首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
2.
A rapid multianalyte‐multiclass method with little sample manipulation has been developed for the simultaneous determination of eleven mycotoxins in different food commodities by using ultra‐high‐pressure liquid chromatography coupled to triple quadrupole mass spectrometry (UHPLC/MS/MS). Toxins were extracted from the samples with acetonitrile/water (80:20, v/v) 0.1% HCOOH and, after a two‐fold dilution with water, directly injected into the system. Thanks to the fast high‐resolution separation of UHPLC, the eleven mycotoxins were separated by gradient elution in only 4 min. The method has been validated in three food matrices (maize kernels, dry pasta (wheat), and eight‐multicereal babyfood (wheat, maize, rice, oat, barley, rye, sorghum, millet)) at four different concentration levels. Satisfactory recoveries were obtained (70–110%) and precision (expressed as relative standard deviation) was typically below 15% with very few exceptions. Quantification of samples was carried out with matrix‐matched standards calibration. The lowest concentration successfully validated in sample was as low as 0.5 µg/kg for aflatoxins and ochratoxin A in babyfood, and 20 µg/kg for the rest of the selected mycotoxins in all matrices tested. Deoxynivalenol could be only validated at 200 µg/kg, due the poor sensitivity for this mycotoxin analysis. With only two exceptions (HT‐2 and deoxynivalenol), the limits of detection (LODs), estimated for a signal‐to‐noise ratio of 3 from the chromatograms of samples spiked at the lowest level validated, varied between 0.1 and 1 µg/kg in the three food matrices tested. The method was applied to the analysis of different kinds of samples. Positive findings were confirmed by acquiring two transitions (Q quantification, q confirmation) and evaluating the Q/q ratio. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

3.
Precise measurement of low enrichment of stable isotope labeled amino‐acid tracers in tissue samples is a prerequisite in measuring tissue protein synthesis rates. The challenge of this analysis is augmented when small sample size is a critical factor. Muscle samples from human participants following an 8 h intravenous infusion of L‐[ring‐13C6]phenylalanine and a bolus dose of L‐[ring‐13C6]phenylalanine in a mouse were utilized. Liquid chromatography tandem mass spectrometry (LC/MS/MS), gas chromatography (GC) MS/MS and GC/MS were compared to the GC‐combustion‐isotope ratio MS (GC/C/IRMS), to measure mixed muscle protein enrichment of [ring‐13C6]phenylalanine enrichment. The sample isotope enrichment ranged from 0.0091 to 0.1312 molar percent excess. As compared with GC/C/IRMS, LC/MS/MS, GC/MS/MS and GC/MS showed coefficients of determination of R2 = 0.9962 and R2 = 0.9942, and 0.9217 respectively. However, the precision of measurements (coefficients of variation) for intra‐assay are 13.0%, 1.7%, 6.3% and 13.5% and for inter‐assay are 9.2%, 3.2%, 10.2% and 25% for GC/C/IRMS, LC/MS/MS, GC/MS/MS and GC/MS, respectively. The muscle sample sizes required to obtain these results were 8 µg, 0.8 µg, 3 µg and 3 µg for GC/C/IRMS, LC/MS/MS, GC/MS/MS and GC/MS, respectively. We conclude that LC/MS/MS is optimally suited for precise measurements of L‐[ring‐13C6]phenylalanine tracer enrichment in low abundance and in small quantity samples. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

