首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
We have evaluated double-stranded DNA separations in microfluidic devices which were designed to couple a sample preconcentration step based on isotachophoresis (ITP) with a zone electrophoretic (ZE) separation step as a method to increase the concentration limit of detection in microfluidic devices. Developed at ACLARA BioSciences, these LabCard trade mark devices are plastic 32 channel chips, designed with a long sample injection channel segment to increase the sample loading. These chips were designed to allow stacking of the sample into a narrow band using discontinuous ITP buffers, and subsequent separation in the ZE mode in sieving polymer solutions. Compared to chip ZE, the sensitivity was increased by 40-fold and we showed baseline resolution of all fragments in the PhiX174/HaeIII DNA digest. The total analysis time was 3 min/sample, or less than 100 min per LabCard device. The resolution for multiplexed PCR samples was the same as obtained in chip ZE. The limit of detection was 9 fg/microL of DNA in 0.1xpolymerase chain reaction (PCR) buffers using confocal fluorescence detection following 488 nm laser excitation with thiazole orange as the fluorescent intercalating dye.  相似文献   

2.
Capillary gel electrophoresis has proven to be a powerful tool in biomedical research. We report our investigation of some of the critical parameters affecting separations of single-stranded DNA fragments as monitored by ultraviolet (UV) absorbance detection. Although not as sensitive as laser-induced fluorescence (LIF), UV absorbance detection allows one to calculate quite accurately, and inexpensively, the molarity of each separated DNA fragment and, moreover, the signal “fading” effect normally observed with LIF detection can be, in many cases, substituted for fluorescence to detect the many different single-stranded DNAs, as well as for detection of sequencing reactions.  相似文献   

3.
Force-extension curves (FECs), which quantify the response of a variety of biomolecules subject to mechanical force (f), are often quantitatively fit using worm-like chain (WLC) or freely jointed chain (FJC) models. These models predict that the chain extension, x, normalized by the contour length increases linearly at small f and at high forces scale as x ~ (1 - f(-α)), where α = 0.5 for WLC and unity for FJC. In contrast, experiments on single-stranded DNA (ssDNA) show that over a range of f and ionic concentration, x scales as x ~ ln f, which cannot be explained using WLC or FJC models. Using theory and simulations we show that this unusual behavior in FEC in ssDNA is due to sequence-independent polyelectrolyte effects. We show that the x ~ ln f arises because in the absence of force the tangent correlation function, quantifying chain persistence, decays algebraically on length scales on the order of the Debye length. Our theory, which is most appropriate for monovalent salts, quantitatively fits the experimental data and further predicts that such a regime is not discernible in double-stranded DNA.  相似文献   

4.
This study reports improved pulsed field capillary electrophoresis (PFCE) for separation of large DNA ladders. Important analytical conditions, including gel polymer concentration, ratio of forward to backward pulse duration, and separation potential, were investigated for their effects on the separation performance of DNA ranging in size from 0.1 to 10.0 kilo base pairs (kbp). Results show that DNA fragments from 0.1 to 8.0 kbp can be resolved with high resolution, simultaneously, in a short time. The ratio of forward to backward pulse duration affects the separation performance for DNA fragments greater than 1.5 kbp, and 3 or 4 is the optimum value of the ratio for separation of DNA up to 10 kbp. Furthermore, the separations that were obtained with 74–19,329 bp λ-DNA restriction fragments clearly demonstrate a dramatic improvement in the separation time and resolution over the conventionally used square-wave PFCE. The inversion field capillary electrophoresis reported here may help enable future DNA analysis studies to be performed quickly and effectively.  相似文献   

5.
A method to continuously separate different particle types in a suspension is reported. Acoustic forces in a standing wave field were utilized to discriminate lipid particles from erythrocytes in whole blood. The presented technology proposes a new method of cleaning, i.e. removing lipid emboli from, shed blood recovered during cardiac surgery. Blood contaminated with lipid particles enter a laminar flow micro channel. Erythrocytes and lipid particles suspended in blood plasma are exposed to a half wavelength standing wave field orthogonal to the direction of flow as they pass through the channel. Because of differences in compressibility and density the two particle types move in different directions, the erythrocytes towards the centre of the channel and the lipid particles towards the side walls. The end of the channel is split into three outlet channels conducting the erythrocytes to the centre outlet and the lipid particles to the side outlets due to the laminar flow profile. The separation channel was evaluated in vitro using polyamide spheres suspended in water, showing separation efficiencies approaching 100%. The system was also evaluated on whole blood using tritium labelled lipid particles added to bovine blood. More than 80% of the lipid particles could be removed while approximately 70% of the erythrocytes were collected in one third of the original fluid volume. The study showed that the further reduced micro channel dimensions provided improved performance with respect to; (i) separation efficiency, (ii) actuation voltage, and (iii) volumetric throughput as compared to earlier work.  相似文献   

