首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A high-performance liquid chromatography (HPLC) method with on-line coupled ultraviolet (UV), mass spectrometry (MS) and biochemical detection for acetylcholinesterase (AChE) inhibitory activity has been developed. By combining the separation power of HPLC, the high selectivity of biochemical detection, and the ability to provide molecular mass and structural information of MS, AChE inhibitors can be rapidly identified. The biochemical detection was based on a colorimetric method using Ellman's reagent. The detection limit of galanthamine, an AChE inhibitor, in the HPLC-biochemical detection is 0.3 nmol. The three detector lines used, i.e., UV, MS and Vis for the biochemical detection were recorded simultaneously and the delay times of the peaks obtained were found to be consistent. This on-line post-column detection technique can be used for the identification of AChE inhibitors in plant extracts and other complex mixtures such as combinatorial libraries.  相似文献   

2.
A sensitive LC/MS/MS assay for determining zidovudine (ZDV) and lamivudine (3TC) in human plasma was validated to support antiretroviral pharmacology research programs. After addition of stable labeled isotopic zidovudine (ZDV‐IS) and lamivudine (3TC‐IS) as internal standard, a solid‐phase extraction was performed with an Oasis HLB 1 cm3 cartridge, with recoveries of 92.3% for ZDV and 93.9% for 3TC. A Phenomonex Synergi Hydro‐RP (2.0 × 150 mm) reversed‐phase analytical column was utilized for chromatographic separation. The mobile phase consisted of an aqueous solution of 15% acetonitrile and 0.1% acetic acid. Detection was accomplished by ESI/MS/MS in the positive ion mode, monitoring 268/127, 271/130, 230/112 and 233/115 transitions, for ZDV, ZDV‐IS, 3TC and 3TC‐IS, respectively. The method was linear from 1 to 3000 ng/mL with a minimum quantifiable limit of 1 ng/mL when 100 μL of plasma was analyzed. Validation results demonstrated high accuracy (≤8.3% deviation) and high precision (≤10% CV) for the quality control samples. The method was also shown to be specific and reproducible. The value of the high sensitivity was demonstrated by quantitation of approximately 100 existing samples that had ZDV below the limit of quantitation using a previously validated, less sensitive HPLC‐UV method utilized in the laboratory. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

3.
To detect and identify the electron spin resonance (ESR) silent forms of the α‐(4‐pyridyl‐1‐oxide)‐N‐tert‐butylnitrone (4‐POBN) radical adducts, an electrochemical detector (ECD) was employed as a reactor in the HPLC‐ECD‐UV absorption detector‐ESR‐MS (HPLC‐ECD‐UV‐ESR‐MS). The ECD was employed to regenerate the radical forms from the reduced forms. The reduced forms of the 4‐POBN/pentyl radical adducts were analyzed using the HPLC‐ECD‐UV‐ESR‐MS. On addition of the ECD applied potential of +0.3 V, a peak appeared on the ESR trace of the HPLC‐ECD‐UV‐ESR‐MS analyses, indicating that the radical forms are regenerated from the reduced forms. The HPLC‐ECD‐UV‐ESR‐MS analyses were also performed for the reaction mixtures of phenylhydrazine with CuCl2. Two peaks (peaks I and II) were detected on the UV trace (300 nm) of the HPLC‐ECD‐UV‐ESR‐MS. The mass spectra showed that the peak I and peak II compounds are radical and reduced forms of the 4‐POBN/phenyl radical adducts under the ECD applied potential of 0.0 V. Peak I was only detected on the ESR trace under the ECD applied potential of 0.0 V. In addition to peak I, peak II appeared on the ESR trace under the ECD applied potential of +0.3 V, indicating that the reduced forms are oxidized to the corresponding radical forms.  相似文献   

4.
Targeted multidimensional liquid chromatography (MDLC), commonly referred to as 'coupled-column' or 'heartcutting', has been used extensively since the 1970s for analysis of low concentration constituents in complex biological and environmental samples. A primary benefit of adding additional dimensions of separation to conventional HPLC separations is that the additional resolving power provided by the added dimensions can greatly simplify method development for complex samples. Despite the long history of targeted MDLC, nearly all published reports involve two-dimensional methods, and very few have explored the benefits of adding a third dimension of separation. In this work we capitalize on recent advances in reversed-phase HPLC to construct a three-dimensional HPLC system for targeted analysis built on three very different reversed-phase columns. Using statistical peak overlap theory and one of the most recent models of reversed-phase selectivity we use simulations to show the potential benefit of adding a third dimension to a MDLC system. We then demonstrate this advantage experimentally by developing targeted methods for the analysis of a variety of broadly relevant molecules in different sample matrices including urban wastewater treatment effluent, human urine, and river water. We find in each case that excellent separations of the target compounds from the sample matrix are obtained using one set of very similar separation conditions for all of the target compound/sample matrix combinations, thereby significantly reducing the normally tedious method development process. A rigorous quantitative comparison of this approach to conventional 1DLC-MS/MS also shows that targeted 3DLC with UV detection is quantitatively accurate for the target compounds studied, with method detection limits in the low parts-per-trillion range of concentrations. We believe this work represents a first step toward the development of a targeted 3D analysis system that will be more effective than previous 2D separations as a tool for the rapid development of robust methods for quantitation of low concentration constituents in complex mixtures.  相似文献   