4.
ABSTRACT

A fast, simple, low-cost and high-throughput multiresidue pesticide analysis method was developed and validated for 300 pesticides in herbal and fruit infusion samples based on modified QuEChERS (quick, easy, cheap, effective, rugged and safe) procedure combined with gas chromatography coupled with tandem mass spectrometry method (GC-MS/MS). The objectives were to develop low cost GC-MS/MS method, validate the method in accordance to SANTE/11,813/2017 guidance document and application in routine. The results obtained using different GC and MS/MS parameters were evaluated in order to develop quick, robust, accurate and effective multiresidue method. Total analysis time was 28 min with 0.6 µL injection volume. For accurate quantification, matrix-matched calibration (MMC) curves (in range of 10 µg/kg – 250 µg/kg) were applied to compensate matrix effect. The limits of quantification (LOQ) were ranged between 0.06 µg/kg and 135 µg/kg, and for the majority of the pesticides the LOQ were below the regulatory maximum residue limits. Most recoveries at 10 µg/kg and 100 µg/kg were in the range 70%–120% indicating satisfactory accuracy. The validated method was applied to commercial herbal and fruit infusion products detecting chlorpyriphos, DEET, tebuconazole, terbuthylazine, piperonyl butoxide, biphenyl, pendimethalin, pirimiphos-methyl and p,p’-DDE in more than 100 samples from 1,466 so risk assessment on human health was calculated specially for those pesticides.  相似文献   

5.
Paraquat (PQ) is an herbicide implicated in numerous fatalities, mainly caused by voluntary ingestion. Several methods have been used to quantify PQ in plasma and urine samples of intoxicated humans as a predictor of clinical outcome. There is no validated method for the analysis of PQ in postmortem samples. Therefore, the aim of this study was to develop an analytical method, using gas chromatography–ion trap mass spectrometry (GC‐IT/MS) after solid‐phase extraction, to quantify PQ in postmortem samples, namely in whole blood, urine, liver, lung and kidney, to cover the routes of distribution, accumulation and elimination of PQ. The method proved to be selective as there were no interferences of endogenous compounds with the same retention time as PQ and ethyl paraquat (internal standard). The regression analysis for PQ was linear in the range 0–10 µg/mL. The detection limits ranged from 0.0076 µg/mL for urine to 0.047 µg/mL for whole blood, and the recoveries were suitable for forensic analysis. The proposed GC‐IT/MS method provided an accurate and simple assay with adequate precision and recovery for the quantification of PQ in postmortem samples. The proof of applicability was performed in two fatal PQ intoxications. A review of the analytical methods for the determination of quaternary ammonium herbicides is also provided for a better understanding of the presently available techniques. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

6.
A simple and sensitive gas chromatography–electron ionization–mass spectrometry (GC‐EI‐MS) method using dried plasma spot testing cards was developed for determination of valproic acid and gabapentin concentrations in human plasma from patients receiving in‐home medical care. We have proposed that a simple, easy and dry sampling method is suitable for in‐home medical patients for therapeutic drug monitoring. Therefore, in the present study, we used recently developed commercially available easy handling cards: Whatman FTA DMPK‐A and Bond Elut DMS. In‐home medical care patients can collect plasma using these simple kits. The spots of plasma on the cards were extracted into methanol and then evaporated to dryness. The residues were trimethylsilylated using N‐methyl‐N‐trimethylsilyltrifluoroacetamide. For GC‐EI‐MS analysis, the calibration curves on both cards were linear from 10 to 200 µg/mL for valproic acid, and from 0.5 to 10 µg/mL for gabapentin. Intra‐ and interday precisions in plasma were both ≤13.0% (coefficient of variation), and the accuracy was between 87.9 and 112% for both cards within the calibration curves. The limits of quantification were 10 µg/mL for valproic acid and 0.5 µg/mL for gabapentin on both cards. We believe that the present method will be useful for in‐home medical care. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

7.
The potential of gas chromatography coupled to tandem mass spectrometry (GC/MS/MS) with a triple quadrupole analyzer (QqQ) has been investigated for the quantification and reliable identification of sixteen polycyclic aromatic hydrocarbons (PAHs) from the EPA priority list in animal and vegetable samples from aquaculture activities, whose fat content ranged from 5 to 100%. Matrices analyzed included fish fillet, fish feed, fish oil and linseed oil. Combining optimized saponification and solid‐phase extraction led to high efficiency in the elimination of interfering compounds, mainly fat, from the extracts. The developed procedure minimized the presence of these interfering compounds in the extracts and provided satisfactory recoveries of PAHs. The excellent sensitivity and selectivity of GC/(QqQ)MS/MS in selected reaction monitoring (SRM) allowed to reach limits of detection at pg/g levels. Two SRM transitions were acquired for each analyte to ensure reliable identification of compounds detected in samples. Confirmation of positive findings was performed by GC coupled to high‐resolution time‐of‐flight mass spectrometry (GC/TOFMS). The accurate mass information provided by GC/TOFMS in full acquisition mode together with its high mass resolution makes it a powerful analytical tool for the unequivocal confirmation of PAHs in the matrices tested. The method developed was applied to the analysis of real‐world samples of each matrix studied with the result of detecting and confirming the majority of analytes at the µg/kg level by both QqQ and TOF mass spectrometers. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

