首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Some selected drugs including captopril, fudosteine and racecadotril have been analyzed by infrared (IR) laser desorption/tunable synchrotron vacuum ultraviolet (VUV) photoionization mass spectrometry (PIMS). The molecular ions of captopril and racecadotril are exclusively observed without any fragments at near threshold single-photon ionization (SPI). However, fudosteine easily forms fragments even at a photon energy near the ionization threshold, indicating the instability of its molecular ion. For these drugs, a number of fragments are yielded with the increase of photon energy. The structures of such fragments proposed by IR LD/VUV PIMS are supported by electron ionization time-of-flight mass spectrometry (EI-TOFMS) results. Fragmentation pathways are discussed in detail.  相似文献   

2.
3.
4.
The pyrolysis process of pine wood, a promising biofuel feedstock, has been studied with tunable synchrotron vacuum ultraviolet photoionization mass spectrometry. The mass spectra at different photon energies and temperatures as well as time-dependent profiles of several selected species during pine wood pyrolysis process were measured. Based on the relative contents of three lignin subunits, the data indicate that pine wood is typical of softwood. As pyrolysis temperature increased from 300 to 700 °C, some more details of pyrolysis chemistry were observed, including the decrease of oxygen content in high molecular weight species, the observation of high molecular weight products from cellulose chain and lignin polymer, and potential pyrolysis mechanisms for some key species. The formation of polycyclic aromatic hydrocarbons (PAHs) was also observed, as well as three series of pyrolysis products derived from PAHs with mass difference of 14 amu. The time-dependent profiles show that the earliest products are formed from lignin, followed by hemicellulose products, and then species from cellulose.
Figure
The pyrolysis study of pine wood based on synchrotron vacuum ultraviolet photoionization mass spectrometry.  相似文献   

5.
Atmospheric pressure matrix-assisted laser desorption/ionisation quadrupole ion trap (AP-MALDI/QIT) mass spectrometry has been investigated for the analysis of polyethylene glycol (PEG 1500) and a hyperbranched polymer (polyglycidol) in the presence of alkali-metal salts. Mass spectra of PEG 1500 obtained at atmospheric pressure showed dimetallated matrix/analyte adducts, in addition to the expected alkali-metal/PEG ions, for all matrix/alkali-metal salt combinations. The relative intensities of the desorbed ions were dependent on the matrix, the alkali-metal salt added to aid cationisation and the ion trap interface conditions [capillary temperature, in-source collisionally-induced dissociation (CID)]. These data indicate that the adducts are rapidly stabilised by collisional cooling enabling them to be transferred into the ion trap. Experiments using identical sample preparation conditions were carried out on a vacuum MALDI time-of-flight (ToF) mass spectrometer. In all cases, vacuum MALDI-ToF spectra showed only alkali-metal/PEG ions and no matrix/analyte adducts. The tandem mass spectrometry (MS/MS) capability of the ion trap has been demonstrated for a lithiated polyglycol yielding a rich fragment-ion spectrum. Analysis of the hyperbranched polymer polyglycidol by AP-MALDI/QIT reveals the characteristic ion series for these polymers as also observed under vacuum MALDI-ToF conditions.  相似文献   

6.
The application of synchrotron vacuum ultraviolet (VUV) photoionization combined with molecular-beam mass spectrometry, also called synchrotron VUV photoionization mass spectrometry (SVUV-PIMS), in the research of the thermal decomposition of polypropylene (PP) was studied, and some main pyrolysis products formed at different photon energies have been identified. Using SVUV-PIMS, some isomers can be distinguished, which are much helpful for further understanding of the thermal decomposition of PP.  相似文献   

