1.
The variability associated with the aflatoxin test procedure used to estimate aflatoxin levels in bulk shipments of hazelnuts was investigated. Sixteen 10 kg samples of shelled hazelnuts were taken from each of 20 lots that were suspected of aflatoxin contamination. The total variance associated with testing shelled hazelnuts was estimated and partitioned into sampling, sample preparation, and analytical variance components. Each variance component increased as aflatoxin concentration (either B1 or total) increased. With the use of regression analysis, mathematical expressions were developed to model the relationship between aflatoxin concentration and the total, sampling, sample preparation, and analytical variances. The expressions for these relationships were used to estimate the variance for any sample size, subsample size, and number of analyses for a specific aflatoxin concentration. The sampling, sample preparation, and analytical variances associated with estimating aflatoxin in a hazelnut lot at a total aflatoxin level of 10 ng/g and using a 10 kg sample, a 50 g subsample, dry comminution with a Robot Coupe mill, and a high-performance liquid chromatographic analytical method are 174.40, 0.74, and 0.27, respectively. The sampling, sample preparation, and analytical steps of the aflatoxin test procedure accounted for 99.4, 0.4, and 0.2% of the total variability, respectively.  相似文献   

2.
The aim of this research work was the evaluation of stir-bar sorptive extraction (SBSE) in combination with an in situ derivatization to determine parabens (methylparaben, isopropylparaben, n-propylparaben, butylparaben and benzylparaben), triclosan and methyltriclosan in soil samples. This is the first time that this approach has been applied to the determination of these compounds in soil samples, providing important advantages over conventional extraction techniques, such as minimization of sampling handling, complete elimination of the use of organic solvents and simplification of the analytical procedure with reduced time consumption. The enriched target analytes were desorbed thermally using a thermodesorption system coupled to a gas chromatograph and a mass spectrometer. The optimized derivatization and SBSE extraction conditions, as well as the analytical characteristics of the method were obtained using spiked soil samples. The proposed methodology proved to be easy to use and sensitive, with limits of detection between 80 ng/kg and 1.06 μg/kg, and reproducibility values below 13%. The accuracy of the method was evaluated at two concentration levels, obtaining apparent recoveries between 91% and 110%. The matrix composition significantly influenced the extraction procedure, and a need to adopt a standard additions protocol is apparent. The analytes assayed were determined successfully in different environmental soil samples.  相似文献   

3.
The potential of solid phase microextraction (SPME) for the determination of the soil fumigants 1,3-dichloropropene (1,3-DCP) and methyl isothiocyanate (MITC) in environmental samples such as soil and water samples has been investigated. Direct immersion SPME followed by GC/ECD/NPD analysis allowed the rapid determination of the two fumigants in water samples, with very little sample manipulation, giving an LOD of 0.5 microg L(-1). Precision, calculated as relative standard deviation (RSD) for six replicates at three concentration levels, was found to be lower than 20% at the concentration levels tested. For the analysis of soil samples, headspace (HS)-SPME combined with GC/ECD/NPD analysis has been applied. Quantification using matrix-matched calibration curves allowed determination of both analytes (MITC and 1-3-DCP) with a LOD of 0.1 microg kg(-1) (RSD < 10%) for the two concentration levels assayed (0.02 and 0.2 mg kg(-1)). The HS-SPME procedure developed in this paper was applied to soil samples from experimental green house plots treated with metham-Na, a soil disinfestation agent that decomposes in soil to MITC. The absence of sample manipulation as well as the low solvent consumption in SPME methodology are among the main advantages of this analytical approach.  相似文献   

4.
The determination of organochlorine pesticides in water samples, which are harmful to humans, is very important for environmental risk assessment. Based on the excellent adsorption properties of graphene, an SPE coupled with GC–MS method for the monitoring of organochlorines (four hexachlorcyclohexanes and four dichlorodiphenyltrichloroethanes) was developed. Owing to the hydrophobic interaction and π–π stacking interaction between the analytes and graphene, the analytes quantitatively adsorbed onto the graphene‐based SPE cartridge were eluted by ethyl acetate for analysis. Several parameters influencing the analytical performance, such as the kind of elution, sample volume, reusability of the cartridge, have been investigated in detail. Under the optimal conditions, detection of limits of 1.95–9.38 ng/L, recoveries of 83.9–107.3% at two spiked concentration levels (0.1 and 10 ng/mL) and RSDs in the range of 2.9–7.4% for real water samples were obtained for all the analytes. This work reveals the great potential of graphene in sample preparation procedures.  相似文献   

