首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Extraction, pre-concentration and determination of trace amounts of mercury ions from water samples were investigated by magnetic solid phase extraction (MSPE) method using Fe3O4 nanoparticles decorated with polythionine as an adsorbent. A simple chemical synthesis by catalytic reaction of thionine in the presence of FeCl3 and hydrogen peroxide was used for preparation of the magnetic sorbent. Scanning electron microscopy, transmission electron microscopy, energy-dispersive X-ray spectroscopy, vibrating sample magnetometer analysis and Fourier transform infrared spectroscopy were used to characterise the adsorbent. Mercury ions were determined by cold vapour atomic absorption spectrometry. The parameters for MSPE procedure, such as pH of the extraction solution, adsorption time, weight adsorbent, elution conditions (type, concentration and volume of the eluent), volume of the sample solution and effects of coexisting ions were investigated. The obtained optimal conditions were: sample pH of 4; sorbent amount of 4 mg; sorption time of 20 min; elution solvent of HNO3 (0.3 mol L?1)/thiourea (2% w/v) with volume of 2 mL, and breakthrough volume of 400 mL. A good linearity in the concentration range of 0.025–40 µg L?1 (R2 > 0.999) with the pre-concentration factor of 198 was obtained. The limits of detection and quantification were achieved as 0.008 and 0.025 µg L?1, respectively. Furthermore, sea and river water samples were analysed and good recoveries (97.1–99.6%) were obtained.  相似文献   

2.
This study describes the synthesis and application of a magnetic amino‐functionalized hollow silica‐titania microsphere as a new sorbent for magnetic dispersive micro‐solid phase extraction of selected pesticides in coffee bean samples. The sorbent was fully characterized by Fourier‐transform infrared spectroscopy, field emission scanning electron microscopy, transition electron microscopy, energy‐dispersive X‐ray spectroscopy, and vibrating sample magnetometry techniques. Significant extraction parameters affecting the proposed method, such as extraction time, sorbent amount, sample solution pH, salt amount, and desorption conditions (desorption solvent and time) were investigated and optimized. All the figures of merits were validated in coffee bean samples under the matrix‐matched calibration method. Linear dynamic ranges were 5–250 µg/kg with the determination coefficients (R2) > 0.9980. The limits of detection for the pesticides of chlorpyrifos, malathion, hexaconazole, and atrazine were 1.42, 1.43, 1.35, and 1.33 µg/kg, respectively. Finally, the method was successfully applied for the determination of the pesticides in green and roasted coffee bean samples, and the obtained recoveries were in the range of 74–113% for spiked samples. The prepared sorbent could be used for the magnetic dispersive micro‐solid phase extraction of pesticides in the plant‐derived food matrix.  相似文献   

3.
A new type of adsorbent composed of magnetic three‐dimensional graphene coated with silver nanoparticles was synthesized by an electroless technique and used in the magnetic solid‐phase extraction of selected pesticides (fenitrothion, chlorpyrifos, and hexaconazole) before gas chromatography with a micro‐electron capture detector. The adsorbent was characterized using Fourier‐transform infrared spectroscopy, X‐ray diffraction, vibrating sample magnetometry, and field‐emission scanning electron microscopy. The important extraction parameters such as pH, adsorbent dose, extraction time, and desorption conditions were investigated. Under the optimal conditions, the analytical figures of merit were obtained as: linear dynamic range of 0.1–5 ng/g with determination coefficients of 0.991–0.996; limit of detection of 0.07–0.13 ng/g; limit of quantification of 0.242–0.448 ng/g; and the intraday and interday relative standard deviations (= 5 ng/g, = 3) were 3.8–8.7 and 6.6–8.9%, respectively. The developed method was successfully applied for analysis of the selected pesticides in tomato and grape with extraction recoveries in the range of 72.8–109.6%.  相似文献   

4.
In this research, magnetic Fe3O4 nanoparticles were synthesised by co-precipitation method and modified with polythiophene (PT) to produce Fe3O4-PT nanoparticles for preconcentration and determination of cadmium (??) ion followed by electrothermal atomic absorption spectrometry. The results of FT-IR spectroscopy, EDX analysis and SEM images show that Fe3O4-PT nanoparticles were synthesised successfully. Different parameters such as sample pH, amounts of adsorbent, sample volume, extraction time, type and concentration of eluent and desorption time were completely investigated and optimum conditions were selected.

