with 1‐[4‐ferrocenyl ethynyl) phenyl]‐1‐ethanone (4FEPE) was constructed by incorporation of 4FEPE in graphite powder‐paraffin oil matrix. It has been shown by direct current cyclic voltammetry and double step chronoamperometry that this electrode can catalyze the oxidation of tryptophan (Trp) in aqueous buffered solution. It has been found that under optimum condition (pH 7.00), the oxidation of Trp at the surface of such an electrode occurs at a potential about 200 mV less positive than at an unmodified carbon paste electrode. The kinetic parameters such as electron transfer coefficient, α and rate constant for the chemical reaction between Trp and redox sites in 4FEPE modified carbon paste electrode (4FEPEMCPE) were also determined using electrochemical approaches. The electrocatalytic oxidation peak current of Trp showed a linear dependent on the Trp concentrations and linear calibration curves were obtained in the ranges of 6.00×10?6 M–3.35×10?3 M and 8.50×10?7 M–6.34×10?5 M of Trp concentration with cyclic voltammetry (CV) and differential pulse voltammetry (DPV) methods, respectively. The detection limits (3σ) were determined as 1.80×10?6 M and 5.60×10?7 M by CV and DPV methods. This method was also examined as a selective, simple and precise new method for voltammetric determination of tryptophan in real sample.  相似文献   

7.
Functionalized poly‐N,N‐dimethylaniline film was prepared by adsorption of ferrocyanide onto the polymer forming at the surface of carbon paste electrode (CPE) in aqueous solution by using potentiostatic method. The electrocatalytic ability of poly‐N,N‐dimethylaniline/ferrocyanide film modified carbon paste electrode (PDMA/FMCPE) was demonstrated by oxidation of cysteamine. Cyclic voltammetry and chronoamperometry techniques were used to investigate this ability. Results showed that pH 7.00 is the most suitable for this purpose. It is found that the catalytic reaction rate constant, (kh), is equal to 2.142×103 M?1 s?1 by the data of chronoamperometry. The catalytic reduction peak current was linearly dependent on the cysteamine concentration and the linearity range obtained was 8.00×10?5 M–1.14×10?2 M. Detection limit was determined 7.97×10?5 M (2σ). This method has been successfully employed for quantification of cysteamine in real sample.  相似文献   

8.
唐明宇袁若  柴雅琴 《中国化学》2006,24(11):1575-1580
The third generation amperometric biosensor for the determination of hydrogen peroxide (H2O2) has been described. For the fabrication of biosensor, o-aminobenzoic acid (oABA) was first electropolymerized on the surface of platinum (Pt) electrode as an electrostatic repulsion layer to reject interferences. Horseradish peroxidase (HRP) absorbed by nano-scaled particulate gold (nano-Au) was immobilized on the electrode modified with polymerized o-aminobenzoic acid (poABA) with L-cysteine as a linker to prepare a biosensor for the detection of H2O2. Amperometric detection of H2O2 was realized at a potential of +20 mV versus SCE. The resulting biosensor exhibited fast response, excellent reproducibility and sensibility, expanded linear range and low interferences. Temperature and pH dependence and stability of the sensor were investigated. The optimal sensor gave a linear response in the range of 2.99×10^-6 to 3.55×10^-3 mol·L^-1 to H2O2 with a sensibility of 0.0177 A·L^-1·mol^-1 and a detection limit (S/N = 3) of 4.3×10^-7 mol·L^-1. The biosensor demonstrated a 95% response within less than 10 s.  相似文献   

9.
A sensitive hydrogen peroxide (H2O2) biosensor was developed based on a reduced graphene oxide|carbon ceramic electrode (RGO|CCE) modified with cadmium sulfide‐hemoglobin (CdS‐Hb). The electron transfer kinetics of Hb were promoted due to the synergetic function of RGO and CdS nanoparticles. The transfer coefficient (α) and the heterogeneous electron transfer rate constant (ks) were calculated to be 0.54 and 2.6 s?1, respectively, indicating a great facilitation achieved in the electron transfer between Hb and the electrode surface. The biosensor showed a good linear response to the reduction of H2O2 over the concentration range of 2–240 µM with a detection limit of 0.24 µM (S/N=3) and a sensitivity of 1.056 µA µM?1 cm?2. The high surface coverage of the CdS‐Hb modified RGO|CCE (1.04×10?8 mol cm?2) and a smaller value of the apparent Michaelis? Menten constant (0.24 mM) confirmed excellent loading of Hb and high affinity of the biosensor for hydrogen peroxide.  相似文献   

