首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Belder D  Deege A  Kohler F  Ludwig M 《Electrophoresis》2002,23(20):3567-3573
The channels of microfluidic glass chips have been coated with poly(vinyl alcohol) (PVA). Applied for microchip electrophoresis, the coated devices exhibited a suppressed electroosmotic flow and improved separation performance. The superior performance of PVA-coated channels could be demonstrated by electrophoretic separations of labeled amines and by video microscopy. While a distorted sample zone is injected using uncoated channels the application of PVA-coated channels results in an improved shape of the sample zone with less band broadening. Applying PVA-coated microchips for the separation of amines labeled with Alexa Fluor 350 even sub-second separations, utilizing a separation length of only 650 microm, could be obtained, while this was not possible using uncoated devices. By using PVA-coated devices rather than an uncoated chip a threefold increase in separation efficiencies could be observed. As the electroosmotic flow (EOF) was suppressed, the anionic compounds were detected at the anode whereas the dominant EOF in uncoated devices resulted in an effective mobility to the cathode. Besides improved separation performance another important feature of the PVA-coated channels was the suppressed adsorption of fluorescent compounds in repetitive runs which results in an improved robustness and detection sensitivity. Applying PVA-coated channels, rinsing or etching steps could be omitted while this was necessary for a reliable operation of uncoated devices.  相似文献   

2.
Belder D  Kohler F  Ludwig M  Tolba K  Piehl N 《Electrophoresis》2006,27(16):3277-3283
Channels in microfluidic glass chips manufactured with the alternative powder blasting technology were permanently coated with poly(vinyl alcohol) (PVA) in order to improve the performance in microchip electrophoresis. The performance of coated and uncoated powder-blasted (pb) devices as well as coated and uncoated wet chemical etched (wc) chips was compared in electrophoretic separations of fluorescently labeled test compounds. The limited electrophoretic resolution obtained in pb-chips could significantly be improved by coating the channels with PVA. The resolution of test compounds in such coated pb-devices was even higher than in uncoated wc-chips. PVA-coated pb-chips could also successfully be applied in chiral separations. While in an uncoated pb-chip using a cyclodextrins buffer only one broad signal was obtained, two well-resolved signals were obtained in a coated device.  相似文献   

3.
On-chip capillary electrophoresis with uncoated and polyvinyl alcohol-coated glass channels in aqueous and nonaqueous dimethyl sulfoxide (DMSO) background electrolyte (BGE) solutions was applied in the separation of five amines derivatized with fluorescein-5-isothiocyanate. In aqueous BGE at pH 9.2, baseline separation of the analytes was not achieved on uncoated glass chips, but the separation was clearly improved when the chip channels were coated with polyvinyl alcohol (PVA). Separation was successful in nonaqueous DMSO electrolyte solution containing ammonium acetate and sodium methoxide, on both uncoated and PVA-coated glass microchips. The differences in the pK(a) values of analytes were probably amplified in DMSO, and all five analytes were at least partly dissociated and were separated. Because the viscosity of DMSO is higher than that of water, the migration times were longer in DMSO.  相似文献   

4.
Herein, we report on a strategy for durable modification of the channel surface in microfluidic glass chips with the neutral hydrophilic-coating material poly(ethylene glycol) PEG-1M-100. Applied in microchip electrophoresis such PEG-coated devices exhibit a suppressed electroosmotic flow and reduced analyte adsorption. The PEG-coated chips were successfully applied in chip electrophoresis of FITC-labelled amines and amino acids and native proteins as well as in chiral separations. The performance of the coated chips was found to be superior compared with uncoated microchips. The coated chips exhibited high stability and the relative standard deviation of migration times in PEG-coated devices was less than 2%.  相似文献   