8.
A rapid environmental pollution screening and monitoring workflow based on fabric phase sorptive extraction‐gas chromatography‐tandem mass spectrometry (FPSE‐GC‐MS/MS) is proposed for the first time for the analysis of 17 widespread used fungicides (metalaxyl, cyprodinil, tolylfluanid, procymidone, folpet, fludioxonil, myclobutanil, kresoxim methyl, iprovalicarb, benalaxyl, trifloxystrobin, fenhexamid, tebuconazole, iprodione, pyraclostrobin, azoxystrobin and dimethomorph) in environmental waters. The most critical parameters affecting FPSE, such as sample volume, matrix pH, desorption solvent and time, and ionic strength were optimized by statistical design of experiment to obtain the highest extraction efficiency. Under the optimized conditions, the proposed FPSE‐GC‐MS/MS method was validated in terms of linearity, repeatability, reproducibility, accuracy and precision. To assess matrix effects, recovery studies were performed employing different water matrices including ultrapure, fountain, river, spring, and tap water at 4 different concentration levels (0.1, 0.5, 1 and 5 µg/L). Recoveries were quantitative with values ranging between 70–115%, and relative standard deviation values lower than 14%. Limits of quantification were at the low ng/L for all the target fungicides. Finally, the validated FPSE‐GC‐MS/MS method was applied to real water samples, revealing the presence of 11 out of the 17 target fungicides.  相似文献   

9.
Solid-phase microextraction (SPME) coupled with gas chromatography–mass spectrometry (GC–MS) and selected ion monitoring (SIM) was used for the analytical determination of priority pesticide residues. Fibers coated with a 65-µm film thickness of polydimethylsiloxane divinylbenzene (PDMS-DVB) were used to extract 31 pesticides of different chemical groups. The quality parameters of the method demonstrated a good precision with detection limits of 1–56?ng/L. Linearity was controlled in the range of 0.1–50?µg/L. The proposed method was applied for the trace-level determination of the target pesticides in surface water samples including three rivers and one lake at the Epirus region (north-west Greece) for a period of one year. The results demonstrate the suitability of the SPME–GC–MS approach for the analysis of multi-residue pesticides in environmental water samples.  相似文献   

10.
A qualitative and quantitative analytical method was developed for the simultaneous determination of 24 illicit drugs and medicines, in preserved oral fluid samples collected with the StatSure Saliva Sampler? collection device. The samples were prepared by liquid‐liquid extraction followed by liquid chromatography/tandem mass spectrometry (LC/MS/MS) analysis. The chromatographic separation was performed with an Atlantis T3 (100 × 2.1 mm i.d., 3 µm) reversed‐phase column using an acetonitrile/2 mM ammonium formate buffer pH 3.4 gradient and the MS/MS detection was achieved with two precursor‐product ion transitions per substance. The method was fully validated, including specificity and capacity of identification, limit of detection (0.2–2.1 µg/L), limit of quantitation (0.8–6.4 µg/L), recovery (34–98%), carryover, linearity (the method was linear in the range 1–200 µg/L), intra‐assay precision (coefficient of variance (CV) <20% for 20 µg/L and CV <10% for 100 µg/L) and inter‐assay accuracy (mean relative error <15%) and precision (CV <20%). The method showed to be specific and sensitive. It has already been successfully used in four proficiency tests and subsequently applied to oral fluid samples collected from road traffic volunteers in the driving population of Portugal (districts of Lisbon, Coimbra and Porto), within the DRUID project. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