6.
DA Vickers  EJ Chory  SK Murthy 《Lab on a chip》2012,12(18):3399-3407
To isolate clinically and biologically relevant cell types from a heterogeneous population, fluorescent or magnetic tagging together with knowledge of surface biomarker profiles represents the state of the art. To date, it remains exceedingly difficult to separate phenotypically and physically similar cell types from a mixed population. We report a microfluidic platform engineered to separate two highly similar cell types using a single antibody by taking advantage of subtle variations in surface receptor density and cell size. This platform utilizes antibody-conjugated surfaces in microfluidic channels together with precise modulation of fluid shear stresses to accomplish selective fractionation in a continuous flow process. Antibody conjugation density variation on the adhesive surfaces is achieved by covalently immobilizing an antibody in the presence of poly(ethylene glycol). This platform is used to demonstrate separation of two CD31 positive cell types, human umbilical vein endothelial cells and human micro vascular endothelial cells.  相似文献   

7.
8.
Lo RC  Ugaz VM 《Electrophoresis》2006,27(2):373-386
Considerable effort has been directed toward optimizing performance and maximizing throughput in ssDNA electrophoresis because it is a critical analytical step in a variety of genomic assays. Ultimately, it would be desirable to quantitatively determine the achievable level of separation resolution directly from measurements of fundamental physical properties associated with the gel matrix rather than by the trial and error process often employed. Unfortunately, this predictive capability is currently lacking, due in large part to the need for a more detailed understanding of the fundamental parameters governing separation performance (mobility, diffusion, and dispersion). We seek to address this issue by systematically characterizing electrophoretic mobility, diffusion, and dispersion behavior of ssDNA fragments in the 70-1,000 base range in a photopolymerized cross-linked polyacrylamide matrix using a slab gel DNA sequencer. Data are collected for gel concentrations of 6, 9, and 12%T at electric fields ranging from 15 to 40 V/cm, and resolution predictions are compared with corresponding experimentally measured values. The data exhibit a transition from behavior consistent with the Ogston model for small fragments to behavior in agreement with the biased reptation model at larger fragment sizes. Mobility data are also used to estimate the mean gel pore size and compare the predictions of several models.  相似文献   

9.
Latex agglutination tests are used for the diagnosis of diseases in man and animals. They are generally simple, cheap, and do not require sophisticated equipment, nor highly specialized skills. In this Technical Note, we put latex agglutination tests in a microfluidic format. The experiment is performed in PDMS (polydimethylsiloxane) microchannels, using streptavidin-coated superparamagnetic beads and a magnetic field. The target molecule is biotinylated protein A. By taking full advantage of the microfluidic conditions (scaling down of the detection volume and controlled action of the shear flow), we achieved an analytical sensitivity of 10 fmol l(-1)(several hundreds of fg ml(-1)) and a fast response (a few minutes) ; the test is also quantitative. Performances of agglutination tests can thus be improved by orders of magnitude by adapting them to a microfluidic format; this comes in addition to the usual advantages offered by this technology (integration, high throughput etc.).  相似文献   

10.
11.
Electrokinetic transport within a buffer-filled microchannel incorporating a flat bipolar electrode is investigated. The key finding is that the presence of the electrode disrupts the passage of electrical current through the microchannel and thereby alters the uniformity of the local electric field. Electroosmotic flow further modulates the local field gradient. These dynamics are demonstrated experimentally by utilizing the field gradient for concentration enrichment of negatively charged tracer molecules, and a set of computer simulations is presented to interpret the underlying electrokinetics.  相似文献   