Under the optimum conditions, the calibration curve was linear in the range of 0.01–0.25 µg L?1 of cadmium (??). The relative standard deviation was 4.7% (n = 7, 0.10 µg L?1 Cd2+) and limit of detection was 3.30 ng L?1. The accuracy of the proposed method was verified by the analysis of a certified reference material and spike method. Finally, the proposed method was applied for the determination of ultra-trace levels of cadmium (??) in different water and food samples.  相似文献   

5.
In this study, silica@chitosan-glutaraldehyde (Si@Cs-G) was synthesized as a novel adsorbent for extraction of Penicillin G (PG) from the synthetic and real samples followed by HPLC determination. The synthesized adsorbents were characterized by the scanning electron microscopy (SEM), X-ray diffraction (XRD), fourier transform infrared (FTIR), dynamic light scattering (DLS), transmission electron microscopy (TEM) and nitrogen adsorption–desorption techniques. The factors influencing the extraction efficiency including pH, sorbent dose, extraction time, extraction solvent type and its volume were investigated and optimized.Under the optimal conditions (sorbent dosage: 25 mg, desorption solvent (acetonitrile) with volume of 0.75 mL; pH: 6 and extraction time: 50 min), the Si@Cs-G demonstrated high efficiency and linearity (R2 > 0.999) with the concentration of penicillin G ranging from 1 to 300 μg L−1. Extraction recovery in synthetic samples was 98.977%, with LOD = 0.493 μg L−1, LOQ = 1.638 μg L−1 and RSD < 1.953%. The method was successfully applied for determination of PG in real water samples (tap, river, lake and well water) and wastewater samples (SH and SHB hospital effluent). The obtained relative recoveries were in the range of 91.31% -123.27% with RSD less than 6.34% for all the real samples. The dominant mechanism in the PG adsorption process was involved in the π-π interaction, hydrogen bonding, and electrostatic interaction.  相似文献   

6.
In this work, mesoporous silica (SBA‐15‐NH2) was used as an efficient adsorbent for extraction of chlordiazepoxide from different samples based on dispersive nanomaterial‐ultrasound assisted microextraction followed by high‐performance liquid chromatography. The prepared sorbent was characterized by fourier transform infrared spectroscopy, scanning electron microscopy, low‐angle X‐ray diffraction, thermal analysis, and N2 adsorption‐desorption surface area measurement. Several variables affecting the extraction efficiency of the chlordiazepoxide, including the amounts of adsorbent, time of adsorption, pH and volume of desorption solvent were optimized by central composite design combined with desirability function. The values of variables were set as 10 mg of SBA‐15‐NH2, 15 min adsorption time, pH = 7.3 and 1 mL methanol. The linear response (0.998) was obtained in the range of 0.006–10 µgmL?1 with detection limit 0.0014 µg/mL and extraction recovery was in the range of 91–96% with relative standard deviation < 6%.  相似文献   

7.
《Analytical letters》2012,45(14):1971-1979
In this paper, bamboo charcoal was successfully developed for the solid-phase extraction adsorbent for the determination of six organophosphorus pesticides in water samples. After the bamboo charcoal was pretreated and packed in the solid-phase extraction cartridge, the organophosphorus pesticides in water samples were carried out the solid-phase extraction. To establish a perfect solid-phase extraction procedure, the experimental conditions including the eluent, eluent volume, pH of the sample, flow rate of the sample, and loading volume of the sample were all investigated. When 100 mL water samples in the pH range of 6–7 were loaded with the flow rate of 2.5 mL · min?1 and then eluted with 10 mL acetonitrile, the proposed extraction method was validated by the recovery, correlation coefficient (R2), repeatability (RSD, n = 7) and LODs, which were 69.6–93.4%, 0.9982–0.9998, 2.9–5.6%, and 0.08–1.04 µg · L?1, respectively. Furthermore, the analysis of the tap, snow, and river water samples demonstrated the feasibility of the proposed SPE method for real water samples. Based on the aforementioned factors, it could be concluded that bamboo charcoal was a good solid-phase extraction adsorbent, and this proposed solid-phase extraction method was suitable for the effective enrichment and determination of the organophosphorus pesticides in water samples.  相似文献   

8.

