首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 218 毫秒
1.
We report the simultaneous electroanalytical determination of Pb2+ and Cd2+ by linear sweep anodic stripping voltammetry (LSASV) using an antimony nanoparticle modified boron doped diamond (Sb‐BDD) electrode. Sb deposition was performed in situ with the analytes, from a solution of 1 mg L?1 SbCl3 in 0.1 M HCl (pH 1). Pb2+ inhibited the detection of Cd2+ during simultaneous additions at the bare BDD electrode, whereas in the presence of antimony, both peaks were readily discernable and quantifiable over the linear range 50–500 μg L?1.  相似文献   

2.
The electrochemical characteristics of multi-component phenolic pollutants, such as phenol (Ph), hydroquinone (HQ) and 4-nitrophenol (4-NP), were investigated on boron-doped diamond (BDD) film electrode by differential pulse voltammetry (DPV) technique. A simple and feasible platform was accordingly established for the direct and simultaneous determination of these three phenolic pollutants. Results showed that, Ph, HQ and 4-NP gave obvious oxidation peaks on BDD electrode at the potential of 1.24, 0.76 and 1.52 V, respectively. Each of them displayed good linear relationship between their oxidation peak currents and their corresponding concentrations in a rather wide range coexisting with one or two of the other phenolic pollutants. The detection limits of Ph, HQ and 4-NP were estimated to be as low as 1.82×10^-6, 1.67×10^-6 and 1.44×10^-6 mol·L^-1, respectively. Therefore, a promising direct and simultaneous electrochemical determination method of multi-component phenolic pollutants in wastewater samples was constructed successfully on BDD electrode with advantages being rapid, simple, convenient, sensitive, in situ and inexpensive.  相似文献   

3.
An electrochemical method for the simultaneous determination of benzene, toluene and xylenes (BTX) in water was developed using square‐wave voltammetry (SWV). The determination of BTX was carried out using a cathodically pre‐treated boron‐doped diamond electrode (BDD) using 0.1 mol L?1 H2SO4 as supporting electrolyte. In the SWV measurements using the BDD, the oxidation peak potentials of the total xylenes‐toluene and toluene‐benzene couples, present in ternary mixtures, display separations of about 100 and 200 mV, respectively. The attained detection limits for the simultaneous determination of benzene, toluene and total xylenes were 3.0×10?7, 8.0×10?7 and 9.1×10?7 mol L?1, respectively. The recovery values taken in ternary mixtures of benzene, toluene and total xylenes in aqueous solutions are 98.9 %, 99.2 % and 99.4 %, respectively.  相似文献   

4.
We report the simultaneous electroanalytical determination of Pb2+ and Cd2+ by square‐wave anodic stripping voltammetry (SWASV) using a bismuth nanoparticle modified boron doped diamond (Bi‐BDD) electrode. Bi deposition was performed in situ with the analytes, from a solution of 0.1 mM Bi(NO3)3 in 0.1 M HClO4 (pH 1.2), and gave detection limits of 1.9 μg L?1 and 2.3 μg L?1 for Pb(II) and Cd(II) respectively. Pb2+ and Cd2+ could not be detected simultaneously at a bare BDD electrode, whilst on a bulk Bi macro electrode (BiBE) the limits of detection for the simultaneous determination of Pb2+ and Cd2+ were ca. ten times higher.  相似文献   

5.
The present work describes the individual, selective and simultaneous quantification of acetaminophen (ACP) and tramadol hydrochloride (TRA) using a modification‐free boron‐doped diamond (BDD) electrode. Cyclic voltammetric measurements revealed that the profile of the binary mixtures of ACP and TRA were manifested by two irreversible oxidation peaks at about +1.04 V (for ACP) and +1.61 V (for TRA) in Britton‐Robinson (BR) buffer pH 3.0. TRA oxidation peak was significantly improved in the presence of anionic surfactant, sodium dodecyl sulfate (SDS), while ACP signal did not change. By employing square‐wave stripping mode in BR buffer pH 3.0 containing 8×10?4 mol L?1 SDS after 30 s accumulation under open‐circuit voltage, the BDD electrode could be used for quantification of ACP and TRA simultaneously in the ranges 1.0–70 μg mL?1 (6.6×10?6–4.6×10?4 mol L?1) and 1.0–70 μg mL?1 (3.3×10?6–2.3×10?4 mol L?1), with detection limits of 0.11 μg mL?1 (7.3×10?7 mol L?1) and 0.13 μg mL?1 (4.3×10?7 mol L?1), respectively. The practical applicability of the proposed approach was tested for the individual and simultaneous quantification of ACP and/or TRA in the pharmaceutical dosage forms.  相似文献   

