首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
Dilute silica sol‐gel was simply dropped on the surface of a basal plane graphite electrode (BPGE) to form a silica sol‐gel film modified electrode. Direct electrochemical response of cytochrome c (Cyt c) on the modified electrode was observed by cyclic voltammetry (CV). The results suggested that Cyt c could be tightly adsorbed on the surface of the silica sol‐gel film modified electrode. A couple of well‐defined and nearly reversible redox peaks can be observed in a phosphate buffer solution (pH 7.0), which anodic and cathodic peak potentials were at ?0.243 and ?0.306 V (vs. Ag/AgCl), respectively. Cyt c adsorbed on the surface of silica sol‐gel film shows a remarkable electrocatalytic activity for the reduction of oxygen. Based on these, a third‐generation biosensor could be constructed to detect the concentration of oxygen in aqueous solution.  相似文献   

2.
《Electroanalysis》2005,17(10):857-861
The carbon nanotubes decorated nanoplatinum (CNT‐Pt) were prepared using a chemical reduction method and a novel base electrode was constructed by intercalating CNT‐Pt on the surface of a waxed graphite electrode. The results showed that the nano‐particles of platinum at a waxed graphite electrode exhibits high catalytic activity for the reduction of hydrogen peroxide. The cholesterol oxidase (ChOx), chosen as a model enzyme, was immobilized with sol‐gel on the CNT‐Pt base electrode to construct a biosensor. The current response of the biosensor for cholesterol was very rapid (<20 s). The linear range for cholesterol measurement was 4.0×10?6 mol/L ?1.0×10?4 mol/L with a detection limit of 1.4×10?6 mol/L. The experiments also showed that the ChOx/sol‐gel/CNT‐Pt biosensor was sensitive and stable in detecting cholesterol in serum samples.  相似文献   

3.
《Electroanalysis》2003,15(7):608-612
A new type of organically modified sol‐gel/chitosan composite material was developed and used for the construction of glucose biosensor. This material provided good biocompatibility and the stabilizing microenvironment around the enzyme. Ferrocene was immobilized on the surface of glassy carbon electrode as a mediator. The characteristics of the biosensor were studied by cyclic voltammetry and chronoamperometry. The effects of enzyme‐loading, buffer pH, applied potential and several interferences on the response of the enzyme electrode were investigated. The simple and low‐cost glucose biosensor exhibited high sensitivity and good stability.  相似文献   

4.
《Electroanalysis》2004,16(16):1305-1310
A novel amperometric biosensor was constructed for the determination of phenols in pure organic phase. This biosensor was fabricated by immobilizing tyrosinase in a titania sol‐gel membrane which was obtained with a vapor deposition method. This method was facile and avoided the calcination step needed in conventional titania sol‐gel process. The titania sol‐gel membrane could effectively retain the essential water layer around the enzyme molecule needed for maintaining its activity in organic phase. The experimental parameters such as solvent and operating potential were optimized. At ?100 mV this biosensor showed a good amperometric response to phenols in pure chloroform without any mediator and rehydration of the enzyme. For catechol determination the sensor exhibited a fast response of less than 5 seconds. The sensitivity of different phenols was as follows: catechol > phenol > p‐cresol. Additionally, the apparent Michaelis‐Menten constants of the encapsulated tyrosinase to catechol, phenol and p‐cresol were found to be 0.15±0.003, 0.17±0.008 and 0.21±0.004 mM, respectively. The biosensor had also good reproducibility and stability. This work provided a promising platform for the construction of pure organic phase biosensors and the determination of substrates with poor water solubility.  相似文献   

