首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到17条相似文献,搜索用时 109 毫秒
1.
 采用新型荧光试剂1,2-苯并-3,4-二氢咔唑-9-乙酸(BCAA)为柱前衍生化试剂,在Hypersil BDS-C18色谱柱上,通过梯度洗脱对12种游离脂肪胺进行了分离和在线质谱定性。以乙腈为溶剂,1-乙基-3-(3-二甲氨基丙基)环己碳二亚胺(EDAC)为缩合剂,在50 ℃条件下衍生反应15 min后获得稳定的荧光产物。激发波长和发射波长分别为333 nm和390 nm。采用大气压化学电离源(APCI)的正离子模式,实现了土壤和污水中脂肪胺的定性及其含量的测定。脂肪胺的线性相关系数大于0.9993,检测限为12~28 fmol。  相似文献   

2.
利用新型荧光试剂1,2-苯并-3,4-二氢咔唑-9-异丙基氯甲酸酯(BCIC)作为柱前衍生化试剂,在乙腈中,以硼酸钠缓冲液(pH 9)为催化剂,40 ℃下衍生反应10 min后获得稳定的荧光产物.在Eclipse XDB-C8色谱柱上,通过梯度洗脱对12种游离脂肪胺进行了分离和在线质谱定性.激发和发射波长分别为λex=333 nm,λem=390 nm.采用大气压化学电离源(APCI)正离子模式,实现了污水中脂肪胺的定性及相应含量测定.脂肪胺的线性回归系数大于0.9996,检出限在10.57~37.83 fmol.  相似文献   

3.
采用新型荧光衍生试剂2-(9-吖啶酮)-乙酸(AAA)进行柱前衍生并经荧光检测对脂肪胺进行了高效液相色谱(HPLC)分离和在线质谱定性.衍生物荧光激发和发射波长为λex=404nm,λem=440nm.30℃下在乙腈溶剂中用N-乙基-N′-[(3-二甲氨基)丙基]碳二亚胺盐酸盐(EDC)做催化剂,衍生反应20min后获得稳定的荧光产物.在HypersilBDSC18(4.6mm×100mm,5μm)色谱柱上,采用梯度洗脱对12种脂肪胺衍生物进行了优化分离.采用大气压化学电离源(APCISource)正离子模式进行在线柱后质谱定性,实现了各种脂肪胺衍生物的快速、准确测定.该方法具有良好的重现性,多数脂肪胺的线性回归系数大于0.9996,检测限为12.09~25.52fmol.  相似文献   

4.
利用新型荧光试剂1,2-苯并-3,4-二氢咔唑-9-乙基氯甲酸酯(BCEOC)作为柱前衍生化试剂,在EclipseXDB-C8色谱柱上,梯度洗脱对12种游离脂肪胺进行了优化分离。40℃下在乙腈溶剂中以硼酸盐缓冲溶液作催化剂,衍生反应10min后获得稳定的荧光产物。激发和发射波长分别为λex=333nm,λem=390nm。采用大气压化学电离源(APCI)正离子模式,实现了土壤和造纸污水中脂肪胺的定性测定。采用荧光法进行分析物的定量测定。多数脂肪胺的线性回归系数大于0.999,检出限在18.65~38.82×10-15mol。方法具有稳定良好的重现性,对实际样品测定结果满意。  相似文献   

5.
柱前衍生-高效液相色谱分离测定及质谱鉴定脂肪胺   总被引:1,自引:0,他引:1  
采用新型荧光衍生试剂2-(2-苯基-1-氢-菲[9,10-d]咪唑)-乙酸(PPIA)进行柱前衍生,经荧光检测实现了脂肪胺的高效液相色谱(HPLC)分离测定及柱后质谱鉴定。60℃下在乙腈溶剂中用N-乙基-N′-[(3-二甲氨基)丙基]碳二亚胺盐酸盐(EDC)做缩合剂,衍生反应15min可获得稳定的荧光产物。脂肪胺衍生物荧光检测波长为380nm(激发波长为260nm)。在EclipseXDB-C8色谱柱上,采用梯度洗脱对12种脂肪胺衍生物进行了优化分离,测定了造纸厂废水、大鼠端脑和酸奶中脂肪胺的含量。经柱后在线质谱大气压化学电离源(APCISource)正离子模式实现了各种脂肪胺衍生物的质谱鉴定,借助对活性中间体的质谱解析确定了衍生反应的反应机理。该方法具有良好的重现性和回收率,多数脂肪胺的线性回归系数大于0.9996;检出限为3.1~18fmol(S/N=3∶1)。  相似文献   