7.
8.
The thermal decomposition of polymers (poly(vinyl chloride) (PVC) and polystyrene (PS)) has been studied with synchrotron VUV photoionization mass spectrometry at low pressure. Pyrolysis products formed at different temperatures have been identified by the measurement of photoionization mass spectra at different photon energies. The experimental results demonstrate the variation of the pyrolysis product pool of PVC at different temperatures, dividing the thermal decomposition process into two stages: the low‐temperature stage to form HCl and benzene, and the high‐temperature stage to form numerous large aromatic hydrocarbons. For the thermal decomposition of PS, four reaction categories are determined. This work reports a new application of synchrotron VUV photoionization mass spectrometry in the study of the thermal decomposition of polymers, and demonstrates its good performance in product analysis, which is expected to help understand the thermal decomposition mechanism of PVC, PS and other synthesized polymers. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

9.
We have developed an effusive laser photodissociation radical source, aiming for the production of vibrationally relaxed radicals. Employing this radical source, we have measured the vacuum ultraviolet (VUV) photoionization efficiency (PIE) spectrum of the propargyl radical (C(3)H(3)) formed by the 193 nm excimer laser photodissociation of propargyl chloride in the energy range of 8.5-9.9 eV using high-resolution (energy bandwidth = 1 meV) multibunch synchrotron radiation. The VUV-PIE spectrum of C(3)H(3) thus obtained is found to exhibit pronounced autoionization features, which are tentatively assigned as members of two vibrational progressions of C(3)H(3) in excited autoionizing Rydberg states. The ionization energy (IE = 8.674 +/- 0.001 eV) of C(3)H(3) determined by a small steplike feature resolved at the photoionization onset of the VUV-PIE spectrum is in excellent agreement with the IE value reported in a previous pulsed field ionization-photoelectron study. We have also calculated the Franck-Condon factors (FCFs) for the photoionization transitions C(3)H(3) (+)(X;nu(i),i = 1-12)<--C(3)H(3)(X). The comparison between the pattern of FCFs and the autoionization peaks resolved in the VUV-PIE spectrum of C(3)H(3) points to the conclusion that the resonance-enhanced autoionization mechanism is most likely responsible for the observation of pronounced autoionization features. We also present here the VUV-PIE spectra for the mass 39 ions observed in the VUV synchrotron-based photoionization mass spectrometric sampling of several premixed flames. The excellent agreement of the IE value and the pattern of autoionizing features of the VUV-PIE spectra observed in the photodissociation and flames studies has provided an unambiguous identification of the propargyl radical as an important intermediate in the premixed combustion flames. The discrepancy found between the PIE spectra obtained in flames and photodissociation at energies above the IE(C(3)H(3)) suggests that the PIE spectra obtained in flames might have contributions from the photoionization of vibrationally excited C(3)H(3) and/or the dissociative photoionization processes involving larger hydrocarbon species formed in flames.  相似文献   

10.
We analyzed oligonucleotides by nanoparticle-assisted laser desorption/ionization (nano-PALDI) mass spectrometry (MS). To this end, we prepared several kinds of nanoparticles (Cr-, Fe-, Mn-, Co-based) and optimized the nano-PALDI MS method to analyze the oligonucleotides. Iron oxide nanoparticles with diammonium hydrogen citrate were found to serve as an effective ionization-assisting reagent in MS. The mass spectra showed both [M - H](-) and [M + xMe(2+)- H](-) (Me: transition metal) peaks. The number of metal-adducted ion signals depended on the length of the oligonucleotide. This phenomenon was only observed using bivalent metal core nanoparticles, not with any other valency metal core nanoparticles. Our pilot study demonstrated that iron oxide nanoparticles could easily ionize samples such as chemical drugs and peptides as well as oligonucleotides without the aid of an oligonucleotide-specific chemical matrix (e.g., 3-hydroxypicolinic acid) used in conventional MS methods. These results suggested that iron-based nanoparticles may serve as the assisting material of ionization for genes and other biomolecules.  相似文献   