5.
An unmediated hydrogen peroxide (H2O2) biosensor was prepared by co‐immobilizing hemoglobin (Hb) with platinum nanoparticles enhanced poly(chloromethyl thiirane) cross‐linked chitosan (CCCS‐PNs) hybrid film. CCCS could provide a biocompatible microenvironment for Hb and PNs could accelerate the electron transfer between Hb and the electrode. Spectroscopic analysis indicated that the immobilized Hb could maintain its native structure in the CCCS‐PNs hybrid film. Entrapped Hb exhibited direct electrochemistry for its heme Fe(III)/Fe(II) redox couples at ?0.396 V in the CCCS‐PNs hybrid film, as well as peroxidase‐like activity to the reduction of hydrogen peroxide without the aid of an electron mediator.  相似文献   

6.
A novel nanocomposite designed by the assembly of the positively charged poly(diallyldimethylammonium chloride) protected gold nanoparticles (PDDA‐GNPs), and the negatively charged multi‐walled carbon nanotubes (MWCNTs) on ITO electrode via electrostatic interaction, was used as a supporting matrix for immobilizing hemoglobin (Hb) to develop a high‐performance hydrogen peroxide (H2O2) biosensor. The cyclic voltammetrys of immobilized Hb showed a pair of well‐defined and quasi‐reversible redox peaks with the formal potential of ‐0.205V (vs. SCE) and the peak‐to‐peak potential separation of 44 mV at a scan rate of 100 mV×s?1 in 0.1 mol×L?1 pH 7.0 PBS. Under the optimized experimental conditions, a linearity range for determination of H2O2 was from 2.0 × 10?6 to 5.2 × 10?4 mol×L?1 with a correlation coefficient of 0.9994 (n = 37) and a detection limit of 8.4 × 10?7 mol×L?1. The biosensor displayed excellent electrochemical and electrocatalytic response to the reduction of H2O2, high sensitivity, long‐term stability, good bioactivity and selectivity.  相似文献   

7.
A hemoglobin‐titanate composite based biosensor was chosen for determination of H2O2 in an acidic medium. CV results of the Hb‐titanate modified pyrolytic graphite electrode showed a pair of well‐defined, quasi‐reversible redox peaks centered at ?246 mV (vs. Ag/AgCl) in a pH 5.0 HAc‐NaAc buffer solution. The modified electrode exhibited good electrocatalytic response for monitoring H2O2 and had a large linear detection range from 20 μM to 3.2 mM with a detection limit of 8 μM (S/N=3) and a sensitivity of 29.7 mA M?1 cm?2 in the pH 5.0 solution. The biosensor also possessed good long term storage stability.  相似文献   

8.
A novel amperometric glucose biosensor was fabricated by in situ incorporating glucose oxidase (GOD) within the sol‐gel silica film on a Prussian blue (PB) modified electrode. The method is simple and controllable, which combined the merits of in situ immobilizing biomolecules in sol‐gel silica film by electrochemical method and the synergic catalysis effects of PB and GOD molecules. Scanning electron microscopy (SEM) showed that the GOD/sol‐gel silica film was homogeneous with a large number of three‐dimensional nanopores, which not only enhanced mass transport, but also maintained the active configuration of the enzyme molecule and prevented the leakage of enzyme, therefore improved the stability and sensitivity of the biosensor. The fabricated biosensor showed fast response time (10 s), high sensitivity (26.6 mA cm?2 M?1), long‐term stability, good suppression of interference, and linear range of 0.01 mM–5.8 mM with a low detection limit of 0.94 μM for the detection of glucose. In addition, the biosensor was successfully applied to determine glucose in human serum samples.  相似文献   

9.
《Electroanalysis》2004,16(19):1637-1641
A novel nitrite sensor was developed based on the immobilization of a partially quaternized poly(4‐vinylpyridine) complexed with [Os(bpy)2Cl]+/2+ (PVP‐Os) in a porous TiO2 sol‐gel matrix by a vapor deposition method. The preparation process simplified the traditional sol‐gel process and prevented the cracking of conventional sol‐gel derived glasses. Electrochemical behavior of the sensor was characterized by cyclic voltammetry and shows excellent electrocatalytic response for the reduction of nitrite. Effect of operating potential on electrochemical responses of the sensor was explored for optimum analytical performance by using the amperometric method. The stability of the sensor was also evaluated.  相似文献   

