首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
This work reports the evaluation of the combined use of Pd and HF as chemical modifiers for the direct determination of total chromium in waters derived from petroleum exploration employing electrothermal atomic absorption spectrometry (ET AAS). Such waters, usually called as produced waters, have complex composition presenting a number of organic and inorganic substances. When obtained from offshore operations they also present high salinity. In order establish conditions for chromium measurement pyrolysis and atomization curves were built up in different media and employing Pd and HF as chemical modifiers. Also, a detailed study about calibration strategy was performed. At best conditions, pyrolysis and atomization temperatures were 1200 °C and 2600 °C, respectively, and 10 μL of a 500 mg L− 1 Pd solution was added together with 10 μL of a 50% (v/v) HF solution on 20 μL of sample. Obtained results indicate that, in this kind of sample, chromium can be determined by standard addition method or employing external calibration with standard solutions prepared in 0.8 mol L− 1 NaCl medium. In order to evaluate the accuracy of the procedure, a recovery test was performed with seven spiked samples of produced waters. The detection limit, quantification limit and the relative standard deviation in 0.8 mol L− 1 NaCl were also calculated and the values found were 0.45 μg L− 1, 1.5 μg L− 1 and 6.0% (at 2.5 μg L− 1 level), respectively.  相似文献   

2.
A new electroanalytical methodology was developed for the quantification of the phytohormone indole-3-acetic acid (IAA), using a graphite–polyurethane composite electrode (GPU) and the square wave voltammetry (SWV), in 0.1 mol L− 1 phosphoric acid solution (pH 1.6). Analytical curves were constructed under optimized conditions (f = 100 s− 1, a = 50 mV, Ei = 5 mV) and the reached detection and quantification limits were 26 μg L− 1 and 0.2 mg L− 1, respectively. The developed methodology is simple and accurate for the routine determination of IAA. In order to verify the application of the electroanalytical methodology in fortified soil samples without previous treatment, an IAA assay was performed without serious interferences of the soil constituents.  相似文献   

3.
Two greener procedures for flow-injection spectrophotometric determination of nitrite in natural waters were developed and critically compared. Replacement of toxic reagents, waste minimization and treatment were exploited to attend the standards of clean chemistry. The flow system was designed with solenoid micro-pumps in order to minimize reagent consumption and waste generation. The first procedure is based on the Griess diazo-coupling reaction with sulfanilamide and N-(1-naphthyl)ethylenediamine (NED) yielding an azo dye, followed by photodegradation of the low amount of waste generated based on the photo-Fenton reaction. The second procedure is based on the formation of iodine from nitrite and iodide in acid medium in order to avoid the use of toxic reagents. For Griess method, linear response was achieved up to 1.0 mg L− 1, described by the equation A = − 0.007 + 0.460C (mg L− 1), r = 0.999. The detection limit was estimated as 8 μg L− 1 at the 99.7% confidence level and the coefficient of variation was 0.8% (n = 20). The sampling rate was estimated as 108 determinations per hour. The consumption of the most toxic reagent (NED) is reduced 55-fold and 20-fold in comparison to batch method and flow injection with continuous reagent addition, respectively. A colorless residue was obtained by in-line photodegradation with reduction of 87% of the total organic carbon content. The results obtained for natural water samples were in agreement with those achieved by the reference method at the 95% confidence level. For the nitrite–iodide method, linear response was observed up to 2.0 mg L− 1, described by the equation A = − 0.024 + 0.148C (mg L− 1), r = 0.999. The detection limit was estimated as 25 μg L− 1 at the 99.7% confidence level and the coefficient of variation was 0.6% (n = 20). The sampling rate was estimated as 44 determinations per hour. Despite avoiding the use of toxic reagents, the nitrite–iodide method presented worst performance in terms of selectivity and sensitivity.  相似文献   