5.
In this work, the simple analytical method for the determination of four fluoroquinolone antibiotics: ciprofloxacin, enrofloxacin, norfloxacin and danofloxacin, in environmental surface water samples is described. Sample pretreatment step was performed by the application of a technique based on supported liquid membrane extraction with the configuration of single hollow fiber (HF-SLM). The HPLC system with diode array detection was used for final analysis of studied analytes. Various parameters affecting the extraction efficiency during HF-SLM enrichment, such as type of membrane diluent, pH of donor (sample) and acceptor phases, as well as an enrichment time and salt content of sample were studied. Using the presented hollow-fiber extraction high recovery (70–80%) was achieved. It gave enrichment factor above 100. The detection limits in surface water samples, for the four target antibiotics, were at range 0.01–0.02 μg/l, when 10 ml samples were processed. The obtained results demonstrate the applicability of presented method for the selective extraction of fluoroquinolones in environmental water samples at ultratrace level. Errors, expressed as relative standard deviation (RSD) were below 8%, for all tested concentration levels.  相似文献   

6.
Sampling and sampling strategies for environmental analysis   总被引:1,自引:0,他引:1  
Sampling errors are generally believed to dominate the errors of analytical measurement during the entire environmental data acquisition process. Unfortunately, environmental sampling errors are hardly quantified and documented even though analytical errors are frequently yet improperly reported to the third decimal point in environmental analysis. There is a significant discrepancy in directly applying traditional sampling theories (such as those developed for the binary particle systems) to trace levels of contaminants in complex environmental matrices with various spatial and temporal heterogeneities. The purpose of this critical review is to address several key issues in the development of an optimal sampling strategy with a primary goal of sample representativeness while minimizing the total number of samples and sampling frequencies, hence the cost for sampling and analysis. Several biased and statistically based sampling approaches commonly employed in environmental sampling (e.g. judgmental sampling and haphazard sampling vs. statistically based approaches such as simple random, systematic random, and stratified random sampling) are examined with respect to their pros and cons for the acquisition of scientifically reliable and legally defensible data. The effects of sample size, sample frequency and the use of compositing are addressed to illustrate the strategies for a cost reduction as well as an improved representativeness of sampling from spatially and temporally varied environmental systems. The discussions are accompanied with some recent advances and examples in the formulation of sampling strategies for the chemical or biological analysis of air, surface water, drinking water, groundwater, soil, and hazardous waste sites.  相似文献   

7.
A broad range of organic compounds is recognized as environmentally relevant for their potential adverse effects on human and ecosystem health. This method was developed to better determine the distribution of 61 compounds that are typically associated with industrial and household waste as well as some that are toxic and known (or suspected) for endocrine-disrupting potential extracted from environmental sediment samples. Pressurized liquid extraction (PLE) coupled with solid-phase extraction (SPE) was used to reduce sample preparation time, reduce solvent consumption to one-fifth of that required using dichloromethane-based Soxhlet extraction, and to minimize background interferences for full scan GC/MS analysis. Recoveries from spiked Ottawa sand, commercially available topsoil, and environmental stream sediment, fortified at 4-720 μg per compound, averaged 76 ± 13%. Initial method detection limits for single-component compounds ranged from 12.5 to 520 μg/kg, based on 25 g samples. Results from 103 environmental sediment samples show that 36 out of 61 compounds (59%) were detected in at least one sample with concentrations ranging from 20 to 100,000 μg/kg. The most frequently detected compound, beta-sitosterol, a plant sterol, was detected in 87 of the 103 (84.5%) environmental samples with a concentration range 360-100,000 μg/kg. Results for a standard reference material using dichloromethane Soxhlet-based extraction are also compared.  相似文献   