6.
利用新型荧光试剂2-(2-(10-蒽基)-苯并咪唑)-乙酸(ABIA)为柱前衍生化试剂,在Akasil-C18色谱柱上,通过梯度洗脱对12种游离脂肪胺进行了分离和在线质谱定性。以乙腈为溶剂,N-乙基-N′-[(3-二甲氨基)丙基]碳二亚胺盐酸盐(EDC)为缩合剂,在50℃条件下衍生反应20 min后获得稳定的荧光产物。激发波长和发射波长分别为260 nm和430 nm,采用大气压化学电离源(APCI)的正离子模式,实现了土壤中脂肪胺的定性及其含量的测定。脂肪胺的线性相关系数大于0.9990,检出限为11.72~25.63 fmol。  相似文献   

7.
利用新型荧光试剂4-(1H-菲并[9,10-d]咪唑-2-)苯甲酸(PIBA)进行柱前衍生并经荧光检测对脂肪胺进行了高效液相色谱(HPLC)分离和在线质谱定性。激发和发射波长分别为ex=261nm,em=443nm。80℃下在吡啶溶剂中用N-乙基-N’-[(3-二甲氨基)丙基]碳二亚胺盐酸盐(EDC)做催化剂,衍生反应10min后获得稳定的荧光产物。在EclipseXDB-C8色谱柱(4.6150mm,5mm)上,梯度洗脱对12种游离脂肪胺衍生物进行了优化分离。采用大气压化学电离源(APCI)正离子模式,实现了各种脂肪胺衍生物的测定。多数脂肪胺的线性回归系数大于0.9999,检测限为10.5~53.4fmol。  相似文献   

8.
采用新型荧光衍生试剂2-(11H-苯[a]咔唑)-乙酸(BCA)进行柱前衍生并经荧光检测对脂肪胺进行高效液相色谱(HPLC)分离和质谱定性.衍生物荧光激发和发射波长为λex=285 nm,λem=384 nm.60 ℃下在乙腈溶剂中用N-乙基-N′-[(3-二甲氨基)丙基]碳二亚胺盐酸盐(EDC)作催化剂, 衍生反应15 min后获得稳定的荧光产物.在Hypersil BDS C18 (4.0 mm×200 mm, 10 μm) 色谱柱上, 采用梯度洗脱对12种脂肪胺衍生物进行了优化分离.采用大气压化学电离源(APCI Source)正离子模式进行质谱定性, 实现了各种脂肪胺衍生物的快速、准确测定.脂肪胺的线性回归系数不小于0.999 8 , 检出限(S/N=3)为5.73 ~31.3 fmol.  相似文献   

9.
含氮杂环光致发光分子经柱前衍生化,采用荧光检测及柱后在线质谱鉴定对废水中胺类化合物进行了测定.衍生物荧光激发和发射波长分别为λex=275 nm,λem=380 nm.在pH 8.0的硼酸钠缓冲液中,于40 ℃下衍生反应40 min后获得稳定的荧光产物.在Hypersil BDS C18柱上,采用梯度洗脱对5种芳香胺衍生物进行了优化分离.采用大气压化学电离源(APCI Source)正离子模式进行在线的柱后质谱定性,实现了5种芳香胺衍生物的快速、准确测定.方法具有良好的重现性,线性回归系数大于0.9998,检出限在71~81 fmol水平.  相似文献   

10.
含氮类荧光试剂2-(11H-苯[a]咔唑)乙基氯甲酸酯(BCEC-Cl)经柱前衍生处理后,采用荧光检测及柱后在线质谱鉴定对食品中胺类化合物进行了测定。标记反应在pH9的硼酸缓冲液中进行,3min后获得稳定的荧光产物。衍生物于λex=279nm激发条件下产生强烈荧光,其发射波长在λem=380nm处。产物的分离在EclipseXDB-C8色谱柱(150mm×4.6mm,5μm)上进行,采用梯度洗脱对12种脂肪胺衍生物进行了优化分离。采用大气压化学电离源(APCISource)正离子模式进行在线的柱后质谱鉴定,实现了多种脂肪胺衍生物的快速、准确测定。建立的方法具有良好的重现性,回归系数大于0.9996,检出限为1.8~14fmol。  相似文献   

11.
12.
采用3种不同衍生方法对胺类化合物进行标记,比较衍生效率的差别,给出最优方法:5-(2-羟乙基)-(苯并吖啶酮与N,N-羰基双咪唑(CDI)缩合形成的双敏感探针2-(苯并吖啶酮)-乙基咪唑酸酯(BAEIC)与胺的衍生效率最高,产物稳定。BAEIC在N,N-二甲基甲酰胺(DMF)溶剂中以4-二甲氨基吡啶(DMAP)为催化剂,在80℃条件下与胺反应生成的亲核取代物,不仅表现出强烈的荧光,同时具有很强的质谱离子化能力。估算了衍生物在乙腈和甲醇水溶液中百分离子化值δ在5.62%~58.08%和2.14%~56.58%范围内。本方法具有良好的重现性,激发和发射波长为λex/λem=280/510nm,荧光检出限为0.12~0.59μg/L(8.6~79fmol);在线APCI-MS检出限为1.9~14μg/L(544~825fmol)。  相似文献   