4.
Tyrosinase/laccase bienzyme biosensor for amperometric determination of phenolic compounds was constructed. Enzymes were immobilized in titania gel matrix. The obtained biosensor was successfully used for determination of 2,6-dimethoxyphenol, 4-tertbutylcatechol, 4-methylcatechol, 3-chlorophenol and catechol. The highest sensitivity and the widest linear range were noticed for catechol, 234 mA L mol− 1 and 2.0 × 10− 7–3.2 × 10− 5 mol/L, respectively. Detection limit for catechol, at signal-to-noise ratio of 3 was 1.3 × 10− 7 mol/L.  相似文献   

5.
The present work proposes a direct method based on slurry sampling for the determination of zinc and copper in human hair samples by multi-element sequential flame atomic absorption spectrometry. The slurries were prepared by cryogenic grinding and sonication of the samples. The optimization step was performed using univariate methodology and the factors studied were: nature and concentration of the acid solution, amount sample/slurry volume, sonication time, and particle size. The established experimental conditions are the use of a sample mass of 50 mg, 2 mol L− 1 nitric acid solution, sonication time of 20 min and slurry volume of 10 mL. Adopting the optimized conditions, this method allows the determination of zinc and copper with detection limits of 88.3 and 53.3 ng g− 1, respectively, and precision expressed as relative standard deviation (RSD) of 1.7% and 1.6% (both, n = 10) for contents of zinc and copper of 100.0 and 33.3 μg g− 1, respectively. The accuracy was checked and confirmed by analysis of two certified reference materials of human hair. The procedure was applied for the determination of zinc and copper in two human hair samples. The zinc and copper contents varied from 100.0 to 175.6 and from 3.2 to 32.8 μg g− 1, respectively. These samples were also analyzed after complete digestion in a closed system and determination by FAAS. The statistical comparison by t-test (95% confidence level) showed no significant difference between these results.  相似文献   

6.
Vapor generation and atomization conditions in a heated quartz tube to detect Ag, Cd, Co, Cu, Ni and Zn using High Resolution Continuum Source AAS (HRCSAAS), were optimized. Vapors were generated after mixing acidified solutions containing 8-hydroxiquinoline (oxine) with sodium tetrahydroborate. Afterwards, they were swept to the heated quartz cell by an argon flow.Reaction loop size and temperature of the quartz cell were optimized for each element. A temperature of 960 °C was selected as a compromise value to detect most of the metals. Afterwards, a Plackett–Burmann design was proposed to select which parameters were most important. Type of acid and its concentration were the most statistical significant variables. Optimum conditions for sequential detection of Cd, Cu, Ni and Zn were: 1 mg L 1 Co as catalyst, 250 mg L 1 oxine, 0.6 M nitric acid, 1.75% (w/w) sodium tetrahydroborate (prepared in 0.4 (w/v)% NaOH), a reaction loop of 250 µL, and a 25 L h 1 carrier Ar flow. Ag and Co were each detected in their own optimized conditions. Analytical performance of the system was evaluated in connection with a selected pixel number, and spectral correction was used to eliminate NO absorption bands interference in Zn detection. Detection limits were in the range of 1.5–18 μg L 1 for Ag, Cu, Cd and Zn, whereas sensitivity was worst for Co (169 μg L 1) and Ni (586 μg L 1). Atomization in a quartz cell of Co and Ni volatile species, generated by an addition of sodium tetrahydroborate to an acidified solution of the analytes, was reported for the first time in this paper. Precision expressed as RSD(%) had values lower than 10% except for Ni.  相似文献   

7.
Green onions (Allium fistulosum) enriched with 10 or 100 μg mL− 1 Se(IV) or SeMet were analyzed for total selenium and species distribution. Anion and cation exchange chromatographies were applied for the separation of selenium species with mass spectrometric detection. Two different sample preparation methods (NaOH and enzymatic) were compared from the Se extraction efficiency point of view. Total selenium concentration accumulated by the onions reached the 200 μg g− 1 level expressed for dry weight when applying SeMet at a concentration of 100 μg mL− 1 as the source of Se. Speciation studies revealed that both in onion bulbs and leaves the predominant form of organic selenium is Se-methyl-selenocysteine (MeSeCys). When Se(IV) was applied for Se-enrichment at a concentration level of 100 μg mL− 1 both onion leaf and bulb contained a significant amount of inorganic selenium. An unknown compound was also detected.  相似文献   