11.
An accurate and precise method for the quantification of 11‐nor‐Δ9‐tetrahydrocannabinol‐9‐carboxylic acid (THCA) in urine by liquid chromatography/tandem mass spectrometry (LC/MS/MS) for doping analysis purposes has been developed. The method involves the use of only 200 µL of urine and the use of D9‐THCA as internal standard. No extraction procedure is used. The urine samples are hydrolysed using sodium hydroxide and diluted with a mixture of methanol/glacial acetic acid (1:1). Chromatographic separation is achieved using a C8 column with gradient elution. All MS and MS/MS parameters were optimised in both positive and negative electrospray ionisation modes. For the identification and the quantification of THCA three product ions are monitored in both ionisation modes. The method is linear over the studied range (5–40 ng/mL), with satisfactory intra‐and inter‐assay precision, and the relative standard deviations (RSDs) are lower than 15%. Good accuracy is achieved with bias less than 10% at all levels tested. No significant matrix effects are observed. The selectivity and specificity are satisfactory, and no interferences are detected. The LC/MS/MS method was applied for the analysis of 48 real urine samples previously analysed with a routine gas chromatography/mass spectrometry (GC/MS) method. A good correlation between the two methods was obtained (r2 > 0.98) with a slope close to 1. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

12.
A sensitive and specific ultra‐performance liquid chromatography–tandem mass spectrometry (UPLC‐MS‐MS) method for quantification of a newly developed anticancer agent NPD‐103 has been established. An aliquot of human plasma sample (200 µL) was spiked with 13C‐labeled paclitaxel (internal standard) and extracted with 1.3 mL of tert‐butyl methyl ether. NPD‐103 was quantitated on a C18 column with methanol–0.1% formic acid (75:25, v/v) as mobile phase using UPLC‐MS‐MS operating in positive electrospray ionization mode with a total run time of 3.0 min. For NPD‐103 at the concentrations of 1.0, 5.0 and 10.0 µg/mL in human plasma, the absolute extraction recoveries were 95.58, 102.43 and 97.77%, respectively. The linear quantification range of the method was 0.1–20.0 µg/mL in human plasma with linear correlation coefficients greater than 0.999. The intra‐ and inter‐day accuracy for NPD‐103 at 1.0, 5.0 and 10.0 µg/mL levels in human plasma fell into the ranges of 95.29–100.00% and 91.04–94.21%, and the intra‐ and inter‐day precisions were in the ranges of 8.96–11.79% and 7.25–10.63%, respectively. This assay is applied to determination of half‐life of NPD‐103 in human plasma. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

13.
A new sensitive and selective method based on on‐line solid‐phase extraction (SPE) coupled to liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI‐MS/MS) using a triple quadrupole mass spectrometer has been developed for the determination of epichlorohydrin (ECH) in different types of water samples. ECH is not easily determined directly by ESI‐MS as it is not readily ionized, and it has a low molecular mass and high polarity. Thus, prior derivatization of ECH was necessary, employing 3,5‐difluorobenzylamine as a derivatizing agent with Fe(III) as a catalyst. In order to achieve accurate quantification, correcting for matrix effects, losses in the derivatization process and instrumental deviations, isotope labelled ECH (ECH‐d5) was added as an internal standard (IS) to the water samples. The method was validated based on European SANCO guidelines using drinking and other types of treated water spiked at two concentration levels (0.1 and 1.0 µg/L), the lower level having been established as the limit of quantification (LOQ) of the method. Satisfactory accuracy (recoveries between 70 and 103%), precision (RSD <20%) and linearity (from 0.05 to 50 µg/L, r >0.99) were obtained. The limit of detection (LOD) was set up at 0.03 µg/L. The method was applied to different water samples (drinking water and water samples collected from a municipal treatment water plant). In order to enhance confidence, five selected reaction monitoring (SRM) transitions were acquired, thus obtaining a simultaneous reliable quantification and identification of ECH in water, even at sub‐ppb levels. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