5.
A poly(methylmethacrylate) chip, provided with two separation channels in the column-coupling (CC) arrangement and on-column conductivity detection sensors and intended, mainly, to isotachophoresis (ITP) and ITP-capillary zone electrophoresis (CZE) separations was developed recently. The present work was aimed at assessing its performance relevant to the detection and quantitation of the ITP analytes. Hydrodynamic (HDF) and electroosmotic (EOF) flows of the solution in the separation compartment of the CC chip were suppressed and electrophoresis was a dominant transport process in the ITP separations with model analytes carried out in this context. When the surfaces of the detection electrodes of the conductivity sensors on the chip were appropriately cleaned qualitative indices of the test analytes [relative step heights (RSHs)], provided by a particular detection sensor, agreed within 1% (expressed via RSDs of the RSH values). Their long-term reproducibilities for one sensor, as estimated from 70 ITP runs repeated in 5 days, were 2% or less. Sensor-to-sensor and chip-to-chip fluctuations of the RSH values for the test analytes were 2.5% or less. In addition, experimentally obtained RSH values agreed well with those predicted by the calculations based on the ITP steady-state model. Reproducibilities of the migration velocities attainable on the CC chips with suppressed EOF and HDF, assessed from the migration time measurements of the ITP boundary between well-defined positions on the separation channels of the chips (140 repeated runs on three chips), ranged from 1.4 to 3.3% for the migration times in the range of 100-200 s. Within-day repeatabilities of the time-based zone lengths for the test analytes characterized 2% RSDs, while their day-to-day repeatabilities were less than 5%. Chip-to-chip reproducibilities of the zone lengths, assessed from the data obtained on three chips for 100 ITP runs, were 5-8%.  相似文献   

6.
A new method for protein analysis, that is, electroosmotic pump-assisted capillary electrophoresis (EOPACE), is developed and demonstrated to possess several advantages over other CE-based techniques. The column employed in EOPACE consists of two linked sections, poly(vinyl alcohol) (PVA)-coated and uncoated capillaries. The PVA-coated capillary column is the section for protein electrophoresis in EOPACE. Electroosmotic flow (EOF) is almost completely suppressed in this hydrophilic polymer coated section, so protein electrophoresis in the PVA-modified capillary is free of irreversible protein adsorption to the capillary inner wall. The uncoated capillary section serves as an electroosmotic pump, since EOF towards cathode occurs at neutral pH in the naked silica capillary. By the separation of a protein mixture containing cytochrome c (Cyt-c), myoglobin and trypsin inhibitor, we have demonstrated the advantages of EOPACE method over other relevant ones such as pressure assisted CE, capillary zone electrophoresis (CZE) with naked capillary and CZE with PVA-coated capillary. A significant feature of EOPACE is that simultaneous separation of cationic, anionic and uncharged proteins at neutral pH can be readily accomplished by a single run, which is impossible or difficult to realize by the other CE-based methods. The high column efficiency and good reproducibility in protein analysis by EOPACE are verified and discussed. In addition, separation of tryptic digests of Cyt-c with the EOPACE system is demonstrated.  相似文献   

7.
The dependency of EOF on the H+-concentration and the related so called pH* value of methanolic electrolytes has been examined with poly(ethylene glycol) (PEG), poly(vinyl alcohol) (PVA) and uncoated capillaries. These results were compared with the pH dependency of EOF of these capillaries using aqueous buffers. In uncoated capillaries the dependency of EOF on the pH(*)-value is very similar for aqueous and methanolic electrolytes. The EOF increases with increasing H+-concentration and pH-hysteresis is observed. In PVA coated capillaries the EOF is strongly reduced over wide pH* or pH ranges for both methanolic electrolytes and aqueous buffers. The EOF in PEG coated capillaries is surprisingly directed to the anode with methanolic electrolytes whereas a reduced cathodic EOF is observed in aqueous electrolytes. The anodic EOF of PEG-coated capillaries in methanolic electrolytes is independent of the pH*-value. The usefulness of PEG- and PVA-coated capillaries for adjusting the EOF in non-aqueous electrolytes for the analysis of isomeric organic acids was demonstrated.  相似文献   

8.
Inexpensive and disposable polyester microchips were fabricated through photolithographic and wet-chemical etching procedure, followed by replication using an imprinting method at room temperature. Laboratory-scale laser-induced fluorescence equipment was employed as a detection system. The generation of electroosmotic flow (EOF) on the polyester channels was discussed in this paper. Surfactants in the running buffer had a significant effect on the EOF depending on their types. The epsilon potential of the electric double layer formed by adsorbing sodium lauryl sulfate molecules on the wall of polyester channels seemed to be constant within the buffer pH investigated. EOF could also be suppressed to zero by adding polyoxyethylene 23 lauryl ether into the running buffer. The separation of two laser dyes was obtained using polyester chips through both micellar electrokinetic chromatography and capillary zone electrophoresis. The polyester channels modified with 10-undecen-1-ol exhibited a dramatically high-separation efficiency compared with the conventional fused-silica capillary tubes.  相似文献   

