首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
《Analytical letters》2012,45(15):2743-2753
Abstract

The electrochemical behavior of 6-MP was studied by cyclic voltammetry at a hanging copper amalgam dropping electrode (HCADE). It was found that 6-MP could form a complex with the Cu(II) stripped from the HCADE, showing a new peak at ?0.19V in the medium of 0.1mol/L LiClO4-0.5mol/L HClO4 solution. The mechanism of the reaction was proposed. This new peak was sensitive and could be used for the determination of trace 6-MP by differential pulse adsorption cathodic stripping voltammetry (DPAdCSV). The linear range was from 3.6×10?10 to 5.3×10?6 mol/L, and the detection limit was about 1.2×10?10 mol/L (S/N=3). The method was also successfully applied to the determination of 6-MP in pharmaceutical tablets.  相似文献   

2.
In this paper, some electrochemical parameters of ethamsylate at a multi-walled carbon nanotube modified glassy carbon electrode, such as the charge number, exchange current density, standard heterogeneous rate constant and diffusion coefficient, were measured by cyclic voltammetry, chronoamperometry and chronocoulometry. The modified electrode exhibits good promotion of the electrochemical reaction of ethamsylate and increases the standard heterogeneous rate constant of ethamsylate greatly. The differential pulse voltammetry responses of ethamsylate were linearly dependent on its concentrations in a range from 2.0 x 10(-6) to 6.0 x 10(-5) mol L(-1), with a detection limit of 4.0 x 10(-7) mol L(-1).  相似文献   

3.
A Pd/IrO(2) co-electrodeposited glassy carbon electrode was prepared and the electrochemical behavior of glutathione (GSH) at this chemically modified electrode (CME) has been studied by cyclic voltammetry (CV). The results indicated that the modified electrode efficiently exhibited electrocatalytic oxidation for GSH with relatively high sensitivity, stability, and long-life. Coupled with high-performance liquid chromatography (HPLC), the Pd/IrO(2) modified electrode was utilized for the electrochemical detection (ECD) of the thiocompounds, glutathione and cysteine (Cys). The peak currents were linear with the substance concentrations in the range of 1.0 x 10(-5) mol L(-1) to 8.0 x 10(-4) mol L(-1) for GSH and 4.0 x 10(-6) mol L(-1) to 2.0 x 10(-4) mol L(-1) for Cys. The detection limits were 2.0 x 10(-6) mol L(-1) for GSH and 5.0 x 10(-7) mol L(-1) for Cys with S/N of 3. The method has been successfully applied to assess the contents of GSH and Cys in rat brain microdialysates.  相似文献   

4.
The electrochemical behavior of colchicine at an acetylene black-dihexadecyl hydrogen phosphate (denoted as AB-DHP) composite film coated glassy carbon electrode (GCE) was investigated using cyclic voltammetry (CV), linear sweep voltammetry (LSV) and differential pulse voltammetry (DPV). Compared with the poor electrochemical signal at the unmodified GCE, the electrochemical response of colchicine at the AB-DHP film modified GCE was greatly improved, as confirmed from the significant peak current enhancement. The remarkable peak current enhancement indicates that the AB-DHP modified GCE has great potential in the sensitive determination of colchicine. Thus, all the experimental conditions, which influence the electrochemical response of colchicine, were studied and the optimum conditions were achieved. Finally, a sensitive and simple voltammetric method with a good linear relationship in the range of 1.0 x 10(-7) approximately 4.0 x 10(-5) mol/L, was developed for the determination of colchicine. The detection limit of colchicine was also examined and a low value of 4.0 x 10(-8) mol/L for 4-min accumulation was obtained (S/N=3). This electrode was successfully applied to detect colchicine in human urine samples.  相似文献   

5.
A hemoglobin (Hb)/gold colloid (nano-Au)/L-cysteine (L-cys)/nano-Au/nanoparticles Pt (nano-Pt)-chitosan (CHIT) composite film-modified platinum disk electrode (abbreviated to modified electrode) has been prepared to construct a biosensor for determination of H(2)O(2). The electrochemical characteristics of the biosensor were studied by cyclic voltammetry and chronoamperometry. The modified process was characterized by electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV). The morphologies of different composite film were investigated with scanning electron microscopy (SEM) and the element of composite film was investigated with X-ray photoelectron spectroscopy (XPS). Analytical parameters such as pH and temperature were also studied. The linear range for the determination of H(2)O(2) is 1.4 x 10(-7) to 6.6 x 10(-3)mol/L with a detection limit of 4.5 x 10(-8)mol/L (S/N=3). The sensor achieved 95% of the steady-state current within 10s. The sensor exhibited high sensitivity (17.62 microA/(mmol L)), selectivity and stability. The method is applied to the determination of H(2)O(2) with satisfactory results.  相似文献   