In this paper, a novel pipette tip micro-solid phase extraction based on molecularly imprinted polymer as a selective sorbent was developed and applied for extraction, pre-concentration and high-performance liquid chromatographic determination of trace amounts of malachite green (MG), rhodamine B (RB), methyl orange (MO) and acid red 18 (AR) dyes in seawater samples. Different parameters affecting the extraction efficiency such as type and volume of eluent solvent, sample volume, number of cycles of extraction and desorption, amount of sorbent and pH of the sample solution were evaluated using one-variable-at-a-time and response surface methodology. In order to optimize dyes extraction, seven factors in three levels were used for Box–Behnken experimental design. Under optimum extraction condition, pH of sample solution was 3.1 for MG, 3.0 for RB, 7.1 for MO and 6.1 for AR; volume of eluent solvent (HCl, 0.5 mol L−1) was 200 µL; volume of the sample solution was 10 mL (for MG) and 4 mL (for RB, MO and AR); the concentration of triton X-114 was 0.085 (MG), 0.10 (RB), 0.08 (MO) and 0.075 (AR) % v/v; the number of extraction cycles was 10 (MG), 6 (RB), 5 (MO) and 7 (AR); the number of elution cycles was 10, 6, 5 and 9, respectively, for MG, RB, MO and AR; NaCl concentration was 0.4 mol L−1; and amount of MIP was 2.0 mg for all dyes. The linear range of calibration curves was 0.5–250.0 µg L−1 for malachite green and methyl orange and 0.5–150.0 µg L−1 for both rhodamine B and acid red 18. The detection limits calculated to be 0.083, 0.10, 0.12 and 0.17 µg L−1 for MG, RB, MO and AR, respectively. The developed protocol was successfully used for determination of dyes in seawater of Chabahar Bay. The mean recoveries were ranged between 76.1 and 97.3% by mean relative standard deviations of 1.2–7.1%.

  相似文献   

9.
A magnetite–polypyrrole composite adsorbent was synthesized and applied for the magnetic solid phase extraction of three non-steroidal anti-inflammatory drugs in aqueous solution and systematically investigated using Box–Behnken design. The synthesized composite adsorbent was characterized using Fourier-transform infrared spectroscopy, transmission electron microscopy, the Brunauer–Emmett–Teller method, vibrating sample magnetometry, and X-ray diffraction. The material was successfully modeled by Box–Behnken design (R2?=?0.94–0.98, p value: <0.001%) by monitoring the extraction efficiencies of naproxen, diclofenac sodium, and mefenamic acid. The analytes were determined using high-performance liquid chromatography with ultraviolet detection. The polymerization time was found to be the most significant factor, followed by amount of oxidant and monomer in the synthesis of the composite with a fixed Fe3O4 mass. Box–Behnken design was employed for the optimization of four parameters affecting the magnetic solid phase extraction: sample pH, salt addition, adsorption, and desorption time (R2?=?0.88–0.94). The optimized conditions for the procedure were validated, providing low detection limits (0.9–3.5?µg?L?1) with good reproducibility (<7.16% relative standard deviation) and excellent recoveries (97.87–100.49%) for tap, river, and wastewater samples. The synthesized adsorbent demonstrated good adsorption efficiency for the simultaneous determination of the non-steroidal anti-inflammatory drug residues.  相似文献   

10.
ABSTRACT

In this work, a novel layered sorbent for microextraction by packed sorbent (MEPS) was introduced, which has been prepared by coating graphene oxide/polyamide (GO/PA) nanocomposite (NC) onto cellulose paper through solvent exchange method. Scanning electron microscopy (SEM) was applied to investigate the surface characteristic and morphology of PA and GO/PA NC coated on cellulose paper. The prepared MEPS device was used for extraction of organophosphorous pesticides (OPPs) including chlorpyrifos, fenthion, fenithrothion, ethion, edifenphos and phosalone in environmental aqueous samples followed by detection using gas chromatography-flame ionisation detector (GC-FID). Important parameters affecting the MEPS method including pH of sample solution, extraction draw-discard cycles, sorbent layers, desorption solvent volume and desorption draw-eject number were studied and optimised using central composite design (CCD). Based on the method validation, limits of detection (LODs) were in the range of 0.2–1 µg L?1. The calibration graphs for chlorpyrifos, fenthion and edifenphos are linear in the concentration range of 1 to 500 µg L?1; for ethion and phosalone are linear in the range of 1–1000 µg L?1 and for fenithrothion is linear in the range of 3–1000 µg L?1. The method precision (RSD %) with six replicates determinations was in the range of 3 to 9.4 % and 3.9 to 11.9% for distilled water and spiked river water sample, respectively, at the concentration level of 300 µg L?1 . The developed method was applied successfully to determine OPP compounds in river, dam and tap water samples; accordingly, the relative recoveries (RR%) were obtained in the range of 77.8 to 113.3%.  相似文献   