9.
This paper reports for the first time the use of colored toner to produce polyester toner (PT) ME devices. Colored PT devices were designed in drawing software and printed on a polyester film using a color laser printer with 3600 dpi resolution. The colored toner is composed of a copolymer mixture (styrene and acrylate), wax, silicon dioxide, and pigments. The presence of silica in the toner composition has enhanced the EOF magnitude and improved the analytical performance. For a pH range between 2 and 12, the EOF measured on a magenta PT chip, for example, ranged from 3.8 to 5.8 (× 10?4 cm2 V?1 s?1). Typical separations of inorganic cations (K+, Na+, and Li+) were used as model system to investigate the analytical feasibility of the proposed devices. The repeatability for the migration times of all analytes exhibited RSD values lower than 1% (n = 10). The separation efficiencies found on colored PT devices ranged from 10 000 to 49 000 plates/m, which means between 7 and 23% of the maximum theoretical efficiency on this microfluidic platform (1.85 × 105 plates/m). The improvements achieved on the proposed devices are associated with the small additional amount of silica on the toner composition as well as the printing of channels with smoother surfaces and better uniformity when compared to the conventional PT chips printed with monochromatic laser printers.  相似文献   

10.
Zhang Y  Ping G  Kaji N  Tokeshi M  Baba Y 《Electrophoresis》2007,28(18):3308-3314
We describe a microchip electrophoresis (MCE) method for the assay of unsaturated disaccharides of chondroitin sulfates, dermatan sulfates, and hyaluronic acid (HA). Poly(vinyl alcohol) (PVA) could be irreversibly adsorbed onto poly(methyl methacrylate) (PMMA) substrates and this approach was applicable for dynamic coating. The characteristics of the PMMA surface with PVA coating were evaluated in terms of the wettability, EOF, and adsorption of 2-aminoacridone (AMAC)-labeled disaccharide. The water contact angle decreased from 73 degrees on a pristine PMMA surface to 37.5 degrees on a PVA-coated surface, indicating that the PVA coating increased hydrophilicity. EOF was reduced approximately twofold and was relatively stable. Scanning electron microscopy and fluorescence microscopy images showed that adsorption of AMAC-labeled disaccharides was dramatically suppressed. Using the PVA coating, baseline separation of two pairs of glycosaminoglycan (GAG) disaccharide isomers, DeltaDi-diS(B)/DeltaDi-diS(D) and DeltaDi-0S/DeltaDi-HA, was achieved in Tris-borate buffer within 130 s by MCE.  相似文献   

11.
This review focuses on capillary electrophoretic separations performed on capillary electrophoresis chips (CE chips) with hydrodynamically closed separation systems in a context with transport processes (electroosmotic flow (EOF)) and hydrodynamic flow (HDF)) that may accompany the separations in these devices. It also reflects some relevant works dealing with conventional CE operating under such hydrodynamic conditions. The use of zone electrophoresis (ZE), isotachophoresis (ITP) and their on-line combination (ITP-ZE) on the single-column and column-coupling CE chips with the closed separation systems and related problems are key topics of the review. Some attention is paid to sample pretreatment in the separations performed on the CE chips. Here, mainly potentialities of the ITP-ZE combination in trace analysis applications of the miniaturized systems are discussed in a broader extent. Links between the ZE separation and detection provide a frame for the discussion of current status of the detection on the CE chips. Analytical applications illustrate potentialities of the CE chips operating with the closed separation systems (suppressed HDF and EOF) to the determination of small ions present in various matrices by ZE, ITP and ITP-ZE.  相似文献   

12.
Organic polymers offer many advantages as materials for the construction of microfluidic devices but suffer frequently from the limitation that the electrodynamic flow they support can exhibit considerable instability. This article describes a split-channel microfluidic device that can be used to compensate for changes in electroosmotic flow. The design of the separation system divides an analyte plug after injection between two separation channels of differing length. The two channels are later recombined for single point detection, eliminating the need for a scanning optical detection system. The utility of this simple design lies in the fact that the migration time of any analyte can be referenced to its twin in the parallel separation channel. This eliminates the need for a separate electroosmotic marker and allows mobilities measured in multiple devices to be compared quantitatively. Using a model adopted from the literature, the data from the split channel system can be used to precisely account for the drift that characterizes electrophoretic separations made in a polymer chip. The relative standard deviations of the analyte mobilities measured for replicate runs on multiple devices were reduced from values as high as 20% to ca. 1% RSD. This internal standardization procedure also appears to address other sources of drift in the electroosmotic flow (EOF) supported by the polymer microchannel, eliminating the need for careful monitoring of either the temperature or reservoir pH between separation runs.  相似文献   