8.
The voltammetric behavior of 4-methylbenzelidene camphor (MBC) was studied by square wave voltammetry (SWV) using mercury electrode. The experimental condition that provided the highest peak current with the best reduction signal definition of MBC was found in Britton-Robinson buffer and cationic surfactants, cetyltrimethylammoniun bromide (CTABr). A single peak of MBC reduction was observed at − 1.21 V versus Ag/AgCl. The developed methodology was applied for determination of MBC in commercial sunscreen SPF 15, 20 and 30 and for the simultaneous determination when other protection agents were associated, such as benzophenone-3 (BENZO) and octyl methoxycinammate (OMC). Both methodologies had shown good determination values for the analyzed samples. The calculated detection limit was 2.99 × 10− 9 mol L− 1 and the quantification limit was 9.98 × 10− 9 mol L− 1.  相似文献   

9.
In-capillary derivatization and field-amplified sample injection (FASI) coupled to capillary zone electrophoresis (CZE) was evaluated for the analysis of metals (Co(II), Cu(II), Ni(II), and Fe(II)) using 2-(5-Nitro-2-Pyridylazo)-5-(N-Propyl-N-Sulfopropylamino)Phenol (Nitro-PAPS) as the derivatizing agent. For FASI, the optimum conditions were water as sample solvent, 1 s hydrodynamic injection (0.1 psi) of a water plug, 5 s of electrokinetic introduction (10 kV) of the sample. The in-capillary derivatization was successfully achieved with zone-passing strategy in order tandem injection of Nitro-PAPS reagent (0.5 psi, 7 s), a small water plug (0.1 psi, 1 s), and metal ion introduction (10 kV, 5 s). The solution of 45 mmol L− 1 borate pH 9.7 and 1.0 × 10− 5 mol L− 1 Nitro-PAPS containing 20% acetonitrile was used as the running buffer. The limit of detection obtained by the proposed method was lower than those from pre-capillary derivatization about 3–28 times. The recovery of the method was comparable to pre-capillary derivatization method. In-capillary derivatization-FASI-CZE was applied to analysis of metals in wine samples. The results were compared with those obtained by CZE with pre-capillary derivatization method and atomic absorption spectrometry (AAS).  相似文献   

10.
Quantum dots (QDs) or semiconductor nanocrystals have been receiving great interest in the last few years. In this paper, L-cysteine-coated CdSe/CdS core-shell QDs (λem = 585 nm) have been prepared, which have excellent water-solubility. The full width at half maximum (FWHM) of the photoluminescence of these nanocrystals is very narrow (about 30 nm), and the quantum yield (QY) is 15% relative to Rhodamine 6G in ethanol (QY = 95%). With excess free L-cysteine in the solution, the fluorescence intensity of L-cysteine-coated CdSe/CdS QDs showed improved stability. It was found that the fluorescence of L-cysteine-capped CdSe/CdS QDs could be quenched only by copper (II) ions and was insensitive to other physiologically important cations, such as Ca2+, Mg2+, Zn2+, Al3+, Fe3+, Mn2+ and Ni2+ etc. Based on this finding, the quantitative analysis of Cu2+ with L-cysteine-capped CdSe/CdS QDs has been established. The linear range was from 1.0 × 10− 8 to 2.0 × 10− 7 mol L− 1 and the limit of detection (LOD) was 3.0 × 10− 9 mol L− 1 (S/N = 3). The proposed method has first been applied to the determination of Cu2+ in vegetable samples with recoveries of 99.6–105.8%.  相似文献   