10.
《Electroanalysis》2003,15(12):1031-1037
A cholesterol biosensors fabricated by immobilization of cholesterol oxidase (ChOx) in a layer of silicic sol‐gel matrix on the top of a Prussian Blue‐modified glassy carbon electrode was prepared. It is based on the detection of hydrogen peroxide produced by ChOx at ?0.05 V. The half‐lifetime of the biosensor is about 35 days. Cholesterol can be determined in the concentration range of 1×10?6?8×10?5 mol/L with a detection limit of 1.2×10?7 mol/L. Normal interfering compounds, such as ascorbic acid and uric acid do not affect the determination. The high sensitivity and outstanding selectivity are attributed to the Prussian Blue film modified on the sensor.  相似文献   

11.
A new sol‐gel hybrid film based on heterocyclic chromophore, namely 2‐[4′‐(N‐ethyl‐N‐hydroxyethyl)amino phenyl azo]‐4,5‐dicyanoimidazole (IZ), has been synthesized and characterized. The hybrid system possesses a high chromophore loading density up to 65 wt.‐% without observing a phase separation. The initial decomposition temperatures of the chromophore and hybrid material were determined to be 260 and 272 °C, respectively. Poled films show a fairly high and stable nonlinear optical (NLO) response, even at an elevated temperature.

  相似文献   


12.
Sol‐gel bonded packing materials in continuous‐bed columns have been prepared for capillary electrochromatography (CEC). Three packing materials were investigated: small‐pore Spherisorb ODS1 (3 μm, 80 Å) with octadecyl as stationary phase, small‐pore mixed‐mode Spherisorb ODS/SCX (3 μm, 80 Å) with octadecyl and propyl sulfonic acid as stationary phases, and large‐pore Nucleosil ODS (7 μm, 1 400 Å) with octadecyl as stationary phase. The characteristics of these columns were compared in terms of electroosmotic flow, efficiency, inertness, and retention factors. In contrast to columns containing sol‐gel bonded ODS, columns containing sol‐gel bonded mixed‐mode ODS/SCX generated nearly pH independent electroosmotic flow (EOF) over pH 2–9. Columns containing sol‐gel bonded large‐pore ODS produced nearly three times lower reduced plate height than those containing small‐pore ODS. Efficiencies of 220,000 plates per meter and 175,000 plates per meter were obtained from columns containing sol‐gel bonded 7 μm, 1 400 Å ODS and columns containing sol‐gel bonded 3 μm, 80 Å ODS, respectively, which are among the highest reported efficiencies for continuous‐bed columns. In CEC, over one million plates per meter and pH independent EOF are expected from continuous‐bed columns containing sol‐gel bonded 1.5 μm particles with large pores and mixed‐mode stationary phases.  相似文献   

13.
以Ho2O3为反应物,采用水热法制备了纳米磷酸钬(n-HoPO4),并利用场发射扫描电子显微镜(SEM)、能谱分析(EDS)对其进行形貌表征和元素组成分析.将n-HoPO4和血红蛋白(Hb)复合材料修饰于裸玻碳电极(GCE)表面构建生物传感器,实现了对H2O2的电化学检测.采用循环伏安(CV)和电化学交流阻抗(EIS)技术对修饰电极进行表征,结果表明,Hb/n-HoPO4/GCE对H2O2的还原具有良好的电化学催化效果;n-HoPO4具有良好的导电性和生物相容性,促进了Hb与工作电极间的直接电子转移.研究了不同pH值和电化学扫速对修饰电极响应电流的影响.在优化实验条件下,此生物传感器对H2O2在50 ~ 1000 μmol/L范围内表现出良好的线性关系,相关线性系数R=0.999,检出限为17 μmol/L(S/N=3).此生物传感器具有检测范围宽、稳定性和重现性好、抗干扰能力强等优点,可用于实际样品的检测.  相似文献   