6.
An electroregenerable carbon paste electrode modified with triiodide ions immobilized in an anion-exchange resin (Lewatit M500) is proposed for the determination of adrenaline in pharmaceutical products by differential-pulse voltammetry (DPV). Adrenaline was chemically converted into adrenochrome by the I3- ions at the electrode surface. The electrochemical reduction back to adrenaline was obtained at a potential of -0.16 V vs. Ag/AgCl (3 mol l(-1) KCl). A 20% decrease of the initial analytical signal was observed after 350-400 determinations; the carbon paste electrode was 100% electroregenerated at a fixed potential of +0.65 V vs. Ag/AgCl (3 mol l(-1) KCl) in 0.1 mol l(-1) KI solution for 20 min. The differential-pulse voltammograms were obtained by applying a sweep potential between 0.0 and -0.34 V, following the adrenochrome reduction at -0.16 V. Under the optimum conditions established, such as pH 6.0; scan rate 20 mV s(-1) and pulse amplitude 50 mV, the calibration curve was linear from 2.0 x 10(-5) to 3.1 x 10(-4) mol l(-1) adrenaline with a detection limit of 3.9 x 10(-6) mol l(-1). The recovery of adrenaline ranged from 99.8 to 103.1% and the RSD was 2.6% for the solution containing 1.0 x 10(-4) mol l(-1) adrenaline (n = 10). The results obtained for adrenaline in pharmaceutical samples using the proposed carbon paste electrode are in agreement with those obtained using a pharmacopoeial procedure at the 95% confidence level.  相似文献   

7.
A chemically modified electrode based on a chitosan-multiwall carbon nanotube (MWNT) coated glassy carbon electrode (GCE) is described, which exhibits an attractive ability to determine dopamine (DA) and ascorbic acid (AA) simultaneously. The modified electrode exhibited a high differential pulse voltammetry (DPV) current response to DA at 0.144 V and AA at -0.029 V (vs. SCE) in a 0.1 mol l(-1) phosphate buffer solution (pH = 7.2). The properties and behaviors of the chitosan-multiwall carbon nanotube modified electrode (MC/GCE) were characterized using cyclic voltammetry (CV) and DPV methods. The mechanism for the discrimination of dopamine from ascorbic acid at MC/GCE is discussed. The linear calibration range for DA and AA were 5 x 10(-7) mol l(-1) to 1 x 10(-4) mol l(-1) (r = 0.997), and 5 x 10(-6) mol l(-1) to 1 x 10(-3) mol l(-1) (r = 0.996), respectively. The MC/GCE showed good sensitivity, selectivity and stability.  相似文献   

8.
Voltammetric determination of niclosamide at a glassy carbon electrode   总被引:1,自引:0,他引:1  
Alemu H  Wagana P  Tseki PF 《The Analyst》2002,127(1):129-134
A very sensitive and selective procedure was developed for the determination of niclosamide based on square-wave voltammetry at a glassy carbon electrode. Cyclic voltammetry was used to investigate the electrochemical reduction of niclosamide at a glassy carbon electrode. Niclosamide was first irreversibly reduced from NO2 to NHOH at -0.659 V in aqueous buffer solution of pH 8.5. Reversible and well defined peaks at -0.164 V and -0.195 V (vs. Ag/AgCl) were obtained that are responsible for two electron peaks between NHOH and NO. Following optimisation of the voltammetric parameters, pH and reproducibility, a linear calibration curve over the range 5 x 10(-8)-1 x 10(-6) mol dm(-3) was achieved. The detection limit was found to be 2.05 x 10(-8) mol dm(-3) niclosamide. For eight successive determinations of 5 x 10(-7) mol dm(-3) niclosamide, a relative standard deviation of 2.4% was obtained. This voltammetric method was applied to the direct determination of niclosamide in tablets. The results of the analysis suggest that the proposed method has promise for the routine determination of niclosamide in the products examined.  相似文献   

9.
Electrochemical behavior of valsartan has been carried out in Britton-Robinson (B-R) buffer solution at pH 7.0 at the mercury film electrode (MFE) by cyclic, linear sweep, differential-pulse and square-wave voltammetry. The property of valsartan adsorption at the MFE using accumulation potential of +0.10 V was observed. The effects of experimental parameters on electrochemical process at the MFE were discussed. Differential-pulse adsorptive stripping and square-wave adsorptive stripping voltammetry for the valsartan determination were proposed, linearity was found in the range of 6.0 x 10(-8) to 4.0 x 10(-6)mol/L. The detection limits were 2.93 x 10(-9) and 3.27 x 10(-9)mol/L, respectively. The proposed methods were also applied to the commercial valsartan with good recoveries.  相似文献   