6.
The development and validation of a multidimensional HPLC method using an on-line clean-up column coupled with amperometric detection employing a boron-doped diamond (BDD) electrode for the simultaneous determination of sulfamethoxazole (SMX) and trimethoprim (TMP) in bovine milk are presented. Aliquots of pre-prepared skim-milk samples were directly injected into a RAM octyl-BSA column in order to remove proteins that otherwise would interfere with milk analysis. After exclusion of the milk proteins, SMX and TMP were transferred to the analytical column (an octyl column) and the separation of the compounds from one another and from other endogenous milk components was achieved. SMX and TMP were detected amperometrically at 1.25 V vs. Ag/AgCl (3.0 mol L−1 KCl). Results with good linearity in the concentration ranges 50-800 and 25-400 μg L−1 for SMX and TMP, respectively, were obtained and no fouling of the BDD electrode was observed within the experimental period of several hours. The intra- and inter-assay coefficients of variation were less than 10% for both drugs and the obtained LOD values for SMX and TMP were 25.0 and 15.0 μg L−1, respectively.  相似文献   

7.
A new electrochemical sensor based on a carbon nanotube paste electrode modified with a Santa Barbara Amorphous material (SBA-15) decorated with silver nanoparticles, namely CNT/SBA/Ag-PE, was developed. It was successfully applied for individual and simultaneous determination of both paracetamol (PC) and sulfamethoxazole (SMZ) medicines. The electrode exhibited a linear dynamic range of 0.12–110 μmol L−1 for paracetamol and 0.06–70 μmol L−1 for sulfamethoxazole, and detection limits of 38 and 19 nmol L−1, respectively. The proposed sensor offered high sensitivity, fast response time and the potential for detecting both drugs simultaneously. The CNT/SBA/Ag-PE enabled the simultaneous determination of PC and SMZ in urine samples with high recovery rates.  相似文献   

8.
A cathodically pretreated boron‐doped diamond electrode was used for the simultaneous anodic determination of ascorbic acid (AA) and caffeine (CAF) by differential pulse voltammetry. Linear calibration curves (r=0.999) were obtained from 1.9×10?5 to 2.1×10?4 mol L?1 for AA and from 9.7×10?6 to 1.1×10?4 mol L?1 for CAF, with detection limits of 19 μmol L?1 and 7.0 μmol L?1, respectively. This method was successfully applied for the determination of AA and CAF in pharmaceutical formulations, with results equal to those obtained using a HPLC reference method.  相似文献   

9.
In this article a sensitive differential pulse stripping voltammetry technique on Nafion‐coated bismuth‐film electrode (NCBFE) was studied for the simultaneous determination of zinc, cadmium, and lead ions in blood samples at ultra trace levels. The measurement results were in excellent agreement with those obtained from atomic absorption spectroscopy. Various operational parameters were investigated and discussed in terms of their effect on the measurement signals. Under optimal conditions, calibration curves for the simultaneous determination of zinc, cadmium, and lead ions were achieved, based on three times the standard deviation of the baseline, the limits of detection were 0.09 μg L?1 for Cd(II), 0.13 μg L?1 for Pb(II), and 0.97 μg L?1 for Zn(II) respectively.  相似文献   

10.
A 2,2′‐azinobis (3‐ethylbenzothiazoline‐6‐sulfonate) diammonium salt (ABTS)‐multiwalled carbon nanotubes (MWCNTs) nanocomposite/Bi film modified glassy carbon (GC) electrode was constructed for the differential pulse stripping voltammetric determination of trace Pb2+ and Cd2+. This electrode was more sensitive than ABTS‐free Bi/GC and Bi/MWCNTs/GC electrodes. Linear responses were obtained in the range from 0.5 to 35 μg L?1 for Cd2+ and 0.2 to 50 μg L?1 Pb(II), with detection limits of 0.2 μg L?1 for Cd2+ and 0.1 μg L?1 for Pb2+, respectively. This sensor was applied to the simultaneous detection of Cd2+ and Pb2+ in water samples with satisfactory recovery.  相似文献   

11.
Yavuz Yardım 《Electroanalysis》2011,23(10):2491-2497
In the present paper, a sensitive electroanalytical methodology for the determination of capsaicin using adsorptive stripping voltammetry (AdSV) at a boron‐doped diamond (BDD) electrode is presented. The voltammetric results indicate that in the presence of sodium dodecylsulfate (SDS) the BDD electrode remarkably enhances the oxidation of capsaicin which leads to an improvement of the peak current with a shift of the peak potential to less negative values. A linear working range of 0.05 to 6.0 µg mL?1 (0.16–20 µM) with a detection limit of 0.012 µg mL?1 (0.034 µM) has been obtained using BDD electrode by AdSV.  相似文献   