14.
《Electroanalysis》2004,16(6):478-490
Ir oxide (IrOx) films, formed electrochemically on bulk Ir metal (Ir/IrOx) and also on sol‐gel (SG) derived non‐silica based nanoparticulate Ir, have been studied as material useful for the detection of hydrogen peroxide, with possible application as a glucose biosensor. H2O2 reduction and oxidation on Ir/IrOx and SG‐derived IrOx films, deposited on various substrates such as Pt, Ir and GC, have been compared to the H2O2 behavior at the bare substrate. It was found that H2O2 reduction proceeds on the underlying electrode substrate, while H2O2 oxidation is independent of the nature of the substrate, therefore occurring via the IrOx film. The reactivity of IrOx towards H2O2 oxidation is similar to that seen at Pt, although IrOx has the additional advantages of excellent stability, insensitivity to common interfering substances, biocompatibility and a linear range of detection, up to at least 12 mM H2O2. At micromolar concentrations of H2O2, a second mode of detection, involving the catalyzed growth of IrOx films at Ir substrates, can be employed. These two methods of H2O2 analysis (oxidation/reduction and enhanced IrOx growth) can also be employed for glucose detection using IrOx‐based glucose biosensors.  相似文献   

15.
《Analytical letters》2012,45(5):818-830
A facile strategy to construct an amperometric biosensor was described for the determination of hydrogen peroxide (H2O2). This biosensor relied on an electrospinning gold nanoparticle-chitosan-poly(vinyl alcohol) composite nanofibers modified ITO electrode, followed by immobilization of hemoglobin (Hb) on the surface. The introduction of nanofibers and gold nanoparticles in the modification of electrode surface not only enhanced the surface area of the modified electrode for enzyme immobilization but also facilitated the electron transfer rate. Under optimum conditions, the sensor was characterized in terms of its morphology by scanning electron microscopy and its electroactivity by cyclic voltammetry and chronoamperometry. Scanning electron microscopy revealed that the obtained nanofibers were uniform. The chronoamperometric behavior of the modified electrode indicated that the immobilized Hb retained electrochemical activity inside the electrospinning fibrous membranes. The electrode responded linearly to H2O2 in a wider concentration range of 5.6 × 10?7 M to 5.2 × 10?2 M with a low detection limit (S/N = 3) of 1.98 × 10?7 M and a short response time of ~4 s, suggesting a much better performance than that of other sensors. Moreover, the biosensor achieved bulk production and exhibited superior properties for the sensitive determination of H2O2, studied namely, long-term stability, good reproducibility, and high selectivity.  相似文献   

16.
Summary: By utilizing the interaction of α‐cyclodextrin (α‐CD) with dodecyl side chains in polymers of x mol‐% dodecyl‐modified poly(acrylic acid) (p(AA/C12(x))), systems that undergo gel‐to‐sol and sol‐to‐gel transitions were successfully constructed. Rheological experiments indicated that addition of α‐CD to the hydrogel of p(AA/C12(5)) caused a drastic decrease in the viscosity, while addition of oligo(α‐CD) to the solution of p(AA/C12(2)) led to a remarkable increase in the viscosity.

Photographs for a gel‐to‐sol transition upon addition of α‐CD to 5.0 g · L−1 p(AA/C12(5)).  相似文献   


17.
A novel method for preparation of hydrogen peroxide biosensor was presented based on immobilization of hemoglobin (Hb) on carbon‐coated iron nanoparticles (CIN). CIN was firstly dispersed in a chitosan solution and cast onto a glassy carbon electrode to form a CIN/chitosan composite film modified electrode. Hb was then immobilized onto the composite film with the cross‐linking of glutaraldehyde. The immobilized Hb displayed a pair of stable and quasireversible redox peaks and excellent electrocatalytic reduction of hydrogen peroxide (H2O2), which leading to an unmediated biosensor for H2O2. The electrocatalytic response exhibited a linear dependence on H2O2 concentration in a wide range from 3.1 μM to 4.0 mM with a detection limit of 1.2 μM (S/N=3). The designed biosensor exhibited acceptable stability, long‐term life and good reproducibility.  相似文献   