10.
A flow-injection electrochemiluminescent method for L-cysteine determination has been developed based on its enhancement of the electrochemiluminecence of luminol at a glassy carbon electrode. This method is simple and sensitive for cysteine determination. Under the selected experimental parameters, the linear range for cysteine concentration was 1.0 x 10(-6) - 5.0 x 10(-5) mol/l, and the detection limit was 0.67 micromol/l (S/N = 3). The relative standard deviation for 11 measurements of 1.0 x 10(-5) mol/l cysteine was 4.5%. The proposed method has been applied to the detection of cysteine in pharmaceutical injections with satisfactory results.  相似文献   

11.
The clay mineral montmorillonite has been tested as modifier for the carbon paste electrode with a novel electrode modification technique. The differential pulse voltammetric determination of copper(II) by means of this modified carbon paste electrode has been studied. A detection limit of 4x10(-8) mol/l has been achieved after 10 min preconcentration under open circuit conditions with subsequent anodic stripping voltammetry. The calibration curve for Cu(II) is linear in the range of 4x10(-8)-8x10(-7) mol/l. Pb interferes in a 10-fold molar and Cd and Hg in a 100-fold molar excess. The interference by humic ligands is significant.  相似文献   

12.
Glassy carbon electrode (GCE) is covalently modified with aspartic acid (Asp). The modified electrode is used for the simultaneous electrochemical determination of hydroquinone (HQ) and catechol (CC) and shows an excellent electrocatalytical effect on the oxidation of HQ and CC by cyclic voltammetry (CV) in 0.1 mol/L acetate buffer solution (pH 4.5). In differential pulse voltammetric (DPV) measurements, the modified electrode could separate the oxidation peak potentials of HQ and CC present in binary mixtures by about 101 mV though the bare electrode gave a single broad response. A successful elimination of the fouling effect by the oxidized product of HQ on the response of CC has been achieved at the modified electrode. The determination limit of HQ in the presence of 0.1 mmol/L CC was 9.0 x 10(-7) mol/L and the determination limit of CC in the presence of 0.1 mmol/L HQ was 5.0 x 10(-7) mol/L. The proposed method has been applied to the simultaneous determination of HQ and CC in a water sample with simplicity and high selectivity.  相似文献   

13.
A novel film electrode for the voltammetric determination of tyrosine has been constructed based on electropolymerization of L-serine on a glassy carbon electrode. Voltammetric behaviour of tyrosine on the poly-L-serine film electrode was investigated with cyclic voltammetry and linear sweep voltammetry, and electrochemical parameters were calculated from chronocoulometry. In optimal conditions, the oxidation peak current of tyrosine on the poly-L-serine film electrode was enhanced greatly. A sensitive oxidation peak at 0.90 V was employed to determine tyrosine. A linearity between the oxidation peak current and the tyrosine concentration was obtained in the range of 3.0 x 10(-7) to 1.0 x 10(-4) mol L(-1) with a detection limit of 1.0 x 10(-7)mol L(-1). The practical application of the film electrode in the determination of tyrosine in a commercial amino acid oral solution demonstrated that it has good selectivity and high sensitivity.  相似文献   

14.
The electrochemical behavior of thiamine on a self-assembled electrode of L-cysteine (Cys/SAM/Au) has been investigated and Cys/SAM/Au can be used to detect thiamine using square-wave voltammetry (SWV). At pH 11.40 Britton-Robinson buffer, thiamine exhibits a well-defined anodic peak on Cys/SAM/Au. Under the optimized conditions, the anodic peak current of SWV was linear with the content of thiamine in the range of 1.1 x 10(-8) - 2.2 x 10(-6) mol/L; the detection limit was 5.5 x 10(-9) mol/L. The method was successfully applied to the determination of thiamine in pharmaceutical preparations.  相似文献   

15.
4-Amino-2-mercaptopyrimidine self-assembled monolayer (AMP SAMs/Au) was prepared on a gold electrode. The AMP SAMs/Au was characterized by using attenuated total reflection-fourier transform infrared (ATR-FTIR) and A.C. Impedance. The electrochemical behavior of brucine on AMP SAMs/Au was studied by cyclic voltammetry (CV) and square wave adsorptive stripping voltammetry (SWASV). The modified electrode showed an excellent electrocatalytic activity for the redox of brucine. The catalytic current increased linearly with the concentration of brucine in the range of 4.0 x 10(-7) to 2.0 x 10(-4) mol l(-1) by square wave voltammetry response. The detection limit was 6.0 x 10(-8) mol l(-1).  相似文献   

16.
Introduction Sincecarbonnanotubeswerediscoveredin 1991,theyhaveattractedmuchattentionbecause oftheirremarkablenanostructureswithhighsur- facearea,highelectricalconductivity,goodchemi- calstabilityandsignificantmechanicalstrength[1]. Reportshavealreadybeenpublishedonthecata- lyst[2],nanoscaleelectronicandmechanicalsys- tems[3],andscannedprobemicroscopesandelec- tronfieldemissiontips[4].Itwasreportedthatcar- bonnanotubescouldbemadeintocarbonnan- otubeselectrodesandhavebeensuccessfullyused intheo…  相似文献   