11.
Using commercially available melamine and formaldehyde as the starting materials, a magnetic mesoporous melamine–formaldehyde resin (MMF@Fe3O4) possessing large surface area was prepared via a simple method and could be used as an efficient adsorbent for magnetic solid‐phase extraction. Compared with the traditional synthetic methods of MMF@Fe3O4, this approach is easily operated under mild conditions, is time‐saving and environmentally friendly, and can produce the material in high yields. The as‐prepared MMF@Fe3O4 possesses good adsorption capacity and selectivity for silver ions. The affecting factors such as pH, amount of MMF@Fe3O4, extraction time, desorption solvent, eluent concentration and sample volume were systematically investigated and optimized. Under the optimized conditions, the material exhibited a good response to silver ions at concentrations in the range 2.0–200 μg l?1 with good linearity (r2 = 0.9982), while the limit of detection was found to be 0.12 μg l?1. The material was successfully applied to the determination of silver in a variety of water samples.  相似文献   

12.
A method for analysis of 20 commonly used pesticides in surface water based on solid-phase extraction and gas chromatography-mass spectrometry was proposed. During method development the key parameters that can affect SPE extraction and determination such as selection of efficient SPE sorbent, pH of water sample, type and volume of elution solvent, breakthrough volume and matrix effects were investigated. The method was validated using spring water spiked with appropriate concentration of pesticides. The obtained correlation coefficients were in range 0.9972–1.000, limits of detection (LOD) were 0.001–0.5?µg?L?1 and the limits of quantification (LOQ) were 0.005–1?µg?L?1 depending on a pesticide. Much higher LOD (20?µg?L?1) and LOQ (50?µg?L?1) values were obtained for bentazone. The influence of matrix was assessed using real water samples spiked with appropriate concentration of pesticide standards solution. Both signal enhancement and suppression were observed, depending on a pesticide, therefore standard addition method was used for pesticides determination. The developed method was applied on real water samples taken in close vicinity of agricultural fields. Many of the targeted pesticides were found in the samples and the results are presented in this article.  相似文献   

13.
A simple, rapid and efficient method, dispersive liquid–liquid microextraction (DLLME) in conjunction with high-performance liquid chromatography (HPLC), has been developed for the determination of three carbamate pesticides (methomyl, carbofuran and carbaryl) in water samples. In this extraction process, a mixture of 35 µL chlorobenzene (extraction solvent) and 1.0 mL acetonitrile (disperser solvent) was rapidly injected into the 5.0 mL aqueous sample containing the analytes. After centrifuging (5 min at 4000 rpm), the fine droplets of chlorobenzene were sedimented in the bottom of the conical test tube. Sedimented phase (20 µL) was injected into the HPLC for analysis. Some important parameters, such as kind and volume of extraction and disperser solvent, extraction time and salt addition were investigated and optimised. Under the optimum extraction condition, the enrichment factors and extraction recoveries ranged from 148% to 189% and 74.2% to 94.4%, respectively. The methods yielded a linear range in the concentration from 1 to 1000 µg L?1 for carbofuran and carbaryl, 5 to 1000 µg L?1 for methomyl, and the limits of detection were 0.5, 0.9 and 0.1 µg L?1, respectively. The relative standard deviations (RSD) for the extraction of 500 µg L?1 carbamate pesticides were in the range of 1.8–4.6% (n = 6). This method could be successfully applied for the determination of carbamate pesticides in tap water, river water and rain water.  相似文献   

14.