10.
The electrochemical properties of hydrazine studied at the surface of a carbon paste electrode spiked with p‐bromanil (tetrabromo‐p‐benzoquinone) using cyclic voltammetry (CV), double potential‐step chronoamperometry and differential pulse voltammetry (DPV) in aqueous media. The results show this quinone derivative modified carbon paste electrode, can catalyze the hydrazine oxidation in an aqueous buffered solution. It has been found that under the optimum conditions (pH 10.00), the oxidation of hydrazine at the surface of this carbon paste modified electrode occurs at a potential of about 550 mV less positive than that of a bar carbon paste electrode. The electrocatalytic oxidation peak current of hydrazine showed a linear dependent on the hydrazine concentrations and linear analytical curves were obtained in the ranges of 6.00×10?5 M–8.00×10?3 M and 7.00×10?6 M–8.00×10?4 M of hydrazine concentration with CV and differential pulse voltammetry (DPV) methods, respectively. The detection limits (3σ) were determined as 3.6×10?5 M and 5.2×10?6 M by CV and DPV methods. This method was also used for the determination of hydrazine in the real sample (waste water of the Mazandaran wood and paper factory) by standard addition method.  相似文献   

11.
A new analytical methodology for the electrochemical detection of the herbicide maleic hydrazide (3,6‐dihydroxypyridazine) by flow injection analysis is presented. This method is supported by the novel application of a palladium‐dispersed carbon paste electrode as an amperometric sensor for this herbicide. Maleic hydrazide shows anodic electrochemical activity on carbon‐based electrodes (glassy carbon or carbon paste electrodes) in all the pH range. This electrochemical activity is enhanced using metal‐dispersed carbon paste electrodes, especially at Pd‐dispersed CPE which displays good oxidation signals at 690 mV (0.050 M phosphate buffer pH 7.0), 140 mV lower than at unmodified electrodes. Under the optimized conditions, the electroanalytical performance of Pd‐dispersed CPE in flow injection analysis was excellent, with good reproducibility (RSD 3.3%) and a wide linear range (1.9×10?7 to 1.0×10?4 mol L?1). A detection limit of 1.4×10?8 mol L?1 (0.14 ng maleic hydrazide) was obtained for a sample loop of 100 μL at a fixed potential of 700 mV in 0.050 M phosphate buffer solution at pH 7.0 and a flow rate of 2.0 mL min?1. The proposed method was applied for the maleic hydrazide detection in natural drinking water samples.  相似文献   

12.
An effective, stable enzymatic glucose biosensor was fabricated on a glassy carbon electrode (GCE) surface using simple multicomposite materials (MCM): a solution of prepared poly(diallyldimethylammonium chloride)‐capped gold nanoparticles‐nickel ferrite particles‐carbon nanotubes‐chitosan (PDDA‐AuNPs‐NiFe2O4‐CNTs‐CHIT), electropolymerization of poly(o‐phenylenediamine) (PoPD) and immobilization of glucose oxidase (GOx). Biocompatibility and synergy of the MCM enhanced the immobilization and the reaction of GOx and as well as the electron transfer from an oxidation reaction of hydrogen peroxide in the system. The NiFe2O4 was synthesized by co‐precipitation and calcined at 700 °C. Characterization was carried out by field emission scanning electron microscopy (FE‐SEM), energy‐dispersive X‐ray spectroscopy (EDX), Fourier transform infrared spectroscopy (FTIR) and X‐ray diffraction (XRD) which presented both tetrahedral and octahedral metal stretching with a cubic NiFe2O4 crystal phase. The GOx/PoPD/MCM/GCE yielded a 0.77 s?1 charge transfer rate constant (Ks), a 2.28×10?6 cm2 s?1 diffusion coefficient value (D), a 0.21 mm2 electroactive surface area (Ae) and a 1.93×10?8 mol cm?2 surface concentration ( ) as determined by cyclic voltammetry. The modified electrode showed a durable operation time (n=97, more than 50 % I), repeatability (%RSD=0.38, n=10), reproducibility (%RSD=1.60, n=10), high sensitivity (853.07 μA mM?1 cm?2), selectivity without effects of electroactive species (aspirin, uric acid, caffeine, cholesterol, ascorbic acid and dopamine) and two linear ranges from 0.5 to 10 μM (R2=0.998) and 10 to 15,000 μM (R2=0.991) with a low detection limit (0.35 μM, S/N=3). Its Michaelis‐Menten constant (Km) was calculated as 93.51 μM with 46.30 μA maximum current (Imax). This proposed simple method was successfully applied for glucose determination in human blood samples.  相似文献   