12.
《Electroanalysis》2017,29(4):1014-1021
An electrochemical device was developed for the simultaneous determination of sulfamethoxazole (SMX) and trimethoprim (TMP) using differential pulse voltammetry and glassy carbon (GC) electrodes modified with reduced graphene oxide (rGO) and silver nanoparticle (AgNP) composites, synthesised using both chemical and electrochemical methods. The morphology and electrochemical behaviour of the GC electrodes modified with the rGO/AgNP (chemical method) and rGO‐AgNP (electrochemical method) composites were characterised by scanning electron microscopy and cyclic voltammetry. These techniques demonstrated that, in both methods, the graphene oxide was modified by the AgNPs, and the composite synthesised by the electrochemical method showed a better dispersion of the nanoparticles, resulting in an increase in the surface area compared to the rGO/AgNP composite. The GC/rGO‐AgNP electrode was evaluated and optimised for the simultaneous determination of SMX and TMP, achieving detection limits of 0.6 μmol L−1 for the SMX and 0.4 μmol L−1 for the TMP. The proposed GC/rGO‐AgNP electrochemical device was successfully applied to the simultaneous determination of SMX and TMP in wastewaters samples.  相似文献   

13.
This work demonstrates gold nanoparticles (AuNPs)/functionalized multiwalled carbon nanotubes (f‐MWCNT) composite film modified gold electrode via covalent‐bonding interaction self‐assembly technique for simultaneous determination of salsolinol (Sal) and uric Acid (UA) in the presence of high concentration of ascorbic acid (AA). In pH 7.0 PBS, the composite film modified electrode exhibits excellent voltammetric response for Sal and UA, while AA shows no voltammetric response. The oxidation peak current is linearly increased with concentrations of Sal from 0.24–11.76 μmol L?1 and of UA from 3.36–96.36 μmol L?1, respectively. The detection limits of Sal and UA is 3.2×10?8 mol L?1 and 1.7×10?7 mol L?1 , respectively.  相似文献   

14.
《Electroanalysis》2017,29(7):1691-1699
The simultaneous voltammetric determination of melatonin (MT) and pyridoxine (PY) has been carried out at a cathodically pretreated boron‐doped diamond electrode. By using cyclic voltammetry, a separation of the oxidation peak potentials of both compounds present in mixture was about 0.47 V in Britton‐Robinson buffer, pH 2. The results obtained by square‐wave voltammetry allowed a method to be developed for determination of MT and PY simultaneously in the ranges 1–100 μg mL−1 (4.3×10−6–4.3×10−4 mol L−1) and 10–175 μg mL−1 (4.9×10−5–8.5×10−4 mol L−1), with detection limits of 0.14 μg mL−1 (6.0×10−7 mol L−1) and 1.35 μg mL−1 (6.6×10−6 mol L−1), respectively. The proposed method was successfully to the dietary supplements samples containing these compounds for health‐caring purposes.  相似文献   

15.
A convenient and sensitive method was developed for the simultaneous determination of Ponceau-4R and Allura Red using an ionic liquid modified expanded graphite paste electrode (IL-EGPE). The IL-EGPE was prepared by mixing ionic liquid-expanded graphite (IL-EG) composites with solid paraffin. Based on the advantageous functions of IL and EG, IL-EGPE showed enhanced electrocatalytic activity towards the simultaneous oxidation of Ponceau-4R and Allura Red. Under optimal experimental conditions, the IL-EGPE exhibited wide linear responses to Ponceau-4R and Allura Red ranging from 6.0 to 7.5 mg L?1 and 5.0 to 0.5 mg L?1, respectively. The detection limits for Ponceau-4R and Allura Red were 1.15 and 0.89 μg L?1 at a signal-to-noise ratio of 3, respectively. The designed electrode showed good reproducibility, stability and reusability. The proposed method was successfully applied in the simultaneous determination of Ponceau-4R and Allura Red in soft drinks. This method presented a simple, rapid and sensitive platform for simultaneous determination of Ponceau-4R and Allura Red and would become a versatile and powerful tool for food safety.  相似文献   

16.
The electrochemical oxidation of procaine hydrochloride (PC?HCL, 2‐diethylaminoethyl 4‐aminobenzoate hydrochloride) was investigated at as‐deposited boron‐doped diamond (ad‐BDD) electrode, anodically oxidized BDD (ao‐BDD) electrode and glassy carbon (GC) electrode using cyclic voltammetry (CV). Well‐defined cyclic voltammograms were obtained for PC?HCL oxidation with high signal‐to‐background (S/B) ratio, low tendency for adsorption, good reproducibility and long‐term stability at ad‐BDD electrode, demonstrating its superior electrochemical behavior and significant advantages in contrast to ao‐BDD and GC electrode. At 100 μM PC?HCL, the voltammetric S/B ratio was nearly one order of magnitude higher at an ad‐BDD electrode than that at a GC electrode. In a separate set of experiments for oxidation of 100 μM PC?HCL, 96%, 92% and 84% of the initial oxidation peak current was retained at the ad‐BDD, ao‐BDD and GC electrode, respectively, by stirring the solution after the tenth cycle. The current response was linearly proportional to the square root of the scan rate within the range 10–1000 mV s?1 in 10 μM PC?HCL solutions, indicating that the oxidation process was diffusion‐controlled with negligible adsorption at an ad‐BDD surface. The good linearity was observed for a concentration range from 5 to 200 μM with a linear equation of y=0.03517x+0.65346 (r=0.999), and the detection limit was 0.5 μM for oxidation of PC?HCL at the ad‐BDD electrode. The ad‐BDD electrode could maintain 100% of its original activity after intermittent use for 3 months.  相似文献   