8.
An integrated analytical methodology has been developed for determining nitrogen-containing polycyclic aromatic hydrocarbons, which enables quantitation of individual contaminants as low as 1 μg/kg in sediment samples. A cross-sectional profile from the Hamilton Harbour sediment samples was analyzed for azaarenes. These contaminants were separated by Soxhlet extraction, and pH adjustment allowed their isolation from different classes of neutral and acidic components. Separation and identification of the organic bases in each sample were achieved by using open tubular column gas chromatography with thermionic detection and HRGC-mass spectrometry. Organic bases present in the samples included mostly azaarenes such as acridines, benzacridines, azafluorene, benzoquinolines, azapyrenes, etc. Quantitation and environmental significance of these compounds are discussed. Recoveries of individual azaarenes at two different levels were evaluated. Data presented indicate that detection limits of this method are between 1 and 10 μg/kg. Recovery azaarenes from bottom sediment samples at concentration levels between 1 to 100 μg/kg is 81 ± 17%.  相似文献   

9.
A novel UV-VIS spectrophotometric method was developed in this study by using solid phase extraction procedure for the simultaneous preconcentration, separation and determination of trace levels of Pb (II), Cd (II) and Zn (II) ions in various water samples by using Amberlite N,N-bis(salicylidene)cyclohexanediamine (SCHD) resin. This study presents the results of experimental procedures carried out like the adsorption of analytes to the resin, influences of some analytical parameters that effect the recovery such as pH, sample volume, sample flow rate, eluent type and concentration, eluent volume, eluent flow rate and the effects of alkaline metals, earth alkaline metals and some other transition metals. The analytes in the samples with the adjusted pH range of 4–7 were adsorbed on XAD-4-SCHD resin and eluted by using 1.0 mol L?1 nitric acid. The amounts of ions were determined by using UV-VIS spectrometer. The limits of detection were 0.03, 0.07 and 0.05 µg mL?1 for Pb (II), Cd (II) and Zn (II), respectively. The accuracy of the method was assured by the analysis of the certified standard water sample NW-TMDA-70.2 and the observed recoveries were above 93%. Different environmental water samples that contain trace amounts of Pb (II), Cd (II) and Zn (II) were analysed by using the method developed in this study. Same samples were also analysed by ICP-MS for comparison and almost the similar results were observed. The method developed in this study was successfully applied to the various environmental water samples to determine the trace levels of Pb (II), Cd (II) and Zn (II) ions.  相似文献   

10.
Abstract

Cloud point extraction (CPE) is a simple, inexpensive and green sample enrichment technique for different analytes in different matrices. In this technique surfactant solution is used at concentration above critical micelle concentration to extract the analytes from various matrices. Capillary electrophoresis (CE) and family of related techniques have emerged as powerful analytical techniques for pharmaceutical, biomedical, food and environmental analysis. In this review we have described the applications of CPE coupling with CE.  相似文献   

11.
A selective accelerated solvent extraction procedure achieved one step extraction and cleanup for analysis of herbicide atrazine and its metabolites in fruit. Using a BEH C18 analytical column and the gradient mode with 2 mM ammonium acetate aqueous solution/acetonitrile as a mobile phase achieved effective chromatographic separation of the five analytes within 4 min. The calibration curves were linear over two orders of magnitude of concentration with correlation coefficients (r) of 0.9996?0.9999. The method limit of quantification was 1, 2, 1.5, 3, and 2 μg/kg for atrazine, desethylatrazine, desisopropylatrazine, desethyldesisopropylatrazine, and hydroxyatrazine, respectively, in the case of atrazine it is at least two orders of magnitude lower than the maximum residue limit (0.25 mg/kg). The intra‐day and inter‐day precisions of the five analytes were in the range of 2.1–3.5 and 3.1–4.8 %, respectively. The recoveries of the five analytes at three spiked levels varied from 85.9 to 107% with a relative standard deviation of 1.8–4.9% for pear and apple samples. The ultra high performance liquid chromatography with diode array detection method was proved to be fast, inexpensive, selective, sensitive, and accurate for the quantification of the analytes in pear and apple samples.  相似文献   