17.
2,5-Dimercapto-1,3,4-thiadiazol (DMTD) can bind on the surface of a gold electrode through the strong gold-sulfur interaction. The fabrication and electrochemical characteristics of the DMTD self-assembled monolayer (SAM)-modified gold electrode were investigated. The DMTD SAM electrode exhibited a significantly increased sensitivity. Cu(II) was accumulated in phosphate buffer (pH 4.6) at a potential of -0.6 V (vs. Ag/AgCl) for 40 s and then determined by anodic stripping voltammetry (ASV) in copper-free phosphate buffer (pH 5.0). The effects of various parameters, such as the pH values of the preconcentration solution and measurement solution, the accumulation potential, and the accumulation time, were investigated. Under the optimum conditions, a linear calibration graph was obtained in the concentration range of 8.0 x 10(-6) to 8.0 x 10(-5) mol l(-1) with a correlation coefficient of 0.9978. The relative standard deviations for eight successive determinations were 4.3 and 2.9% for 1.0 x 10(-5) and 2.0 x 10(-5) mol l(-1) Cu(II), respectively. The detection limit (three times signal to noise) was 4.0 x 10(-7) mol l(-1). The proposed voltammetric method was utilized successfully to detect the concentration of Cu(II) ions in tap water samples.  相似文献   

18.
A modified electrode, based on a hexadecane (C(16))-coated glassy-carbon electrode (GCE) has been developed for the determination of parathion. The electrochemical behavior of parathion was investigated by cyclic voltammetry (CV). The peak potential and peak current were found to depend on the supporting electrolyte and the pH of the buffer solution. The reduction currents for parathion were proportional to parathion concentration over the range 8x10(-8)-2x10(-5) mol L(-1). The detection limit was 2x10(-8) mol L(-1) parathion for an accumulation time of 30 s. The effects of organic and inorganic species on the determination of parathion were also studied. A procedure was developed to extract parathion from spiked soil samples using a mixture of dichloromethane and acetone as the extraction solvent. The complete extraction and analytical procedure are simple, inexpensive and rapid. Parathion was determined in a soil sample by use of linear scan voltammetry (LSV).  相似文献   

19.
郭宪厚  王学亮  郁章玉 《应用化学》2014,31(12):1465-1471
利用循环伏安法制备了石墨烯/铂纳米粒子杂化膜修饰电极,并利用该修饰电极研究了肾上腺素(EP)的电化学行为,建立了测定肾上腺素的电化学方法。 分别利用扫描电子显微镜(SEM)和循环伏安法对电极表面的形貌和电化学性能进行了表征。 试验优化了修饰电极制备过程中影响电极性能的条件和EP的测定条件。 试验结果表明,石墨烯/铂纳米粒子修饰电极对肾上腺素有明显的电催化作用。 在pH=5.0的柠檬酸 磷酸氢二钠缓冲溶液中,EP的氧化峰电流与其浓度在4.4×10-8~2.2×10-6 mol/L的范围内呈良好的线性关系。 线性方程为ipa(10 μA)=0.0753c(mol/L)+3.7653×10-5,r=0.9989,检出限为2.2×10-9 mol/L(S/N=3)。 修饰电极表具有良好的重现性,可用于实际样品的测定。  相似文献   

20.
beta-Alanine was covalently grafted on a glassy carbon electrode (GCE) by amine cation radical formation in the electrooxidation process of the amino-containing compound. X-ray photoelectron spectroscopy (XPS) and cyclic voltammetry (CV) proved the immobilization of beta-alanine monolayer on GCE. The electrode shows strong electrocatalytic functions to dopamine (DA) and ascorbic acid (AA), reducing the overpotentials by 0.20 V and 0.23 V, respectively. Due to its different catalytic effects toward DA and AA, the modified electrode resolved the overlapping voltammetric responses of DA and AA into two well-defined voltammetric peaks by CV or differential pulse voltammetry (DPV), which can be used for the simultaneous determination of these species in a mixture. The catalytic peak current obtained from DPV was linearly related to DA and AA concentrations in the ranges of 4.0 x 10(-6)-5.0 x 10(-4) mol/L and 2.0 x 10(-5)-6.0 x 10(-3) mol/L with correlation coefficients of 0.997 and 0.995, respectively. The detection limits (3 sigma) for DA and AA were 2.4 x 10(-6) mol/L and 1.2 x 10(-5) mol/L, respectively. The electrode shows good sensitivity, selectivity and stability, and has been applied to the determination of DA and AA simultaneously in samples with satisfactory results.  相似文献   