11.
During oil and gas exploitation, large amounts of produced water are generated. This water has to be analyzed with relation to the chemical composition to deduce the environmental impact of its discharge after a treatment process. Therefore, a study was carried out to evaluate preliminarily the BTEX (benzene, toluene, ethylbenzene and xylenes), polycyclic aromatic hydrocarbons (PAHs) and metals contents in produced water samples taken from effluents of the Bonsucesso treatment plant located in the city of Carmópolis, the most important oil and gas producer in the State of Sergipe, North-east of Brazil. Three methods were optimized to determine the target compounds. Polycyclic aromatic hydrocarbons were determined by gas chromatography with mass spectrometric detection (GC/MS), volatile aromatic hydrocarbons (BTEX) by gas chromatography with photoionization detector (GC/PID) and metals were analyzed by flame atomic absorption spectrometry (FAAS). The results showed that concentrations of the target compounds in these samples ranged from 96.7 to 1397 μg L− 1 for BTEX, from 0.9 to 10.3 μg L− 1 for PAHs and from 0.003 to 4540 mg L− 1 for metals.  相似文献   

12.
Quercetin can effectively accumulate at multi-walled carbon nanotubes-paraffin oil paste electrodes (CNTPE) and cause a sensitive anodic peak at around 0.32 V (vs. SCE) in a 0.10 M phosphate buffer solution (pH = 4.0). Under optimized conditions, the anodic peak current is linear to quercetin concentration in the ranges of 2.0 × 10− 9−1.0 × 10− 7 M and 1.0 × 10− 7−2.0 × 10− 5 M, and the regression equations are ip (μA) = 0.0017 + 0.928c (μM, r = 0.999) and ip (μA) = 0.183 + 0.0731c (μM, r = 0.995), respectively. This paste electrode can be regenerated by repetitively cycling in a blank solution for about 2 min. A 1.0 × 10− 6 M quercetin solution is measured for 10 times using the same electrode regenerated after every determination, and the relative standard deviation of the peak current is 1.7%. The method has been applied to the determination of quercetin in hydrolysate product of rutin and the recovery is 99.2–102.6%. In comparison with graphite paste electrode, carbon nanotubes-nujol paste electrode and carbon nanotubes casting film modified glassy carbon electrode, the CNTPE gives higher ratio of signal to background current and better defined voltammetric peak.  相似文献   

13.
The N2 and H2 evolution, respectively, were monitored during deposition of Pd and Cu from electroless plating baths to obtain in-process control of the composition during preparation of 3–7 μm thick PdCu membranes on tubular ceramic substrates. Compositions estimated by gas evolution compare favorably to those measured in post-mortem XRD and EDS analyses, mostly differing by not more than 1 at.%. This result suggests that use of gas evolution measurements to enable in-process control of composition to within 1 at.% is feasible. Annealing experiments in an H2 atmosphere demonstrated that, at 893 K, only 48 h are needed to form a stoichiometrically homogeneous, 9.5 μm thick, face centered cubic (fcc) Pd63Cu37 membrane from sequentially deposited layers; at 723 K, the same transformation requires over 2 weeks. The appearance of transient body centered cubic (bcc) and fcc phases with lower Pd contents signaled compositional segregation in the initial stages of alloy formation at 723 and 773 K and could be a source of persistent stoichiometric heterogeneity particularly in bcc PdCu membranes. The H2 fluxes of fcc Pd58Cu42 and Pd70Cu30 membranes were JH2=(1.6±1.1) mol m−2 s−1 exp[(−24.8±0.4)kJ mol−1/RT] and JH2=(3.7±0.6) mol m−2 s−1 exp[(−21.3±1.0)kJ mol−1/RT], respectively, at 100 kPa H2 pressure difference.  相似文献   

14.
The products of ascorbic acid oxidation in the presence of cobalt octa-4,5-carboxy-phthalocyanine sodium salt (TPH) were identified. These include the ascorbate radical (A·), hydroxyl radical (OH·), and hydrogen peroxide (H2O2). The kinetics of accumulation and consumption of the reaction products was studied. For the concentration ranges of ascorbic acid = 0–2.5 ⋅ 10−3 mol L−1 and the catalyst C TPH = 0–3.5 ⋅ 10−5 mol L−1, the the highest possible concentration of the ascorbate radical is ∼10−7 mol L−1, the concentration of H2O2 is 7 ⋅ 10−4 (30% of the starting concentration of ascorbic acid) and the concentration of the hydroxyl radical is at most 10−6 mol L−1.__________Published in Russian in Izvestiya Akademii Nauk. Seriya Khimicheskaya, No. 10, pp. 2224–2228, October, 2004.  相似文献   