12.
包月  翟怡鑫  宁涛  陈品  朱书奎 《色谱》2022,40(11):1005-1013
建立了一种基于共价有机框架材料的磁固相萃取-高效液相色谱方法,用于环境水样中对羟基苯甲酸酯的快速灵敏分析。首先以Fe3O4纳米粒子为磁核,通过1,3,5-苯三甲醛(Tb)和联苯胺(Bd)在室温下的席夫碱反应合成了磁性共价有机框架材料——Fe3O4@TbBd,通过扫描电镜、热重分析、X射线衍射和振动样品磁强计等表征手段证明了该磁性共价有机框架材料具有良好的热稳定性和化学稳定性,且磁响应强度较大,是用于磁固相萃取的理想材料。随后系统研究了影响萃取效率的因素,包括吸附剂用量、萃取时间、pH、解吸溶剂、解吸时间和解吸次数,建立了基于Fe3O4@TbBd的磁固相萃取-高效液相色谱测定环境水样中4种对羟基苯甲酸酯的方法。方法的线性范围良好,4种目标物的检出限和定量限范围分别为0.2~0.4 μg/L和0.7~1.4 μg/L,加标回收率为86.1%~110.8%,日内和日间精密度的相对标准偏差(RSD)分别低于5.5%和4.9%。最后将该方法应用于东湖水、长江水和生活废水中对羟基苯甲酸酯的测定,不同加标水平下对羟基苯甲酸酯的回收率在80.7%~117.5%之间,RSD在0.2%~8.8%之间。该方法操作简单,萃取时间短,灵敏度较高且对环境友好,在环境水样中对羟基苯甲酸酯的检测方面有良好的应用潜力。  相似文献   

13.
In chemical analysis, sample preparation is frequently considered the bottleneck of the entire analytical method. The success of the final method strongly depends on understanding the entire process of analysis of a particular type of analyte in a sample, namely: the physicochemical properties of the analytes (solubility, volatility, polarity etc.), the environmental conditions, and the matrix components of the sample. Various sample preparation strategies have been developed based on exhaustive or non-exhaustive extraction of analytes from matrices. Undoubtedly, amongst all sample preparation approaches, liquid extraction, including liquid–liquid (LLE) and solid phase extraction (SPE), are the most well-known, widely used, and commonly accepted methods by many international organizations and accredited laboratories. Both methods are well documented and there are many well defined procedures, which make them, at first sight, the methods of choice. However, many challenging tasks, such as complex matrix applications, on-site and in vivo applications, and determination of matrix-bound and free concentrations of analytes, are not easily attainable with these classical approaches for sample preparation.  相似文献   

14.
In‐syringe solid‐phase extraction is a promising sample pretreatment method for the on‐site sampling of water samples because of its outstanding advantages of portability, simple operation, short extraction time, and low cost. In this work, a novel in‐syringe solid‐phase extraction device using metal–organic frameworks as the adsorbent was fabricated for the on‐site sampling of polycyclic aromatic hydrocarbons from environmental waters. Trace polycyclic aromatic hydrocarbons were effectively extracted through the self‐made device followed by gas chromatography with mass spectrometry analysis. Owing to the excellent adsorption performance of metal–organic frameworks, the analytes could be completely adsorbed during one adsorption cycle, thus effectively shortening the extraction time. Moreover, the adsorbed analytes could remain stable on the device for at least 7 days, revealing the potential of the self‐made device for on‐site sampling of degradable compounds in remote regions. The limit of detection ranged from 0.20 to 1.9 ng/L under the optimum conditions. Satisfactory recoveries varying from 84.4 to 104.5% and relative standard deviations below 9.7% were obtained in real samples analysis. The results of this study promote the application of metal–organic frameworks in sample preparation and demonstrate the great potential of in‐syringe solid‐phase extraction for the on‐site sampling of trace contaminants in environmental waters.  相似文献   

15.
The miniaturization and improvement of sample preparation is a challenge that has been fulfilled up to a point in many fields of analytical chemistry. Particularly, the hyphenation of microextraction with advanced analytical techniques has allowed the monitoring of target analytes in a vast variety of environmental samples. Several benefits can be obtained when miniaturized techniques such as solid-phase microextraction (SPME) or liquid-phase microextraction (LPME) are applied, specifically, their easiness, rapidity and capability to separate and pre-concentrate target analytes with a negligible consumption of organic solvents. In spite of the great acceptance that these green sample preparation techniques have in environmental research, their full implementation has not been achieved or even attempted in some relevant environmental matrices.  相似文献   

16.
Summary In addition to its well-known advantages (e.g. ease of automation, high sample throughout and versatility, low sample and reagent consumption and analytical costs), flow injection analysis (FIA) offers the possibility of solving a number of specific analytical problems where poor sensitivity or selectivity, time-consuming preliminary steps, the use of HPLC in routine control for the analysis of a large number of samples, the determination of various analytes (multidetermination) or process monitoring in near-real time is involved.  相似文献   