13.
The determination of glucose in microfluidic chips made of glass or PMMA was used as a model for the combination of an enzymatic reaction with the separation of compounds. It was based on the enzymatic oxidation of glucose and the amperometric detection of hydrogen peroxide. Real samples frequently contain compounds, such as ascorbic acid, which may interfere with quantitative glucose determinations. Thus, electrophoretic separation of specific from unspecific signals was envisaged by applying electric fields which are also used to control the flow of liquid via electroosmotic effects. Surface charge densities of the capillaries influence the electroosmotic flow (EOF). They are dependent on the chip material and on the adsorption of components from the background electrolyte. Reversal of the EOF after addition of cetyltrimethylammonium bromide (CTAB) and an increase in EOF after addition of sodium dodecylsulfate (SDS) were observed at lower surfactant concentrations with the PMMA chips rather than with the glass chips. For both chip materials these concentrations were below the critical micelle concentration. Effective separation of H2O2 and ascorbic acid was achieved with low CTAB concentrations, which lead to a reduction, but not to a reversal of the EOF. Reversal of the EOF by higher CTAB concentrations or the increase in cathodic EOF by SDS accelerated ascorbic acid transportation and reduced the differences in migration times. Thus, for the specific determination of glucose, glucose oxidase was added together with low CTAB concentrations to the background electrolyte. This avoided interference from ascorbic acid, and data obtained from the analysis of fruit juices showed a good correlation to data obtained from a reference method.  相似文献   

14.
微流控芯片技术因具有微量、快速、高效和高通量等特点,已成为分析化学领域中的研究热点之一.在微流控芯片中,最常见的可用作芯片的材料为玻璃、石英和各种塑料.玻璃和石英有很好的电渗性和光学性质,可采用标准的刻蚀工艺加工和用化学方法进行表面改性,但加工成本较高,封接难度较大.  相似文献   

15.
This paper presents a study of EOF properties of plasma‐polymerized microchannel surfaces and the effects of protein (fibrinogen and lysozyme) adsorption on the EOF behavior of the surface‐modified microchannels. Three plasma polymer surfaces, i.e. tetraglyme, acrylic acid and allylamine, are tested. Results indicate EOF suppression in all plasma‐coated channels compared with the uncoated glass microchannel surfaces. The EOF behaviors of the modified microchannels after exposure to protein solutions are also investigated and show that even low levels of protein adsorption can significantly influence EOF behavior, and in some cases, result in the reversal of flow. The results also highlight that EOF measurement can be used as a method for detecting the presence of proteins within microchannels at low surface coverage (<1 ng/cm2 on glass). Critically, the results illustrate that the non‐fouling tetraglyme plasma polymer is able to sustain EOF. Comparison of the plasma‐polymerized surfaces with conventionally grafted polyelectrolyte surfaces demonstrates the stabilities of the plasma polymer films, enabling multiple EOF runs over 3 days without deterioration in performance. The results of this study clearly demonstrate that plasma polymers enable the surface chemistry of microfluidic devices to be tailored for specific applications. Critically, the deposition of the non‐fouling tetraglyme coating enables stable EOF to be induced in the presence of protein.  相似文献   

16.
玻璃微流控芯片廉价快速制作方法的研究   总被引:3,自引:0,他引:3  
研究了一种玻璃微流控芯片的快速、低成本制作工艺和方法. 该方法采用商品化的显微载玻片(soda-lime玻璃)作为芯片基质材料, 利用AZ 4620光刻胶代替传统工艺中的溅射金属层或多晶硅/氮化硅层作为玻璃刻蚀的掩膜层, 同时利用一种紫外光学胶键合方法代替传统熔融键合方法实现芯片的键合, 整个工艺对玻璃基质材料要求低, 普通微流控芯片(深度小于50 μm)制作流程仅需约3.5 h, 可降低制作成本, 缩短制作周期. 还系统地研究了光刻胶厚度、光刻胶硬烘时间和玻璃腐蚀液配比对玻璃微流控芯片制作的影响, 获得了优化的工艺参数.  相似文献   

17.
Wu D  Luo Y  Zhou X  Dai Z  Lin B 《Electrophoresis》2005,26(1):211-218
A poly(dimethylsiloxane) (PDMS) microfluidic chip surface was modified by multilayer-adsorbed and heat-immobilized poly(vinyl alcohol) (PVA) after oxygen plasma treatment. The reflection absorption infrared spectrum (RAIRS) showed that 88% hydrolyzed PVA adsorbed more strongly than 100% hydrolyzed one on the oxygen plasma-pretreated PDMS surface, and they all had little adsorption on original PDMS surface. Repeating the coating procedure three times was found to produce the most robust and effective coating. PVA coating converted the original PDMS surface from a hydrophobic one into a hydrophilic surface, and suppressed electroosmotic flow (EOF) in the range of pH 3-11. More than 1,000,000 plates/m and baseline resolution were obtained for separation of fluorescently labeled basic proteins (lysozyme, ribonuclease B). Fluorescently labeled acidic proteins (bovine serum albumin, beta-lactoglobulin) and fragments of dsDNA phiX174 RF/HaeIII were also separated satisfactorily in the three-layer 88% PVA-coated PDMS microchip. Good separation of basic proteins was obtained for about 70 consecutive runs.  相似文献   