15.
A new chelating sorbent has been developed using Amberlite XAD-2 resin anchored with pyrocatechol through –N=C– group. This sorbent, characterised by elemental analysis and infrared (IR) spectra, was used as packing for the minicolumn in an on-line system preconcentration system for cadmium, cobalt, copper and nickel determination. Metal ions were sorbed in the minicolumn, from which it could be eluted directly to the nebulizer–burner system of the flame atomic absorption spectrometer (FAAS). Elution of all metals from minicolumn can be made with 0.50 mol L 1 HCl or HNO3. The enrichment factors obtained were 16 (Cd), 24 (Co), 15 (Cu) and 19 (Ni), for 60 s preconcentration time, and 39 (Cd), 69 (Co), 36 (Cu) and 41 (Ni), if used 180 s preconcentration time. Under the optimum conditions, the proposed procedure allowed the determination of cadmium, cobalt, copper and nickel with detection limits of 0.31, 0.32, 0.39 and 1.64 μg L 1, respectively, when used preconcentration periods of 180 s. The accuracy of the developed procedure was sufficient and evaluated by the analysis of the certified reference materials NIST 1515 apple leaves and NIST 1570a spinach leaves. The method was applied to the analysis of food samples (spinach, black tea and rice flour).  相似文献   

16.
A new molecularly imprinted polymer (MIP) for trace analysis of diclofenac in environmental water samples was prepared by a non-covalent protocol in which diclofenac was used as a template molecule. Diclofenac is a member of the class of drugs termed non-steroidal anti-inflammatory drugs (NSAIDs) which belong to the most frequently detected pharmaceuticals in the water-cycle in Europe. The MIP was synthesized using 2-vinylpyridine (2-VP) and ethylene glycol dimethacrylate (EGDMA) as a functional monomer and cross-linker, respectively, and bulk thermal polymerization method. 1H NMR spectroscopy was used to study the interaction between diclofenac and 2-VP mixed in toluene-d8 in pre-polymerization complex. Two non-covalent bonds were formed i.e. ionic interaction and hydrogen bonding. The binding characteristics of the MIP and diclofenac were evaluated using equilibrium binding experiments. Scatchard plot analysis revealed that two classes of binding sites were formed with dissociation constants of 55.6 μmol L−1 and 1.43 mmol L−1, respectively. Various parameters affecting the extraction efficiency of the polymers have been evaluated to achieve the selective preconcentration of diclofenac from aqueous samples and to reduce non-specific interactions. This resulted in an MISPE-LC/DAD method allowing the direct extraction of the analyte from sample matrix with a selective wash using dichloromethane/acetonitrile (94:6, v/v) followed by elution with dichloromethane/methanol (85:15, v/v). The recovery of a 100 ng diclofenac standard spiked into 200 mL of blank surface water was 96%, with good precision (RSD = 3.3%, n = 3). The MISPE was demonstrated to be applicable to the analysis of diclofenac in raw influent and final effluent wastewater samples from sewage treatment plant and revealed diclofenac concentrations of 1.31 ± 0.055 μg L−1 (n = 3) and 1.60 ± 0.049 μg L−1 (n = 3), respectively. Yielded results were in good agreement with the corresponding LC/TIS/MS/MS data obtained by an independent laboratory which were 1.40 and 1.50 μg L−1 for influent and effluent samples.  相似文献   

17.
In this paper, we described a simple and rapid method, capillary electrophoresis with electrochemiluminescence (CE–ECL) detection using tris(2,2′-bipyridyl)ruthenium(II) (Ru(bpy)32+), to simultaneously detect pethidine and methadone. Analytes were injected to separation capillary of 67.5 cm length (25 μm i.d., 360 μm o.d.) by electrokinetic injection for 10 s at 10 kV. Under the optimized conditions: ECL detection at 1.20 V, 30 mM sodium phosphate (pH 6.0) as running buffer, separation voltage at 14.0 kV, 5 mM Ru(bpy)32+ with 50 mM sodium phosphate (pH 6.5) in the detection cell, the linear range from 2.0 × 10− 6 to 2.0 × 10− 5 M for pethidine and 5.0 × 10− 6 to 2.0 × 10− 4 M for methadone and detection limits of 0.5 μM for both of them were achieved (S/N = 3). Relative standard derivations of the ECL intensity were 2.09% and 6.59% for pethidine and methadone, respectively.  相似文献   