5.
High-performance liquid chromatography (HPLC) and multivariate spectrophotometric methods are described for the simultaneous determination of ambroxol hydrochloride (AM) and doxycycline (DX) in combined pharmaceutical capsules. The chromatographic separation was achieved on reversed-phase C(18) analytical column with a mobile phase consisting of a mixture of 20mM potassium dihydrogen phosphate, pH 6-acetonitrile in ratio of (1:1, v/v) and UV detection at 245 nm. Also, the resolution has been accomplished by using numerical spectrophotometric methods as classical least squares (CLS), principal component regression (PCR) and partial least squares (PLS-1) applied to the UV spectra of the mixture and graphical spectrophotometric method as first derivative of the ratio spectra ((1)DD) method. Analytical figures of merit (FOM), such as sensitivity, selectivity, analytical sensitivity, limit of quantitation and limit of detection were determined for CLS, PLS-1 and PCR methods. The proposed methods were validated and successfully applied for the analysis of pharmaceutical formulation and laboratory-prepared mixtures containing the two component combination.  相似文献   

6.
Rapid, simple and reliable HPLC/UV and LC‐ESI‐MS/MS methods for the simultaneous determination of five active coumarins of Angelicae dahuricae Radix, byakangelicol (1), oxypeucedanin (2), imperatorin (3), phellopterin (4) and isoimperatorin (5) were developed and validated. The separation condition for HPLC/UV was optimized using a Develosil RPAQUEOUS C30 column using 70% acetonitrile in water as the mobile phase. This HPLC/UV method was successful for providing the baseline separation of the five coumarins with no interfering peaks detected in the 70% ethanol extract of Angelicae dahuricae Radix. The specific determination of the five coumarins was also accomplished by a triple quadrupole tandem mass spectrometer equipped with an electrospray ionization source (LC‐ESI‐MS/MS). Multiple reaction monitoring (MRM) in the positive mode was used to enhance the selectivity of detection. The LC‐ESI‐MS/MS methods were successfully applied for the determination of the five major coumarins in Angelicae dahuricae Radix. These HPLC/UV and LC‐ESI‐MS/MS methods were validated in terms of recovery, linearity, accuracy and precision (intra‐ and inter‐day validation). Taken together, the shorter analysis time involved makes these HPLC/UV and LC‐ESI‐MS/MS methods valuable for the commercial quality control of Angelicae dahuricae Radix extracts and its pharmaceutical preparations. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

7.
In order to assess exposure levels of hospital personnel involved in the preparation and administration of antineoplastic drugs, environmental monitoring should be carried out. Wipe samples, pads, gloves and air samples should be collected at the end of each work shift, properly treated and then analysed using instrumental techniques which are sufficiently sensitive and specific to detect even trace amounts of drug. In this study, a method using high performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS), incorporating solid phase extraction (SPE), was validated for determination of methotrexate (MTX) in wipe and air samples. Each step of the method was first developed and optimised using ultraviolet detection (UV), and afterwards tandem mass spectrometry was used to obtain a lower limit of quantitation when the expected drug level was less than the analytical UV detection limit. SPE enabled a 20-fold preconcentration of the analyte when using HPLC/UV and a further 30-fold preconcentration was obtained when analysing samples by HPLC/MS/MS. For example, the limit of quantitation (LLQ) was lowered from 3000 ng on wipe (direct injection onto an HPLC/UV system) to 5 ng on wipe (SPE plus HPLC/MS/MS). 7-hydroxymethotrexate was used as internal standard to assess precision and accuracy.  相似文献   