13.
Laser-induced acoustic desorption (LIAD) was successfully coupled to a conventional atmospheric pressure chemical ionization (APCI) source in a commercial linear quadrupole ion trap mass spectrometer (LQIT). Model compounds representing a wide variety of different types, including basic nitrogen and oxygen compounds, aromatic and aliphatic compounds, as well as unsaturated and saturated hydrocarbons, were tested separately and as a mixture. These model compounds were successfully evaporated into the gas phase by using LIAD and then ionized by using APCI with different reagents. From the four APCI reagent systems tested, neat carbon disulfide provided the best results. The mixture of methanol and water produced primarily protonated molecules, as expected. However, only the most basic compounds yielded ions under these conditions. In sharp contrast, using APCI with either neat benzene or neat carbon disulfide as the reagent resulted in the ionization of all the analytes studied to predominantly yield stable molecular ions. Benzene yielded a larger fraction of protonated molecules than carbon disulfide, which is a disadvantage. A similar but minor amount of fragmentation was observed for these two reagents. When the experiment was performed without a liquid reagent (nitrogen gas was the reagent), more fragmentation was observed. Analysis of a known mixture as well as a petroleum cut was also carried out. In summary, the new experiment presented here allows the evaporation of thermally labile compounds, both polar and nonpolar, without dissociation or aggregation, and their ionization to predominantly form stable molecular ions.  相似文献   

14.
表面解吸常压化学电离源的研制及应用   总被引:10,自引:0,他引:10  
根据表面解吸常压化学电离源(SDAPCI)对表面痕量待测物进行常压解吸化学电离的原理,自行研制了SDAPCI电离源及其与线性离子阱(LTQ)质谱仪的接口,成功地在LTQ上实现了表面解吸常压化学电离。此方法无需样品预处理,直接利用电晕放电产生的H3O 在常压下对待测样品进行表面解吸化学电离,避免了甲醇等有毒试剂的使用。在优化的仪器参数条件下,分别用正/负离子模式成功地检测了片剂药品中的氯雷他定、乙酰氨基酚等活性成分和其它不同表面上TNT、氨基酸和多肽等物质,对这些常见物质的检出限不高于10pg/cm2。采用氩气作为电离试剂,观测到乙酰氨基酚、多肽等物质形成的自由基阳离子,提出了在氩气氛围中获得自由基阳离子的可能机理。实验表明SDAPCI具有灵敏度较高,选择性好,适用范围宽等特点,适合用于药品、食品等非破坏、无污染检测以及对复杂基体物质进行快速现场分析。  相似文献   

15.
表面解吸化学电离质谱法快速检测蔬菜中痕量氨基甲酸酯   总被引:1,自引:0,他引:1  
采用自行研制的表面解吸常压化学电离源(SDAPCI),首次在无需样品预处理的前提下用质谱法直接测定了多种蔬菜表面残留的痕量氨基甲酸酯,并用串联质谱对所获得的不同氨基甲酸酯农药的离子进行了结构鉴定,排除了检测结果的假阳性。该方法对待测样品无污染,方法检测限低于10-14g/cm2,单个样品的测定时间平均少于1 s,特别适合于对批量样品进行快速检测。  相似文献   

16.
微量果汁中痕量乐果的快速质谱检测   总被引:3,自引:1,他引:3  
利用自行研制的纳升级微量取样器,建立了在无需样品预处理的前提下,对纳升级的市售果汁中痕量残留农药乐果进行快速分析的表面解吸常压化学电离质谱方法。实验结果表明,微量取样器的最小取样量为0.11nL,果汁样品中的乐果在0.0010~10.0mg/kg浓度范围内线性关系较好,相关系数为0.988,回收率为80.5%~120.6%,相对标准偏差为8.4%~17.2%,检出限可达1.2×10-11mg/kg。  相似文献   

17.
Efforts to analyze trace levels of cyclic peroxides by liquid chromatography/mass spectrometry gave evidence that acetonitrile suppressed ion formation. Further investigations extended this discovery to ketones, linear peroxides, esters, and possibly many other types of compounds, including triazole and menadione. Direct ionization suppression caused by acetonitrile was observed for multiple adduct types in both electrospray ionization and atmospheric pressure chemical ionization. The addition of only 2% acetonitrile significantly decreased the sensitivity of analyte response. Efforts to identify the mechanism were made using various nitriles. The ion suppression was reduced by substitution of an acetonitrile hydrogen with an electron-withdrawing group, but was exacerbated by electron-donating or steric groups adjacent to the nitrile. Although current theory does not explain this phenomenon, we propose that polar interactions between the various functionalities and the nitrile may be forming neutral aggregates that manifest as ionization suppression.
Graphical Abstract ?
  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号