13.
A xanthine biosensor was fabricated by the covalent immobilization of xanthine oxidase (XO) onto a functionalized conducting polymer (Poly‐5, 2′: 5′, 2″‐terthiophine‐3‐carboxylic acid), poly‐TTCA through the formation of amide bond between carboxylic acid groups of poly‐TTCA and amine groups of enzyme. The immobilization of XO onto the conducting polymer (XO/poly‐TTCA) was characterized using cyclic voltammetry, quartz crystal microbalance (QCM), and X‐ray photoelectron spectroscopy (XPS) techniques. The direct electron transfer of the immobilized XO at poly‐TTCA was found to be quasireversible and the electron transfer rate constant was determined to be 0.73 s?1. The biosensor efficiently detected xanthine through oxidation at +0.35 V and reduction at ?0.25 V (versus Ag/AgCl) of enzymatically generated hydrogen peroxide. Various experimental parameters, such as pH, temperature, and applied potential were optimized. The linear dynamic ranges of anodic and cathodic detections of xanthine were between 5.0×10?6?1.0×10?4 M and 5.0×10?7 to 1.0×10?4 M, respectively. The detection limits were determined to be of 1.0×10?6 M and 9.0×10?8 M with anodic and cathodic processes, respectively. The applicability of the biosensor was tested by detecting xanthine in blood serum and urine real samples.  相似文献   

14.
《Electroanalysis》2006,18(4):345-350
Gold modified nanoporous silica based magnetic microparticles have been prepared as support for the immobilization of the enzyme horseradish peroxidase (HRP). The enzyme modified gold microparticles were retained onto the surface of a solid carbon paste electrode with the help of a permanent magnet. The analytical performances of the resulting biosensor were characterized by studying hydroquinone (HQ) and hydrogen peroxide. The former was monitored by the direct electroreduction of the biocatalytically generated quinone. Several experimental parameters influencing the biosensor response were investigated. A linear response to HQ was obtained in the concentration range comprised between 5×10?7 and 4.5×10?6 M with a detection limit of 4×10?7 M. The enzyme electrode provided a linear response to hydrogen peroxide over a concentration range comprised between 5×10?7?1.3×10?4 M with a detection limit of 4×10?7 M. The inhibition of the biosensor response in the presence of thiols e.g. cysteine, captopril, glutathione and Nacystelyn (NAL) has been pointed out.  相似文献   

15.
A cationic quinine‐imide dye brilliant cresyl blue (BCB) and horseradish peroxidase (HRP) were co‐immobilized within ormosil on multiwalled carbon nanotubes modified glassy carbon electrode for the fabrication of highly sensitive and selective hydrogen peroxide biosensor. The presence of epoxy group in ormosil as organic moiety improves the mechanical strength and transparency of the film and amino group provides biocompatible microenvironment for the immobilization of enzyme. The presence of MWCNTs improved the conductivity of the nanocomposite film. The surface characterization of MWCNT modified ormosil nanocomposite film was performed with scanning electron microscopy (SEM) and atomic force microscopy (AFM). Cyclic voltammetry and amperometry measurements were used to study and optimize the performance of the resulting peroxide biosensor. The apparent Michaelis–Menten constant was determined to be 1.5 mM. The proposed H2O2 biosensor exhibited wide linear range from 3×10?7 to 1×10?4 M, and low detection limit 1×10?7 M (S/N=3) with fast response time <5 s. The probable interferences in bio‐matrix were selected to test the selectivity and no significant response was observed in the biosensor. This biosensor possessed good analytical performance and long term storage stability.  相似文献   