8.
Immuno‐oncology (IO) is an emerging option to treat cancer malignancies. In the last two years, IO has accounted for more than 90% of the new active drugs in various therapeutic indications of oncology drug development. Bioanalytical methods used for the quantitation of various IO small molecule drugs have been summarized in this review. The most commonly used are HPLC and LC–MS/MS methods. Determination of IO drugs from biological matrices involves drug extraction from the biological matrix, which is mostly achieved by simple protein precipitation, liquid–liquid extraction and solid‐phase extraction. Subsequently, quantitation is usually achieved by LC–MS/MS, but HPLC–UV has also been employed. The bioanalytical methods reported for each drug are briefly discussed and tabulated for easy access. Our review indicates that LC–MS/MS is a versatile and reliable tool for the sensitive, rapid and robust quantitation of IO drugs.  相似文献   

9.
Quantitation of drugs used for the treatment of chronic lymphocytic leukemia in various biological matrices during both pre-clinical and clinical developments is very important, often in routine therapeutic drug monitoring. The first developed methods for quantitation were traditionally done on LC in combination with either UV or fluorescence detection. However, the emergence of LC with mass spectrometry in tandem in early 1990s has revolutionized the quantitation as it has provided better sensitivity and selectivity within a shorter run time; therefore it has become the choice of method for the analysis of various drugs. In this article, an overview of various bioanalytical methods (HPLC or LC–MS/MS) for the quantification of drugs for the treatment of chronic lymphocytic leukemia, along with applicability of these methods, is given.  相似文献   

10.
The current work describes the development of a CZE method with quadrupole QTOF‐MS detection and UV detection for the quantitation of Cyasorb 3529, a common hindered amine light stabilizer (HALS), in polymer materials. Analysis of real polymer samples revealed that the oligomer composition of Cyasorb 3529 changes during processing, a fact hampering the development of a straightforward method for quantitation based on calibration with a Cyasorb 3529 standard. To overcome this obstacle in‐depth investigations of the oligomer composition of this HALS using QTOF‐MS and QTOF‐MS/MS had to be performed whereby 22 new oligomer structures, in addition to the ten structures already described, were identified. Finally, a CZE method for quantitative analysis of this HALS was developed starting with a comprehensive characterization of a Cyasorb 3529 standard using CZE‐QTOF‐MS, subsequently allowing the correct assignment of most Cyasorb 3529 oligomers in an electropherogram with UV detection. Employing the latter detection technique and hexamethyl‐melamine as internal standard, peak areas obtained for the melamine could be correlated with those from the triazine ring, the UV‐absorbing unit present in the HALS. This approach finally allowed proper quantitation of the single oligomers of Cyasorb 3529, an imperative for the quantitative assessment of this HALS in real polymer samples.  相似文献   

11.
RP‐HPLC coupled with fluorescence detection for separation of carbon nanoparticles (CNP) synthesized with microwave‐assisted pyrolysis of citric acid and 1,2‐ethylenediamine is presented. The influence of methanol content and pH of mobile phase on the separation of CNP has been investigated. Under optimal mobile phase and elution gradient conditions, the effect of mole ratio of amine to carboxylic groups (NH2/COOH) in the initial reagents on CNP product is studied. At NH2/COOH = 0.67, the strongest fluorescence CNP sample is obtained. The separated CNP fractions are collected and further characterized by UV‐visible absorption and photoluminescence (PL) spectroscopy, CE, transmission electron microscopy (TEM), and MALDI‐TOF MS. The absorption and PL emission bands of the fractions are bathochromatically shifted with the elution order of CNP on RP‐HPLC. The TEM images prove that CNP are eluted from the smallest to the largest. The MS data show that CNP undergo fragmentations, closely relating to their surface‐attached carboxylic acid and amide/amine moieties. This work highlights the merit of RP‐HPLC coupled with fluorescence detection, TEM, and MS for isolation and characterization of individual CNP species present in a CNP sample.  相似文献   

12.
Hops contain a wide range of polyphenolic compounds with antioxidant properties divided in various chemical classes. These compounds are detected in hop extracts and also in beer as its main product. Based on the careful optimization of column type, column packing, mobile phase composition and gradient steepness, two high-performance liquid chromatography–mass spectrometry (HPLC/MS) methods have been developed. The first method using Purospher Star RP-8e column and the gradient of aqueous acetonitrile containing 0.3% formic acid is optimized for the separation of low polar polyphenolic compounds, while the second one with Zorbax SB-CN column is used for more polar hops and beer components. In this work, more compounds are detected in comparison to previous reports. In total, 49 low polar and 37 polar compounds are detected in studied samples and their molecular weights are determined based on atmospheric pressure chemical ionization (APCI) mass spectra. Some compounds are identified based on the interpretation of their full scan and tandem APCI mass spectra, retention behavior and UV spectra, while the full structure elucidation of other species still requires further research. The quantitation of xanthohumol related prenylflavonoids and bitter acids is done with two detection techniques (APCI-MS and UV detection) providing comparable results. Both compound classes (i.e., prenylflavonoids and bitter acids) are separated and quantitated in a single HPLC run, where numerous other polyphenolics are detected as well.  相似文献   