In this research, electrospun polycaprolactam nanofibers were collected on a fine stainless steel mesh sheet without a binder, and a layer of conductive polyaniline was chemically deposited on the nanofibers. The polyaniline immobilized on the polycaprolactam nanofibers provided high electrical conductivity, acceptable mechanical stability, and a large surface area. This assembly was then used as a working electrode in electrochemically controlled solid-phase microextraction (EC-SPME), a fast and environmentally friendly method. The polymer layers were characterized by SEM and FTIR techniques. Significant factors affecting the EC-SPME efficiency were investigated, including the desorption conditions, the sorbent used, the pH of the sample solution, the extraction voltage, the extraction time, and the ionic strength. Under the optimum conditions, the limits of detection and quantification for the target analytes were 0.9–1.8 μg L−1 and 3.0–6.1 μg L−1, respectively. The linear dynamic range was 5–2000 μg L−1, with R2 > 0.993. The method was coupled with HPLC analysis and applied to the determination of angiotensin ΙΙ receptor antagonists (ARA-ΙΙs) in human plasma, and relative recoveries of 91.1–104.3% with RSDs of ≤8.3% were obtained.

  相似文献   

15.
In this work, magnetic solid-phase extraction based on sodium dodecyl sulfate-coated Fe3O4 nanoparticles has been successfully applied for extraction and preconcentration of trace amounts of nystatin from water and vaccine samples prior to high-performance liquid chromatography–ultraviolet detection. Various experimental parameters affecting extraction and recovery of the analyte, such as the amount of sodium dodecyl sulfate, pH of the sample solution, salt concentration, extraction time, sample volume and desorption conditions, were systematically studied and optimized. Under optimized conditions, nystatin was quantitatively extracted. Proper linear range with good coefficient of determination, (R 2 > 0.99) and limit of detection and quantification (based on signal-to-noise ratios of 3 and 10) of 2.0 and 5.0 µg L?1, over the investigated concentration range (5–700 µg L?1), were obtained, respectively. The intra-day and inter-day relative standard deviations at 50 µg L?1 level of NYS were 1.4 and 4.5% based on six replicate determinations. The accuracy of the method was evaluated by recovery measurements on spiked samples. Suitable recoveries of 96–102 and 26–44% were achieved (at spiked levels of 50, 300 and 500 µg L?1) for water and vaccine samples, respectively.  相似文献   

16.
A new magnetic adsorbent, 3-mercaptopropionic acid coated 3-aminopropyl triethoxysilane modified Fe3O4 nanoparticle, was synthesised and used for the extraction and preconcentration of arsenic ions in aqueous solutions followed by electrothermal atomic absorption spectrometric determination. The adsorbent was characterised by TEM, SEM, XRD and FT-IR techniques and the method used the unique properties of magnetic nanoparticles, namely, high surface area and superparamagnetism which gave it the advantages of high extraction capacity, fast separation and low adsorbent consumption. Different parameters affecting extraction efficiency of the analyte including pH value, sample volume, adsorbent amount, extraction time and desorption conditions were investigated and optimised. Under the optimum conditions, wide linear range of 30–25,000 ng L?1 and low detection limit of 10 ng L?1 were obtained. The interday and intraday precisions (as RSD%) for five replicates determination of 50 and 25,000 ng L?1 of arsenic ions were in the range of 2.3–3.2%. Furthermore, no significant interference was observed in the presence of coexisting ions and high preconcentration factor of 198 was obtained. The adsorption isotherm followed Langmuir model and its kinetic was second-order. The accuracy of the method was validated by analysing certi?ed reference materials for water and rice with satisfactory recoveries. Finally, the proposed method was successfully applied for the determination of ultra-trace amounts of arsenic in rice and water samples.  相似文献   

17.
In the present study, ionic liquid-modified silica-coated magnetic nanoparticles (MNPs) were synthesised and applied as a new anion-exchange sorbent for extraction and determination of Cr(VI) followed by inductively coupled plasma atomic emission spectrometry. The characterisation of MNPs was carried out by scanning electron microscope, Fourier transform infrared and vibrating sample magnetometer. Experimental design and response surface methodology were used for optimisation of different parameters which affect extraction efficiency of Cr(VI). Under the optimised conditions, extraction recoveries within the range of 25–33% with relative standard deviations (RSD%, n = 4) within the range of 3.0–5.0% were obtained. The limit of detection was found to be 0.1 µg L?1. The linearity was studied in the range of 0.5-200 µg L?1 with the determination coefficient of 0.9958. Also, calculated Errors% for determination of Cr(VI) in the range of 5-15 depict that the method offers acceptable accuracy for analysis of Cr(VI). The method was successfully applied for extraction and determination of Cr(VI) selectively in some tannery waste water samples.  相似文献   