12.
Song L  Liu T  Liang D  Fang D  Chu B 《Electrophoresis》2001,22(17):3688-3698
Mixtures of two polymers with totally different chemical structures, polyacrylamide and polyvinylpyrrolidone (PVP) have been successfully used for double-stranded DNA separation. By polymerization of acrylamide in a matrix of PVP solution, the incompatibility of these two polymers was suppressed. Laser light scattering (LLS) studies showed that highly entangled interpenetrating networks were formed in the solution. Further systematic investigation showed that double-stranded DNA separation was very good in these interpenetrating networks. With a concentration combination of as low as 2% w/v PVP (weight-average molecular mass Mr = 1 x 10(6) g/mol) + 1% w/v polyacrylamide (Mr = 4 x 10(5) g/mol), the 22 fragments in pBR322/HaeIII DNA, including the doublet of 123/124 bp, have been successfully separated within 6.5 min. Under the same separation conditions, similar resolution could only be achieved by using polyacrylamide (Mr = 4 x 10(5) g/mol) with concentrations higher than 6% w/v and could not be achieved by using only PVP (Mr = 1 x 10(6) g/mol) with a concentration as high as 15% w/v. It is noted that the interpenetrating network formed by 2% PVP and 1% polyacrylamide has a very low viscosity and can dynamically coat the inner wall of a fused-silica capillary. The separation reached an efficiency of more than 10(7) theoretical plate numbers/m and a reproducibility of less than 1% relative standard deviation of migration time in a total of seven runs. The interpenetrating network could stabilize polymer chain entanglements. Consequently, the separation speed was increased while retaining resolution.  相似文献   

13.
The novel polymer matrices reported here are low-viscosity sieving media for DNA capillary electrophoresis. This new family of matrices comprises copolymers of N,N-dimethylacrylamide with different monomers which increase polymer hydrophilicity. All these new copolymers self-coat on fused-silica capillaries. Resolution, peak spacing and peak width were the parameters taken into account to assess the influence of polymer structure on separation selectivity and efficiency. This work demonstrates that the performance of polydimethylacrylamide (PDMA) can be improved through copolymerization with hydrophilic monomers. The improvement is related to the efficiency parameter. The new copolymers, due to their low viscosity high sieving capacity and ability to suppress EOF, represent a better alternative to PDMA and are suitable replaceable matrices for capillary and microchip electrophoresis.  相似文献   

14.
A probe-regulated simultaneous separation (PRESS) using capillary electrophoresis (CE) was developed for separating single-stranded (ss) DNAs. We synthesized two DNA conjugate probes, -(5'-TGTGTGTGT-3')p-AAm(q)- and -(5'-GCCACCAGC-3')m-AAm(n)-, by copolymerizing 5'-methacryloyl-modified ssDNA with acrylamide (AAm), and characterized them in detail. The two probes showed lower electrophoretic mobilities than 5'-methacryloyl-modified ssDNAs. Furthermore, -(5'-TGTGTGTGT-3')p-AAm(q)- showed slightly faster electrophoretic mobility toward the anode than -(5'-GCCACCAGC-3')m-AAm(n)- due to its higher molar fraction of negatively-charged ssDNA. We successfully separated target ssDNAs having the same chain length by using two ssDNA conjugate probes that showed different electrophoretic mobilities, although the separation of these ssDNAs was difficult in conventional capillary electrophoresis systems.  相似文献   

15.
While polymer-based microfluidic devices offer some unique opportunities in developing low-cost systems for a variety of application areas, the ability to sort electrophoretically with high efficiency a number of different targets has remained somewhat elusive with an example consisting of achieving single base resolution as required for DNA sequencing. While the reasons for this are many-fold, it is clear that some type of coating is required on the polymer substrate to suppress the EOF and/or minimize potential solute/wall interactions. To this end, we report on a simple grafting procedure to allow the formation of polymer coats, which in this example used linear polyarcylamides (LPAs), onto a poly(methyl methacrylate) (PMMA) microfluidic device. The procedure involved creating an amine-terminated PMMA surface by appropriately functionalizing the PMMA through either a chemical or photochemical process. The aminated surface could then be used to covalently anchor methacrylic acid, which was used as a scaffold to produce LPAs on the surface through radical polymerization of acrylamide. The resulting surfaces demonstrated EOFs that were nearly an order of magnitude smaller than native PMMA. In addition, these LPA-coated devices could produce highly reproducible migration times of over approximately 20 runs with plate numbers exceeding 10(5) m(-1). Using gel electrophoretic analysis of a single base track generated from an M13mp18 template using Sanger cycle sequencing and dye-primer chemistry, the resolution value obtained for bases 199 and 200 was 0.18 while for bases 208 and 209 it was 0.21. For the native PMMA, these bands were found to comigrate.  相似文献   