13.
Rapid and simple HPLC‐UV and LC‐MS methods were developed and validated for the quantification of ertapenem (Invanz?) in human plasma. Ertapenem is a unique drug in that current dosing recommendations call for a 1 g dose for normal renal function patients, despite body weight. These assays, which involve a protein precipitation followed by liquid–liquid extraction, allow for fast therapeutic drug monitoring of ertapenem in patients, which is especially useful in special populations. Both methods were sufficient to baseline resolve meropenem (internal standard) and ertapenem, and were validated over 3 days using a six‐point calibration curve (0.5–50 µg/mL). Validation was collected using four different points on the calibrations curve yielding acceptable precision (<15% inter‐day and intra‐day; <20% for lower limit of quantitation, LLOQ) as well as accuracy (<15% inter‐day and intra‐day; <20% for LLOQ). The lower limit of detection (LOD) was determined to be 0.1 and 0.05 µg/mL for the HPLC‐UV and LC‐MS methods, respectively. The developed HPLC‐UV and LC‐MS methods for ertapenem quantification are fast, accurate and reproducible over the calibration range and can be used to determine ertapenem plasma concentrations for monitoring clinical efficacy. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

14.
Five ingredients (caffeine, l ‐arginine, creatine, β‐alanine, and 1,3‐dimethylamylamine) from a workout supplement were separated by HPLC with UV detection and LC–MS using an analytical column based on silica hydride operating in aqueous normal phase mode. While RP methods were observed to be inadequate for the analysis due to low retention, aqueous normal phase chromatography was able to readily retain and resolve the analytes. After method development on the HPLC–UV system, the conditions were successfully transferred to an LC–MS system for analysis. Based on calibration curve data, estimates of 63.5, 380.3, and 13.1 mg/serving (5.50 g) were obtained for creatine, l ‐arginine, and 1,3‐dimethylamylamine, respectively. Standard addition data results were compared to those of the calibration curve study, and the two values differed by less than 1% in the case of creatine. The conditions are suitable for further development as a reliable means of quantitating the analytes in workout supplement formulations.  相似文献   

15.
《Analytical letters》2012,45(17):2673-2689
A high-performance liquid chromatography–UV/VIS detection–electrospray ionization single quadrupole mass spectrometry (HPLC–UV/VIS–ESI-MS) method was developed to separate oxidative and photolytic degradation products of aryldiamines, that is, para-phenylenediamine and para-toluenediamine. The separation was performed on a polar modified reversed phase-C18 column which provided superior chromatographic resolution compared to conventional columns. Gradient elution was used with the mobile phases of water and acetonitrile containing 10 mM ammonium acetate. Various compounds including aryldiamines, benzoquinones, aromatic nitro compounds, and azobenzenes were selected for an optimization of the ESI-MS operation and the chromatographic separation conditions. Highly linear calibrations (r2 > 0.999) were achieved for a subset of 5 standard substances. Using analyte-specific UV detection wavelengths, limits of detection and limits of quantitation of these substances ranged from 3.0 to 7.0 µg L?1 and from 10.0 to 23.3 µg L?1, respectively. The analysis of aqueous solutions of para-toluenediamine photolysis products confirmed the performance of the method. Up to 28 chromatographic signals were recorded and the change of their peak heights during the transformation process was monitored for 24 hours. The identities of the compounds were ascertained by means of MS detection correlations between molecular features and the chromatographic retention of the compounds.  相似文献   

16.
A novel HPLC-atmospheric pressure chemical ionization/MS (HPLC-APCI/MS) method was developed for the rapid analysis of selected fatty and resin acids typically present in papermaking process waters. A mixture of palmitic, stearic, oleic, linolenic, and dehydroabietic acids was separated by a commercial HPLC column (a modified stationary C(18) phase) using gradient elution with methanol/0.15% formic acid (pH 2.5) as a mobile phase. The internal standard (myristic acid) method was used to calculate the correlation coefficients and in the quantitation of the results. In the thorough quality parameters measurement, a mixture of these model acids in aqueous media as well as in six different paper machine process waters was quantitatively determined. The measured quality parameters, such as selectivity, linearity, precision, and accuracy, clearly indicated that, compared with traditional gas chromatographic techniques, the simple method developed provided a faster chromatographic analysis with almost real-time monitoring of these acids.  相似文献   