14.
《Analytical letters》2012,45(3):555-568
Abstract

A method was developed for determining 9 anabolic steroids (ASs) residues in animal muscle tissues by gas chromatography‐mass spectrometry (GC/MS). After undergoing enzymolysis, being homogenized, and then being picked‐up by ultrasound the sample was extracted with tert‐Butyl methyl ether, cleaned up through solid‐phase extraction (SPE) based on the reverse phase (RP) principle, and after derivatization of the analyst of interest, analyzed by GC/MS under selective ion monitoring (SIM). The limits of the detection (LOD) of the GC/MS method used for testing epitestosterone (ETS), nandrolon (17β‐NT), 17α‐methyl‐testosterone (MTS), testosterone 17‐propionate (PTS), 17β‐estradiol 3‐benzoate (BES), estrone (ESN), 17β‐estradiol (17β‐ES), 17α‐ethynylestradiol (EES), and estriol (EST) in animal muscle ranged from 0.10 to 0.33 µg/kg and the limits of quantification (LOQ) were from 0.24 to 0.82 µg/kg. The experiments using spiked samples, such as pork, beef, chicken, and fish, made it clear that at addition level of 2.0 µg/kg, the average recovery of the ASs ranged from 62.5% to 80.5%, and the coefficient of variation ranged from 12.5% to 26.8%, while at an addition level of 5.0 µg/kg, the average recovery was from 70.8% to 86.4%, and the coefficient of variation was from 8.8% to 18.4%.  相似文献   

15.
Amphiphilic peptide conjugation affords a significant increase in sensitivity with protein quantification by electrospray‐ionization mass spectrometry. This has been demonstrated for human growth hormone (GH) in serum using N‐(3‐iodopropyl)‐N,N,N‐dimethyloctylammonium iodide as derivatizing reagent. The signal enhancement achieved is up to a factor of 5–6 and enables extension of the applicable concentration range down to the very low concentrations (≤ 1.0 µg/L) as encountered with clinical glucose suppression tests for patients with acromegaly. The method has been validated using a set of serum samples spiked with known amounts of recombinant 22 kDa GH in the range of 0.48 to 7.65 µg/L. The coefficient of variation (CV) calculated based on the deviation of results from the expected concentrations was 3.5%. The limit of detection (LoD) was determined as 0.1 µg/L and the limit of quantification (LoQ) as 0.4 µg/L. The potential of the method as a tool in clinical practice has been demonstrated with patient samples of about 1 µg/L. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

16.
In equine sport, theobromine is prohibited with a threshold level of 2 µg mL?1 in urine, hence doping control laboratories have to establish quantitative and qualitative methods for its determination. Two simple liquid chromatography/mass spectrometry (LC/MS) methods for the identification and quantification of theobromine were developed and validated using the same sample preparation procedure but different mass spectrometric systems: ion trap mass spectrometry (ITMS) and time‐of‐flight mass spectrometry (TOFMS). Particle‐free diluted urine samples were directly injected into the LC/MS systems, avoiding the time‐consuming extraction step. 3‐Propylxanthine was used as the internal standard. The tested linear range was 0.75–15 µg mL?1. Matrix effects were evaluated analyzing calibration curves in water and different fortified horse urine samples. A great variation in the signal of theobromine and the internal standard was observed in different matrices. To overcome matrix effects, a standard additions calibration method was applied. The relative standard deviations of intra‐ and inter‐day analysis were lower than 8.6 and 7.2%, respectively, for the LC/ITMS method and lower than 5.7 and 5.8%, respectively, for the LC/TOFMS method. The bias was less than 8.7% for both methods. The methods were applied to two case samples, demonstrating simplicity, accuracy and selectivity. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