16.
Kang SH  Park M  Cho K 《Electrophoresis》2005,26(16):3179-3184
We evaluated a novel strategy for fast diagnosis by microchip electrophoresis (ME), using programmed field strength gradients (PFSG) in a conventional glass double-T microfluidic chip. The ME-PFSG allows for the ultrafast separation and enhanced resolving power for target DNA fragments. These results are based on electric field strength gradients (FSG) that use an ME separation step in a sieving gel matrix poly-(ethylene oxide). The gradient can develop staircase or programmed shapes FSG over the time. The PFSG method could be easily used to increase separation efficiency and resolution in ME separation of specific size DNA fragments. Compared to ME that uses a conventional and constantly applied electric field (isoelectrostatic) method, the ME-PFSG achieved about 15-fold faster analysis time during the separation of 100 bp DNA ladder. The ME-PFSG was also applied to the fast analysis of the PCR products, 591 and 1191 bp DNA fragments from the 18S rRNA of Babesia gibsoni and Babesia caballi.  相似文献   

17.
Pyrrolobenzodiazepine (PBD) antitumor agents have, to date, only been observed to bind to duplex DNA, apparently requiring a minor groove environment for covalent bond formation between their C11-position and the C2-NH(2) functionality of a guanine base. Using an HPLC/MS assay we have now observed and isolated for the first time PBD adducts with single-stranded DNA fragments. Surprisingly, these adducts could only be formed through dissociation of duplex DNA adducts and not by direct interaction of PBDs with single-stranded DNA. They were sufficiently stable for characterization by MALDI-TOF-MS and remained intact after storing at -20 °C for at least 20 days, although the PBD became detached from the DNA within 7 days if stored at room temperature. Furthermore, addition of a complementary strand allowed the duplex adduct to reform. The relative stability of single-stranded PBD/DNA adducts despite a complete loss of minor groove structure was further confirmed by CD spectroscopic analysis. The CD signal induced by the presence of a PBD molecule in the single-stranded adducts remained prominent despite heating for 2 h at 50-60 °C, thus indicating their relatively robust nature.  相似文献   

18.
Electrokinetic gating, functioning as a micro-valve, has been widely employed in microfluidic chips for sample injection and flow switch. Investigating its valving performance is fundamentally vital for microfluidics and microfluidics-based chemical analysis. In this paper, electrokinetic gating valve in microchannels was evaluated using optical imaging technique. Microflow profiles at channels junction were examined, revealing that molecular diffusion played a significant role in the valving disable; which could cause analyte leakage in sample injection. Due to diffusion, the analyte crossed the interface of the analyte flow and gating flow, and then formed a cometic tail-like diffusion area at channels junction. From theoretical calculation and some experimental evidences, the size of the area was related to the diffusion coefficient and the velocity of analytes. Additionally, molecular diffusion was also believed to be another reason of sampling bias in gated injection.  相似文献   

19.
With the advent of next-generation sequencing (NGS) systems and the associated high throughput they afford, the input to these machines requires manageable lengths of fragments (~1000 bp) produced from chromosomal DNAs. Therefore, it is critical to develop devices that can shear DNA in a controlled fashion. We report a polymer-based microfluidic device that establishes an efficient and inexpensive platform with performance comparable to a commercially available bench-top system.  相似文献   

20.
We have investigated the effect of polymer gel reconditioning, the shape of the capillary, the applied electric field, and the capillary length for single-stranded DNA. The polyethylene oxide gel had deformed under the high electric field causing the degradation of the separation power. By the reintroduction of the fresh polyethylene oxide gel for the next run, one-base resolution was recovered. It turned out that the tip of the capillary at the injection side needed to be clean and symmetric for much improved resolution. Changing DNA motion by the pulsed electric field resulted in the separation of DNA far more than 500 bases.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