11.
In order to meet the challenges facing modern chemistry, biology, and medicine, methods are required capable of performing rapid and reliable analysis of both individual compounds and complex mixtures at the molecular level. Matrix-assisted laser de-sorption/ionization mass spectrometry meets these requirements; however, some limitations complicate its application for the analysis of small molecules. Recently, small-molecule analysis has greatly progressed owing to development of surface-assisted laser desorption/ionization mass spectrometry involving approaches which combine the unique properties of nanostructured surface chemistry and morphology. This review examines such approaches and their specific application in small-molecule mass analysis.  相似文献   

12.
Authentication of edible oils is a long-term issue in food safety, and becomes particularly important with the emergence and wide spread of gutter oils in recent years. Due to the very high analytical demand and diversity of gutter oils, a high throughput analytical method and a versatile strategy for authentication of mixed edible oils and gutter oils are highly desirable. In this study, an improved matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) method has been developed for direct analysis of edible oils. This method involved on-target sample loading, automatic data acquisition and simple data processing. MALDI-MS spectra with high quality and high reproducibility have been obtained using this method, and a preliminary spectral database of edible oils has been set up. The authenticity of an edible oil sample can be determined by comparing its MALDI-MS spectrum and principal component analysis (PCA) results with those of its labeled oil in the database. This method is simple and the whole process only takes several minutes for analysis of one oil sample. We demonstrated that the method was sensitive to change in oil compositions and can be used for measuring compositions of mixed oils. The capability of the method for determining mislabeling enables it for rapid screening of gutter oils since fraudulent mislabeling is a common feature of gutter oils.  相似文献   

13.
The paper reports the discovery of three new matrices for the matrix-assisted laser desorption of proteins. These new matrices (sinapinic, ferulic and caffeic acids) are cinnamic acid derivatives that have several practical advantages over the nicotinic acid matrices previously used. These materials form much less intense photochemically generated adduct peaks in the protein quasimolecular ion signal and the adduct peaks that are present are easier to resolve. These matrices produce intense protonated-molecule ions from all of the proteins (over 50) so far examined. These new matrices are also very stable in a vacuum, allowing for their convenient use in very high vacuum applications (e.g., Fourier transform ion cyclotron resonance mass spectrometry).  相似文献   

14.
Visible matrix-assisted laser desorption/ionization (VIS-MALDI) was performed using 2-amino-3-nitrophenol as matrix. The matrix is of near-neutral pH, and has an optical absorption band in the near-UV and visible region. A frequency-doubled Nd:YAG laser operated at 532 nm wavelength was used for matrix excitation and comparisons were made with a frequency-tripled Nd:YAG laser (355 nm). Visible and ultraviolet (UV)-MALDI produce similar mass spectra for peptides, polymers, and small proteins with comparable sensitivities. Due to the smaller optical absorption coefficient of the matrix at 532 nm wavelength, the optical penetration depth is larger, and the sample consumption per laser shot in VIS-MALDI is higher than that of UV-MALDI. Nevertheless, VIS-MALDI using 2-amino-3-nitrophenol as matrix may offer a complementary technique to the conventional UV-MALDI method in applications where deeper laser penetration is required.  相似文献   

15.
We demonstrate that the vacuum ultraviolet (VUV) photodissociation dynamics of N(2) and CO(2) can be studied using VUV photoionization with time-sliced velocity-mapped ion imaging (VUV-PI-VMI) detection. The VUV laser light is produced by resonant sum frequency mixing in Kr. N(2) is used to show that when the photon energy of the VUV laser is above the ionization energy of an allowed transition of one of the product atoms it can be detected and characterized as the wavelength is varied. In this case a β parameter = 0.57 for the N((2)D°) was measured after exciting N(2)(o(1)Π(u), v(') = 2, J(') = 2) ← N(2)(X(1)Σ(g) (+), v(") = 0, J(") = 1). Studies with CO(2) show that when there is no allowed transition, an autoionization resonance can be used for the detection of a product atom. In this case it is shown for the first time that the O((1)D) atom is produced with CO((1)Σ(+)) at 92.21 nm. These results indicate that the VUV laser photodissociation combined with the VUV-PI-VMI detection is a viable method for studying the one-photon photodissociation from the ground state of simple molecules in the extreme ultraviolet and VUV spectral regions.  相似文献   