17.
《Electroanalysis》2018,30(8):1880-1885
This work presents a simple and low‐cost method for fast and selective determination of Verapamil (VP) in tablets and human urine samples using a boron‐doped diamond working electrode (BDD) coupled to a flow injection analysis system with multiple pulse amperometric detection (FIA‐MPA). The electrochemical behaviour of VP in 0.1 mol L−1 sulfuric acid showed three merged oxidation peaks at around +1.4 V and upon reverse scan, one reduction peak at 0.0 V (vs. Ag/AgCl). The MPA detection was performed applying a sequence of three potential pulses on BDD electrode: (1) at +1.6 V for VP oxidation, (2) at +0.2 V for reduction of the oxidized product and (3) at +0.1 V for cleaning of the working electrode surface. The FIA system was optimized with injection volume of 150 μL and flow rate of 3.5 mL min−1. The method showed a linear range from 0.8 to 40.0 μmol L−1 (R>0.99) with a low limit of detection of 0.16 μmol L−1, good repeatability (RSD<2.2 %; n=10) and sample throughput (45 h−1). Selective determination of VP in urine was performed at+0.2 V due to absence of interference from ascorbic and uric acids in this potential. The addition‐recovery tests in both samples were close to 100 % and the results were similar to an official method.  相似文献   

18.
《Electroanalysis》2006,18(16):1590-1597
This work proposes the utilization of a boron doped diamond (BDD) electrode as a sensor for pesticides and as well as an anode for electrochemical combustion of Parathion in spiked, pure and natural waters. The square‐wave voltammetry was selected as the electroanalytical technique and the Britton–Robinson buffer as the electrolyte. The electrochemical reduction responses of Parathion were analyzed and compared with those previously obtained using a hanging mercury electrode (HMDE). The detection and quantification limits were calculated from the analytical curves both for BDD and HMDE in Milli‐Q water (2.4 and 7.9 μg L?1 and 3.9 and 12.8 μg L?1 respectively) showing only a slight improvement when used BDD. However, if the application involves polluted natural waters the improvement is accentuated due to the very low adsorption characteristics of BDD, which prevent the fouling of electrode surface by organic pollutants. The BDD was also used as anode for electrochemical remediation of Parathion contamination. In this case, electrolysis was carried out in high positive potential (3.0 V) and lead the electrochemical combustion of Parathion to CO2 and H2O, as measured by the diminishing of total organic carbon in the electrolyte.  相似文献   

19.
《Analytical letters》2012,45(9):1955-1965
Abstract

The anodic voltammetric behavior of 4‐chlorophenol (4‐CP) on a boron‐doped diamond electrode (BDD) in aqueous solution was studied by square‐wave voltammetry. After optimization of the experimental conditions, 4‐CP was determined in a Britton‐Robinson buffer solution with pH 6.0, prepared with pure water. Moreover, mixtures of some different chlorophenols were also investigated and an analytical method was developed for the simultaneous determination of these compounds in natural waters. The oxidation of 4‐CP on BDD was used for analytical purposes and quantification limits as low as 9.2 µg L?1 were obtained. This result illustrates the advantage of using oxidation process currents on BDD electrodes as the analytical signal, even in contaminated matrices. In order to compare the results found here with the conventional methodology to determine chlorophenols, HPLC‐UV‐vis measurements were also performed and were in good agreement with the analytical values obtained by SWV.  相似文献   

20.
The determination of organic and inorganic compounds in a single run is still a great challenge. In this paper, we developed a method for fast simultaneous determination of ascorbic acid (AA) and zinc ions (Zn) using batch injection analysis with detection by square-wave anodic stripping voltammetry (BIA-SWASV). Britton-Robinson (BR) buffer solution (pH=6.0) as the supporting electrolyte and boron doped diamond (BDD) as the working electrode. The method presented favorable analytical characteristics such as fast response (67 injections h−1), low detection limits (0.2 and 5.4 μmol L−1 for Zn ions and AA, respectively) and recovery values of 99±3%.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号