17.
A fast and sensitive liquid chromatography/triple quadrupole tandem mass spectrometry (LC/MS/MS) method was developed for the simultaneous determination of morphine, codeine, 6‐acetylmorphine (6‐AM), cocaine and benzoylecgonine (BE) in hair. Pulverized hair samples were extracted with methanol, and a 50 µL supernatant aliquot was injected into the LC/MS/MS system. Chromatography was performed with an XBridge? phenyl column (3.5 µm particle size, 4.6 × 150 mm), and the mobile phase was composed of methanol and 10 mM ammonium acetate adjusted to pH 4.00 with 99% formic acid (95:5, v/v). A separation run with isocratic elution was completed in 10 min at a flow rate of 500 µL/min. Positive electrospray ionization and multiple reaction monitoring (MRM) with one precursor ion/product ion transition were used for the identification of each analyte. Deuterated analogues as internal standards were used for quantification and qualification. Linearity was established in the concentration range of 100–3000 pg/mg. The limits of detection were 10 pg/mg for morphine, codeine and 6‐AM; and 1 pg/mg for cocaine and BE. The precision and accuracy were determined by spiking hair samples at six concentration levels. For all analytes, the relative standard deviations of intra‐ and inter‐day precision were 0.1–6.3% and 1.5–10.6%, respectively. The accuracy ranged from 92.7 to 109.7%. The validated LC/MS/MS method was successfully applied to the analysis of 79 authentic hair samples. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

18.
In this study a method of flow-assisted automated solid-phase microextraction (FA-SPME) was developed for the determination of organic pollutants in aqueous samples. A CTC Combi-PAL autosampler coupled with gas chromatography–mass spectrometry (GC–MS) was used to automate the entire extraction process. In this method, the SPME fibre was exposed to 100 mL of sample in a direct immersion mode for 10 min. After exposure, the fibre was desorbed at the injection port of GC–MS. To demonstrate the applicability of FA-SPME, chloroethers were selected as model compounds. Good linear correlation was found over a concentration range of 0.5–100 µg/L. The detection limits of the method were determined between 0.02 and 0.05 µg/L with the coefficients of determination (R2) from 0.9980 to 0.9996. The relative standard deviations (RSDs) of the FA-SPME for three sequential FA-SPME analyses were determined to be in the range between 1.2% and 6.2% (n = 3). The applicability of the method was assessed by means of recovery studies and satisfactory values for all compounds were obtained. This optimised method was used in the analysis of water and human urine samples to show the matrix effect on FA-SPME. This FA-SPME/GC–MS is substantially faster and suitable for the routine continuous flow-mode environmental monitoring applications.  相似文献   

19.
The use of stable isotope labelled glucose provides insight into glucose metabolism. The 13C‐isotopic enrichment of glucose is usually measured by gas chromatography/mass spectrometry (GC/MS) or gas chromatography/combustion/isotope ratio mass spectrometry (GC/C/IRMS). However, in both techniques the samples must be derivatized prior to analysis, which makes sample preparation more labour‐intensive and increases the uncertainty of the measured isotopic composition. A novel method for the determination of isotopic enrichment of glucose in human plasma using liquid chromatography/isotope ratio mass spectrometry (LC/IRMS) has been developed. Using this technique, for which hardly any sample preparation is needed, we showed that both the enrichment and the concentration could be measured with very high precision using only 20 µL of plasma. In addition, a comparison with GC/MS and GC/IRMS showed that the best performance was achieved with the LC/IRMS method making it the method of choice for the measurement of 13C‐isotopic enrichment in plasma samples. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

20.
This report details a method using liquid chromatography–tandem mass spectrometry (LC‐MS/MS) that allows one to determine the concentration of an atypical anticancer drug, enzalutamide, in rat plasma. Specifically, this method involves the addition of an acetonitrile and bicalutamide (internal standard) solution to plasma samples. Following centrifugation of this mixture, an aliquot of the supernatant was directly injected into the LC‐MS/MS system. Separation was achieved using a column packed with octadecylsilica (5 µm, 2.1 × 50 mm) with 10 mM ammonium acetate in acetonitrile as the mobile phase; detection was accomplished using MS/MS by multiple‐reaction monitoring via an electrospray ionization source. This method demonstrated a linear standard curve (r = 0.997) over a concentration range of 0.001–1 µg/mL, as well as an intra‐ and inter‐assay precision of 2.7 and 5.1%, respectively, and an accuracy range from 100.8 to 105.6%. The lower limit of quantification was 1.0 ng/mL in 50 μL of rat plasma sample. We also demonstrated that this analytical method could be successfully applied to the pharmacokinetic study of enzalutamide in rats. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号