16.
Adams MJ  Kirkbright GF  Taylor RM 《Talanta》1976,23(3):187-192
The construction and operation of a simple, solar-blind photoionization detector which responds to incident radiation between 125 and 140 nm is described. The detector, the response characteristics of which are controlled by the ionization potential of the ethylamine filler gas and the calcium fluoride window employed, is shown to provide for efficient detection of atomic line emission from carbon, oxygen and chlorine in this wavelength region. The spectral sources employed for non-dispersive work with this detector are a microwave-excited argon plasma and a demountable hollow-cathode lamp.  相似文献   

17.
A new method of electrospray-assisted laser desorption/ionization (ELDI) mass spectrometry, which combines laser desorption with post-ionization by electrospray, was applied to rapid analysis of solid materials under ambient conditions. Analytes were desorbed from solid metallic and insulating substrata using a pulsed nitrogen laser. Post-ionization produced high-quality mass spectra characteristic of electrospray, including protein multiple charging. For the first time, mass spectra of intact proteins were obtained using laser desorption without adding a matrix. Bovine cytochrome c and an illicit drug containing methaqualone were chosen in this study to demonstrate the applicability of ELDI to the analysis of proteins and synthetic organic compounds.  相似文献   

18.
Direct matrix-assisted laser desorption/ionization time-of-flight mass spectrometric (MALDI-TOFMS) analysis of solutions of edible fats/oils yielded spectra useful for their rapid differentiation and classification. Results also reflected the individual fatty acid components and their degree of unsaturation. After dissolution in hexane, MALDI-MS analysis revealed spectra showing characteristic triacylglycerols (TAGs), the main fat/oil components, as sodium adduct ions. The Euclidean distances calculated using the mass and intensity values for 20 TAGs were used to evaluate and compare spectra. With cluster analysis, animal fats grouped together differently than vegetable oils and the individual oils grouped together by type. The ion abundances for the individual TAGs and their presumed compositions were used to approximate the overall fatty acid composition of canola, soybean, corn, olive and peanut oil, as well as lard. Using this approach the calculated fatty acid compositions and degree of unsaturation generally fell within about 4% of literature values. When the degree of saturation was compared with values calculated from the package labeling the differences were about 7%.  相似文献   

19.
The development and characterization of a new instrument for solid sampling which couples IR laser desorption followed by UV laser photo-ionization and analysis using an ion trap mass spectrometer has been investigated. For calibration, a new type of solid sample preparation involving activated charcoal as the solid substrate was used. This solid sample provided a steady signal for several thousand laser shots, which allowed optimization of the experimental procedure. It was found that both the IR and UV intensity and the delay between them play an important role in both the magnitude and type of signals observed. A method of gas phase accumulation with multiple laser shots was examined. Finally, this technique was demonstrated to be effective in providing direct qualitative information for N.I.S.T. SRM 1944 river sediment sample with no sample pre-treatment.  相似文献   

20.
A simple and rapid approach to obtaining target plates for the investigation of low-molecularweight compounds by surface-assisted laser desorption/ionization (SALDI) mass spectrometry is proposed. It consists in the vacuum sputtering of a carbon layer with a thickness of about 50 nm onto a metal surface. The resulting coatings are characterized by homogeneity, hydrophobicity, and high mechanical strength, which eliminates a possibility of mass spectrometer contamination. A comparison of the SALDI mass spectra of test compounds recorded using conventional carbon materials and carbon nanocoatings demonstrates advantages of the last named materials, such as high spectral resolution and the absence of spectral interferences at low m/z values.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号