18.
Omasu F  Nakano Y  Ichiki T 《Electrophoresis》2005,26(6):1163-1167
Cell electrophoretic mobility (EPM) can be used to characterize individual cells. The purpose of this study is to establish reproducible and reliable cell EPM values obtained using microcapillary electrophoresis (microCE) chips. We studied cell electrophoresis on microCE chips through the comprehensive measurement of EPM and zeta potential. The inner wall of microchannels in microCE chips was coated with three kinds of reagents, namely bovine serum albumin (BSA), gelatin, and 2-methacryloyloxyethylphosphorylcholine (MPC) polymer to prevent nonspecific adhesion and interaction between cells and the inner wall. Electrophoresis was conducted in phosphate-buffered saline (pH 4-9) using erythrocytes extracted from sheep whole blood. Electroosmotic flow (EOF) mobility was measured using noncharged particles, and then the true EPM was calculated by subtracting the EOF mobility from the electromigration. MPC polymer coatings in microCE chips reduced the zeta potential of the inner wall and fully prevented nonspecific adhesion. EPM data obtained using microCE chips were almost the same and reproducible over a wide range of pH irrespective of the coating reagent used. In conclusion, reliability in the measurement of cell EPM using microCE chips was realized.  相似文献   

19.
The enantiomers of vildagliptin, an orally available and selective dipeptidyl‐peptidase‐4 inhibitor used for the treatment of type II diabetes, have been separated by CD‐modified CZE, using uncoated fused‐silica capillary. After screening 13 negatively charged CD derivatives as potential chiral selectors, sulfobutyl‐ether‐α‐CD (SBE‐α‐CD) was selected for the enantioseparation. For the optimization, a factorial analysis study was performed by orthogonal experimental design. Six experimental factors were chosen as variable parameters: temperature, applied voltage, chiral selector and BGE concentrations, pH, and the parameters of the hydrodynamic injection. The optimized system still was not considered final as the second peak (S‐enantiomer) migrated too close to the EOF, resulting in a potential inaccuracy during the determination of the chiral impurity. To fine‐tune the method “one factor at a time” variation approach was applied. The final method (applying 15°C capillary temperature, 40 mbar × 4 s hydrodynamic injection, 25 kV voltage in 75 mM acetate‐Tris buffer [pH 4.75] containing 20 mM SBE‐α‐CD as chiral selector) was validated according to the ICH guideline. RSD percentage of the resolution value, migration times, and corrected peak areas were below 5% during testing repeatability and intermediate precision. LOD and LOQ values were found to be 2.5 and 7.5 μg/mL, respectively. The method is considered linear in the 7.5–180 μg/mL range for the R‐enantiomer. The robustness of the method was justified using Plackett–Burmann statistical experimental design.  相似文献   

20.
Microemulsion electrokinetic chromatography (MEEKC) was carried out in a pH 2.5 phosphate buffer to effectively suppress the electroosmotic flow (EOF). With 66.6% (w/w) 25 mM phosphate buffer pH 2.5, 20.0% (w/w) 2-propanol, 6.6% (w/w) 1-butanol, 6.0% (w/w) sodium lauryl sulphate (SDS), and 0.8% (w/w) n-octane as the separation medium, the fat-soluble vitamins A palmitate, E acetate, and D3 were baseline separated within 11 min. With strongly suppressed EOF, the polarity of the separation voltage was reversed (positive electrode at the outlet); the n-octane micro droplets surrounded by negatively charged SDS molecules migrated towards the detector. The aqueous part of the microemulsion was modified with 20% (w/w) 2-propanol to improve partition between the n-octane phase and the surrounding aqueous medium. The fat-soluble vitamins were separated in order of decreasing hydrophobicity with a high migration time stability (repeatable within 0.1% RSD). Excellent accuracy and precision were obtained when the system was applied for the determination of vitamin E acetate in commercial vitamin tablets; quantitative data corresponded to 97.0% of label claim, intra-day results varied within 1.72% RSD (n=6), and inter-day results varied within 3.22% RSD (n=5).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号