16.
A novel carbon paste electrode modified with carbon nanotubes and 5‐amino‐2′‐ethyl‐biphenyl‐2‐ol (5AEB) was fabricated. The electrochemical study of the modified electrode, as well as its efficiency for electrocatalytic oxidation of levodopa (LD) and carbidopa (CD), is described. Cyclic voltammetry (CV) was used to investigate the redox properties of this modified electrode at various scan rates. The apparent charge transfer rate constant, ks, and transfer coefficient, a, for electron transfer between 5AEB and CPE were calculated as 17.3 s?1 and 0.5, respectively. Square wave voltammetry (SWV) exhibits a linear dynamic range from 2.5×10?7 to 2.0×10?4 M and a detection limit of 9.0×10?8 M for LD.  相似文献   

17.
《Electroanalysis》2017,29(9):2114-2124
A novel and sensitive amperometric biosensor for L‐lysine determination based on a glassy carbon electrode (GCE) modified with graphene (GR) and redox polymer poly(vinylferrocene) (PVF) was constructed. L‐lysine‐α‐oxidase was immobilized onto the modified GCE by a glutaraldehyde/bovine serum albumin cross‐linking procedure. SEM, CV and EIS were used for the characterization of the surface morphology and stepwise fabrication processes of PVF/GR composite. Optimal composition of the biosensor and experimental conditions that affect the performance of the biosensor are discussed. The effect of buffer pH on biosensor response was studied in detail over a wide pH range. L‐lysine biosensor displayed a linear range of 9.9×10−7 ‐ 3.1×10−4 M with a low detection limit of 2.3×10−7 M and KM app value of 0.4 mM. The L‐lysine biosensor was tested using pharmaceutical sample and cheese with satisfactory results.  相似文献   

18.
A label‐free DNA biosensor based on three‐dimensional reduced graphene oxide (3D‐rGO) and polyaniline (PANI) nanofibers modified glassy carbon electrode (GCE) was successfully developed for supersensitive detection of breast cancer BRCA1. The results demonstrated that 3D‐rGO and PANI nanofibers had synergic effects for reducing the charge transfer resistance (Rct), meaning a huge enhancement in electrochemical activity of 3D‐rGO‐PANI/GCE. Probe DNA could be immobilized on 3D‐rGO‐PANI/GCE for special and sensitive recognition of target DNA (1.0×10?15–1.0×10?7 M) with a theoretical LOD of 3.01×10?16 M (3S/m). Furthermore, this proposed nano‐biosensor could directly detect BRCA1 in real blood samples.  相似文献   

19.
We report here a novel carbon paste electrode (CPE) which is able to quantitatively sense tramadol under physiological conditions without sample preparation step. The selectivity of CPE is modified by applying molecularly imprinted polymer (MIP) technology. Multiwalled carbon nanotubes (MWCNTs) are incorporated in the structure of CPE to improve the conductivity and the ion‐to‐electron transduction. The electrode shows a wide dynamic linear range for tramadol from 10?7 to 10?3 M. The observed limit of detection and % RSD are 5×10?7 M and 1.8 %, respectively. Finally, the proposed method is applied to determine tramadol in urine and medicinal tablets.  相似文献   

20.
《Electroanalysis》2004,16(23):1992-1998
A carbon nanotubes‐based amperometric cholesterol biosensor has been fabricated through layer‐by‐layer (LBL) deposition of a cationic polyelectrolyte (PDDA, poly(diallyldimethylammonium chloride)) and cholesterol oxidase (ChOx) on multi‐walled carbon nanotubes (MWNTs)‐modified gold electrode, followed by electrochemical generation of a nonconducting poly(o‐phenylenediamine) (PPD) film as the protective coating. Electrochemical impedance measurements have shown that PDDA/ChOx multilayer film could be formed uniformly on MWNTs‐modified gold electrode. Due to the strong electrocatalytic properties of MWNTs toward H2O2 and the low permeability of PPD film for electroacitve species, such as ascorbic acid, uric acid and acetaminophen, the biosensor has shown high sensitivity and good anti‐interferent ability in the detection of cholesterol. The effect of the pH value of the detection solution on the response of the biosensor was also investigated. A linear range up to 6.0 mM has been observed for the biosensor with a detection limit of 0.2 mM. The apparent Michaelis‐Menten constant and the maximum response current density were calculated to be 7.17 mM and 7.32 μA cm?2, respectively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号