17.
A new method of flaxseed-derived lignan determination was developed using HPLC with high-resolution time-of-flight MS (TOF-MS), optimized, and compared to two existing methods (HPLC/MS/MS and GC/MS). The limits of detection (LODs) for HPLC/TOF-MS (0.002–0.043 pg) were comparable with those of the optimized and improved HPLC/MS/MS (0.001–0.015 pg), whereas the LODs for the optimized GC/MS were higher (0.02–3.0 pg, yet lower than reported before). Using the newly developed detection and separation methods, several key flaxseed sample preparation parameters (including extraction, hydrolysis, and sample purification) were evaluated resulting in the development of efficient protocol for lignan quantification from flaxseed hulls and embryos. The results confirmed the importance of quantification of both aglycones and unhydrolyzed glucosides in order to obtain the total lignan estimates.  相似文献   

18.
This work presents a high-performance liquid chromatography (HPLC) method for the quantitation of glucosamine in chitin. The method includes an acid hydrolysis of chitin. The chromatographic separation is achieved using a Hypersil ODS 5-microm column (250 x 4.6 mm) at 38 degrees C, with precolumn derivatization with 9-fluorenylmethyl-chloroformate and UV detection (lambda = 264 nm). The mobile phase is a mixture of mobile phase A [30 mM ammonium phosphate (pH 6.5) in 15:85 methanol-water (v/v)], mobile phase B [15:85 methanol-water (v/v)], and mobile phase C [90:10 acetonitrile-water (v/v)], with a flow rate of 1.2 mL/min. The HPLC method proposed showed adequate repeatability (relative standard deviation, 5.8%), accuracy (92.7% recovery), and sensitivity, with a detection limit of 2 microg/mL. The method is successfully applied to the quantitation of glucosamine for the determination of the purity of chitin from shrimp waste.  相似文献   

19.
Tandem mass spectrometry (MS/MS) has become a prominent method for screening newborns for diseases such as organic acidemia and fatty acid oxidation defects, although current methods cannot separate acylcarnitine isomers. Accurate determination of dicarboxylic acylcarnitines such as methylmalonylcarnitine and glutarylcarnitine has not been carried out, because obtaining standards of these acylcarnitines is difficult. We attempted the individual determinations of acylcarnitines with isomers and dicarboxylic acylcarnitines by applying high-performance liquid chromatography (HPLC). Chromatographic separation was performed by gradient elution using a mixture of 0.08% aqueous ion-pairing agent and acetonitrile as the mobile phase. Mass transitions of m/z 161.8-->84.8 for carnitine and m/z 164.8-->84.8 for deuterated carnitine were monitored in positive ion electrospray ionization mode. One carnitine and 16 acylcarnitines were quantified. The limit of quantitation (LOQ) was 0.1 micromol/L for methylmalonylcarnitine and 0.05 micromol/L for the other acylcarnitines. Intra-day and inter-day coefficients of variance (CVs) were <8.3% and <8.8%, respectively, for all acylcarnitines in serum, and both were <9.2% in urine. Mean recoveries were >90% for all acylcarnitines. Human samples were quantified by this method. After addition of deuterated acylcarnitines as internal standards, acylcarnitines in serum or urine were extracted using a solid-phase extraction cartridge. In healthy adult individuals, isobutyryl-, 2-methylbutyryl- and isovalerylcarnitine were detected in serum and urine. Dicarboxylic acylcarnitines were detected in urine. High concentrations of methylmalonylcarnitine and propionylcarnitine were found in both the serum and the urine of a patient with methylmalonic acidemia. The described HPLC/MS/MS method could separate most acylcarnitine isomers and quantify them, potentially allowing detailed diagnoses and follow-up treatment for those diseases.  相似文献   

20.
Jana Olšovská 《Talanta》2010,80(5):1849-1147
A new ultra high-performance liquid chromatography method with UV detection was examined for detection and separation of polychlorinated biphenyls. This included optimization of separation conditions for two model mixtures containing seven and fifteen most relevant congeners, comparison of three types of reversed phase sub-2-micron particle sized columns and assessment of system suitability under the optimized conditions. Calibration curves determined in the range from 0.5 to 50.0 μg/mL exhibited correlation coefficients ranging from 0.997 to 0.999. Lower limits of detection ranged from 0.1 to 0.5 ppm. The most efficient Grace C18 column filled with 1.5 μm particles was then tested to separate the complex commercial mixture Delor 103, where the elution order was confirmed by GC-MS. 13 individual congeners were separated and some of the other co-eluting congeners could be resolved using another separation dimension performed with a mass spectrometry detector. The developed method could be directly applied to the separation of less complex mixtures in aqueous sample matrixes, which are used in general for enzyme degradation studies.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号