18.
Dispersive liquid–liquid microextraction (DLLME) coupled with gas chromatography–electron capture detection (GC–ECD), has been developed for the extraction and determination of 14 organochlorine pesticides (hexachlorocyclohexanes (α-HCH, β-HCH and δ-HCH), Lindane (γ-HCH), Aldrin, Dieldrin, Endrin, Heptachlor, Heptachlor epoxide, α-Chlordane, β-Chlordane and p,p′-DDT, p,p′-DDD, p,p′-DDE) in river water samples. Factors relevant to the microextraction efficiency, such as the kind of extraction and disperser solvent, their volume and the salt effect was investigated and optimised. In this method the appropriate mixture of extraction solvent (13.5 µL carbon disulphide) and disperser solvent (0.50 mL acetone) were rapidly injected into the aqueous sample by syringe. The values of the detection limit of the method were in the range of 0.05–0.001 µg L?1, while the relative standard deviations for five replicates varied from 2.7 to 9.3%. A good linearity (0.9894 ≤ r 2 ≤ 0.9998) and a broad linear range (0.01–200 µg L?1) were obtained. The method exhibited enrichment factors ranging from 647 to 923, at room temperature. The relative standard deviations varied from 2.7 to 9.3% (n = 5). The relative recoveries of each pesticide from water samples at spiking levels of 2.00 and 10.0 µg L?1 were 88.0–111.0% and 95.8–104.1%, respectively. Finally, the proposed method was successfully utilised for the preconcentration and determination of the organochlorine pesticides in the Jajrood River water samples.  相似文献   

19.
This study reports a deep eutectic solvent based dispersive liquid-liquid microextraction (DES-DLLME) to extract aromatic amines (4-chloroaniline, 3-nitroaniline, 2-naphtylamine) in environmental water samples before their HPLC-UV determination. The hydrophobic deep eutectic solvent (DES) was prepared by mixing bis(2-ethylhexyl) phosphate (BEHP) as a hydrogen bond acceptor and phenol as a hydrogen bond donor. Affecting factors on the extraction of the aromatic amines were investigated and optimized. Optimum conditions were: DES type: BHHP-Ph ratio: 1 to 2; pH of solution: 8.0; DES volume: 80 µL, salt amount: 10% (w/v). Under optimum conditions, the developed method showed a wide linear range of 0.2–200 µg L?1 (R2 ≥ 0.99) with satisfactory recoveries (≥90.0%). The limit of detections (LODs) and limit of quantifications (LOQs) were in the range of 0.07–0.17 µg L?1 and 0.2–0.5 µg L?1, respectively. The enrichment factors were 170, 180 and 190 for 4-chloroaninile, 3-nitroaniline, 2-naphtylamine, respectively. Based on obtained results, the proposed method is straightforward, efficient, sensitive, and eco-friendly for the extracting and determining of the aromatic amines in environmental water samples.  相似文献   

20.
The monitoring of the heavy metal pollution in wastewater is increasingly becoming a crucial global issue since they tend to accumulate in food chains and can cause many biological abnormalities. In this work, it was developed a novel lead ion-imprinted polymer (IIP) using sodium dodecyl sulphate (SDS) as a second template to be used as adsorbent in solid phase extraction (SPE) for determination of lead from wastewater samples by UV–vis spectrophotometry. The polymer called IIP–SDS was synthesised by a double-imprinting process with lead (template) and SDS (template). IIP–SDS was characterised by infrared spectroscopy Fourier transform infrared spectroscopy, thermogravimetric analysis and scanning electron microscopy. IIP–SDS showed good recovery for lead (around 82.0%), while the IIP (only lead as template) was 72.2% and non-IIP was 44.9%. Thus, the double-imprinting process for the preconcentration of Pb2+ proved to be a more adequate methodology than IIP with a single template. The optimised parameters of sample preparation were washing solvent (2.0 mL of tetrahydrofuran), type and volume of eluent (5 mL of 1 mol L?1 hydrochloric acid), sample amount (30 mL of water spiked with 10.0 µg mL?1), amount of IIP–SDS (400 mg) and sample pH (pH = 4.5). Linearity ranged from 10 to 125 µg L?1 with r > 0.992. The limit of detection and quantification were 6.3 and 10 µg L?1, respectively. The precision (relative standard deviation, %) and accuracy (relative error, %) were lower than 15%. Finally, IIP–SDS may be an alternative and effective adsorbent for SPE procedures in monitoring of wastewater samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号