18.
A simple procedure was developed to prepare a glassy carbon electrode modified with multi walled carbon nanotubes (MWCNTs) and Celestin blue. Cyclic voltammograms of the modified electrode show stable and a well defined redox couple with surface confined characteristic at wide pH range (2–12). The formal potential of redox couple (E′) shifts linearly toward the negative direction with increasing solution pH. The surface coverage of Celestine blue immobilized on CNTs glassy carbon electrode was approximately 1.95×10?10 mol cm?2. The charge transfer coefficient (α) and heterogeneous electron transfer rate constants (ks) for GC/MWCNTs/Celestine blue were 0.43 and 1.26 s?1, respectively. The modified electrode show strong catalytic effect for reduction of hydrogen peroxide and oxygen at reduced overpotential. The glucose biosensor was fabricated by covering a thin film of sol‐gel composite containing glucose oxides (GOx) on the surface of Celestine blue /MWCNTs modified GC electrode. The biosensor can be used successfully for selective detection of glucose based on the decreasing of cathodic peak current of oxygen. The detection limit, sensitivity and liner calibration rang were 0.3 μM, 18.3 μA/mM and 10 μM–6.0 mM, respectively. The accuracy of the biosensor for glucose detection was evaluated by detection of glucose in a serum sample, using standard addition protocol. In addition biosensor can reach 90% of steady currents in about 3.0 sec and interference effect of the electroactive existing species (ascorbic acid–uric acid and acetaminophen) was eliminated. Furthermore, the apparent Michaelis–Menten constant 2.4 mM, of GOx on the nano composite exhibits excellent bioelectrocatalytic activity of immobilized enzyme toward glucose oxidation. Excellent electrochemical reversibility of redox couple, high stability, technically simple and possibility of preparation at short period of time are of great advantages of this procedure for modification of glucose biosensor.  相似文献   

19.
A simple approach for the preparation of emitter of electrospray ionization mass spectrometry by covalently coating the fused‐silica capillary tip with the conductive carbon‐nanotube sol‐gel composite material (CNTSCM) is described. The CNTSCM was prepared by dispersing single‐walled carbon nanotubes in the sol composed of a mixture of 3‐glycidoxypropyltrimethoxysilane and 3‐aminopropyltrimethoxysilane, and ethanol. The long‐term stability of the prepared ESI emitters was demonstrated by at least 180 h of continuous use. Signal intensity obtained by the prepared emitter was mass‐flux sensitive when the flow rate was lower than 500 nL/min, while the signal intensity performed a concentration dependence when the flow rate was in the range of 500–800 nL/min. The usefulness of such a prepared emitter was demonstrated by the analysis of various types of samples such as organic small molecular drugs, oligosaccharide, peptide, and protein.  相似文献   

20.
A sol‐gel electrode, based on 6‐(4‐nitrophenyl)‐2‐phenyl‐4,4‐dipropyl‐3,5‐diaza‐bicyclo [3,1,0] hex‐2‐ene (NPDBH) as a neutral ionophore, was successfully developed for the detection of Sr2+ in aqueous solutions. Theoretical calculations confirmed NPDBH selectivity toward strontium in comparison with some other metal ions. The electrode responds to Sr2+ ion with a sensitivity of 29.1±0.4 mV/decade over the range 8.0×10?7–1.0×10?1 M. Selectivity coefficients determined by matched potential method (MPM) indicate high selectivity for strontium ions. The electrode has a fast response time of 11 s and a working pH range of 3.0–10.0. The sol‐gel electrode shows detection limit of 7.5×10?8 M.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号