17.
Pitfalls in compound-specific isotope analysis of environmental samples   总被引:1,自引:0,他引:1  
In the last decade compound-specific stable isotope analysis (CSIA) has evolved as a valuable technique in the field of environmental science, especially in contaminated site assessment. Instrumentation and methods exist for highly precise measurements of the isotopic composition of organic contaminants even in a very low concentration range. Nevertheless, the determination of precise and accurate isotope data of environmental samples can be a challenge. Since CSIA is gaining more and more popularity in the assessment of in situ biodegradation of organic contaminants, an increasing number of authorities and environmental consulting offices are interested in the application of the method for contaminated site remediation. Because of this, it is important to demonstrate the problems and limitations associated with compound-specific isotope measurements of environmental samples. In this review, potential pitfalls of the analytical procedure are critically discussed and strategies to avoid possible sources of error are provided. In order to maintain the analytical quality and to ensure the basis for reliable stable isotope data, recommendations on groundwater sampling, and sample preservation and storage are given. Important aspects of sample preparation and preconcentration techniques to improve sensitivity are highlighted. Problems related to chromatographic resolution and matrix interference are discussed that have to be considered in order to achieve accurate gas chromatography/isotope ratio mass spectrometry measurements. As a result, the need for a thorough investigation of compound-specific isotope fractionation effects introduced by any step of the overall analytical method by standards with known isotopic composition is emphasized. Finally, we address some important points that have to be considered when interpreting data from field investigations. Figure CSIA Principal (Carbon)  相似文献   

18.
Efstathiou CE 《Talanta》2000,52(4):711-715
Contemporary analytical methodology allows the determination of substances in ultra-dilute solutions, i.e. picomol per liter (pM) and lower, by employing a wide spectrum of techniques. The reduction of both sample volume and quantification limits made possible the determination of zeptomol amounts of analytes. Among the many problems associated with the analysis of this kind of sample is the relatively high intrinsic sampling variance which restricts the attainable overall analytical precision. This sampling variance is due to the quantized nature of matter. The expected sampling variance can be calculated considering that the limited number of analyte molecules per test-portion is subjected to Poisson distribution.  相似文献   

19.
Sludge generated after washing of fruits and vegetables during agro-food processes is a complex matrix and selective methods for the identification and quantification of pesticides’ residues are necessary in order to achieve a sustainable and effective management of the total sewage. The present work describes the development and validation of a reliable, simple and fast analytical method based on liquid chromatography-tandem mass spectrometry (LC-MS/MS) for the determination of 47 pesticides of different chemical classes, including organosphosphates, pyrethroids, neonicotinoids, triazoles and others, in sludge samples after QuEChERS sample preparation. The necessity of the individual steps of QuEChERS was investigated and the LC-ESI-MS/MS conditions were optimized to achieve maximum sensitivity of the target analytes. The method limits of detection (LODs) ranged between 0.0005 mg/kg (imidacloprid) and 0.05 mg/kg (beta cyfluthrin). The recoveries ranged between 71–120% and the repeatability of the method was ≤25% expressed as relative standard deviation. The method was applied to sludge samples generated after washing of fruits in an agro-fruit-packaging unit in Greece. The results showed the presence of 37 pesticides’ active substances with concentrations ranging from low ppbs, such as fludioxinil (5 μg/kg) up to low ppms such as beta cyfluthrin (3.5 mg/kg) and with their sum concentration reaching up to 19 mg/kg.  相似文献   

20.
The variability associated with testing lots of green coffee beans for ochratoxin A (OTA) was investigated. Twenty-five lots of green coffee were tested for OTA contamination. The total variance associated with testing green coffee was estimated and partitioned into sampling, sample preparation, and analytical variances. All variances increased with an increase in OTA concentration. Using regression analysis, mathematical expressions were developed to model the relationship between OTA concentration and the total, sampling, sample preparation, and analytical variances. The expressions for these relationships were used to estimate the variance for any sample size, subsample size, and number of analyses for a specific OTA concentration. Testing a lot with 5 microg/kg OTA using a 1 kg sample, Romer RAS mill, 25 g subsamples, and liquid chromatography analysis, the total, sampling, sample preparation, and analytical variances were 10.75 (coefficient of variation [CV] = 65.6%), 7.80 (CV = 55.8%), 2.84 (CV = 33.7%), and 0.11 (CV = 6.6%), respectively. The total variance for sampling, sample preparation, and analytical were 73, 26, and 1%, respectively.  相似文献   