18.
An analytical methodology was proposed and validated to be applied to the determination of p,p′-DDT and its metabolites p,p′-DDE and p,p′-DDD in fish oil. The analytical procedure presented in this paper involves a single-step clean up process prior to the analysis. A solution of 1,2,3,4-tetrachloronaphtalene was used as internal standard.The analytical technique used was gas chromatography coupled to an electron capture detector. Details on the validation process are provided.The limits of detection ranged from 2.6 to 4.7 pg μL− 1. The BCR 598 standard reference material (cod liver oil) was used to evaluate the performance of the methodology with satisfactory recoveries for all the compounds.The analytes were determined in three different fish oil pills sold in Spain as a supplementary vitamin support. The sum of p,p′-DDT and metabolites was from 13.2 to 51.3 ng g− 1, the dominant compound being p,p′-DDE.  相似文献   

19.
In this paper, a sensitive flow injection chemiluminescence system luminol–myoglobin was described for determining femtogram nitrite. Nitrite bound myoglobin producing the ferric heme nitrite complexes, which catalyzed the electron transfer of luminol to myoglobin leading to fast chemiluminescence. The chemiluminescence intensity in the presence of nitrite was remarkably enhanced compared with that in the absence of it. Under the optimum reaction conditions the chemiluminescence increment produced was proportional to the concentration of nitrite in the range of 0.05 pg ml− 1–1.0 ng ml− 1 (R2 = 0.9991), with a detection limit (3σ) of 20.0 fg ml− 1. At the flow rate of 2.0 ml min− 1, the whole process including sampling and washing could be completed in 0.5 min offering the sampling efficiency of 120 h− 1 accordingly, and the relative standard deviation (RSD) was less than 2.60% (n = 5). It was satisfactory for the application to determine nitrite in human urine samples, and the possible mechanism was proposed.  相似文献   

20.
Occurrence of ochratoxin A in Turkish wines   总被引:1,自引:0,他引:1  
I. Var  B. Kabak   《Microchemical Journal》2007,86(2):241-247
A total of 95 wine samples including 34 white, 10 rosé and 51 red wines originating from four different Turkish areas were analysed for ochratoxin A (OTA). An analytical method based on immunoaffinity column (IAC) for clean-up and high performance liquid chromatography with fluorescence detection (HPLC-FD) was used to determine OTA in wines. The limit of detection (LOD) was estimated as 0.006 ng ml− 1 for white wine and 0.010 ng ml− 1 for rosé and red wines. The limit of quantification (LOQ) was estimated as 0.020 ng ml− 1 in white wine and 0.030 ng ml− 1 in rosé and red wines. Recovery experiments were carried out with spiked samples in the range 0.1–1 ng ml− 1 of OTA. The average OTA recoveries from spiked white wine samples varied from 79.43% to 85.07%; while the mean recoveries for rosé and red wine samples were in the range of 77.48–83.96% and 76.61–83.55%, respectively. OTA was detected in 82 (86%) wine samples at levels of < 0.006–0.815 ng ml− 1, which were below the maximum allowable limit established by the European Community. The mean OTA concentration in red wines was slightly higher than in white and rosé wines. Furthermore, our data indicate that the geographic region of origin has strong influence on OTA level for white, rosé and red wines: wines originating from Thrace (n = 44, mean = 0.158 ng ml− 1) and Aegean (n = 28, mean = 0.060 ng ml− 1) regions of Turkey were more contaminated with OTA compared with wines originating from central (n = 15, mean = 0.027 ng ml−1) and east Anatolia (n = 8, mean = 0.027 ng ml− 1) areas. This study showed that the occurrence of OTA in Turkish wines is high, but at levels that probably leads to a non-significant human exposure to OTA by consumption of wines.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